HomeSeer HS-LS100+ Z-Wave Leak Sensor
Overview
The HS-LS100+ is a compact, easy-to-install leak sensor designed to control other Z-Wave devices directly or to launch automation events and scenes with Z-Wave certified home controllers.
Applications
- Activate Z-Wave devices, such as sirens or water valve controllers, when a leak is sensed.
- Trigger home automation events (scenes, automations, or robots) when a leak is sensed.
Configuration
The HS-LS100+ is battery-powered and includes a Z-Wave network button, an LED indicator, and a magnetic wall mount/wired probe assembly. The unit can be deployed as a free-standing sensor using its built-in probes or as a wired remote sensor via the wall mount/wired probe assembly.
Z-Wave Network Installation
Remove the back cover by rotating counter-clockwise and install one ER14250 battery (included) inside the HS-LS100+. Include the sensor into your Z-Wave network using the instructions below, then replace the back cover.
Note: The HS-LS100+ can be included into your Z-Wave network as a "secure" or "non-secure" device. Use the instructions below to include or exclude the HS-LS100+ to/from your Z-Wave network.
Secure Inclusion
(Recommended if your home controller supports "S0" or "S2" Z-Wave encryption)
- Put your home controller into Z-Wave 'inclusion' mode.
- Press and hold the Z-Wave network button for 5 seconds, then release it. Wait for the inclusion process to finish.
Non-Secure Inclusion
- Put your home controller into Z-Wave 'inclusion' mode.
- Quickly press and release the Z-Wave network button once. Wait for the inclusion process to finish.
Exclusion
- Put your home automation controller into Z-Wave 'exclusion' mode.
- Quickly triple-press the Z-Wave network button. Wait for the exclusion process to finish.
Reset
(Use this procedure to reset HS-LS100+ to factory settings when the Z-Wave controller is missing or inoperable)
- Press and hold the Z-Wave button for 20 seconds. Release the button once the LED stops blinking and glows solidly.
Physical Installation
Free-standing installation: Simply place the leak sensor on a flat horizontal surface in the area where a leak might occur.
Remote installation: Install the included magnetic wall mount/wired probe assembly in the location of your choice using the supplied mounting hardware. Attach the HS-LS100+ to it by aligning the 3 probes with the 3 holes in the mounting bracket. Position and install the wired probe in the area where a leak might occur or where you wish to detect liquid.
Operation
Leak Sensor Operation
The HS-LS100+ is designed to transmit a Z-Wave command when liquid is sensed. It will also transmit another command when liquid is no longer sensed.
Shock Sensor Operation
The shock sensor is designed to transmit a Z-Wave command when the HS-LS100+ has been physically moved. This sensor is especially helpful in determining whether the unit has been removed from its mount or tampered with.
Battery Sensor Operation
The battery sensor is designed to report battery level with a Z-Wave command every 43200 seconds (12 hours). HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the settings on the Z-Wave tab of the root device.
Z-Wave Association Information
The HS-LS100+ supports Group 1 association. Group 1 reports the sensor's status and battery if running on batteries.
Notes
- If your home controller supports "S2" security encryption, the Leak Sensor may be added as a 'secure' device to your network. If not, it will add as a non-secure device. This will not affect the functionality of the unit.
- For more information, visit homeseer.com.
SmartThings Integration
Please visit https://homeseer.com/smartthings to get started on using HomeSeer products with your SmartThings controller.
Advanced Configuration
Settings are accessible via the "Root device" in a HomeSeer System. Before adjusting these settings, tap the network button 4 times to wake the unit.
Parameter | Settings |
---|---|
14: Enable / Disable Basic Set Command Available: 0=disable, 1=enable Default: 0 | Size: 1 byte | |
15: Set Value for Basic Set Command Available: 0=Sends 255 value when leak sensed Available: 1=Sends 0 value when leak sensed Default: 0 | Size: 1 byte | |
17: Leak Report Interval Available: 0=disable, 1 to 255 (minutes) Default: 5 | Size: 1 byte | |
18: Enable Shock Sensor Available: 0=disable, 1=enable Default: 1 | Size: 1 byte | |
19: Temperature Report Interval Available: 3 to 240 (multiply by 10 for minutes: 3 = 30 min) Default: 144 | Size: 1 byte | Note: Parameter 18 ("Enable Shock Sensor") and parameter 19 ("Temperature Report Interval") are disabled by default to conserve battery life. |
20: Set High Temperature Trigger Value Available: -670 to 2570 (-67 to 257 °F) Default: 1040 (104 °F) | Size: 2 bytes | |
22: Set Low Temperature Trigger Value Available: -670 to 2570 (-67 to 257 °F) Default: 320 (32 °F) | Size: 2 bytes | |
24: Enable Blinking LED When Alarm Triggers Available: 0=disable, 1=enable Default: 1 | Size: 1 byte | |
32: Set Value for Low Battery Available: 10-50 (%) Default: 20 (%) | Size: 1 byte |
Specifications
Attribute | Value |
---|---|
Operating Temp Range | 0°C to 40°C |
Z-Wave Frequency | Range | 908 MHz (US) | Up To 300 Ft line of sight |
Z-Wave Certification | Z-Wave Plus Certified |
Power | Requires (1) ER14250 Battery |
Dimensions (Sensor main unit) | 2.75 x 2.75 x .75 (inches) |
Limited Warranty
HomeSeer Technologies, LLC warrants the device against defects in workmanship or material under normal use for one year from the purchase date in the USA (excluding Alaska and Hawaii). HomeSeer Technologies, LLC will repair or replace defective parts free of charge, provided the device has been operated according to manufacturer guidelines. Customers must return the device to HomeSeer Technologies, LLC for testing and repair or replacement. Contact HomeSeer for return authorization before shipping.
Patents
This product employs features and/or methods covered by U.S. Patent Nos. 6,891,838, 6,914,893, and 7,103,511.