4. INSTALL BLOWER

Installation must be done in accordance with the National Electrical Code® ("NEC®" or NFPA-70®) in the US, the Canadian Electrical Code ("CEC" or CSA C22.1) in Canada, and/or any other local and national installation codes.

1. Refer to the "Select Blower" section (facing page) to ensure that you have the correct blower size for your application.

2. Pressure tests to the system should be done prior to the installation

of the blower. See Warning Section on adjacent page.

Blower

3. Use 2" PVC pipe from the blower to jets or bubblers.

4. Slide Blower onto PVC Pipe. Lower until the stop tabs make contact with the PVC pipe.

5. Blower should be installed vertically, away from direct sunlight.

6. Do not glue or otherwise permanently attach the blower to plumbing.

2" PVC

7. Do not remove the blower check valve diaphragm.

8. Drill two (2) 1/8" pilot holes through the textured fastener safe area

marked on the blower body. The holes should be drilled through the blower

body and PVC pipe. The holes should be oriented 180°

from one another.

9. Install one (1) 1/2" 8-18 thread forming screw into

WARNING

each of the previously drilled pilot holes. The screws and pipe should not interfere with the normal travel of the check valve diaphragm.

Do not use chemical adhesives to affix the blower to the air inlet line. Fumes from chemical adhesives
may accumulate in the piping and

10. The blower also comes equipped with a mounting

explode causing property damage,

bracket which can be used to secure the blower to a

serious injury or death.

vertical surface

such as a wall or

post.

Flat

11. If not used the bracket can be removed and stored.

Diaphragm

Stop Tabs

Fastener Safe Area
1/8" Bit for Pilot Holes

Flexed

Fastener Safe Area
Diaphragm Travel Distance

Blower Body

PVC 180°

Fastener Safe Area

CAUTION
Blower must be affixed to the plumbing using the fasteners recommended in these instructions. Failure to do so may allow the blower to come free of the plumbing during operation which could damage equipment and prevent proper blower operation.
WARNING
Blower must be installed in an area well away from sources of exhaust such as gas pool and spa heater. Please ensure that this blower is installed according to local codes and Authority Having Jurisdiction (AHJ) requirements.

Moutning Bracket

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
WARNING: FOR YOUR SAFETY - This product must be installed and serviced by a contractor
who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist, the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. Turn off all circuit breakers required in order to prevent the possibility of electric shock. If you have any questions or need further details please contact Zodiac Pool Systems Customer Support at: 1.800.822.7933

WARNING: RISK OF ELECTRIC SHOCK - Install at least 5 feet (1.5 m) from tub water
using nonmetallic plumbing. Install blower no less than 1 foot (305 mm) above the maximum water level or with an approved Hartford loop configuration as outlined in section 2 "Plumbing" to prevent water from contacting electrical equipment. Install in accordance with the installation instructions.

To minimize the risk of severe injury or death the To Reduce the Risk of Injury -

appliance should not be subjected to the piping

a) The water in a spa should never exceed 104°F

system pressurization test. Local codes may

(40°C). Water temperatures between 100°F (38°C)

require the pool piping system to be subjected to a and 104°F (40°C) are considered safe for a healthy

pressure test. These requirements are generally not adult. Lower water temperatures are recommended

intended to apply to the pool equipment. Zodiac® for young children and when spa use exceeds 10

pool equipment is pressure tested at the factory. minutes.

However, if the WARNING cannot be followed and pressure testing of the piping system must include the appliance, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS: - Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly

b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).

installed and secured before testing.

c) Before entering a spa or hot tub, the user should

- RELEASE ALL AIR in the system before testing measure the water temperature with an accurate

- Test water pressure must NOT EXCEED 35 PSI. thermometer since the tolerance of water tempera-

- Water temperature for test must NOT EXCEED ture-regulating devices varies.

100°F (38°C).

d) The use of alcohol, drugs, or medication before

Limit test to 24 hours. After test, visually check

or during spa or hot tub use may lead to uncon-

system to be sure it is ready for operation.

sciousness with the possibility of drowning and can

NOTICE: these parameters apply to Zodiac

greatly increase the risk of fatal hyperthermia.

equipment only. For non-Zodiac equipment, consult e) Obese persons and persons with a history of

equipment manufacturer.

heart disease, low or high blood pressure, circula-

Installation must be done in accordance with the

tory system problems, or diabetes should consult a

National Electrical Code® ("NEC®" or NFPA-70®)

physician before using a spa.

in the US, the Canadian Electrical Code ("CEC" or C22.1) in Canada, and/or any other local and national installation codes.

f) Persons using medication should consult a physician before using a spa or hot tub since some medication may induce drowsiness while other

RISK OF ELECTRIC SHOCK, FIRE, PERSONAL medication may affect heart rate, blood pressure,

INJURY, OR DEATH. When required by applicable and circulation.

local codes and/or by the Authority having jurisdiction (AHJ); Connect only to a branch circuit that is protected by a ground-fault circuit interrupter (GFCI).

g) People with infectious diseases should not use a spa or hot tub.

Contact a qualified electrician if you cannot verify that h) Exercise care when entering or exiting the spa

the circuit is protected by a GFCI. Make sure such a or hot tub.

GFCI is provided by the installer and should be tested i) Water temperature in excess of 100°F (38°C)

on a routine basis. To test the GFCI, push the test may be injurious to your health.

button. The GFCI should interrupt power. Push the j) Do not use a spa or hot tub immediately following

reset button. Power should be restored. If the GFCI strenuous exercise.

fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the blower without the test button being pushed, a ground current is flowing,

k) Prolonged immersion in a spa or hot tub may be injurious to your health.

indicating the possibility of electrical shock. Do

l) Do not permit any electric appli-

not use the device. Disconnect the device and

ance (such as a light, telephone,

have the problem corrected by a qualified service

radio, or television) within five 5 feet

representative before using.

(1.5m) of a spa or hot tub.

- To reduce the risk of injury, do not permit

children to use this product. - Jandy Blowers are powered by high-voltage electric motors and must be installed by a licensed

Attention installer: This manual contains important information about the installation, operation and safe use

or - certified electrician or a qualified swimming pool of this product. This information should be given to the

service technician.

owner/operator of this equipment.

- Incorrectly installed equipment may fail, causing

severe injury or property damage. - Do not install on a plumbing line that can be

SAVE THESE INSTRUCTIONS

closed or shut off. The blower may create severe

enough pressures to cause property damage or

injury.

H0507900_REVJ

Installation Instructions
Pool and Spa Air Blower
Models: PSB110 PSB115 PSB120 PSB210 PSB215 PSB220

1. SELECT BLOWER
Correctly sizing the blower for your application is a critical step to the sustained operational quality of your Jandy Pro Series Pool and Spa Blower. Damage or failure due to an improperly sized blower is not covered under warranty.
SIZING WORKSHEETS: The worksheets below will guide you through the proper sizing calculations for your application.

Calculate Back Pressure

a Vertical Measure from Pool/Spa surface to air outlet

a1 Vertical Measure from air outlet to lowest check valve (See Note)

b Number of feet of 2" Pipe

10

c Number of 90° Elbows

.5

d Number of 45° Elbows

.125

e Number of 1/2 lb check valves

4

Calculate back
pressure as a measure
of "inches of water". Verification of this figure can be made by using a manometer.

Spa a a1

d Deck

Blower e
bc

Total Back Pressure
(Inches of Water)

Grade

NOTE: Include a1 for installations with a check valve below the air outlet only. See "Below Grade Installation" on facing page for details. For above grade installations enter 0 for a1.

Calculate Airflow

AIR HOLE CONVERSION

SIZE

FACTOR

1

2.4

8

5 32

1.5

Choose an air hole size from the chart at left and apply the conversion factor in the formula below to determine total airflow in standard cubic feet per minute.

WARNING
Installing an insufficiently sized blower will increase back pressure. Failure to accurately follow the blower sizing calculations

3

1.1

16

1

0.6

4

3 8

0.27

1.2 

0.15

No. of Holes
Conversion Factor Total Airflow

provided could result in excessive back pressure. Excessive pressure can cause damage that could result in electrocution causing severe injury or death.

Jet

0.1

SCFM

(Standard Cubic Feet Per Minute)

Determine Blower Needed

130

Locate the total back pressure, calculated above

120

and draw a horizontal line. Locate the total airflow

110

from previous step and draw a vertical line. These

100

lines will intersect on the performance curve of the

90

minimum HP blower required for your application.

80

Performance Curves (60 HZ)

70 60

Models: PSB110 Models: PSB210

Max Back Pressure 40"

50 40

Models: PSB115 Models: PSB215

Max Back Pressure 50"

30 20

Models: PSB120 Models: PSB220

Max Back Pressure 65"

10

0

Voltage

120V

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
Air Flow Rate (SCFM)

240V

Blower Selection 1.0 HP 1.5 HP
PSB110 PSB115 PSB210 PSB215

2.0 HP PSB120 PSB220

Pressure H2O (Inches of Water)

2. PLUMBING

B(VinelosntwtaulerlairJtieotns

with )

B(BinulosbtwballeelarrtiJoentsw) ith

5' min.

25' max.

STANDARD INSTALLATION

12" min.to water level

Venturi Jet

Check Valve*

Air Line Water Line
Spa Return To Pump

Water Line

Sump Bubbler Jet
* Install a 1/2 lb. U.L. listed check valve between the blower and the jets to prevent water damage to the blower. Ensure that check valves are accessible for servicing.  Do not install adjustable jets. These may cause excessive back pressure.

B(VinelosntwtaulerlairJtieotns

with )

B(BinulosbtwballeelarrtiJoentsw) ith

Over 25 Feet

LONG RUN INSTALLATION
(over 25' from spa wall)

HpaoarcostloflPpo/ssloreupdsmatsoliwbobtohlaaeples.l

Check Valve*

12" min. to water level

Venturi Jet

Air Line Water Line Spa Return

To Pump

Water Line

Air Line

Hartford Loop To install the blower below water level, or if the blower air line drops below the bottom of the spa, use the Hartford Loop plumbing configuration to prevent the air line from filling with water.

2" min. wleavteelr

Blower

CVahlevcek* TPoump

SRpeaturn Water Line

Air Line

Bubbler Jet Sump * Install a 1/2 lb. U.L. listed check valve between the blower and the jets to prevent water damage to the blower. Ensure that check valves are accessible for servicing.  Do not install adjustable jets. These may cause excessive back pressure.
BELOW GRADE INSTALLATION
Water Jet
Bubbler Jet Sump * Install a 1/2 lb. U.L. listed check valve between the blower and the jets to prevent water damage to the blower. Ensure that check valves are accessible for servicing.

3. WIRING

Installation of this equipment should be performed by a licensed electrician and conform to all National Electrical Code® (NEC®), state and local codes.

1. Ensure all power to the blower has been disconnected at the main breaker.
2. Remove blower front door by removing the two (2) screws sliding the door downward and pulling the door free.

Blower Blower Door

3. Pull in voltage source and ground wire from Power Center.

4. Connect wires from power center to
the corresponding wires from the blower
motor. Use the wiring diagrams below for
reference. The 120 or 240 toggle switch Screw will come preinstalled with flag terminals. Connections will need to be made with
Wire nuts.

Wires Conduit

From Power Center

120V Wiring

Power Center Neutral Bus Bar

Line 1 ON

RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before attempting installation, ensure that all power to the device is disconnected/turned off at the circuit breaker. Be careful not to damage or abrade any wiring or other components.
From Blower Motor

Ground Bus Bar
Flex Conduit
LEGEND
Line 1 Neutral Ground

OFF 120V Toggle Switch
From Power Center

240V Wiring

Power Center

Line 1 Line 2

ON

ON

RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before attempting installation, ensure that all power to the device is disconnected/turned off at the circuit breaker. Be careful not to damage or abrade any wiring or other components.
From Blower Motor

Ground Bus Bar

OFF

OFF

Flex Conduit
LEGEND
Line 1 Line 2 Ground

240V Toggle Switch From Power Center

