Thermostat Controls
The thermostat display and controls include:
- Display Area: Shows current time, outdoor temperature, or indoor humidity (depending on installer configuration).
- Mode Button: Cycles through system modes: Heat, Off, Cool, Auto, and Emergency Heat (EM Heat).
- Menu Button: Accesses settings and options such as Schedule, WiFi, active alerts, and reminders.
- Fan Button: Controls fan operation: Auto, On, or Circulate.
- WiFi Status Indicator: Shows the status of the Wi-Fi connection.
- System Status Indicators: Displays if the system is currently in Cool On, Heat On, or Auxiliary Heat On mode.
- Schedule Information: Indicates if the thermostat is following a programmed schedule.
- Indoor Temperature Setpoint: The desired temperature, adjustable using the navigation buttons.
- Actual Indoor Temperature: The current measured temperature inside.
- Temperature/Navigation Buttons: Used to increase/decrease the temperature setpoint and navigate through menus.
Note: The message "Waiting for Equipment" may appear during the compressor protection delay period.
The thermostat is compatible with 2.4 GHz or 5 GHz WiFi networks.
System Operation Settings
To change the system mode:
- Press the [Mode] button to cycle through the available system modes (e.g., Heat, Off, Cool, Auto).
- Stop pressing the button when the desired system mode is displayed.
Fan Operation Settings
To change the fan mode:
- Press or release the [Fan] button to cycle through the available fan modes.
- Stop pressing the button when the desired fan mode is displayed.
Available Fan Modes:
- Auto: The fan operates only when the heating or cooling system is actively running.
- On: The fan runs continuously.
- Circulate: The fan runs approximately 33% of the time to circulate air throughout the home.
Setting the Time and Date
Note: If the time and date are set via the internet, only the 12 or 24-hour clock format can be edited.
Setting the Time:
- Press the [Menu] button on the thermostat.
- Navigate to [TIME] using the temperature/navigation buttons and press [Select].
- Choose the 12 or 24-hour clock format using the buttons and press [Next].
- Adjust the hour using the buttons and press [Next].
- Adjust the minute using the buttons and press [Save & Exit].
Setting the Date:
- Press the [Menu] button on the thermostat.
- Navigate to [DATE] using the buttons and press [Select].
- Choose the [YEAR] using the buttons and press [Next].
- Adjust the [MONTH] using the buttons and press [Next].
- Choose the [DATE] using the buttons and press [Save & Exit].
Adjusting Program Schedules
To set or modify your heating and cooling schedules:
- Press [Menu], then navigate to [SCHED] and press [Select].
- A box will appear around [ON] or [OFF]. Select [ON] to use a schedule. Press [Next] to edit or [Exit] to leave the menu.
- If editing, press [Next] to select the day(s) that will flash.
- The [Wake] period should be flashing. Press [Next]. Use the buttons to turn this period ON or OFF, then press [Next].
- If the period is ON, the time will flash. Adjust the time for this period using the buttons and press [Next].
- The Heat setpoint will flash. Adjust the Heat setpoint for this period using the buttons and press [Next].
- The Cool setpoint will flash. Adjust the Cool setpoint for this period using the buttons and press [Next].
- The display will show the next schedule period flashing. Repeat steps 4-7 for all desired periods and days.
- Press the [Save & Exit] button.
Troubleshooting
If you encounter issues with your thermostat, try these solutions:
- Display is blank: Check the circuit breaker and reset if necessary. Ensure the power switch for the heating and cooling system is on. Verify the furnace door is securely closed.
- "Waiting for equipment" appears: This indicates the compressor protection feature is active. Wait approximately 5 minutes for the system to restart safely.
- Temperature settings do not change:
- If the display shows "unlock," a lockout setting has been applied by the thermostat owner.
- Verify you are in the correct mode (Heat, Cool, Auto, or Em Heat).
- If in the correct mode but unable to adjust temperature within the expected range (e.g., Heat 40°F-90°F, Cool 50°F-99°F), range-stops may be set by the installer. Consult your installer.
Important Safety Information
CAUTION: Equipment damage hazard. To prevent possible compressor damage, do not operate the cooling system when the outdoor temperature is below 50°F (10°C).
Regulatory Information
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
For additional FCC information, visit: FCC Information
This device complies with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to two conditions: (1) it may not cause interference, and (2) it must accept any interference, including interference that may cause undesired operation.
RF Exposure Warning: Antennas must be installed at least 20 cm from all persons and not co-located with other transmitters. Operations in the 5150-5250 MHz and 5250-5350 MHz bands are restricted to indoor use only.
Resources
For the full User Manual, search online for "Resideo 33-00694EFS".
Download the First Alert App.