HomeSeer HS-LS100+ Z-Wave Leak Sensor

Overview

The HS-LS100+ is a compact, easy-to-install leak sensor designed to control other Z-Wave devices directly or to launch automation events and scenes with Z-Wave certified home controllers.

Applications

Configuration

The HS-LS100+ is battery-powered and includes a Z-Wave network button, an LED indicator, and a magnetic wall mount/wired probe assembly. The unit can be deployed as a free-standing sensor using its built-in probes or as a wired remote sensor via the wall mount/wired probe assembly.

Z-Wave Network Installation

Remove the back cover by rotating counter-clockwise and install one ER14250 battery (included) inside the HS-LS100+. Include the sensor into your Z-Wave network using the instructions below, then replace the back cover.

Note: The HS-LS100+ can be included into your Z-Wave network as a "secure" or "non-secure" device. Use the instructions below to include or exclude the HS-LS100+ to/from your Z-Wave network.

Secure Inclusion

(Recommended if your home controller supports "S0" or "S2" Z-Wave encryption)

  1. Put your home controller into Z-Wave 'inclusion' mode.
  2. Press and hold the Z-Wave network button for 5 seconds, then release it. Wait for the inclusion process to finish.

Non-Secure Inclusion

  1. Put your home controller into Z-Wave 'inclusion' mode.
  2. Quickly press and release the Z-Wave network button once. Wait for the inclusion process to finish.

Exclusion

  1. Put your home automation controller into Z-Wave 'exclusion' mode.
  2. Quickly triple-press the Z-Wave network button. Wait for the exclusion process to finish.

Reset

(Use this procedure to reset HS-LS100+ to factory settings when the Z-Wave controller is missing or inoperable)

  1. Press and hold the Z-Wave button for 20 seconds. Release the button once the LED stops blinking and glows solidly.

Physical Installation

Free-standing installation: Simply place the leak sensor on a flat horizontal surface in the area where a leak might occur.

Remote installation: Install the included magnetic wall mount/wired probe assembly in the location of your choice using the supplied mounting hardware. Attach the HS-LS100+ to it by aligning the 3 probes with the 3 holes in the mounting bracket. Position and install the wired probe in the area where a leak might occur or where you wish to detect liquid.

Operation

Leak Sensor Operation

The HS-LS100+ is designed to transmit a Z-Wave command when liquid is sensed. It will also transmit another command when liquid is no longer sensed.

Shock Sensor Operation

The shock sensor is designed to transmit a Z-Wave command when the HS-LS100+ has been physically moved. This sensor is especially helpful in determining whether the unit has been removed from its mount or tampered with.

Battery Sensor Operation

The battery sensor is designed to report battery level with a Z-Wave command every 43200 seconds (12 hours). HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the settings on the Z-Wave tab of the root device.

Z-Wave Association Information

The HS-LS100+ supports Group 1 association. Group 1 reports the sensor's status and battery if running on batteries.

Notes

SmartThings Integration

Please visit https://homeseer.com/smartthings to get started on using HomeSeer products with your SmartThings controller.

Advanced Configuration

Settings are accessible via the "Root device" in a HomeSeer System. Before adjusting these settings, tap the network button 4 times to wake the unit.

ParameterSettings
14: Enable / Disable Basic Set Command
Available: 0=disable, 1=enable
Default: 0 | Size: 1 byte
15: Set Value for Basic Set Command
Available: 0=Sends 255 value when leak sensed
Available: 1=Sends 0 value when leak sensed
Default: 0 | Size: 1 byte
17: Leak Report Interval
Available: 0=disable, 1 to 255 (minutes)
Default: 5 | Size: 1 byte
18: Enable Shock Sensor
Available: 0=disable, 1=enable
Default: 1 | Size: 1 byte
19: Temperature Report Interval
Available: 3 to 240 (multiply by 10 for minutes: 3 = 30 min)
Default: 144 | Size: 1 byte
Note: Parameter 18 ("Enable Shock Sensor") and parameter 19 ("Temperature Report Interval") are disabled by default to conserve battery life.
20: Set High Temperature Trigger Value
Available: -670 to 2570 (-67 to 257 °F)
Default: 1040 (104 °F) | Size: 2 bytes
22: Set Low Temperature Trigger Value
Available: -670 to 2570 (-67 to 257 °F)
Default: 320 (32 °F) | Size: 2 bytes
24: Enable Blinking LED When Alarm Triggers
Available: 0=disable, 1=enable
Default: 1 | Size: 1 byte
32: Set Value for Low Battery
Available: 10-50 (%)
Default: 20 (%) | Size: 1 byte

Specifications

AttributeValue
Operating Temp Range0°C to 40°C
Z-Wave Frequency | Range908 MHz (US) | Up To 300 Ft line of sight
Z-Wave CertificationZ-Wave Plus Certified
PowerRequires (1) ER14250 Battery
Dimensions (Sensor main unit)2.75 x 2.75 x .75 (inches)

Limited Warranty

HomeSeer Technologies, LLC warrants the device against defects in workmanship or material under normal use for one year from the purchase date in the USA (excluding Alaska and Hawaii). HomeSeer Technologies, LLC will repair or replace defective parts free of charge, provided the device has been operated according to manufacturer guidelines. Customers must return the device to HomeSeer Technologies, LLC for testing and repair or replacement. Contact HomeSeer for return authorization before shipping.

Patents

This product employs features and/or methods covered by U.S. Patent Nos. 6,891,838, 6,914,893, and 7,103,511.

PDF preview unavailable. Download the PDF instead.

HS-LS100-Manual Microsoft Publisher 2019

Related Documents

Preview HomeSeer HS-LS100+ Z-Wave Leak Sensor - Installation and Configuration Guide
Detailed guide for the HomeSeer HS-LS100+ Z-Wave Leak Sensor, covering installation, Z-Wave network inclusion, exclusion, reset, advanced configuration parameters, specifications, and warranty information.
Preview HomeSeer HS-FS100+ Z-Wave Flex Sensor: Overview, Features, and Specifications
Detailed information on the HomeSeer HS-FS100+ Z-Wave Flex Sensor, a multifunction smart home module with temperature, light, and water detection capabilities. Includes installation, configuration, advanced settings, specifications, and warranty.
Preview HomeSeer HS-DS100+ Z-Wave Door/Window Sensor: Installation and Operation Guide
Detailed guide for the HomeSeer HS-DS100+ Z-Wave Door/Window Sensor, covering setup, inclusion, exclusion, advanced settings, specifications, and warranty. Enhance your smart home automation with reliable Z-Wave technology.
Preview HomeSeer HS-DS100+ Z-Wave Door/Window Sensor: Installation, Features, and Specifications
Learn about the HomeSeer HS-DS100+ Z-Wave Door/Window Sensor. This guide covers installation, operation, Z-Wave network inclusion/exclusion, advanced configuration, specifications, and warranty for smart home automation.
Preview HomeSeer HS-FS100+ Z-Wave Dual Sensor & Buzzer: User Guide and Specifications
Comprehensive guide to the HomeSeer HS-FS100+ Z-Wave Dual Sensor & Buzzer, covering installation, configuration, advanced settings, specifications, and warranty information for smart home automation.
Preview HomeSeer SmartStick+ G3 Z-Wave Interface User Guide
Information on the HomeSeer SmartStick+ G3, a USB Z-Wave interface for smart home automation. Includes installation guides for HomeSeer systems and non-HomeSeer systems, specifications, and warranty information.
Preview HomeSeer HS-FLS100-G2 Floodlight Sensor Z-Wave Conformance
This document details the Z-Wave protocol implementation conformance statement for the HomeSeer HS-FLS100-G2 Floodlight Sensor, including general information, product features, Z-Wave product information, technical details, and supported command classes.
Preview HomeTroller SEL: Setup and Getting Started Guide for Smart Home Automation
This guide provides comprehensive instructions for setting up and using the HomeTroller SEL, a smart home automation controller. Learn how to install hardware, configure networks, manage devices, access remotely via MyHS, and create automation events.