Aprilaire Model 8126 Ventilation Control System

Aprilaire Ventilation Control System

Model 8126

A better ventilation solution for today's tighter homes

Aprilaire offers a new market opportunity for profitable ventilation, a cost-effective solution to meet growing ventilation needs, and manages the quantity and quality of air throughout the home.

The system includes the Aprilaire Ventilation Controller and a fresh air damper, designed to manage indoor air quality in modern, tightly constructed homes.

Give builders a better solution to 'build tight and ventilate right'

Builders are constructing tighter homes with energy-efficient windows, doors, thicker insulation, and air-tight vapor barriers. This leads to potential air leaks being sealed, but also traps pollutants inside.

Without proper ventilation, pollutants like formaldehyde, radon, household chemicals, and odors cannot be exchanged for cleaner, fresher outdoor air.

"The real problem is that houses are being built with polluting materials and without provisions for supplying the occupants with fresh air."

— Healthy House Building by John Bower

Builders' options are limited

Current ventilation practices often fail to effectively exchange polluted air when needed or manage incoming air temperature and humidity, often requiring substantial investment.

  • Straight pipe ventilation: Provides fresh air but lacks control over timing, potentially adding excess humidity or causing temperature swings.
  • Barometric dampers: Ventilate only when the HVAC blower operates, offering little to no ventilation during milder weather.
  • 'Timed' dampers: Allow a set amount of ventilation per hour but do not manage air quality, potentially increasing HVAC load and humidity.
  • Energy or Heat Recovery Ventilators: Efficiently exchange air but require a significant upfront investment.

Now, you can offer a better and more profitable way to ventilate

Builders and homeowners need an affordable ventilation system that manages both the quantity and quality of fresh air. The Aprilaire Model 8126 Ventilation Control System, working with an Aprilaire fresh air damper, makes intelligent decisions about ventilation timing and duration.

  • Control over humid air intake: Prevents bringing in air if indoor relative humidity exceeds 60%.
  • Flexible controls and settings: Offer an ideal solution for various home types and sizes.
  • Separate ventilation and cycle time adjustments: Manage incoming air quantity and circulation, ventilating only when necessary to avoid undesirable temperature or humidity levels.

Offer customized control and increase profits

The Aprilaire Model 8126 offers cost-effective ventilation, efficiently managing air exchange for indoor environments and providing builders with an opportunity to satisfy customers without sacrificing profitability.

  • Economical ventilation with temperature control features.
  • Consistent ventilation year-round.
  • Management of both the quality and quantity of fresh air.
  • Fresh air intake when needed, even if the HVAC blower is not running.

The Aprilaire Ventilation Control System complements tight construction, regulatory standards, and consumer demand for comfort, energy savings, and indoor air quality, offering significant market potential for builders.

One system designed to fit different types of homes

The system features two adjustable settings: cycle time and ventilation time within the cycle. This flexibility allows customization to meet the ventilation requirements of any home size.

Graph Description: A graph titled "CFM Required vs. Ventilation Time (minutes)" illustrates ventilation control. The X-axis represents Ventilation Time (minutes) from 0 to 40, and the Y-axis represents CFM Required from 0 to 50. Two lines are shown: "1-hour cycle" and "2-hour cycle". The text explains that with a 120 CFM intake and a 30 CFM requirement, the controller can be set for 15 minutes of ventilation in a 1-hour cycle or 30 minutes in a 2-hour cycle, allowing for proper CFM maintenance based on system needs or homeowner preference.

Ventilates only when necessary

The Aprilaire Model 8126 continuously monitors indoor relative humidity, outdoor temperature, and a user-adjusted timer setting to optimize ventilation.

  • Indoor relative humidity is monitored to prevent high humidity conditions. The controller will not open the damper if it risks raising indoor humidity above 60%.
  • Ventilation is also restricted if the outdoor air temperature is below 0°F or above 100°F, preventing the motorized damper from opening.

Chart Description: A chart illustrates ventilation control based on outdoor temperature and indoor relative humidity. The Y-axis shows Outdoor Temperature (Fahrenheit) from 0 to 100. The X-axis shows Indoor Relative Humidity, with zones marked at 55% and 60%. The chart displays three ventilation states: "No Ventilation Allowed" (below 0°F or above 100°F outdoor temp, or above 60% indoor RH), "Ventilation Based on Time" (between 0°F and 100°F outdoor temp, and between 55% and 60% indoor RH), and "Ventilation with Heat Call Only" (below 55% indoor RH, and between 0°F and 100°F outdoor temp).

Start quoting Aprilaire Ventilation Control Systems today. Call 1-800-334-6011 or visit www.aprilairecontractor.com.

Model 8126 Ventilation Control System

Features

  • Separate ventilation time adjustment
  • Separate cycle time adjustment
  • Minimum off times between cooling call and unsolicited blower call (UBC)
  • 24-Volt control
  • Measures outdoor temperature to stop ventilation at extremely hot or cold outdoor temperatures
  • Measures indoor relative humidity, preventing home indoor RH from exceeding 60%
  • Installation flexibility – ability to override humidity and temperature control

Benefits

  • Controls that satisfy your customers' needs.
  • Allows fan to cycle, increasing air cleaner and humidifier run times.
  • Allows coil to drain before running fan to prevent moisture from being added back into the home.
  • Easy to install, saving you time & money.
  • Increased customer comfort and energy savings over other economical ventilation options.
  • Allows you to meet every application.

Controller Specifications

  • Input (R, C): 18 to 30 VAC, 1 amp maximum
  • Damper Output: 18 to 30 VAC, 1 amp maximum closed contact
  • Temperature Accuracy: ± 2 degrees F
  • Relative Humidity Accuracy: ± 5% RH
  • Cycle Time: 1, 2, 3 or 4 hours (selectable)
  • Ventilation Time: 0-60 minutes

Diagram Description: An image shows the Aprilaire Ventilation Controller Model 8120 with a dial labeled "MINUTES PER CYCLE" and settings from 0 to 60, including "OFF" and "TEST".

Damper Specifications

  • Normally-closed, power open
  • 24 VAC
  • 0.41 amp
  • 2-wire
  • 6" diameter
  • 10-3/4" long
  • Max Static Pressure: 1.0" WC

Intelligent Solutions for Indoor Environments™

An entire line of indoor air quality products designed for intuitive use, performance, and reliability. Aprilaire products enhance comfort, health, and energy efficiency.

  • Zoned Comfort Control
  • Automatic Humidifiers
  • Electronic Thermostats
  • Ventilation
  • High Efficiency Air Cleaners
  • Whole-Home Dehumidifiers

Contact Information:

Research Products Corporation, P.O. Box 1467, Madison, WI 53701-1467. Phone: 800/334-6011. FAX: 608/257-4357.

Form No. 3030 01.07. © 2007 Research Products Corp.

PDF preview unavailable. Download the PDF instead.

Aprilaire 8126 - Specs Sheet Adobe PDF Library 7.0 Adobe InDesign CS2 (4.0.4)

Related Documents

Preview Aprilaire Model 8126 Ventilation Control System Installation and Owner's Manual
Comprehensive guide for installing and operating the Aprilaire Model 8126 Ventilation Control System, including safety instructions, setup procedures, troubleshooting, and warranty information.
Preview Aprilaire Model 8120 Ventilation Controller Owner's Manual
Comprehensive owner's manual for the Aprilaire Model 8120 Ventilation Controller, detailing its principle of operation, operating instructions for setting cycle and ventilation times, control limits based on outdoor temperature and indoor humidity, and warranty information.
Preview Aprilaire Model 8120 Ventilation Controller Owner's Manual
Owner's manual for the Aprilaire Model 8120 Ventilation Controller, providing safety, operating instructions, and warranty information for efficient home ventilation.
Preview Aprilaire Model 8126 Ventilation Control System: Enhance Home Air Quality
Learn how the Aprilaire Model 8126 Ventilation Control System provides optimal fresh air ventilation for tight homes, improving comfort, indoor air quality, and energy efficiency. Features automated controls and flexible settings.
Preview Aprilaire Ventilation Worksheet: Guide to Calculating and Setting Ventilation
Download the Aprilaire Ventilation Worksheet to calculate required ventilation (CFM) based on ASHRAE standards and house characteristics. Learn how to determine system delivery and set your Aprilaire Ventilation Controller for optimal indoor air quality.
Preview Aprilaire Fresh Air Ventilation: Product & Application Guide
A comprehensive guide to Aprilaire's range of fresh air ventilation products, including whole-home ventilators, controllers, and energy recovery ventilators (ERVs), designed for enhanced indoor air quality, comfort, and energy efficiency in residential and light commercial applications.
Preview Aprilaire 8120A & 8126A Digital Ventilation Controller Owner's Manual
Owner's manual for the Aprilaire Model 8120A and 8126A Digital Ventilation Controller, providing safety, operating instructions, and warranty information for optimal indoor air quality.
Preview Aprilaire Model 8120X Digital Ventilation Controller Installation and Operation Manual
This manual provides comprehensive instructions for the installation, setup, operation, and maintenance of the Aprilaire Model 8120X Digital Ventilation Controller, designed to manage whole-house ventilation for improved indoor air quality.