V-ZUG Heat Pump Dryer Installation Instructions
Model: 1068340-05
For: One-family household
General Safety and Validity
⚠️ The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
⚠️ Check the appliance for visible damage. Do not use the appliance if it is damaged in any way.
⚠️ The appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by a utility.
Validity: The installation instructions apply to the models: 12011–12013
Transport
⚠️ Transport the appliance in an upright position only! Transporting it in any other position will result in damage to the appliance!
When carried carefully without being shaken, the appliance may be tilted a maximum of 90° to the left (viewed from the front).
[Diagram: Illustration showing correct upright transport of the appliance, with an indication that it can be tilted up to 90° to the left when carried carefully.]
Identification Plate
1. Open the appliance door.
The identification plate 1 is located bottom right.
[Diagram: Illustration of the appliance with an arrow pointing to the location of the identification plate, indicated as being at the bottom right.]
Supplied Installation Accessories
The necessary installation accessories are located in the washing drum and in the appliance packaging.
Designation | Article no. | Number | See installation step |
---|---|---|---|
Installation plate (incl. double-sided adhesive tape) | W40653 | 1 | 2. Positioning the installation plate |
Tower panel | W55687 | 1 | 2. Positioning the installation plate |
Condensate drain set (incl. screw material) | W56298 | 1 | 6. Connecting condensate drain |
Room Size, Room Climate and Ventilation
⚠️ Keep all ventilation slits on the appliance clear and unobstructed. Otherwise an adequate supply of air is not guaranteed.
Ventilate the room well. Ensure that the temperature of the room is between 5–35 °C.
The room temperature must be kept between the range of 15–25 °C to ensure the economic running of the appliance.
Room size <10 m² (<20 m³)
Room must be ventilated: There must be air inlet and outlet openings to the adjacent room or to the outside, e.g. open window/door, ventilation grille or slits in the door or ventilation system.
Room size ≥10 m² (≥20 m³)
Condensation may form on thermal bridges! The room must therefore be aired after running several consecutive drying programmes, e.g. by opening a window or door to the room.
1. Dimensions
The stated dimensions do not include distances from walls. To prevent disturbing noise and vibration the appliances must not come into contact with the surrounding walls of their installation location.
[Diagram: Technical drawing showing the appliance's external dimensions, including width (595 mm), depth (550 mm), and height (850 mm). It details the positions and dimensions for the cooling air inlet (1), cooling air outlet (2), installation plate (3), tower panel (4), mains connection cable (5) with length (1.8 m), and condensate drain (6) with connection diameter (Ø10.5 mm) and maximum pumping height (≤1200 mm). It also shows clearance space requirements for door opening (180°), indicating 1200 mm clearance across the whole width of the front.]
- 1 Cooling air inlet
- 2 Cooling air outlet
- 3 Installation plate
- 4 Tower panel
- 5 Outlet mains connection cable, length: 1.8 m, with plug
- 6 Condensate drain: Drain connection: Ø10.5 mm. Pumping height of drain pump from floor: ≤1200 mm. Condensate water drain hose, length: 2.5 m
2. Positioning the Installation Plate
General tips
Use the installation plate supplied to install the appliance. It fixes the appliance in position, and is for use with both free-standing appliances and appliances positioned in a niche.
⚠️ In case of underfloor heating, do not drill holes in the floor! Adhere installation plate into place!
[Diagram: Illustration showing the installation plate with spacers (D) folded out to maintain distance from the back wall.]
Variant 1: Without underfloor heating:
- Fasten installation plate to the floor with 3 screws.
- Dampen mounting slots E with water to make the appliance easier to push in.
Variant 2: With underfloor heating:
- Holes must not be drilled in the floor if the room has underfloor heating. The installation plate must be adhered to the floor.
- Dampen mounting slots E with water to make the appliance easier to push in.
⚠️ When installing the washer-dryer tower, do not drill any holes in the washing machine! Adhere installation plate into place!
[Diagram: Illustration depicting a tumble dryer being installed on top of a washing machine, with the installation plate adhered to the floor.]
Washer-Dryer Towers
⚠️ Failure to use the correct installation plate can result in damage to the appliance!
Use the installation plate supplied to install the washing machine. The use of an unsuitable installation plate or a soft, sound-insulating underlay can cause damage to the appliance which does not fall within the scope of the manufacturer's guarantee.
For Tumble dryers (Models: 12011–2013) and Washing machines (Models: 11001–11006, 11010–11014, 11021, 11023, 11025)
[Diagram: Step-by-step illustrations for attaching the installation plate and tower panel for a washer-dryer tower setup. Step 1 shows adhering the installation plate (S) to mounting surfaces (K) using double-sided tape. Step 2 shows turning over the plate and adhering it to the washing machine cover plate. Step 3 shows taking the tower panel from the dryer and installing it onto the plate.]
For Tumble dryer (Models: 12011–2013) and Washing machine (Models: 265, 266, 268, 269)
[Diagram: Step-by-step illustrations for attaching the installation plate and tower panel for a washer-dryer tower setup, involving positioning cams (P) and adhesive tape (S) on mounting surfaces (B).]
Positioning in a Niche
If a tumble dryer or a washer-dryer tower is installed in a niche, a 130° door stop must be provided (article no. W54086).
If the niche is fitted with a door, it must be ensured that the door is left open for the duration of the process. The niche door and the appliance door must be hinged on the same side.
[Diagrams: Illustrations detailing the required dimensions for installing the appliance in a niche, including back wall distance (≥45 mm), cut-out for lateral connections (≥100 × 100 mm), and minimum niche heights for tumble dryers (≥860 mm) and washer-dryer towers (≥1710 mm).]
Variant 1: Tumble dryer door C is flush with niche front B:
- Niche depth A ≥605 mm
- Installation offset for installation plate D = 50 mm
Variant 2: Washing machine door C is flush with niche front B:
- Niche depth A ≥645 mm
- Installation offset for installation plate D = 83 mm
⚠️ The condensed water hose must not be crushed between the rear of the appliance and the building wall.
Free-standing Position
If a tumble dryer and a washing machine are positioned side by side, keep a distance of min. 5 mm between the installation plates and to the walls at the side and min. 45 mm to the back wall. The installation plates for the washing machine and tumble dryer are the same.
[Diagram: Illustration showing the side-by-side placement of a tumble dryer and washing machine, indicating minimum clearance distances to walls and between appliances.]
[Diagram: Illustration showing the installation plate with spacers (D) folded out to maintain distance from the back wall. Note: Dimensions 45 and 555 apply only if no plumbing fittings are installed behind the appliance.]
3. Inserting the Ventilation Grille
The heat given off from the rear of the appliance must be conducted out of the niche.
- Insert 2 ventilation grilles P33002 or ensure a ventilation cross-section of min. 400 cm².
- Ensure there is a supply of fresh air via the connection opening.
[Diagram: Illustration showing the placement of ventilation grilles or required ventilation cross-section (minimum 400 cm²) for heat dissipation, with minimum dimensions for height (≥860 mm) and width (≥50 mm) for ventilation openings.]
⚠️ The condensed water hose must not be crushed between the rear of the appliance and the building wall.
4. Levelling
⚠️ To ensure fault-free operation, the appliance must stand level with all 4 feet firmly on the installation plate and not wobble.
[Diagram: Illustration showing the levelling process using the appliance's adjustable feet and a spirit level (L) to ensure stability.]
- Roughly adjust the height of the front and rear adjuster feet.
- Use a spirit level L to level the appliance.
- Slide the appliance onto the installation plate.
- Finely adjust the front adjuster feet.
- The appliance must not wobble!
5. Electrical Connections
⚠️ Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installations.
Use at altitude: Electrical safety is guaranteed up to 2,000 m above sea level.
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
⚠️ The mains plug must not be cut off.
Connection cable: Valid for all washing machines and tumble dryers in the Adora, AdoraWash and AdoraDry model range.
⚠️ The mains cable may only be replaced by the manufacturer, its Customer Services or a similarly qualified person.
Error messages «U1»: Disconnect the appliance from the mains and control the wiring.
6. Connecting Condensate Drain
Fastening the Drain Hose
⚠️ When installing the drain hose, protect it against damage and kinks!
Fasten the drain hose before plugging in the mains cable.
[Diagram: Step-by-step illustrations showing how to fasten the drain hose to the appliance. Step 1: Remove pump cover A. Step 2: Fasten drain hose B to nozzle D using hose clip C. Step 3: Put back pump cover A. Step 4: Fix drain hose B to the two lugs E with cable ties. Plug in the mains cable.]
Connecting Condensate Drain
⚠️ The drain hose for the tumble dryer must not be lengthened!
Otherwise water from the drain hose of the tumble dryer can flow into the condensate tank of the tumble dryer when the condensate pump is switched off.
⚠️ Never connect the drain hose from a tumble dryer to the drain hose from a washing machine so that it is watertight (hydraulically)!
Otherwise water from the drain hose of the washing machine can flow into the condensate tank of the tumble dryer!
⚠️ Do not immerse the end of the drain hose from the tumble dryer in the water in the drain trap!
Otherwise water in the drain-trap bend can flow into the condensate tank when the condensate pump is switched off.
Single connections
Drainage into fixed upright outflow pipe (W56298)
[Diagram: Illustration showing connection into a fixed upright outflow pipe with a drain trap (U). Details include maximum pumping height of 1200 mm. Instructions: Use an open-top fixed upright outflow pipe with the drain trap. Leave a gap of ≥5 cm between the end of the drain hose and the water level. Position the drain hose above the overflow line U. Do not exceed maximum pumping height.]
Connection to sink drain trap (W53070)
[Diagram: Illustration showing connection to a sink drain trap. Details include maximum pumping height of 1200 mm. Instructions: Use an open-top fixed upright outflow pipe with the drain trap. Leave a gap of ≥5 cm between the end of the drain hose and the water level. Position the drain hose above the overflow line U. Do not exceed maximum pumping height.]
Tumble dryer positioned next to washing machine (open-top fixed upright outflow pipe)
Fixed upright outflow pipe with separately routed drainage pipe
[Diagram: Illustration showing connection to an upright outflow pipe with a separately routed drainage pipe. Details include maximum pumping height of 1200 mm. Instructions: Use an open-top fixed upright outflow pipe with the drain trap. Leave a gap of ≥5 cm between the end of the drain hose and the water level. Insert the drain hoses from both appliances into the riser pipe of the drain trap. Position the drain hose above the overflow line U. Do not exceed maximum pumping height.]
Fixed upright outflow pipe with combi drainage set (W55969)
[Diagram: Illustration showing connection to an upright outflow pipe with a combi drainage set. Details include maximum pumping height of 700 mm. Instructions: Use an open-top fixed upright outflow pipe with the drain trap. Leave a gap of ≥5 cm between the end of the drain hose and the water level. Insert the drain hoses from both appliances into the riser pipe of the drain trap. Position the drain hose above the overflow line U. Do not exceed maximum pumping height.]
Tumble dryer positioned next to washing machine (GEBERIT concealed drain trap)
⚠️ Cannot be connected to a concealed double drain trap! There must be a separate concealed drain trap for each appliance.
- Washing machine: Use concealed drain trap GEBERIT UP Y (GEBERIT art. no. 152.236.00.1).
- Tumble dryer: Use concealed drain trap GEBERIT UP X (GEBERIT art. no. 152.237.00.1).
[Diagram: Illustration showing a cross over a double drain trap and separate traps for washing machine and tumble dryer, indicating specific GEBERIT models.]
Washer-dryer towers
Fixed upright outflow pipe with separately routed drainage pipe
[Diagram: Illustration showing condensate drain connection for washer-dryer towers, indicating connection to a concealed double drain trap. Details include maximum pumping height of 700 mm.]
Fixed upright outflow pipe with combi drainage set (W55969)
[Diagram: Illustration showing condensate drain connection for washer-dryer towers, indicating connection to a concealed double drain trap. Details include maximum pumping height of 700 mm.]
7. Using for the First Time
When the appliance is connected to the power supply for the first time, it is possible to carry out a function test. The purpose of the function test is to check the installation. It takes about 3 minutes. As the heat pump is not tested, the function test can be started immediately after installation. It cannot be aborted by interrupting the power supply. Once the function test has been run or aborted, it can no longer be selected and the appliance enters the normal operating mode.
Carrying out the function test
- Insert plug into mains socket.
- In the display appears: «Language: English»
- Select language for function test. Touch OK.
- Appliance is ready for function test.
- In the display appears: «Function test - Start with button ▶️» Skip with button ⏩
- To start the function test, touch ▶️.
- The function test starts.
- In the display appears: «Function test 0h03»
Interrupting the function test
- To interrupt the function test, touch ▶️.
- In the display appears: «Function test - Continue with button ▶️» Abort with button ⏩
- To continue the function test, touch ▶️.
Aborting/Skipping the function test
- To abort or skip the function test, touch ⏩.
Select the user language, see the operating instructions.
Select viewing angle, see the operating instructions.
Select V-ZUG-Home mode, see the operating instructions.