Rohnson Dehumidifier R-9530 Inverter WiFi

Instruction Manual

Introduction

Thank you for selecting a Rohnson dehumidifier. Please read this manual carefully before use and keep it in a safe place for future reference. Ensure the appliance is in good condition after unpacking. Keep packaging materials away from children to prevent suffocation.

1. Before You Begin

Please read the operating instructions carefully before using your dehumidifier for the first time.

Symbols from the Unit and User Manual

? Warning: This unit uses a flammable refrigerant. If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.
? Read the USER MANUAL carefully before operation.
ℹ️ Further information is available in the USER MANUAL, SERVICE MANUAL, and the like.
?‍? Service personnel are required to carefully read the USER MANUAL and SERVICE MANUAL before operation.

2. For Your Safety

Please read the operating instructions carefully before using your dehumidifier for the first time and keep them in a safe place.

  1. Never immerse the appliance in water or other liquids.
  2. Place the unit on a stable flat surface to avoid loud noises and vibrations.
  3. Never operate the appliance if a cable or connector has been damaged, after appliance malfunction or if the appliance was dropped or otherwise damaged.
  4. The appliance may only be repaired by qualified personnel; improper repair work can be a source of considerable danger for the users.
  5. Pull out the power plug before transporting it and/or before cleaning.
  6. Operate the appliance only at the voltage specified on the rating label.
  7. The device may not be connected to a power strip with other household appliances.
  8. Use the appliance only in the household and only for the purpose it was developed for.
  9. Do not operate this unit near heating appliances and flammable or dangerous objects.
  10. If the dehumidifier is operated in a room with gas driven devices, the room must be aired regularly and often.
  11. Please use the function of the internal drying if the device is not used for a long time. This will prevent formation of mildew and unpleasant smell inside the unit.
  12. Do not place heavy objects on the appliance.
  13. Do not hang curtains or wet clothes in front of the air outlet, this will overload the device.
  14. The drainage hose may not be installed outdoors at low temperatures.
  15. To prevent spillage, empty the water tank before relocating the appliance.
  16. Do not tip the appliance to any side as escaping water could damage the appliance.
  17. If the supply cord is damaged, it must be replaced by a qualified person to avoid a hazard.
  18. If you smell smoke during start-up or can see smoke, immediately disconnect the power plug and contact your dealer.
  19. The unit should be installed with a minimum distance of 50 cm from the wall or other obstacles.

WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (e.g., open flames, operating gas or electric heaters). Do not pierce or burn. Be aware that refrigerants may not contain an odor. The maximum refrigerant charge amount is 10 g. When the machine malfunctions, do not repair it yourself. Please contact a professional organization or a professional trained maintenance personnel or a service organization recommended by the supplier for repair!

This appliance can be used by children aged 8 years and above and people with reduced physical, sensory, and mental capabilities or lack of experience and knowledge if they have been given supervision instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and maintenance shall not be made by children without supervision.

Service & Repair

  1. For service or repair under warranty, please contact the authorized service company mentioned on the guaranteed card.
  2. Do not operate any product with a damaged cord or plug. Do not attempt to dismantle any part of the appliance. This should only be done at an authorized service center.
  3. Partial or total non-respect of the safety instructions in this manual will automatically release the company of any responsibility in case of malfunction or injuries to persons or animals.
  4. In case of manipulation, repairing, or any modification of the machine made by unqualified persons or in case of improper use, the guarantee will be automatically cancelled.

3. Product Overview

Front & Panel View

Exterior: The dehumidifier is a cylindrical unit featuring an air outlet grille at the top, an air inlet grille on the side, a rotatable water tank handle, a baffle board, a water tank, and wheels at the base.

Control Panel: The control panel includes indicators for Water Full, Child Lock, Timer, and Wi-Fi. It also features mode indicators for Smart Mode, Sleep Mode, and Clothes Drying Mode, along with Anion Indicator, Humidity/Turn-off Time display, and Humidity Status Indicator. Control buttons include On/Off, Timer, Mode, and Humidity Setting.

Drainage Hose: A drainage hose is included for continuous water removal.

4. Installation

Location

  1. Place the unit on a firm, level surface in an area with at least 30cm of free space around it to allow for proper air circulation.
  2. Never install the unit where it could be subject to:
    • Heat sources such as radiators, heat registers, stoves, or other products that produce heat.
    • Areas where oil or water may be splashed.
    • Direct sunlight.
    • Mechanical vibration or shock.
    • Excessive dust.
    • Lack of ventilation, such as inside a cabinet or bookcase.

WARNING: Install the unit in rooms which exceed 4 m². Do not install the unit in a place where inflammable gas may leak.

NOTE: The manufacturer may provide other suitable examples or additional information about the refrigerant odor.

5. Operation

Control Panel

Drainage

There are two ways to remove collected water:

Continuous Water Drainage

6. Maintenance

Maintenance Precautions

Cleaning the Dehumidifier

Soak a cloth in water below 45°C, wring it out, and use it to gently wipe over dirty areas.

Cleaning the Filter

  1. Pull the water tank out horizontally from the opening at the top of the water tank.
  2. Remove the air inlet grille, and then remove the inner air filter.
  3. Rinse the filter and the air inlet grille with water or use a vacuum cleaner. If the filter is particularly dirty (e.g., oil stains), use warm water (below 45°C) with neutral detergent and then dry it in a cool place.
  4. Reinstall the fully dried filter, the air inlet grille, and the water tank.

Cleaning the Water Tank

  1. Pull the water tank out horizontally from the opening at the top of the water tank.
  2. Lift the handle of the water tank and rotate it about 60° until the indicator line on the handle is horizontal. Apply slight force on the handle in the direction shown by the arrows. Take the left and right shafts of the handle out one at a time to remove the handle.
  3. Remove the cover of the water tank from the spout on the top right corner of the water tank.
  4. Clean the water tank and fully dry it. Then attach the cover and the handle to the water tank and reinstall the water tank.

When Not Use for a Long Time

Let the dehumidifier sit for two days after entering standby mode and unplugging it. Clean the dehumidifier, water tank, and filter. Coil up the power cord and secure it with a cable tie. Store the dehumidifier in its packaging, upright, in a dry and well-ventilated place.

7. Troubleshooting

Before Calling for Service

Before contacting professional service, please review the troubleshooting list for common occurrences that are not the result of a defect.

ISSUE CAUSE & SOLUTION
The dehumidifier suddenly shakes when it turns on, enters standby mode, or operates. This is caused by the start or stop of the compressor, which is normal.
The dehumidifier does not work well. It is recommended to use the dehumidifier indoors at a temperature from 5°C to 35°C. Check whether the humidity is set appropriately. Check whether the air inlet or air outlet is dirty or blocked and clean them. Check if doors and windows are open; it is recommended to close them and turn off other ventilation equipment when the dehumidifier is operating.
The dehumidifier cannot work. Check for a power failure. Check if the power plug has become loose. Check if the water tank is full or has been installed incorrectly. Check if the timer function is being used.
The dehumidifier leaks water. Check whether the drainage hose has become loose. Check whether the drainage system is blocked.
The dehumidifier makes unusual sounds when running. Check whether the dehumidifier is on a flat surface. Check whether the filter is blocked. Check whether the refrigerant makes sound when the compressor is turned on.
Black stains appear in the water tank. The black stains are caused by air dust and materials attached to the evaporator and condenser surfaces, flowing into the water tank with condensate. This is normal. Directly wipe them with a paper towel; the black stains will decrease with continued use.

Common Error Codes

CODE DESCRIPTION SOLUTION
C2 Fan error Turn the dehumidifier off for 5 minutes and then turn it on again. If the error code appears multiple times, please contact the after-sales service team.
C3 Communication error between display and motherboard Disconnect the dehumidifier from the electrical outlet, then reconnect it. If the issue persists, please contact the after-sales service team.
E1/E3/E4 Pipe temperature sensor error Turn the dehumidifier off for 5 minutes and then turn it on again. If the error code appears multiple times, please contact the after-sales service team.
E9 Humidity sensor error Turn the dehumidifier off for 5 minutes and then turn it on again. If the error code appears multiple times, please contact the after-sales service team.
H0 Over-exhaust protection Turn the dehumidifier off for 5 minutes and then turn it on again. If the error code appears multiple times, please contact the after-sales service team.
H1 Overload protection Check whether the dehumidifier's air inlet or air outlet is blocked. Turn the dehumidifier on again. If the error code appears multiple times, please contact the after-sales service team.
H6 Fluoride deficiency protection Turn the dehumidifier off for 5 minutes and then turn it on again. If the error code appears multiple times, please contact the after-sales service team.
H8 Overheating protection Make sure the dehumidifier is working between 5°C and 40°C. If the error code still appears, please contact the after-sales service team.
H9 Dumping protection If the machine is in a tipping state, please turn off the power, upright the machine, stand it upright for 12 hours, and then power on again.
L4/L5 Compressor module protection Turn the dehumidifier off for 5 minutes and then turn it on again. If the error code appears multiple times, please contact the after-sales service team.

Specifications

The high-temp dehumidification capacity is measured at a room temperature of 30°C with 80% RH. The results may vary due to actual operating conditions.

The dehumidifier's operating temperature range is from 5°C to 40°C. If the indoor temperature is out of this range, the dehumidifier may not be able to work.

If specifications change, the details on the dehumidifier's nameplate shall prevail without notice.

8. Decommissioning

Storage

For long-term storage (more than a few weeks), it is best to clean the unit and dry it out completely. Store the unit per the following steps:

  1. Press the power button to switch off and unplug the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let it dry completely in a shaded area.
  4. Collect the power cord at the water tank.
  5. Re-install the filter at its position.
  6. The unit must be kept in an upright position when in storage.
  7. Preserve the machine in a ventilating, dry, non-corrosive gas, and safe indoor place.

9. Disposal

Important Information for Correct Disposal of the Product in Accordance with EC Directive 2002/96/EC

At the end of its working life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service. Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving from inappropriate disposal and enables the constituent materials to be recovered, obtaining significant savings in energy and resources. As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed-out wheeled dustbin ?️.

EU Declaration of Conformity

Manufacturer: Zhuhai Samyou Environmental Technology Co., Ltd

Address: Unit 3-B-2, Building 4, Zhongdian high tech industrial park, 7th technology road, Tangjiawan town, Xiangzhou, Zhuhai, Guangdong, China

Model No.: R-9530 (VD30A-VA5A)

Description: Dehumidifier

Radio-related Software Version: Wi-Fi modular: WBR-1

Zhuhai Samyou Environmental Technology Co., Ltd declares under its sole responsibility that the product described above is in conformity with the relevant Union Harmonization Legislations:

The following harmonized standards and/or other relevant standards have been applied:

  1. Health and Safety (Article 3.1(a) of the RE Directive)
    EN62311:2020, EN 61000-3-3:2013+A2:2021, EN IEC 55014-1:2021, EN IEC 55014-2:2021, EN IEC61000-3-2:2019 +A1:2021
  2. Electromagnetic compatibility (Article 3.1(b) of the RE Directive 2014/30EU (EMCD))
    EN301 489-1 V2.2.3, EN 301489-17 V3.2.4, EN301 489-17 V3.1.1(2017)
  3. Radio frequency spectrum usage (Article 3.2 of the RE Directive)
    EN300 328V2.2.2(2016)
  4. RoHS Directive 2011/65/EU
    IEC62321-3-1:2013, IEC62321-4:2013 + AMD1:2017, IEC62321-5:2013, IEC62321-6:2015, IEC62321-7-1:2015, IEC62321-7-2:2017, IEC62321-8:2017

The object of the declaration described above is in conformity with the following relevant Union harmonization legislation(s):

Radio Equipment Directive (RED) 2014/53/EU
Low Voltage Directive (LVD) 2014/35/EU
Electromagnetic Compatibility (EMC) 2014/30/EU
Restriction of the use of certain hazardous substances (Rohs) 2011/65/EU

The recognized third-party organization (Name: SGS-CSTC Standards Technical Services Co., Ltd) performed the conformity assessment according to Annex II of the RE Directive and issued the EU-type examination certificate (Ref. No.: GZES240100116901).

Signed for and on behalf of Zhuhai Samyou Environmental Technology Co.,Ltd.

Signature: [Signature Placeholder]

Name: 杨博

Position: Compliance Engineer

Date: 2024-02-28

Place: Zhuhai

Radio Equipment Specifications

The frequency bands on which the radio is operating are 2.4 GHz and the maximum radio output power is 17dBm.

Wi-Fi Specification

Models: R-9530 Inverter WiFi, R-9530, Inverter WiFi, WiFi

File Info : application/pdf, 19 Pages, 796.56KB

PDF preview unavailable. Download the PDF instead.

IM-R-9530-Inverter-WiFi-ΕΝ-with-EU-declaration

References

iLovePDF

Related Documents

Preview Rohnson Dehumidifier R-9350 / R-9370 User Manual and Safety Guide
Comprehensive user manual for Rohnson dehumidifiers R-9350 and R-9370, covering operation, safety precautions, maintenance, troubleshooting, and specifications. Learn how to use your Rohnson dehumidifier safely and effectively.
Preview Rohnson R-91810/R-91812 Dehumidifier User Manual
Comprehensive user manual for the Rohnson R-91810 and R-91812 dehumidifiers, covering safety instructions, operation, installation, maintenance, and troubleshooting.
Preview Rohnson R-9820 Genius Wi-Fi Dehumidifier: Instruction Manual
Comprehensive instruction manual for the Rohnson R-9820 Genius Wi-Fi Dehumidifier (Model TYWE1S). Learn about safe operation, parts identification, usage modes, maintenance, troubleshooting, and disposal.
Preview Rohnson R-9920 Genius Wi-Fi Health & Clean Dehumidifier User Manual
Comprehensive user manual for the Rohnson R-9920 Genius Wi-Fi Health & Clean dehumidifier, covering safety instructions, device operation, features, maintenance, troubleshooting, and technical specifications.
Preview Rohnson R-91220 Dehumidifier: Instruction Manual & Specifications
Comprehensive instruction manual for the Rohnson R-91220 Dehumidifier, covering operation, safety precautions, maintenance, troubleshooting, and technical specifications. Learn how to use and care for your Rohnson dehumidifier.
Preview Rohnson R-9920 Genius 20 Wi-Fi ION & UV-C Dehumidifier User Manual
This user manual provides comprehensive instructions for operating and maintaining the Rohnson R-9920 Genius 20 Wi-Fi ION & UV-C dehumidifier. It covers safety precautions, appliance description, control panel functions, operation modes, cleaning, troubleshooting, and technical specifications.
Preview Rohnson R-9420r Genius Wi-Fi Dehumidifier Instruction Manual
User guide for the Rohnson R-9420r Genius Wi-Fi Dehumidifier, detailing operation, safety, maintenance, and troubleshooting steps for optimal home use.
Preview Rohnson R-9920 Genius Wi-Fi Health & Clean Dehumidifier Instruction Manual
This instruction manual provides detailed information on operating, maintaining, and troubleshooting the Rohnson R-9920 Genius Wi-Fi Health & Clean dehumidifier. It covers safety precautions, parts identification, operational methods, drainage options, cleaning, and technical specifications.