An integral part of the most complete water analytics system for the Power industry. Hach provides a broad range of product options designed to work together into flexible solutions to meet your unique needs. The comprehensive approach saves time on design, installation, training, maintenance, and operation.

Key Benefits

Save Time on Design

A single design source and one product platform means you spend less time searching for design files or configuring components. Create and reuse your optimal design templates.

Accelerate Your Installation

One source, interchangeable electronic components, a common user interface, and one support team make installation faster and less complicated. Quickly and easily transfer user settings between dissolved oxygen loops.

Reduce Training Complexity

A single platform minimizes time required to teach and learn product operations, getting new systems in use faster.

Simplify Maintenance and Operation

Common menu guides reduce variability and provide step-by-step procedures for maintenance and calibration. Standard visual alerts across parameters notify operators when troubleshooting is required. Start-up and maintenance time are minimized with pre-mounted membrane cap and factory pre-conditioned sensors.

Specifications

Analogue output functional mode: Linear, Logarithmic, Bi-linear, PID
Analogue outputs: Two (Five with optional expansion module) 0/4 - 20 mA isolated current outputs, max. 550 Ω, Accuracy: ±0.1% of FS (20 mA) at 25 °C, ±0.5% of FS over -20 °C to 60 °C range
Cable length: 10 m (33 ft)
Calibration method: Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
Communication capabilities: Modbus RS232/RS485
Communication: digital: MODBUS RS232/RS485, PROFIBUS DPV1, HART optional
Conduit openings: 1/2" NPT Conduit
Connection drain line: 8 mm tubing
Connections: 1/4" NPT thread (6mm or 1/4" tubing advised)
Detection limit: < 1 ppb
Display: Graphic dot matrix LCD with LED backlighting, transreflective
Display resolution: 240 x 160 pixels
Display size: 48 x 68 mm
Electrical Certifications: EMC, CE compliant for conducted and radiated emissions: CISPR 11 (Class A limits), EMC Immunity EN 61326-1 (Industrial limits)
Enclosure waterproof rating: IP66/NEMA 4X
Flow rate: 66-166
Maintenance interval: Membrane Lifetime: 6 months depending on sample
Manual languages: Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Material: Polycarbonate, Aluminium (powder coated), Stainless Steel
Measurements: 0 to 2000 ppb (0-2 ppm)
Measuring range: 0 - 2000 ppb (0-2 ppm)
Operating temperature range: -20 - 60 °C at 0 - 95% RH (non-condensing)
Power requirements (Hz): 50/60 Hz
Power requirements (Voltage): 100-240 V AC
Relay functions: Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning
Relay: Operational mode: Primary or secondary measurement, calculated value (dual channel only) or timer/scheduler
Relays: Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Repeatability: ± 0.5 ppb or ±5%, whichever is greater
Reproducibility: ± 0.5 ppb or ± 2% whichever is greater
Response time: For step change 1-40 ppb: <30s
Security levels: 2
Storage conditions: -20 °C -70 °C
Temperature compensation: Automatic in the range of 0 - 45 °C (32 - 113 °F)
Units: mg/L, ppm, µg/L, ppb, mbar, hPa, inch Hg, mmHg
Warranty: 24 months
Weight: 3.2 kg
What's included?: Controller, mounting hardware, oxygen sensor, temperature sensor, cable, flow-chamber, basic user manual

PDF preview unavailable. Download the PDF instead.

9582.99.01P4 Apache FOP Version 1.0 Apache FOP Version 1.0

Related Documents

Preview Hach Polymetron 9582 Dissolved Oxygen System with HART Communications
Detailed specifications and features of the Hach Polymetron 9582 Dissolved Oxygen System, a 24 V DC instrument with HART communications for water analytics in the power industry. Includes information on design, installation, operation, maintenance, and technical specifications.
Preview Hach Replacement Oxygen Electrode (ppb) - Product 09182=A=1000
Information on the Hach Replacement Oxygen Electrode (ppb), without probe body. This electrode is a replacement sensor for the Polymetron 9582sc Dissolved Oxygen analyzer. Specifications include material, special notes, temperature sensor, and warranty.
Preview HACH LBOD101 Intellical Luminescent Dissolved Oxygen Sensor User Manual
User manual for the HACH Intellical LBOD101 probe, a digital luminescent dissolved oxygen sensor designed for measuring dissolved oxygen concentration in BOD samples. This guide covers product overview, specifications, safety information, preparation, calibration procedures (100% air-saturated and zero-point), sample measurement, maintenance, troubleshooting, and consumables.
Preview Hach sension6 Portable Dissolved Oxygen Meter Instruction Manual
Comprehensive instruction manual for the Hach sension6 Portable Dissolved Oxygen Meter, covering setup, operation, calibration, maintenance, and troubleshooting for accurate dissolved oxygen measurements in aqueous solutions.
Preview Hach LDO 2 Next Generation Probe Trade-in Offer
Upgrade to the Hach LDO 2 Luminescent Dissolved Oxygen probe with an exclusive trade-in offer for your old LDO 1 probe. Learn about the benefits of the LDO 2, including no calibration, low maintenance, and advanced connectivity, alongside the SC4500 controller.
Preview Hach LDO Sensor User Manual
This user manual provides comprehensive instructions for the Hach LDO Sensor, covering specifications, installation, operation, calibration, and troubleshooting for municipal and industrial wastewater applications.
Preview Met One 6000 Series Particle Counter User Manual
This user manual provides comprehensive information on the Hach Met One 6000 Series Particle Counter, covering specifications, installation, operation, maintenance, and troubleshooting. It details the instrument's features, safety precautions, and configuration options for various applications.
Preview HACH DR1300 FL Portable Fluorometer: Ultra Low Range Chlorine and Sulfite Detection
The HACH DR1300 FL is a portable fluorometer designed for ultra-low range detection of free and total chlorine, and sulfite. Learn about its features, technical specifications, applications, and order information.