Hach SC200 Universal Controller with Ultrasonic Flow Sensor

Applications: Wastewater, Collection Systems, Industrial Water

The SC200 Universal Controller with Ultrasonic Sensor

The SC200 Universal Controller with Ultrasonic Sensor is designed to provide highly accurate flow and depth measurements for open channel flow monitoring applications. The system offers an economical choice for flow monitoring with reliable data management via SD card transfer.

The flow system is suitable for various applications, including NPDES permitting, storm water monitoring, inlet flow, final effluent, and activated sludge. It replaces the Hach GL153 analog controller with advanced features for enhanced operator usability.

The SC200 controller can be configured for 1 or 2 Digital Sensor Inputs, or 1 or 2 Analog Sensor Inputs, or a combination of both. Communication options include MODBUS RTU and Profibus DPV1.

Maximum Versatility

Display

Data Management

Ultrasonic Flow Sensor

Sensor Inputs

Analog Inputs

4-20 mA Outputs

Digital Communication

Ease of Use and Confidence in Results

Specifications

SC200 General Specifications

FeatureSpecification
DisplayGraphic dot matrix LCD with LED backlighting, Transreflective
Display Size48 x 68 mm (1.89 x 2.67 in.)
Display Resolution240 x 160 pixels
Height x Width x Depth144 x 144 x 181 mm (5.7 x 5.7 x 7.1 in.)
Weight1.70 kg (3.75 lb)
Power Requirements100-240 Vac ±10%, 50/60 Hz; 24 Vdc ±15%
Operating Temperature-20 to 60°C (-4 to 140°F), 0 to 95% RH non-condensing
Storage Temperature-20 to 70°C (-4 to 158°F), 0 to 95% RH non-condensing
Analog Output SignalTwo 0/4 to 20 mA isolated current outputs, max 500 Ω
Operational ModePrimary or secondary measurement or calculated value (dual channel only)
Functional ModeLinear, Logarithmic, Bi-linear, PID
Optional OutputsFour additional 4/20 mA isolated current outputs, max 500 Ω @ 18-24 Vdc (customer-supplied power source)
Security LevelsTwo password protected levels
Enclosure MaterialsPolycarbonate, Aluminum (powder coated), Stainless Steel
Mounting ConfigurationsWall, pole and panel mounting
Enclosure RatingNEMA 4X / IP 66
Conduit Openings1/2" NPT Conduit
RelaysFour electromechanical SPDT (Form C) contacts, 5 A, 250 Vac, 1200W
Operational ModePrimary or secondary measurement, calculated value (dual channel only) or timer
Functional ModeAlarm, Timer, Feeder Control, PWM or FM Control, System Alarm
Digital CommunicationMODBUS RS232/RS485, Profibus DPV1 optional
Memory BackupFlash memory
Electrical CertificationsEMC: CE compliant for conducted and radiated emissions CISPR 11 (Class A limits), EMC Immunity EN 61326-1 (Industrial limits); Safety: General Purpose UL/CSA 61010-1 with cETLus safety mark
Data LoggingSecure Digital Card (Maximum recommended capacity 8 GB) or special RS232 cable connector for data logging and software updates.

Ultrasonic Flow Sensor Specifications

FeatureSpecification
Flow Rate0-9999, 0-999.9, 0-99.99 with selectable flow rate units
Volume0-9,999,999 with selectable volume units
Depth Measurement Range/Resolution0.25 m (10 in.) to 6 m (20 ft.); ±1 mm (0.04 in.)
Air Temperature-40 to 90°C (-40 to 194°F); ±0.1°C (0.18°F)
Input Filter999 sec
Totalizers8-digit resettable LCD software totalizer
Totalized FlowGal., ft.³, acre-ft., lit., m³, in.³
Accuracy±0.5% of span
Repeatability±0.1% of span
Response TimeLess than 180 seconds to 90% of value upon step change
Sensor Cable (integral) Lengths10 m (33 ft.), 20 m (66 ft.), 50 m (164 ft.), or 100 m (328 ft.)
Calibration MethodsCal Depth 1 point; Cal Depth 2 point
Operating Frequency75kHz
ConstructionNEMA 6P (IP68) polybutylene terephthalate (PBT) body with integral temperature sensor
Weight~0.5 kg (1.1 lb)

Select from the Following Gauge Types: V Notch Weir, Rectangle Weir, Rectangle Flume, Round Bot Flume, Cipolletti Weir, Neyrpic Flume, Parshall Flume, P Bowlus Flume, Khafagi Flume, L Lagco Flume, H Type Flume, Trapezoidal Flume, User Defined.

Dimensions

The SC200 controller unit can be installed on a surface, panel, or pipe (horizontally or vertically). No tools are needed to connect the controller unit to any Hach digital sensor. Dimensions are in inches [millimeters].

Minimum Spacing Dimensions for Group Mounting:

[Diagram showing spacing for multiple units]

Mounting Dimensions:

[Diagram showing mounting hole dimensions]

Bottom View:

[Diagram showing bottom view with conduit openings and mounting details]

Note: Designed to accommodate 3/4 x 2-1/2" [19.05 x 63.5 mm] Vertical Pipe / Horizontal Pipe.

Ordering Information

SC200 Controller and Module Smart Part Numbering System

LXV404.99. X X XXX

CategoryOptionOld U53 Sensor
PowerNo power cord0
No power cord Type-O-installed strain reliefs1
With EU power cord installed with cord grip2
With UK power cord installed with cord grip3
With US power cord installed with cord grip5
24VCD power supply with no cord or cord grips7
Communications OutputStandard (two 4-20mA outputs)0
MODBUS 232 & 4851
Profibus DP3
HART + four 4-20mA analog outputs5
Four additional 4-20mA analog outputs9
Sensor Input 1pH & DO1
Conductivity2
Flow3
mA input4
Digital5
Sensor Input 2None0
pH & DO1
Conductivity2
Flow3
mA input4
Digital5
BrandHach2

Ultrasonic Flow Sensors

Part NumberDescription
U53S010Ultrasonic sensor with 10 ft. cable
U53S030Ultrasonic sensor with 30 ft. cable
U53S100Ultrasonic sensor with 100 ft. cable

Accessories

Part NumberDescription
9220600SC200 Weather and Sun Shield with UV Protection Screen
8809200SC200 UV Protection Screen
1000G3088-001Weather Protection Cover
9218200SD card reader (USB) for connection to PC
92181004 GB SD card
9012700Flow Module
9013100Module for 4 additional analog mA out (passive)
9013200Modbus module
YAB104Profibus DP kit
LZX887Data com cable
3004A0017-001Flow sensor mounting kit

Power Cords

Part NumberDescription
9202900SC200 power cord with strain relief, 125 Vac
9203000SC200 power cord with strain relief, 230 Vac, European-style plug

Contact Information

Hach World Headquarters: Loveland, Colorado USA

United States: 800-368-2723 tel | 970-669-5150 fax | hachflowsales@hach.com

Outside United States: 970-622-7120 tel

hachflow.com

Printed in U.S.A. Hach 2022. All rights reserved.

In the interest of improving and updating its equipment, Hach reserves the right to alter specifications to equipment at any time.

Models: SC200 Universal Controller with Ultrasonic Flow Sensor, SC200, Universal Controller with Ultrasonic Flow Sensor, Controller with Ultrasonic Flow Sensor, Ultrasonic Flow Sensor, Flow Sensor, Sensor

File Info : application/pdf, 4 Pages, 520.78KB

PDF preview unavailable. Download the PDF instead.

VM104054

References

Adobe InDesign CS6 (Macintosh) Adobe PDF Library 10.0.1

Related Documents

Preview Hach pH/ORP Module User Instructions
User instructions for the Hach pH/ORP Module, detailing specifications, general information, safety precautions, and installation procedures for connecting analog pH and ORP sensors to a digital SC Controller.
Preview Hach SC4500 Digital Controller: Advanced Water Quality Monitoring
Explore the Hach SC4500 Digital Controller, an advanced solution for water quality monitoring. Learn about its features, technical specifications, applications in wastewater, drinking water, and industrial sectors, and its seamless integration capabilities with Hach's Claros system.
Preview Hach Polymetron 9582 Dissolved Oxygen System with HART Communications
Detailed specifications and features of the Hach Polymetron 9582 Dissolved Oxygen System, a 24 V DC instrument with HART communications for water analytics in the power industry. Includes information on design, installation, operation, maintenance, and technical specifications.
Preview Hach Kick Stand and Hand Strap for Portable HQ Series Meter
Discover the Hach Kick Stand and Hand Strap accessory designed to enhance the usability of the Portable HQ Series Meter. This easy-to-install kit includes a hand strap, kick stand, and screw for improved field support.
Preview Polymetron 9582 Dissolved Oxygen System with MODBUS Communications
Technical specifications and features of the Hach Polymetron 9582 Dissolved Oxygen System, a component of the Hach water analytics system for the Power industry. Includes details on design, installation, operation, maintenance, and technical specifications.
Preview HACH Analog Combination pH/ORP Sensors User Manual
Comprehensive user manual for HACH Analog Combination pH/ORP Sensors, covering specifications, installation, operation, calibration, maintenance, and troubleshooting. Essential guide for accurate pH and ORP measurements.
Preview Hach LDO 2 Next Generation Probe Trade-in Offer
Upgrade to the Hach LDO 2 Luminescent Dissolved Oxygen probe with an exclusive trade-in offer for your old LDO 1 probe. Learn about the benefits of the LDO 2, including no calibration, low maintenance, and advanced connectivity, alongside the SC4500 controller.
Preview HACH SC4500 User Manual: Installation, Operation, and Maintenance
Comprehensive user manual for the HACH SC4500 analytical controller. Covers installation, setup, operation, maintenance, and troubleshooting for optimal performance in process monitoring applications.