Thermostat Controls
Time: Displays current time.
Mode: Selects system mode: Heat, Off, Cool, Auto, EM Heat (Emergency Heat).
Menu: Press to access options and start program schedule setup.
Fan: Selects fan mode: Auto, On, Circulate.
Actual indoor temperature: Shows the current indoor temperature.
System status: Indicates system status: Cool On, Heat On, Aux Heat On.
Indoor temperature setpoint: Displays the target temperature. Press [Up Arrow] or [Down Arrow] to adjust.
Temperature/Navigation: Used to increase/decrease temperature setpoint and navigate menus.
Schedule information: Indicates if the thermostat is following a time-based schedule.
System Operation Settings
- Press the [Mode] button to cycle through available System modes (e.g., Heat, Off, Cool).
- Stop when the desired System mode is displayed to activate it.
Fan Operation Settings
- Press/release the [Fan] button to cycle through available Fan modes.
- Stop when the desired Fan mode is displayed.
Fan modes: Auto (fan runs only when heating/cooling is on), On (fan is always on), Circ (fan runs approximately 33% of the time for air circulation).
Set the Time and Date
Set Time
- Press [Menu] on the thermostat.
- Press [Up Arrow] or [Down Arrow] to select TIME, then press [Select].
- Press [Up Arrow] or [Down Arrow] to choose 12 or 24-hour format, then press [Next].
- Press [Up Arrow] or [Down Arrow] to adjust the hour, then press [Next].
- Press [Up Arrow] or [Down Arrow] to adjust the minute, then press [Save & Exit].
Set Date
- Press [Menu] on the thermostat.
- Press [Up Arrow] or [Down Arrow] to select DATE, then press [Select].
- Press [Up Arrow] or [Down Arrow] to choose YEAR, then press [Next].
- Press [Up Arrow] or [Down Arrow] to adjust the MONTH, then press [Next].
- Press [Up Arrow] or [Down Arrow] to choose DATE, then press [Save & Exit].
Alerts and Reminders
When an alert is active, the [Alert Icon] (A) appears on the display with the alert number. When the filter reminder is active, the [Filter Icon] appears with number 181.
Alert | Meaning |
---|---|
405 | Low batteries |
407 | Critically low batteries |
164 | Heat pump has detected a fault |
170 | Thermostat memory failure |
173 | Internal sensor error |
178 | Wired outdoor sensor error |
181 | Replace filter (Reset this timer by pressing Menu. Press Up or Down to find FILT. Press Select, read scrolling text, then press Dismiss to clear the reminder after replacing the filter.) |
To Adjust Program Schedules
- Press [Menu] on your thermostat. Press [Up Arrow] or [Down Arrow] until SCHED is displayed. Press [Select].
- A square appears around ON or OFF. To use a schedule, press [Up Arrow] or [Down Arrow] to select ON. Press [Next] to edit the schedule or [Exit] to leave the menu.
- If editing the schedule, press [Next] to edit the day(s) flashing on the display.
- The word 'Wake' should be flashing. Press [Next]. Press [Up Arrow] or [Down Arrow] to turn this schedule period ON or OFF. Press [Next].
- If the schedule period is set to ON, the time will flash. Press [Up Arrow] or [Down Arrow] to adjust the time for this period. Press [Next].
- The Heat setpoint will flash. Press [Up Arrow] or [Down Arrow] to adjust the Heat setpoint for this period. Press [Next].
- The Cool setpoint will flash. Press [Up Arrow] or [Down Arrow] to adjust the Cool setpoint for this period. Press [Next].
- The display will show the next schedule period flashing. Repeat steps 4-7 for other periods and days.
- Press the [Save & Exit] button.
Troubleshooting
Display is blank
- Check circuit breaker and reset if necessary.
- Ensure power switch at heating and cooling system is ON.
- Make sure furnace door is closed securely.
'Waiting for Equipment' appears on the screen
- Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely without damaging the compressor.
Temperature settings do not change
- If display says 'unlock', the thermostat owner has set a lockout. Verify you are in the correct mode (Heat, Cool, Em Heat, or Auto).