Roger Technology FIFTHY LED Flashing Light
Model: FIFTHY
Document Revision: IS158 Rev.06 23/02/2023
General Safety Precautions
Warning: Incorrect installation may cause severe damage or injury. Read the instructions carefully before installing the product.
This installation manual is intended for qualified personnel only. ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to improper use or any use other than the intended usage indicated in this manual.
Installation, electrical connections, and adjustments must be performed by qualified personnel, in accordance with best practices and in compliance with applicable regulations. Before installing the product, ensure it is in perfect condition.
Disconnect the mains electrical power before performing any work. Also, disconnect any buffer batteries if present.
Only use original spare parts when repairing or replacing products. Packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as they are a potential source of danger.
Product Description
The FIFTHY is a flashing warning lamp unit connectable to ROGER TECHNOLOGY control units.
Technical Characteristics
Feature | FIFTHY/24 / FIFTHY/24/OR | FIFTHY/230 / FIFTHY/230/OR |
---|---|---|
Mains Power Voltage | 24 Vac/dc | 230 Vac / 115 Vac |
Max Mains Power Absorption | 6.5 W | 4 W |
Operating Temperature | -20°C to +55°C | |
Degree of Protection | IP55 | IP55 |
Note: The FIFTHY flashing lamp unit is assembled with thermosonic bonding technology to ensure an extremely high protection rating. In the event of breakage or malfunction, do not attempt to repair the flashing lamp unit and contact the customer support service or your dealer of choice.
Installation
- Ensure that the surface onto which the FIFTHY flashing lamp unit is to be installed is level, clean, and not subject to vibration.
- Choose the mounting position: Figure 2 - top mounting position; Figure 3 - lateral mounting position.
- Drill the mounting surface with a maximum bit size of 6 mm.
- Assemble the flashing lamp unit with the cable housing base (A) at the bottom, as shown in Figure 2, or facing the wall, as shown in Figure 3.
- Ensure that the cable passage and the mounting base are sealed correctly if the mounting surface is not perfectly even.
- Make the electrical connections as shown in Figure 4 (FIFTHY/230V - FIFTHY/230V/OR) or Figures 5-6 (FIFTHY/24V - FIFTHY/24V/OR).
- If the FIFTHY/230 or FIFTHY/230/OR is used, protect the device with a F200mA (fast) fuse.
- Fasten the flashing lamp unit with screws (B) and commercially available anchor plugs (not included).
Operation
Turn on the power supply.
Select the required flashing mode with parameter 78 on the control unit (except for H70/10CC - 11CC). The default setting is 7800 (flash frequency 1 Hz, 0.5s on, 0.5s off).
If required, set the pre-manoeuvre warning flash function with parameter AS (except for H70/10CC - 11CC).
Disposal
The product may only be uninstalled by qualified technical personnel, following suitable procedures for removing the product correctly and safely. This product consists of numerous different materials. Some may be recycled, while others must be disposed of correctly at specific recycling or waste management facilities indicated by local legislation applicable for this category of product. Do not dispose of this product as domestic refuse. Observe local legislation for differentiated refuse collection, or hand the product over to the vendor when purchasing an equivalent new product. Local legislation may envisage severe fines for the incorrect disposal of this product. Warning! Some parts of this product may contain substances that are harmful to the environment or dangerous and which may cause damage to the environment or health risks if disposed of incorrectly.
Additional Information and Contact Details
ROGER TECHNOLOGY is the exclusive proprietor holder of all rights regarding this publication. ROGER TECHNOLOGY reserves the right to implement any modifications without prior notification. Copying, scanning, or any alterations to this document are prohibited without express prior authorization from ROGER TECHNOLOGY.
ROGER TECHNOLOGY Customer Service:
- Business Hours: Monday to Friday, 08:00 to 12:00 - 13:30 to 17:30
- Telephone: +39 041 5937023
- E-mail: service@rogertechnology.it
- Skype: service_rogertechnology
Declaration of Conformity
The undersigned, as acting legal representative of the manufacturer:
Roger Technology - Via Botticelli 8, 31021 Bonisiolo di Mogliano V.to (TV)
Hereby DECLARES that the appliance described below:
- Description: Flashing light
- Model: FIFTHY
Is conformant with the legal requisites of the following directives:
- 2014/30/EU;
- 2014/35/EU;
- 2011/65/CE
And that all the standards and/or technical requirements indicated as follows have been applied:
- EN 61000-6-3;
- EN 61000-6-2
Last two figures of the year in which CE marking was applied: 16.
Place: Mogliano V.to
Date: 20/12/2016
Signature: [Signature]