Bristan RS2 SHCDIV C Shower Valve Installation Guide & User Manual

Bristan Installation Instructions & User Guide

Product Code: RS2 SHCDIV C (D4)

Please leave these instructions with the end user.

Specifications

Dynamic Water Pressure: Min: 0.2 bar, Max: 5.0 bar

Maximum Static Pressure: 10.0 bar

Inlet Water Temperature:

  • Cold Water Supply: Min: 5°C, Max: 25°C
  • Hot Water Supply: Up to 65°C

⚠️ IMPORTANT: The inlet hot water must be at least 10°C above the required blend temperature.

Inlet Dimensions: 150 Centres, 15mm Compression

Tools You'll Need

  • Socket Spanner
  • Flat head Screwdriver
  • Drill
  • Adjustable Spanner
  • Pipe Cutter
  • Silicon Sealant
  • Hexagonal Keys
  • Pipe & Wire Detector

Prior to Installation

All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated, and receive regular maintenance in accordance with these instructions.

This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.

  • Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
  • Before installing this product, the water supply must be thoroughly flushed in order to remove any swarf, solder, etc.
  • Full access must be made available for future maintenance/servicing purposes.
  • Before drilling into walls, check that there are no hidden electrical wires, cables, or water supply pipes. This can be checked with the aid of an electronic detector.

If power tools are used, do not forget to: ? Wear eye protection, ? Unplug equipment after use.

This product must not be modified in any way as this will invalidate the guarantee.

If in doubt, contact a registered plumber, your Local Water Authority, or the Secretary of the Institute of Plumbing, address as follows:

The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791

Cavity Dimensions (mm)

  • Cavity Depth: 35mm
  • Concealing Plate Adjustment Range: 30mm

Pack Contents

  • Item 1: x1
  • Item 2: x1
  • Item 3: x2
  • Item 4: x1
  • Item 5: x2
  • Item 6: x1
  • Item 7: x2
  • Item 8: x1

Valve Configuration

⚠️ IMPORTANT: If installed in conjunction with combination boilers, flow regulators must be fitted.

Components: Yellow Flow Limiter (Hot), Green Flow Limiter (Cold).

Step 1: Remove the inlet elbows and filters. Remove the plastic inserts from the valve inlets and insert the flow regulators. Replace the elbows, ensuring the filters are fitted.

Step 2: Screw the shrouds onto the valve.

Installation

Step 1: Install suitable batons (if required) into the cavity. Mark the position of the valve; drill and plug holes to suit. ?️

Step 2: ? REMEMBER: Hot on the left, Cold on the right. Secure the valve using the screws supplied (solid walls only) or a suitable alternative.

Step 3: Connect the inlet pipes ensuring the olives are fitted. Elbows can be pointed up or down. ?

Step 4: Plumb the valve into your chosen outlets.

Step 5: Draw around the concealing plate as a template, measuring in by 10mm to give clearance. Finish the wall surface. Using a silicon sealant, push on the concealing plate and hold firmly until set.

Temperature Adjustment

? REMEMBER: To service your product!

Step 1: Turn the handle to the maximum temperature setting, then remove it.

Step 2: Turn the spindle to increase or decrease the temperature. Check the temperature and adjust until you achieve the desired result.

Step 3: Fit the temperature handle back in the maximum hot position.

Pre-set to 42°C

General Cleaning

Bristan products are made from premium materials, with hand polishing and electroplated finishes.

Your taps or shower should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toiletries, etc., should be rinsed off straight after use.

Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool, or anything similar.

Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts.

Wall Outlet Installation

Choose the location for the wall outlet and create a 25-30mm hole in the wall. Ensure your shower accessories have enough reach from that position. Finish the wall surface.

With rear access

Fit the wall outlet, ensuring the washers are fitted either side of the wall. Go to Step 6 in the Installation Steps.

Without rear access

Follow Step 6 in the Installation Steps, fitting a 1/2" female connection at the hole in the wall (not supplied). Screw the wall outlet into the 1/2" female connection, using a suitable thread sealant, ensuring the rubber seal is fitted to the back of the wall outlet.

Servicing Intervals

To reduce the build-up of lime scale and to ensure this shower works to its maximum performance, we recommend this shower is serviced every 6-12 months depending on the hardness of your water.

Maintenance - Cartridge Cleaning

⚠️ IMPORTANT: Isolate the water supply before starting!

Step 1: Remove the handles. ?️

Step 2: Gently remove the concealing plate from the wall.

Step 3: Unscrew the shrouds. Remove the cartridges and piston.

Step 4: Remove any O-rings and soak all components in de-scaler and wash off in clean water. Examine all seals and replace if needed. Use WRAS approved silicon-based grease on all seals.

Step 5: Reverse the installation steps, ensuring the temperature stop is aligned correctly.

Step 6: Follow the Temperature Adjustment Steps if required.

Operation

  • Left Outlet On/Increased Flow
  • Right Outlet On/Increased Flow
  • Increased Temperature
  • Decreased Temperature

Troubleshooting

Symptom Cause Remedy
No flow or low flow rate Partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too low. Increase water flow rate or pressure through system.
Head of water is below the minimum distance required. Refer to the specification for the minimum distance required.
Are the water supply pressures balanced? If pressures are unbalanced, a pressure reducing valve should be used for optimum performance.
Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes. Do not use other water outlets when using the shower.
Airlock or partial blockage in the supply pipework. Flush through pipework and filters to ensure removal of debris and any airlocks.
Hot/Cold water supply has failed. Check the hot and cold feeds. The shower will not work if either fails.
Maximum Water Temperature too Hot/Cold Maximum Water Temperature needs adjusting. Refer to the Temperature Setting section to set your desired maximum temperature.
Outlet Water Temperature too Hot/Cold Filter/pipe blockage. Flush through pipework and filters to ensure removal of debris and any airlocks.
Installation conditions outside operating parameters. Refer to the specification for the minimum distance required.
Hot water temperature is less than 10°C above the required blend temperature. Adjust hot water temperature or wait for water to reheat if a stored water system is used.
Instantaneous water not igniting because the water flow rate is too low. Increase water flow rate through the system. Refer to the Maintenance section to clean/check the cartridge and filters for any damage. Contact your boiler manufacturer.
Instantaneous water not igniting because the water pressure is too low. Refer to the specification for system requirements. Increase water pressure through the system. Contact your boiler manufacturer.
Only hot/cold water from Shower Valve Inlet water supplies are reversed. Check the water inlet connections are the correct way around: Hot on the left, Cold on the right when viewed from the front. Rework pipework as necessary.
Water dripping from shower Filter/pipe blockage. Flush through pipework and filters to ensure removal of debris and any airlocks.
This is normal for a short time after using the shower. If water continues to drip, possibly due to the cartridge. This is caused by residual water tension, the build up of water in the shower. Remove cartridge and clean, refer to 'Maintenance' section before starting any maintenance.
Shower does not turn on Closed isolation valve. Open isolation valve.
Mains water supply turned off. Turn on mains water supply.

Our Guarantee

At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.

To start your free guarantee, simply scan the QR code and register your product. Alternatively, visit www.bristan.com/register.

For any other queries, please call our Customer Service on 0330 026 6273, where our expert team of advisors will be able to offer you any help and advice.

For full guarantee terms and conditions, visit www.bristan.com/service-centre/guarantees.

Bristan Group Ltd.

UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l., 14 Rue Strachen, 6933 Mensdorf, Luxembourg.

Customer Service: +44330 026 6273

Web: www.bristan.com

Email: enquire@bristan.com

A Masco Company

Models: RS2 SHCDIV C, Renaissance Thermostatic Recessed Dual Control Shower Valve, RS2 SHCDIV C Renaissance Thermostatic Recessed Dual Control Shower Valve, Thermostatic Recessed Dual Control Shower Valve, Recessed Dual Control Shower Valve, Dual Control Shower Valve, Shower Valve

File Info : application/pdf, 2 Pages, 5.03MB

PDF preview unavailable. Download the PDF instead.

RS2-SHCDIV-C-Fitting-Inst

References

Adobe PDF Library 16.0.5 Adobe InDesign 17.1 (Windows)

Related Documents

Preview Bristan SOQ3 SHXAR C (D2) Exposed Sequential and Concentric Mini Valve Shower Installation and User Guide
Comprehensive installation and user guide for the Bristan SOQ3 SHXAR C (D2) exposed sequential and concentric mini valve shower. Includes specifications, pack contents, installation requirements, maintenance, troubleshooting, and safety information.
Preview Bristan KN2 SHXRR C Colonial2 Thermostatic Shower Valve with Rigid Riser Chrome
Technical data sheet for the Bristan KN2 SHXRR C Colonial2 Thermostatic Shower Valve with Rigid Riser Chrome. Includes specifications, features, dimensions, and flow rates.
Preview Bristan Thermostatic Power Shower 1000 Installation and User Guide
Comprehensive installation and user guide for the Bristan Thermostatic Power Shower 1000 (Model HY POWSHX10 W), covering safety, water and electrical requirements, product features, operation, dimensions, specification, installation steps, commissioning, maintenance, troubleshooting, and spare parts.
Preview Bristan Shower Installation & User Guide: Comprehensive Instructions for Various Models
Detailed installation instructions, user guides, troubleshooting tips, and cleaning advice for a range of Bristan shower products, including valve configurations, riser kits, and wall outlets. Covers product specifications, safety information, and maintenance.
Preview Bristan Qubo Bath Filler: Installation & User Guide
Comprehensive installation instructions and user guide for the Bristan Qubo Bath Filler tap (model QB BF C), covering specifications, pack contents, operation, installation steps, maintenance, troubleshooting, and warranty information.
Preview Bristan SI PROSNK C (D3) Sink Mixer: Installation, User Guide & Specifications
Comprehensive installation instructions, user guide, specifications, and troubleshooting for the Bristan SI PROSNK C (D3) sink mixer tap. Learn about safe installation, maintenance, and operation.
Preview Bristan TS4753ECP Thermostatic Mixing Valve: Installation, User Guide, and Maintenance
Comprehensive installation instructions, user guide, commissioning, and maintenance procedures for the Bristan TS4753ECP Thermostatic Mixing Valve. Includes specifications and troubleshooting.
Preview Bristan TMV2 Service Installation Instructions and User Guide
Comprehensive installation instructions and user guide for Bristan's TMV2 Service thermostatic mixing valves, covering general information, conditions of use, commissioning, and in-service testing.