RF Exposure Evaluation

FCC ID: 2A8PV-M2PRO

1.1. Applicable Standard

According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission's guidelines. According to §1.1310 and §2.1093 RF exposure requirement KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies

1.2. Requirement

According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: "Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc."

The formula for SAR test exclusion is: [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] * [f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR.

Where:

The test exclusions are applicable only when the minimum test separation distance is ≥ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.

1.3. Manufacturing Tolerance

Freq. (MHz)Field strength(max)(dBuV/m)EIRP (max) (dBm)
2470MHz90.10-5.16

Note: EIRP=E-104.8+20logD, D=3

Turn-up Power (dB): -5.0 ± 1

Max tune up power (dBm) [P]

Mode: GFSK (Peak)

ChannelTarget (dBm)Tolerance ±(dB)
Channel 0-1.01.0
Channel 19-1.01.0
Channel 39-1.01.0

2. Evaluation Result

Band/Modef (GHz)Antenna Distance (mm)RF output power (dBm)RF output power (mW)SAR Test Exclusion ThresholdSAR Test Exclusion
BLE SRD2.45050.01.00000.3130 < 3.0Yes
2.4505-4.00.39810.1246 < 3.0Yes

3. Conclusion

The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 v06.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=6953262 Microsoft Word 2016 Microsoft Word 2016

Related Documents

Preview FCC Attestation Letter for Shenzhen Information Infinity Co., Ltd. M2PRO Wireless Vertical Mouse
Shenzhen Information Infinity Co., Ltd. provides an FCC attestation letter for their M2PRO Wireless Vertical Mouse (FCC ID: 2A8PV-M2PRO), certifying it is not covered equipment as per FCC rules.
Preview Shenzhen Information Infinity Co., Ltd. U.S. Agent Designation for FCC ID 2A8PV-M2PRO
Designation of AOCE Corporation Inc. as the U.S. agent for service of process for Shenzhen Information Infinity Co., Ltd.'s equipment, FCC ID 2A8PV-M2PRO. Confirms compliance with FCC regulations.
Preview M2PRO Wireless Vertical Mouse User Manual
User manual for the M2PRO Wireless Vertical Mouse by Shenzhen Information Infinity Co., Ltd. Includes setup, operation, and FCC compliance information.
Preview M2PRO Wireless Vertical Mouse Label and Location - FCC ID 2A8PV-M2PRO
Find detailed label and location information for the Shenzhen Information Infinity Co., Ltd. M2PRO Wireless Vertical Mouse, including its FCC ID (2A8PV-M2PRO) and physical dimensions.
Preview Letter of Authorization for FCC ID 2A8PV-M2PRO by Shenzhen Information Infinity Co., Ltd.
This document is a Letter of Authorization from Shenzhen Information Infinity Co., Ltd. authorizing Eurofins Product Service GmbH for equipment authorization matters related to FCC ID 2A8PV-M2PRO, including agreeing to their terms and conditions.
Preview M MONSTER Airmars XKT05 Bluetooth Wireless Headphones User Manual
User manual for the M MONSTER Airmars XKT05 Bluetooth Wireless Headphones, providing setup, operation, features, and safety information.
Preview G06 True Wireless Earbuds User Manual
Comprehensive user manual for the G06 True Wireless Earbuds, covering specifications, operation, pairing, charging, and FCC compliance.
Preview 390RG Antenna: Specifications, Gain, and Radiation Patterns
Detailed technical specifications for the 390RG antenna, including gain, impedance, polarization, and radiation pattern data across 2405MHz, 2451MHz, and 2475MHz frequencies. Provided by Shenzhen Information Infinity Co., Ltd.