Rohnson R-91220 Dehumidifier
Instruction Manual
Thank you for choosing our product. For proper operation, please read and keep this manual carefully.
Operation Area
- This dehumidifier is intended for indoor residential applications only. It should not be used for commercial or industrial applications.
- Place the dehumidifier on a smooth and level floor.
- A dehumidifier operating indoors will have no effect in drying an adjacent enclosed area, such as a closet.
- Place the dehumidifier in an area where the temperature will not be below 5°C or above 32°C.
- Allow at least 20-30 cm of air space on all sides of the unit.
- Close all doors, windows and other outside openings of the room to improve the working effect.
- Please keep the air inlet/outlet clean and not blocked.
- Do not use a dehumidifier in a bathroom.
- Avoid direct sunlight.
Diagram showing recommended clearance: 30 cm above, 20 cm to the left, 20 cm to the right.
Notes: The dehumidifier has rollers to aid placement. Do not attempt to roll the dehumidifier on carpet or over objects. Otherwise, water may spill out from the bucket or the dehumidifier may get stuck by the objects.
Safety Precautions
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Before operation, please check the power cord if it complies with the requirement indicated on the nameplate.
- Before cleaning, please turn it off and unplug the dehumidifier.
- Make sure the power cord is not pressed by any hard object.
- Do not remove the power plug or move unit by pulling the power cord.
- Do not use any heating application near the dehumidifier.
- Do not remove the power plug in wet hands.
- Please use a grounded power cord and make sure it's well connected and not damaged.
- Children and disabled people are not allowed to use the dehumidifier without supervision.
Radio equipment: The frequency bands on which the radio is operating are 2.4 GHz and the maximum radiotelephone power is 20 dBm Max.
- Children shall not play with the appliance. Keep children from playing or climbing on the dehumidifier.
- Do not place the dehumidifier under dripping objects.
- Memory function is included in this dehumidifier. When nobody is taking care of the unit, please turn it off and remove the power plug or disconnect power.
- Do not repair or disassemble the unit by yourself.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Cleaning and user maintenance shall not be made by children without supervision.
- If abnormal condition occurs (e.g. burned smell), please disconnect power at once and then contact local dealer.
- Dehumidifier cannot be disposed of everywhere. If you want to get rid of this dehumidifier, please check with local handling disposal or information center about what to do.
WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater. Do not pierce or burn. Be aware that refrigerants may not contain an odour. The maximum refrigerant charge amount: 60 g. When the machine malfunctions, do not repair it yourself. Please contact a professional organization or a service provider.
Parts Name
Front Side
Illustration of the front of the dehumidifier showing: HUMIDITY INDICATOR LIGHT, CONTROL PANEL, HANDLE, ROLLERS.
Back Side
Illustration of the back of the dehumidifier showing: CONTINUOUS DRAIN, WATER TANK.
Check Before Operation
Before operation, please first check whether the float is properly placed.
Checking Steps:
1. Water Bucket Removal:
Hold the handles on both sides of the water bucket and pull it out following the arrow direction.
Diagram illustrating the removal of the water bucket.
2. Float Check:
Check whether the float in the water bucket is properly placed. It might have been moved a little after long-time transportation. If it's not placed properly, move it to the correct position by hand. Please remove the handle and check it.
Operation Method
Indicator Lights
Diagram of the control panel with various indicator lights. The indicators include: Full of water, TIMER, Sleep, Dry clothes, Air clean, swinging, Child lock, Defrost, Normal dehumidifying, Continuous dehumidifying, strong dehumidifying, Low wind, High wind.
Notes:
- Water bucket must be correctly installed for the dehumidifier to operate.
- Do not remove the bucket while the unit is in operation.
- If you want to use a drain hose to drain water away, please install the hose according to the section "Drainage method".
- Each time pressing an effective button on the control panel will give out a "beep" sound.
Basic Functions of the Buttons
Power Button or Stand by [⚡]
Press this button to turn the dehumidifier on/off.
Humidity Settings [?%]
Set humidity, the range is 30%-80%. In normal mode, press left or right arrows to set humidity level.
Sleep Mode [?]
Press the Sleep button to turn on the sleep function. While the machine is still working in any mode, all lights are off except sleep light, water full light, and child lock light. Press any key in sleep mode to perform functions and wake up.
Air Cleaner [?️]
Option to stop the compressor and use the unit as an air purifier only.
Auto Swing button [?]
Press Auto Swing button and the corresponding indicator will light up. The louver will start to swing automatically.
Child Lock [?]
Long press Auto Swing button and Air clean button. Again long press for 5 seconds to unlock.
Fan Speed Button [?]
Pressing this button can set fan speed circularly: High, Low. Corresponding indicator will be on for each fan speed.
Timer Button [⏱️]
Press this button to set Timer On or Timer Off (Timing range 01~24h).
- Set Timer Off: When unit is on, press this button and the Timer Indicator will blink. Timer will increase each time you press the button by 01 to 24 h. When time is set, wait for 5s or press this button to turn this function on.
- Cancel Timer Off: Under the condition that this function is turned on, press the TIMER button until the timer screen shows 00 h.
- Set Timer On: When unit is off, press this button and the Timer Indicator will blink. Timer will increase each time you press the button by 01 to 24 h. When time is set, wait for 5s or press this button to turn this function on.
- Cancel Timer On: Under the condition that this function is turned on, press the TIMER button until the timer screen shows 00 h.
- Timing range: 01~24 hours.
Dehumidify Mode Button [⚙️]
Press this button to select different kinds of working mode. After each pressing of this button, mode will switch among the below options:
- Normal: You can set the target humidity 30% - 80% and the fan speed as you wish.
- Automatic: In this option, the unit works without any set humidity but the fan speed is set to LOW automatically. In this option, you cannot set the humidity; the unit works continuously.
- Strong: The default target humidity level is 30%. The appliance constantly works with the dehumidifying function until ambient humidity reaches 30%. The fan will operate at high speed and cannot be adjusted.
Dry Cloths button [?]
In this option, the unit works appropriately to dry your clothes with the fan speed set to HIGH automatically. In this option, you cannot set the humidity; the unit works continuously.
Other Instructions
1. Alarm Warning
If the bucket is full or not locked into place, a buzzer will go off for 20s to remind you to empty the bucket or put it back into the correct place.
2. Auto Stop
When the bucket is full, removed, or not placed correctly, or if the humidity is 5% lower than the set humidity, the unit will automatically stop.
3. Memory Function
If power is lost, all control settings are remembered. When power is restored, the unit will start back up in the settings it was in when power was lost.
4. Full of Water light [?]
This indicates that the bucket is full or removed or not placed correctly.
IONIC+UV-C Function [✨]
- Connect the appliance to the electric network. The appliance is in standby mode.
- Press the ON / OFF button to switch the appliance on / off.
- When the appliance is switched on, the IONIC function and the UV C lamp start automatically.
- The IONIC function enriches the air with beneficial negative ions, removes dust, and cleans the air in the room. It is suitable for allergy sufferers.
- UV-C lamp helps eliminate unwanted odors and harmful microorganisms.
Drainage Option
Option 1: Emptying Manually
Notes:
- Do not remove the bucket when the unit is in operation or has just stopped. Otherwise, it may cause some water to drip on the floor.
- Do not use the hose if using the water bucket to collect water. When the hose is connected, water will be drained out through it instead of into the bucket.
Steps:
1. Remove Bucket:
Hold the handles on both sides of the water bucket and pull it out following the arrow direction. (Attention: Pull out the bucket carefully in case the water may spill out from the bucket and onto the floor.)
Diagram showing how to pull out the water bucket.
2. Empty Bucket:
Empty the bucket by grasping the handle on the top of the bucket with one hand and grasping the bottom of the bucket with the other hand.
Diagram illustrating emptying the bucket, showing handle and bucket.
3. Replace Bucket:
Replace the bucket in the dehumidifier according to the arrow direction.
Diagram showing how to replace the water bucket.
Option 2: Gravity Drain Hose
A hose is provided, so the user shall prepare it in advance. [Size: The hose thread should have an outer diameter of 10 mm and length 1 meter.]
Steps:
1. Prepare Hose:
Hose is provided; user shall prepare it.
2. Remove Bucket:
Remove bucket from the unit as instructed.
3. Attach Hose:
Thread the drain hose onto the nozzle and make sure it's securely locked.
4. Route Hose:
Replace the bucket. Make sure the drain hose goes through the bucket's drain hole and is placed downward. Lead the hose to the floor drain and then cover the hole with a lid. Note that the drain hose should not be pressed, otherwise water cannot be drained out.
Note: When you want to take off the drain hose, prepare a receptacle to collect water from the nozzle.
Set an Air Clean Filter
Notes:
The time life of the ionic and carbon filter is based on the environmental air, normally it replaces after 1 year. If it is dirty, clean up dust or debris with a brush and dry it in the sunshine.
Clean and Maintenance
Warning:
- Before cleaning, turn off the dehumidifier and disconnect power. Otherwise, it may lead to electric shock.
- Do not wash the dehumidifier with water, or it may lead to electric shock.
- Do not use volatile liquids (such as thinner or gasoline) to clean the dehumidifier. Otherwise, it will damage the unit's appearance.
1. Grille and Case
To clean the case:
When there is dust on the case, use a soft towel to dust it off. When the case is very dirty (greasy), use mild detergent to clean it. To clean the grille: Use a dust catcher or brush.
2. Water Bucket
Every few weeks, clean the bucket to prevent growth of mold, mildew, and bacteria. Use a soft brush to clean the bucket and then rinse it.
Warning:
- Do not operate the dehumidifier without a filter. Otherwise, the evaporator will catch dust and affect the unit's performance.
- Do not dry the air filter with fire or an electric hair dryer. Otherwise, the air filter may be unshaped or caught on fire.
- Don't use a dust catcher or brush to clean the air filter. Otherwise, the air filter may be destroyed.
Check Before Use-season
- Check whether the air outlet is blocked.
- Check whether the power plug and power socket are in good condition.
- Check whether the air filter is clean.
- Check whether the drain hose is damaged.
Long-time Storage
If you won't use the dehumidifier for a long time, we suggest that you follow the steps below in order to maintain the unit in good condition:
- Make sure the bucket is clear of water and the drain hose is removed.
- Unplug the dehumidifier and pack the power cord.
- Clean the unit and wrap it well to prevent the gathering of dust.
Troubleshooting
Note: Not all the following problems are malfunctions.
Problem: Dehumidifier is not operating. Controls can not be set.
Possible Causes:
- Unit is operating in an area where temperature is higher than 32°C or lower than 5°C.
- Bucket is full.
Problem: Noise suddenly rises during operation.
Possible Causes:
- Power noise will supply rise problem if the compressor has just started.
- Unit is placed on an uneven floor.
Problem: Humidity does not drop. / Little or no effect in dehumidifying.
Possible Causes:
- Area to be dehumidified is too large. The capacity of your dehumidifier may not be adequate.
- Doors are open.
- There might be some device producing vapor in the room.
- Room temperature is too low.
- Humidity level may be improperly set.
- If the unit is operating in a room where the temperature is from 5 to 15°C, it will start to defrost automatically. The compressor will stop for a brief period of time (fan will operate in high fan speed). When the unit finishes defrosting, it will be back to normal operation.
Problem: When first operated, the air emitted has musty-odor.
Possible Causes:
- Due to temperature rising of the heat exchanger, the air may have some strange smell at the beginning.
Problem: Unit has noises.
Possible Causes:
- There might be some noise if the unit is operating on a wooden floor.
Problem: Swooshing sound is heard.
Possible Causes:
- Normal. This is the sound of the flow of refrigerant.
Problem: When using drain hose, there is water in the bucket.
Possible Causes:
- Examine the drainage joint.
- Drain hose is not correctly installed.
- Drain hose is not correctly installed.
Solution:
- Connect the drainage joint well.
- Clear the obstacle from the drain hose.
- Remove the drain hose and replace it. Be sure that the hose is correctly installed.
Problem: Dehumidifier does not start.
Possible Causes:
- Bucket full indicator is lit up: Bucket is not properly placed. / Water is full in the bucket. / Bucket has been removed.
- Unit can function normally but cannot start up: Humidity is set too high.
Solution:
- Empty the bucket and replace it.
- If you want the air drier, press the '-' button to lower the setting for the unit to dehumidify continuously.
Unit's Malfunction Codes
Display Code "E2"
Units Condition: Temperature and Humidity Sensor is damaged.
Defrost Procedure
Please note if the ROOM temperature is less than 24°C, the unit will start defrost function!
- ≥24°C: no defrost
- 18-23°C: 2 hours dehumidify then 5 minutes defrost, cycle.
- 12-18°C: 25 minutes dehumidify then 5 minutes defrost, cycle.
- 5-12°C: 8 minutes dehumidify then 3 minutes defrost, cycle.
- ≤5°C: unit protection, compressor off, fan off. All operation mode cannot be activated except air circulation mode.
Problem: Dehumidifier does not dry air as intended. / Bad dehumidifying performance.
Possible Causes:
- Check whether there is any obstacle around the unit.
- Air filter is dusty and blocked.
- Doors and windows are left open.
- Room temperature is too low.
Solution:
- Make sure there is no curtain, shutter or furniture that blocks the dehumidifier.
- Clean the filter.
- Make sure all doors and windows and other openings to the outside have been closed.
- Warm temperature is good for dehumidification. Low temperature will reduce unit's working effect. This unit should be working in a place where temperature is above 5°C.
WIFI Specification
- Model: TYWE1S
- Standard: IEEE 802.11 b/g/n
- Antenna Type: PCB antenna
- Frequency WIFI: 2.4G
- Maximum Transmitted Power: 20 dBm Max
- Dimension: 18x23.5x3.1 mm
- Operation Temperature: -20°C to 85°C
- Operation Humidity: 10% to 85%
- Power input: DC 3V-3.6V
Declarations of Conformity
The R-91220 Genius 2 radio equipment complies with Directive 2014/53/EU. Full texts of declarations are available at the following internet addresses:
- EN: www.vassilias.gr
- GR: www.vassilias.gr
- BG: www.vassilias.bg
- RO: http://vassilias.ro
- CZ: www.rohnson.cz
- SK: www.rohnson.cz
Disposal Information
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC.
At the end of its working life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service.
Disposing of a household appliance separately avoids possible negative consequences for the environment and health, deriving from inappropriate disposal and enables the constituent materials to be recovered to obtain significant savings in energy and resources. As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed-out wheeled dustbin [?️].