Ecler

IC6CLASS-TR CEILING LOUDSPEAKERS

In-ceiling / In-wall High-end Loudspeaker

USER MANUAL

v.20220321

Introduction & Overview

Thank you for choosing the Ecler In-ceiling / In-wall High-end Loudspeaker IC6CLASS-TR. This manual provides essential information for maximizing your use and achieving the best performance from this equipment. For optimal operation and maintenance, it is strongly recommended to use authorized Ecler Technical Services. The Ecler IC6CLASS-TR comes with a 3-year warranty.

The ECLER IC6CLASS-TR is a 2-way loudspeaker designed for high and low impedance applications. It features a careful selection of components, including a 6" woofer and a 1" tweeter, combined with a mechanical design that delivers high-quality audio with a "Hi-Fidelity" profile sound. Its installation process is fast and requires only a basic set of tools.

Main Characteristics:

Important Safety Information

Important Remark:

⚠️ The lightning flash with an arrowhead symbol, within an equilateral triangle, alerts the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

The exclamation point within an equilateral triangle alerts the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

WARNING (If applicable): Terminals marked with a symbol may carry sufficient voltage to constitute a risk of electric shock. External wiring connected to these terminals requires installation by an instructed person or the use of ready-made leads or cords.

WARNING: To prevent fire or shock hazard, do not expose this equipment to rain or moisture.

WARNING: Apparatus with Class I construction must be connected to a mains socket-outlet with a protective earthing connection.

Important Safety Instructions:

  1. Read these instructions carefully.
  2. Keep these instructions for future reference.
  3. Heed all warnings provided.
  4. Follow all instructions given.
  5. Do not use this apparatus near water.
  6. Clean only with a dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
  8. Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades, one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched, particularly at the plugs, convenience receptacles, and where they exit the apparatus.
  11. Only use attachments/accessories specified by the manufacturer.
  12. Unplug the apparatus during lightning storms or when unused for long periods of time.
  13. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as a damaged power supply cord or plug, spilled liquid, objects fallen into the apparatus, exposure to rain or moisture, abnormal operation, or if the apparatus has been dropped.
  14. Disconnecting from mains: When switching off the POWER switch, all functions and light indicators stop. However, fully disconnecting the device from mains is achieved by unplugging the power cable from the mains input socket. This socket must always remain easily accessible.
  15. Equipment is connected to a socket-outlet with an earthing connection by means of a power cord.
  16. The marking information is located at the bottom of the unit.
  17. The apparatus shall not be exposed to dripping or splashing, and no objects filled with liquids, such as vases, shall be placed on the apparatus.

NOTE: FCC Compliance

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

WARNING: Product Disposal

This product must not be discarded, under any circumstance, as unsorted urban waste. Take it to the nearest electrical and electronic waste treatment centre.

NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be caused to people, animals, or objects due to failure to comply with the warnings above.

Location, Assembly, and Connections

For proper product installation, circular holes must be made in selected places, and the appropriate wiring must be prepared for each unit.

Installation Steps:

  1. Make the mounting hole in the drop ceiling, after marking its outline with the supplied cutting template.
  2. Strip and connect the two wires of the speaker cable end to the supplied loose Euroblock terminal, respecting the polarity between the speaker (IN + and -), the other speakers of the system, and the amplifier feeding them. Insert the loose Euroblock connector of the cable into the IN Euroblock terminal of the speaker.
  3. Insert the speaker's frame into the hole, taking care that the 3 revolving fasteners remain in the retracted position.
  4. Tighten each of the 3 screws accessible from the front of the unit. The revolving fasteners rotate, and at the end of the tightening, the frame is fixed in its final position.

NOTE: In most cases, the electro-acoustical response of a ceiling/wall speaker like the IC6CLASS-TR will be better if it is installed in a ceiling or on a wall made of low-porosity materials and without the rear cover. The response in the low frequency range will be especially affected, since these types of ceilings act as "baffles" or mechanical loudspeaker enclosures.

Power Tap Selection:

Using a flat screwdriver, set one of the following taps with the power selector on the front of the speaker:

Power Tap Settings
Tap # Connection to a 70V line Connection to a 100V line
Tap #1 16 Ω - 75 W 16 Ω - 75W
Tap #2 1.5 W 3 W
Tap #3 3.7 W 7.5 W
Tap #4 7.5 W 15 W
Tap #5 10 W 20 W
Tap #6 15 W 30 W
  1. Test the operation by powering up the sound system.
  2. Finally, install the grill on the speaker frame and turn it slightly so that the revolving fasteners of the frame and the grille are fitted together. During assembly, hold the grille by the edges (not the perforated, centre part) to avoid damaging it.

Painting

The IC6CLASS-TR is ready to be painted, allowing it to match any cosmetic criteria of the environment in which it is installed. Once the installation is complete, the front grille is the only visible part of the unit. Paint it carefully to achieve the desired result, avoiding excess paint from clogging the small holes in its central area.

Technical Characteristics

IC6CLASS-TR

System Specifications
Effective frequency range1 61 Hz-20 kHz
Coverage angle2 151°x151° (HxV)
Power handling 75 W RMS / 300 W Peak
Sensitivity3 89 dB (1W/1m)
Maximum SLP 108 dB continuous / 114 dB peak
Power options 100V: 30W / 20W / 15W / 7,5W / 3W / 16Ω
70V: 30W / 20W / 15W / 7,5W / 3,7W / 1,5W / 16Ω
Recommended amplifier power 150 W RMS
Transducers
Ways 2
Low frequency driver 6.5" woofer
High frequency driver 1" silk dome (ACCW) tweeter
Nominal impedance 16Ω
Physical Characteristics
Power type selector Front tap selector
Installation options Ceiling, wall
Grille material Aluminium
External diameter 270 mm / 10.63"
Internal diameter 224 mm / 8.82"
Recommended cut out diameter 227 mm / 8.94"
Required depth 95 mm / 3.74"
Finished color White (RAL 9003)
Ceiling thickness No limit min / 40mm / 1.57" max
Weight 2.5 kg / 5.51 lb

110dB below the sound pressure level at specified sensitivity.
26dB below the sound pressure level than that at the direction of maximum level, Average from 1 kHz to 4 kHz.
3Measured on-axis, far field and referenced to 1 meter by inverse square law. Average from 100 Hz to 10 kHz.
4Calculated from sensitivity and power handling specifications, exclusive of power compression.

Diagrams

Mechanical Diagram

This diagram shows the front view of the IC6CLASS-TR speaker. It displays the Ecler logo, "IC6 CLASS" text, and a circular selector dial. The dial indicates various power tap settings for both 100V and 70V line connections, including options like 30W, 15W, 7.5W, 3W, 1.5W, 50W, and 16Ω.

Mounting Diagram

This diagram illustrates the installation process in four steps:
  1. STEP 1: Shows a circular hole being cut in a ceiling panel.
  2. STEP 2: Depicts stripping speaker wires and connecting them to a loose Euroblock terminal.
  3. STEP 3: Illustrates inserting the speaker frame into the prepared ceiling hole, with three revolving fasteners retracted.
  4. STEP 4: Shows tightening three screws accessible from the front, which causes the revolving fasteners to secure the frame in place. An indication of "x 3" suggests three such fasteners/screws.

Product Information and Disclaimers

All product characteristics are subject to variation due to production tolerances.

NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications.

Contact Information

For technical queries, contact your supplier, distributor, or complete the contact form on the Ecler website under Support / Technical requests.

NEEC AUDIO BARCELONA, S.L.
Motors, 166-168
08038 Barcelona - Spain
Phone: (+34) 932238403
Email: information@ecler.com
Website: www.ecler.com

Models: IC6CLASS-TR, In-Ceiling High-end Loudspeaker, In-Wall High-end Loudspeaker

File Info : application/pdf, 10 Pages, 573.57KB

PDF preview unavailable. Download the PDF instead.

Ecler IC6CLASS-TR User Manual EN

References

Microsoft Word para Microsoft 365

Related Documents

Preview Ecler IW103 Ceiling Loudspeaker User Manual: Installation & Specifications
Comprehensive user manual for the Ecler IW103 in-ceiling and in-wall high-end loudspeaker. Covers installation, connection, technical specifications, and safety guidelines for optimal audio performance.
Preview Ecler IC6CLASS-54 User Manual: In-ceiling and In-wall High-End Loudspeaker
Detailed user manual for the Ecler IC6CLASS-54, a high-end EN54-24 certified in-ceiling and in-wall loudspeaker. Covers safety instructions, installation, technical specifications, and performance characteristics.
Preview Ecler ePHS30Ti Horn Loudspeaker Technical Data Sheet
Technical specifications and features of the Ecler ePHS30Ti horn loudspeaker, designed for 70/100V applications like paging and background music. Includes key features, technical specifications, applications, and diagrams.
Preview Ecler NIMBO-24 Loudspeaker User Manual
User manual for the Ecler NIMBO-24 high-performance housing loudspeaker, covering safety precautions, warranty, delivery scope, features, connection, impedance selection, equalizer settings, recommended amplifiers, installation, and technical data.
Preview Ecler eCMP8 and eCMP12 Music Projectors User Manual
Comprehensive user manual for Ecler's eCMP8 and eCMP12 specialized loudspeakers (music projectors). Covers introduction, main features, technical specifications, cable connections, location, mounting, and package contents for these durable, high-efficiency audio devices.
Preview Ecler ARQIS108i Architectural Loudspeaker - Technical Specifications
Detailed technical specifications, features, applications, and dimensions for the Ecler ARQIS108i 2-way architectural loudspeaker cabinet, featuring an 8" woofer and 1" compression driver.
Preview Ecler ARQIS112i: Architectural Loudspeaker Cabinet Technical Data Sheet
Technical specifications and overview of the Ecler ARQIS112i, a 2-way wooden architectural loudspeaker cabinet with 500W RMS power handling, 12" woofer, and 1.7" compression driver, designed for permanent installations.
Preview Ecler eMOTUS3OD Commercial Outdoor Loudspeaker User Manual
This user manual provides comprehensive information on the Ecler eMOTUS3OD commercial outdoor loudspeaker, covering installation, connection, safety precautions, technical specifications, and environmental considerations. Learn how to set up and operate your eMOTUS3OD for optimal performance.