R. STAHL 8530/1-MCB-STA103N-C20-000-4 Line Protection Circuit Breaker

Article Number: 293857

System Components for System Technology

Product: Disjoncteur Disjonct. protection de ligne (Line Protection Circuit Breaker)

The R. STAHL 8530 series line protection circuit breakers offer excellent current limitation for short circuits and high switching capacities of 10, 15, or 25 kA. This ensures minimal stress on lines and high selectivity to upstream fuses. The components are modularly designed and available in 1 to 4-pole versions for nominal currents from 0.5–63 A. The maximum installation capacity is 4.5 partial units (UP).

Key Features:

Technical Characteristics

Explosion Protection

Area of Application (Zones) 1, 2
Area of Application (Zones) Note Usable in Zone 21 / 22 with Ex tb / tc enclosure protection
IECEx Certificate Gas IECEx FMG 19.0029U
IECEx Protection Against Gas Explosion Ex db eb IIC Gb
ATEX Certificate Gas FM19ATEX0191U
ATEX Protection Against Gas Explosion II 2 G Ex db eb IIC Gb
Certificates ATEX (FM), Brazil (ULB), China (CQST), IECEx (FM)
Certificate of Conformity Certificate of Conformity (ATEX)

Electrical Characteristics

Rated Operational Voltage AC 230/400 V
Rated Service Current 20 A
Frequency 50/60 Hz
Rated Service Breaking Capacity 10 kA
Electrical Service Life 2 x 104
Mechanical Service Life 2 x 104
1st Auxiliary Function None
Voltage 1st Auxiliary Function AC -
Max. Current 1st Auxiliary Function -
2nd Auxiliary Function None
Max. Voltage 2nd Auxiliary Function DC -
Tripping Characteristic C
Number of Poles 3 poles + N

Mechanical Characteristics

Ambient Conditions

Ambient Temperature -40 °C ... 70 °C (-40 °F ... 158 °F)
Ambient Temperature Note Different ambient temperatures based on current certificates, on request

Mechanical Specifications

Degree of Protection (IP) (IEC 60529) IP2X
Housing Material Thermoplastic
Minimum Connection Terminal Size 1.5 mm²
Maximum Connection Terminal Size 25 mm²
Minimum Connection Terminal Size AWG 16 AWG
Maximum Connection Terminal Size AWG 4 AWG
Minimum Connection Terminal Size 2 1.5 mm²
Maximum Connection Terminal Size 2 10 mm²
Connection Terminal Size 2 AWG min. 16 AWG
Connection Terminal Size 2 AWG max. 8 AWG
Minimum Tightening Torque 2 N·m
Maximum Tightening Torque 3 N·m
Connection Terminal Note Connection of 2 conductors (upper and lower chamber simultaneously): Upper and lower chamber max. 16 / 10 mm² (Connection can be made with a maximum section difference between the upper and lower chamber.) Permitted combinations of connection terminal sizes are indicated in the operating manual.

Dimensions

Width 110 mm (4.33 in)
Length 165 mm (6.5 in)
Mounting Depth 138.3 mm (5.44 in)

Weight

Weight 1.8 kg (3.969 lb)

Mounting / Installation

Tightening Torque 2–3 N·m (17.7 ... 26.6 lbf·in)
Auxiliary Contact Tightening Torque 0.4–0.6 N·m (3.5 ... 5.3 lbf·in)

Technical Drawings

Tripping Characteristic Curve C

The graph shows the tripping characteristic for a Type C circuit breaker, indicating the relationship between multiples of the rated current and tripping time in seconds and minutes. It is divided into AC and DC curves, with a note indicating the limit from the cold state.

Overall Dimensions (all dimensions in mm [inches])

Diagram showing the external dimensions of the circuit breaker, including width, length, and mounting depth. It indicates the product is 8530/1; 4 division units.

Accessories

Quadruple Locking Device

A locking/unlocking system that allows individual locking of the component using up to 4 cylinder locks.

Description Article Number
Quadruple locking device for individual locking with up to 4 cylinder locks 227232

Fixing Kit

Description Article Number
A fixing kit for mounting the component onto a mounting plate without a DIN rail. 276618

Cylinder Lock

Description Article Number
For locking (shackle Ø 3) 107115

Subject to technical modifications, dimensions, weights, construction types, and delivery possibilities. Figures are for illustrative purposes only.

PDF preview unavailable. Download the PDF instead.

ex-ficha-tecnica-individual-disyuntor-8530-1-mcb-sta103n-c20-000-4-293857-fr-fr-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 8530/1-MCB-STA103N-C20-000-4 Circuit Breaker Technical Data
Technical specifications and features of the R. STAHL 8530/1-MCB-STA103N-C20-000-4 circuit breaker, including explosion protection, electrical data, mechanical data, and accessories. Suitable for use in hazardous areas.
Preview R. STAHL 8530 Series Miniature Circuit Breaker (MCB) - Technical Data and Specifications
Detailed technical specifications for the R. STAHL 8530 series miniature circuit breaker (MCB), model 8530/1-MCB-STA103N-C20-000-4. Includes information on explosion protection, electrical data, mechanical data, ambient conditions, and accessories.
Preview R. STAHL 8530/1-MCB-STA103N-C20-000-4 Miniature Circuit Breaker - Technical Specifications
Detailed technical specifications for the R. STAHL 8530/1-MCB-STA103N-C20-000-4 Miniature Circuit Breaker, including explosion protection, electrical data, mechanical data, and accessories. Suitable for use in hazardous locations.
Preview R. STAHL LS Miniature Circuit Breaker 8530/1-MCB-STA103N-B6-000-4 - Technical Data and Features
Detailed technical specifications and features of the R. STAHL LS Miniature Circuit Breaker, model 8530/1-MCB-STA103N-B6-000-4. Includes information on explosion protection, electrical data, mechanical data, dimensions, and accessories.
Preview R. STAHL MCB Miniature Circuit Breaker 8530/1-MCB-STA103-C63-000-3: Technical Specifications
Detailed technical specifications for the R. STAHL MCB Miniature Circuit Breaker, model 8530/1-MCB-STA103-C63-000-3 (Art. No. 267213). Includes explosion protection, electrical data, mechanical data, ambient conditions, and accessories.
Preview R. STAHL 8530/1-MCB-STA103N-C6-000-4 Line Protection Circuit Breaker
Technical specifications and features of the R. STAHL 8530/1-MCB-STA103N-C6-000-4 line protection circuit breaker, including explosion protection, electrical characteristics, mechanical specifications, and accessories.
Preview R. STAHL 8530/1-MCB-STA103N-B32-000-4 Line Protection Circuit Breaker
Technical specifications and features of the R. STAHL 8530/1-MCB-STA103N-B32-000-4 line protection circuit breaker, including explosion protection, electrical characteristics, mechanical specifications, and accessories.
Preview R. STAHL 8530/1-MCB-STA103N-C10-000-4 Line Protection Circuit Breaker
Technical specifications and features of the R. STAHL 8530/1-MCB-STA103N-C10-000-4 line protection circuit breaker, including explosion protection, electrical characteristics, mechanical specifications, and accessories.