DocumentDocumentBAC-9000A Series BACnet VAV Controller-Actuators (B-AAC) DESCRIPTION KMC ConquestTM BAC-9000A series controller-actuators are designed to operate VAV (Variable Air Volume) terminal units. The integrated alarming, scheduling, and trending enable these BACnet Advanced Application Controllers to be powerful edge devices for the modern smart building ecosystem. With integrated actuators, internal air pressure sensors, and other powerful features, they are ideal for new installations and upgrades of less-efficient equipment. They easily mount to terminal boxes by securing a "V" clamp on the shaft and securing a single-screw anti-rotation bracket. The factory-supplied programming covers common VAV applications. The controllers feature simple, menu-driven setup choices using an STE-9000 series digital sensor, which can be installed permanently as the room sensor or used temporarily as a technician's service tool. Alternately, quick configuration of controller properties can be done using NFC (Near Field Communication) from a smart phone, tablet, or computer (using KMC Connect LiteTM app) while the controller is unpowered. For demanding building automation custom requirements, these controllers are also fully programmable. Custom configuration and programming, with wizards for application programming selection/ configuration, are enabled by KMC ConnectTM software and the KMC ConvergeTM module for Niagara Workbench. KMC Converge and TotalControlTM software additionally provide the capability of creating custom graphical web pages (hosted on a remote web server) to use as a custom user-interface for the controllers. MODEL (BAC-9001ACE with Ethernet/IP shown) APPLICATIONS Application options include: · Pressure independent or dependent VAV · Cooling only and with changeover · Staged, modulated, floating, or time-proportional reheat · Series or parallel fan control · Dual duct (with TSP-8003 actuators) · CAV (Constant Air Volume) For installations with a BACnet building automation system, these easily integrated controllers signal demands for higher static duct pressure, cooler or warmer supply air, and other diagnostics for AHU optimization. (See also Sample Installation on page 6.) APPLICATIONS Pressureindependent VAV, cooling/heating with fan and reheat; CAV INPUTS OUTPUTS FEATURES Air Pressure Sensor Real Time Clock MS/TP Ethernet MODEL 8 total: 9 total: · 1 internal actuator position · 2 internal triacs feedback (actuator motor · 1 integrated air pressure control) sensor · 4 external triacs · 2 analog (temperature sensor (terminals) port) · 3 universal outputs · 4 software-configurable uni- (012 VDC on versal inputs (terminals) terminals) BAC-9001AC BAC-9001ACE KMC Controls, 19476 Industrial Drive, New Paris, IN 46553 / 877-444-5622 / Fax: 574-831-5252 / www.kmccontrols.com SPECIFICATIONS B C A D DIMENSIONS TERMINAL COLOR CODE A 7.605 inches B 4.374 inches C 0.830 inches D 2.150 inches 193 mm 111 mm 21 mm 55 mm Black 24 VAC Power Gray MS/TP Communications Green Inputs and Outputs E 5.891 inches 150 mm (Optional) EOL Switch, E MS/TP Terminal Block, and Network Bulbs Actuator "V" Clamp Gear Disengagement Lever (Optional) Differential Air Pressure Port Removable Screw Terminals: Power, Outputs, Inputs NFC Target Anti-Rotation Bracket (Clearance for #8 Screw) (BAC-9001AC with MS/TP shown) Inputs and Outputs Inputs, Universal (4 on Terminal Blocks) Universal inputs Termination Resolution Protection Wire size Configurable as analog, binary, or accumulator objects 1K and 10K ohm sensors, 012 VDC, or 020 mA (without need for an external resistor) 16-bit analog-to-digital conversion Overvoltage protection (24 VAC, continuous) 1224 AWG, copper, in removable screw terminal blocks Input, Dedicated Room Sensor Port Connector Cable Modular connector for STE-9xx1 series digital wall sensors or STE6010/6014/6017 analog temperature sensors Uses standard Ethernet patch cable up to 150 feet (45 meters) Input, Integrated Air Pressure Sensor (optional) pressure range Sensor accuracy Connections 0 to 2" wc (0 to 500 Pa) ±4.5% of the reading or (when near zero) 0.0008" wc (0.2 Pa), whichever is greater (@ 25° C); internally linearized and temperature compensated Barbed for 1/4 inch FR (Flame Retardant) tubing Outputs, Universal (3 on Terminal Blocks) Universal outputs Power/protection Resolution Wire size Configurable as an analog (0 to 12 VDC) or binary object (0 or 12 VDC, on/off) Each short-circuit protected universal output capable of driving up to 100 mA (at 012 VDC) or 100 mA total for all outputs 12-bit digital-to-analog conversion 1224 AWG, copper, in removable screw terminal blocks 2 Outputs, Triac (4 Binary) Triac outputs Power Wire size Optically isolated zero-crossing triac output configured as a binary object Maximum switching 24 VAC at 1.0 A for each output; maximum total for controller is 3.0 A 1224 AWG, copper, in removable screw terminal blocks Output, Integrated Actuator Torque Angular rotation Motor timing Shaft type/size Noise level 40 in-lb. (4.5 N·m) 0 to 95°; adjustable end stops at 45 and 60° rotation 90 sec. for 90° at 60 Hz; 108 sec. for 90° at 50 Hz Mounts on round or square damper shafts--see Enclosure and Mounting on page 4 <35 db(A) @ 1 meter (3.3 feet) Communication Ports MS/TP (optional) Ethernet (optional) NFC Room sensor Auxiliary One EIA-485 port (removable terminal block) for BACnet MS/TP, operating at 9.6, 19.2, 38.4, 57.6, 76.8, or 115.2 kilobaud; max. length of up to 4,000 feet (1,200 meters) of 18 AWG shielded twisted-pair, no more than 51 pf/ft (167 pf/m); use repeaters for longer distances On "E" model only, two 10/100BaseT Ethernet connectors for BACnet IP, Foreign Device, and Ethernet 802.3 (ISO 8802-3); segmentation supported; up to 328 ft (100 m) between controllers (using T568B Category 5 or better cable) NFC (Near Field Communication) up to 1 inch (2.54 cm) from the top of the enclosure Modular STE connection jack for STE-9000A series digital sensors and STE-6010/6014/6017 analog sensors One serial port with mini Type B connector (reserved for future use) Configurability OBJECTS* Inputs and Outputs MAXIMUM # Analog, binary, or accumulator input 8 Analog or binary output 9 Values Analog value 120 Binary value 80 Multi-state value 40 Program and Control Program (Control Basic) 10 PID loop 10 Schedules Schedule 2 Calendar 1 Logs Trend log 20 Trend log multiple (must be created) 4 (default 0) Alarms and Events Notification class 5 Event enrollment 40 *Configuration allows creation and deletion of objects (maximum number of objects shown). The number and configuration of default objects depends on the selected application. For lists of default objects, see the KMC Conquest Controller Application Guide. See also the PIC statement for all supported BACnet objects. 3 Configuring, Programming, and Designing SETUP PROCESS Config- Programming Web Page uration (Control Basic) Graphics* KMC CONTROLS TOOL Conquest NetSensor Internal configuration web pages in Conquest Ethernet "E" models** KMC Connect LiteTM (NFC) app*** KMC ConnectTM software **** **** TotalControlTM software KMC ConvergeTM module for Niagara WorkBench KMC Converge GFX module for Niagara WorkBench *Custom graphical user-interface web pages can be hosted on a remote web server, but not in the controller. **Conquest Ethernet-enabled "E" models with the latest firmware can be configured with an HTML5-compatible web browser from pages served from within the controller. For information, see the Conquest Ethernet Controller Configuration Web Pages Application Guide. ***Near Field Communication via enabled smart phone or tablet running the KMC Connect Lite app. ****Full configuration and programming of KMC Conquest controllers is supported starting with TotalControl ver. 4.0. Hardware Features Processor, Memory, and Clock Processor Memory RTC 32-bit ARM® Cortex-M4 Programs and configuration parameters are stored in nonvolatile memory; auto restart on power failure Real time clock with (capacitor) power backup for 72 hours ("C" model only) for network time synchronization or full stand-alone operation Indicators and Isolation LED indicators MS/TP protection Switch Power/status, MS/TP communication, and Ethernet status One network bulb assembly indicates reversed polarity and isolates circuit EOL (end of line) for MS/TP Installation Power Supply voltage Required power Wire size 24 VAC (15%, +20%), 50/60 Hz, Class 2 only; non-supervised (all circuits, including supply voltage, are power limited circuits) 8 VA, plus external loads 1224 AWG, copper, in a removable screw terminal block Enclosure and Mounting Weight 1.17 lb. (0.53 kg) Case material Green and black flame retardant plastic Mounting Directly mounts on 3/8 to 5/8 inch (9.5 to 16 mm) round or 3/8 to 7/16 inch (9.5 to 11 mm) square damper shafts with 2 inch (51 mm) minimum shaft length Environmental Limits Operating Shipping Humidity 32 to 120° F (0 to 49° C) 40 to 160° F (40 to 71° C) 0 to 95% relative humidity (non-condensing) Warranty, Protocol, and Approvals Warranty KMC Limited Warranty 5 years (from mfg. date code) BACnet Protocol Standard Type Meets or exceeds the specifications in ANSI/ASHRAE BACnet Standard 135-2010 for Advanced Application Controllers BTL-certified as a B-AAC controller type 4 Regulatory Network Communications UL BTL RoHS 2 FCC UL 916 Energy Management Equipment listed BACnet Testing Laboratory listed as Advanced Application Controller (B-AAC) RoHS 2 compliant FCC Class A, Part 15, Subpart B and complies with Canadian ICES-003 Class A* *This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. (NFC operation meets FCC compliance while the controller is in an unpowered state.) BAC-5051AE HPO-0055 HPO-5551 HPO-9003 HSO-9001 HSO-9011 HSO-9012 KMD-5567 BACnet router with single MS/TP and IP/Ethernet ports Replacement network bulb assembly (pack of 5) Router technician cable kit NFC Bluetooth/USB module (fob) Ethernet patch cable, 50 feet Ethernet patch cable, 50 feet, plenum rated Ethernet patch cable, 75 feet, plenum rated Network surge suppressor Room Sensors, Analog ACCESSORIES NOTE: For accessory details, see the respective product data sheets and installation guides. DAT Sensor and Dual Duct Actuator STE-1405 TSP-8003 Discharge air temperature sensor with 10-foot plenum-rated cable Tri-state actuator with pressure sensor for dual-duct applications Differential Air Pressure Sensors SSS-1012 SSS-1013 SSS-1014 SSS-1015 Sensor, 3-5/32 inches (80 mm) length Sensor, 5-13/32 in. (137 mm) length Sensor, 7-21/32 in. (194 mm) length Sensor, 9-29/32 in. (252 mm) length STE-6010W10 STE-6014W10 STE-6017W10 HPO-9005 Temperature sensor, white Sensor with rotary setpoint dial, white Sensor with rotary setpoint dial and override button, white Room sensor adapter allows the use of other sensors and optional setpoint potentiometers (with wire leads or terminal blocks) to be used instead of STE-601x sensor models with modular jacks NOTE: Other STE-6000 series sensors are not fully compatible with the dedicated sensor port. However, various other models can be used with an HPO-9005 adapter or with the controller screw terminals. See the STE-6000 series data sheet for more information. For digital sensor information, see the STE-9000 series. NOTE: To order the STE-601x sensor with light almond color instead of white, drop the W on the end of the model number (e.g., STE-6010W is white and STE-6010 is light almond). Room Sensors, Digital (LCD Display) Miscellaneous Hardware HPO-9901 Controller replacement parts kit with terminal blocks (1 gray, 1 black, 2 green 3-terminal, 4 green 4-terminal, 2 green 5-terminal, 2 green 6-terminal) and DIN clips (2 small for router and 1 large for controllers) STE-9000 Series HPO-9001 KMC Conquest NetSensor digital room temperature sensors for viewing, configuring, and optional humidity, occupancy, and CO2 sensing NetSensor distribution module Transformers, 120 to 24 VAC SP-001 Screwdriver (KMC branded) with a hex end (for NetSensor cover screws) and a flat blade end (for controller terminals) 5 XEE-6111-050 XEE-6112-050 50 VA, single-hub 50 VA, dual-hub SAMPLE INSTALLATION Communication with Other Network Devices and Remote Monitoring SUPPORT Additional resources for installation, configuration, application, operation, programming, upgrading, and much more are available on the web at www.kmccontrols.com. Log-in to see all available files. Configuration via NFC-Enabled Smart Phone BAC-9001A on VAV Box (with air pressure sensor tubing attached) Up to 4 Sensors (to terminal blocks) STE-9xx1 NetSensor (to modular connector) Quick (temporary) Network Access Through Computer Data Port Up to 7 External Outputs (terminal blocks) TSP-8003 Actuator (with air pressure sensor tubing attached) on Dual Duct VAV Box (controlled by 2 of the BAC-9001's 7 maximum external outputs) For more information about installation and operation, see: · BAC-9000 Series VAV Controller Installation Guide · KMC Conquest Controller Application Guide · KMC Conquest Wiring: BAC-9000 Series Controllers (Video) © 2024 KMC Controls, Inc. Specifications and design are s6ubject to change without notice 925-035-02C