REIZEN Talking Digital Thermometer

Model # BT-A31

INSTRUCTIONS

Intended Use

Digital Thermometer, Model # BT-A31 is intended for monitoring human body temperature by physician or consumers in hospital or home.

Operation

  1. When the thermometer is ready to measure the temperature, you will hear audio announcement "Please measure".
  2. When the measurement is complete, you will hear the audio announcement for the measured result.
  3. Press blue audio button again, the latest temperature reading will be announced & displayed on the LCD screen.

Understanding Temperature Readings

What is a "Normal" temperature?

Although the generally accepted "normal" temperature reading is 37.0 °C/98.6°F, temperature readings can vary from 36.1°C/97.0°F to 37.2°C /99.0°F and still may be considered "normal". Variations in temperature can be attributed to activities such as exercise, smoking, eating and drinking. Your temperature is lower in the morning than in the afternoon. Other variations may be due to the location of the temperature reading. While the oral temperature follows the guidelines previously described, a rectal temperature is generally 0.5°C/1.0°F higher. Conversely, an axillary (under the arm) temperature will be 0.5°C/1.0°F lower.

How to switch voice processor announcement between English and Spanish

During POWER OFF mode, press POWER button for about 10 seconds until you see 01 displayed on LCD, then release the POWER button. Continually press POWER button to allow to switch the voice announcement between English and Spanish, 01 means English, 02 means Spanish.

How to switch Celsius and Fahrenheit degrees on display screen

During POWER OFF mode, press POWER button for about 15 seconds until "C" or "F" symbol blinks on LCD display, then release POWER button. Continually press POWER button to allow you to prompt to switch display to either Fahrenheit or Celsius.

Features of your digital thermometer

The thermometer features a distinct Probe Tip designed for temperature measurement. The front side displays a clear Display Window, while the back side houses the Power Button.

Taking a Temperature

Taking an Oral temperature

Place the probe tip under the tongue and keep it near to the heat pocket as close as possible.

Approximate measuring time: 8 seconds.

Suggestion: Close your mouth for at least 2 minutes before taking temperature.

Taking a Rectal temperature

Apply a water soluble lubricant to the probe cover. Gently insert the probe (MAXIMUM 1/2") into the rectum.

Approximate time for measurement: 10-30 seconds.

Note: Rectal temperatures are generally 0.5 C/1.0 °F higher than oral readings.

Replacing the Battery

The battery in your digital thermometer needs to be replaced when you see the [battery-low-icon] appear at the bottom of right corner.

Replace the batteries with 2 CR2025.

To replace the battery

  1. Remove the battery cover from the back of the thermometer.
  2. Remove the plastic security chip from battery compartment.
  3. Use a non-metal pointed tool to remove the battery.
  4. Place battery cover back after the 2 new CR2025 (2*3V) batteries have been replaced.

The battery compartment is located on the back of the thermometer and accommodates two CR2025 batteries.

Note: Please properly discard the batteries. KEEP away from small children and heat.

Specifications

FeatureDetails
Measurement range32.0°C (89.6°F) ~ 42.9°C (109.2°F)
Low temperature displayTemperature<32.0°C (89.6°F): display: Lo°C (Lo°F)
High temperature displayTemperature>42.9°C (109.2°F): display: Hi°C (Hi°F)
Display resolution0.1°C (0.1°F)
Accuracy35.0°C(95.0°F) ~ 39.0°C (102.2°F) ±0.1°C (0.2°F)
other range: ±0.2°C (0.3°F)
Fever beep Sound (>37.8°C (100.0°F))"Tin-Don" then show your measured value [beep-alert]
Normal beep sound (≤37.8°C (100.0°F))"Tin-Don" then show your measured value [beep-alert]
Auto power off8 minutes ± 2 minutes
BatteryCR2025
Life of batteryApproximately 2 years
Operating conditionTemperature: 10°C~40°C (50.0°F to 104.0°F)
Humidity: 30%~85%RH
Storage conditionTemperature: -10°C~60°C (14.0°F to 140.0°F)
Humidity: 25%~90%RH
Weight0.99 ounces (28 grams)

Cleaning Instructions

Each time, before or after using the thermometer, please clean it with a soft cloth that has Isopropyl rubbing alcohol diluted with water or wash it with cold soap and water. The thermometer can not be submersed into water or alcohol. Do not soak or sterilize by boiling, gas or steam autoclaves method.

Dilution with water Method

SolutionMethod
Ethanol 70-80%Wipe the probe with the soaked cloth.
Isopropyl Alcohol 70-90%As above.
Glutaraldehyed 0.5-2%Soak the probe in solution for 30 sec.

Precautions

  1. The thermometer should only be used under the supervision of an adult. Please keep away from children.
  2. Do not walk, run or talk while taking temperature.
  3. Do not keep the thermometer directly exposed in sunshine or any environment with dust, humidity or extreme temperature.
  4. Dropping or subjecting your thermometer with strong shocks should be avoided.
  5. Do not attempt to disassemble the thermometer, except for replacing the battery.

Electromagnetic Compatibility (EMC) Declarations

Guidance and manufacturer's declaration - electromagnetic emission

Emission testComplianceElectromagnetic environment - guidance
RF emissions CISPR 11Group 1The digital thermometer uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emission CISPR 11Class BThe digital thermometer is suitable for use in all establishments, including domestic establishments and those directly connected to public low-voltage power supply networks that supplies buildings used for domestic purposes.

Guidance and manufacturer's declaration - electromagnetic immunity

Immunity testIEC 60601 test levelCompliance levelElectromagnetic environment - guidance
Electrostatic discharge (ESD) IEC 61000-4-2±6 kV contact, ±8 kV air±6 kV contact, ±8 kV airFloors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
Power frequency (50Hz/60Hz) magnetic field IEC 61000-4-83 A/m3 A/mPower frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.

NOTE: UT is the a.c. mains voltage prior to application of the test level.

Guidance and manufacturer's declaration - electromagnetic immunity

Immunity testIEC 60601 test levelCompliance levelElectromagnetic environment - guidance
Conducted RF IEC 61000-4-63 Vrms 150 kHz to 80 MHzNot ApplicablePortable and mobile RF communications equipment should be used no closer to any part of the digital thermometer, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Radiated RF IEC 61000-4-33 V/m 80 MHz to 2.5 GHz3 V/mRecommended separation distance d = 1.2√P 80 MHz to 800 MHz
d = 2.3√P 800 MHz to 2.5 GHz
Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).

Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey.

A. Should be less than the compliance level in each frequency range.

B. Interference may occur in the vicinity of equipment marked with the following symbol: [interference-symbol]

NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

Recommended separation distances between portable and mobile RF communications equipment and the digital thermometer.

Digital thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the digital thermometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the digital thermometer as recommended below, according to the maximum output power of the communications equipment.

Rated maximum output power of transmitter(W)Separation distance according to frequency of transmitter(m)
150 KHz to 80 MHz80 MHz to 800 MHz800 MHz to 2.5 GHz
0.01d = 1,2√P
0.12
d = 1,2√P
0.12
d = 2,3√P
0.23
0.10.380.380.73
11.21.22.3
103.83.87.3
100121223

For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.

NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

Explanation of Symbols

Limited Warranty

REIZEN guarantees that its Digital Thermometer will be free from manufacturing defects under normal use for 1 Year.

This warranty covers only normal use, and does not apply to use in any clinical or commercial applications. This warranty does not cover batteries or other power sources that may be provided with or used with the Digital Thermometer. This warranty is voided if the Digital Thermometer product is misused or abused in any manner.

If the Digital Thermometer fails to operate during the time the original purchaser owns it, please contact Maxi Aids Inc. customer care team at their Toll Free number: 800.522.6694 for further assistance. Repair or replacement of the defective unit, at the warrantor's option, is the sole remedy under this warranty.

ANY IMPLIED WARRANTIES WHICH THE PURCHASER MAY HAVE ARE LIMITED IN DURATION TO THE TIME THAT THE ORIGINAL CONSUMER PURCHASER OWNS THE PRODUCT. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty constitutes the warrantor's only responsibility and obligation to repair and/or replace materials or components, or refund the purchase price. The warrantor will not be responsible for any indirect, incidental, special, consequential, or punitive damages or other loss, including, but not limited to, damage to or loss of other property or equipment and personal injuries, whether to purchaser or others.

The warrantor shall in no event be liable to the purchaser for any amount in excess of the cost of repair and/or replacement of the unit, or the purchase price of the unit. Some states do not allow the exclusive or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Distribution and Customer Care

Distributed By: Fudakang Industrial LLC., Princeton Junction, NJ08550

Customer Care By: Maxi Aids Inc. Toll Free: (800) 522-6294

Models: BT-A31 Talking Digital Thermometer, BT-A31, Talking Digital Thermometer

PDF preview unavailable. Download the PDF instead.

381313 Adobe Acrobat Pro DC (32-bit) 21.1.20149 Adobe Photoshop for Windows -- Image Conversion Plug-in

Related Documents

Preview Reizen Digital Analog Talking Watch Manual
User manual for the Reizen Digital Analog Talking Water-Resistant Watch, covering important notes, operation, setting time and alarms, and battery replacement.
Preview Reizen Atomic Talking Analog Alarm Clock Instruction Manual
Comprehensive instruction manual for the Reizen Atomic Talking Analog Alarm Clock (Item #706810). Learn how to set time, alarms, time zones, use features like talking announcements, and troubleshoot common issues.
Preview Reizen AutoPill Automatic Pill Dispenser User Guide
User guide for the Reizen AutoPill Automatic Pill Dispenser, detailing setup, alarm configuration, medication filling, testing procedures, and time settings for efficient medication management.
Preview Reizen RL-350 Braille Labeler User Manual
User manual for the Reizen RL-350 Braille Labeler, providing instructions on loading tape, imprinting braille characters, cutting tape, and disc maintenance. Learn how to operate your braille labeler effectively.