AUTOMATIC VOLTAGE REGULATOR
Model: AVR-REL-POWERUP500/1000-WL
Thank you for choosing a WELL product. Please read carefully the following instructions and keep them within reach.
Please read and save this manual!
Thank you for selecting this smart automatic voltage regulator (AVR). It provides you with a perfect protection for connected equipment.
This manual is a guide to install and use the AVR. It includes important safety instructions for operation and correct installation of the AVR. Should you have any problems with the AVR, please refer to this manual before calling customer service.
This symbol gives information regarding the points important for user's own health and safety, AVR operation and the safety of your data.
This symbol gives information, warnings, and other suggestions.
1. Important Safety Instructions
This AVR has been designed to provide all the necessary safety conditions needed to protect electronic office equipment including information systems. In case of any questions, refer to your authorized technical service representative.
- In order to avoid any damage to the equipment, it is advised to transport it in its own packing.
- In the event of sudden temperature changes such as from cold to the normal working temperature, mist can form inside the AVR. It is absolutely essential that the AVR be dry before switching it on. Due to this reason wait for at least 2 hours before operating it.
- Once it's dry, make sure you observe all the conditions in the environment section of the technical specifications table, before introducing it into the circuit.
Earth cable should be chosen concerning the current capacity. All units' earth connections, which are connected to AVR, should be done with this earth cable. Without earth connection or unproved earth connected units are dangerous for user health and have high risk of electronic circuit board faults. When installing the AVR to use cable with improper diameter can be dangerous for user's health and safety of the unit.
- Place all the cables in a proper place so that they are not stepped on or get caught into people's feet. Before connecting the AVR to the circuit makes sure you carefully read all the instructions and warnings in the "Installation" section of this manual.
- Don't drop any foreign materials (like clips, nails etc...) into the equipment.
- In emergencies (damage to the cabinet, front panel, or mains connections, splashing of liquid dropping of any foreign materials into the equipment) switch-off the AVR, pull out the plug and inform the authorized service center.
- Do not connect any loads to the AVR, which exceed its power range.
- When input distortion or resistance is too high, AVR may not work properly.
- Keep the packing for maintenance or moving.
- Wiring must be tight, to prevent falling off and oxidation.
The AVR can only be repaired by the authorized technical service personnel. Any attempt to open and to repair by the user on his own could prove to be dangerous.
Intended for installation in a controlled environment.
- The controlled environment should accord with the requirement of the specification.
- Do not install or operate your AVR in or near water.
- Do not place AVR on an unstable cart, stand or table.
- Do not place AVR under direct sunlight or close to heat emitting sources.
- Do not place AVR power cord in any area where it may get damaged by heavy objects.
Placing magnetic storage media on top of the AVR may result in data corruption.
Special precautions:
When the AVR input comes from a generator:
- Output power capacity must be higher than the AVR rating, or the AVR and generator may not work properly;
- Output frequency of generator must be in range of 45 to 65 Hz , and wave form must be sine wave, otherwise the AVR and generator may not work properly.
2. Specifications
Model No. | Power Capacity | Outlet | Cooling Mode | Circuit Protection |
AVR-REL-POWERUP500-WL | 500 VA / 300 W | 1 x schuko | Nature | Circuit Breaker, Output Fuse (4A, 250V) |
AVR-REL-POWERUP1000-WL | 1000 VA / 600 W | 1 x schuko | Nature | Circuit Breaker, Output Fuse (7A, 250V) |
AC Input Voltage | 150 V ~ 260 V |
Input Frequency | 45 Hz ~ 65 Hz |
AC Output Voltage | 230 V |
Output Frequency | Synchronized with mains |
Output Precision | +4%,-8% (without load) ± 3 V |
Distortion | <3% (compare to input wave form) |
Display | Single Digital Display |
Power Factor | 0.6 |
Efficiency | >0.95 |
Operating Temperature | -10°C ~ 40°C |
Operating Humidity | 0 ~ 90% (Non-condensing) |
Noise | ≤ 56 dB (full load, distance at 1 meter) |
Delay Time | 6 seconds |
Protection | Under Voltage, Over Voltage, Overheat, Short Circuit. |
Certification | CE (EMC+LVD) |
IP Class | IP20 |
Protection class | I |
Cable Length | 1.35 m |
Remarks: We reserve the right to change specifications or discontinue models without notice.
3. Before Installation
Each AVR was tested 100% before shipment, check if the AVR has been subjected to any damage after unpacking it according to the following steps:
A. Contents
Delivered pack includes:
AVR | 1 piece |
User's manual | 1 piece |
Warranty card | 1 piece |
B. Visual observation
- Check the name plate to verify the rated capacity is according to your purchase order.
- Make sure appearance of the AVR is not damaged. If you notice any damage, contact the transport firm and the authorized dealer.
Do not try to operate the AVR in this situation! Do not try to repair the AVR by yourself!
4. Introduction to the Regulator
Familiarize yourself with the various features and facilities by studying the two diagrams below to obtain maximum benefit from the regulator.
a. Front of the Regulator
500/1000VA model
The front panel features a digital display for input/output voltage, selection buttons for input/output voltage display, LED indicators, and a power switch.
b. Rear of the Regulator
500/1000VA model
The rear panel includes an output socket for connecting appliances, a circuit breaker, an AC input cable, and an output fuse.
5. Operation of the AVR
a. Connect the Electrical Appliances to Regulator
- Make sure all appliances are turned "OFF", and put power switch of AVR to "OFF" position.
- For model from 500VA to 1000VA, plug the AC mains cord of the appliances into the output socket of AVR, ensuring that the total starting power needed does not exceed the rated maximum output power of the AVR.
b. Connect Regulator to Electrical Mains
- For model from 500VA to 1000VA, just plug the AC mains cord to wall mains socket.
c. Switch on the regulator
Put the power switch to "ON" position. The yellow LED will illuminate and blink, indicating the delay time. The digital display will show the elapsing delay time (typically 6-180 seconds). After the delay, the yellow LED turns off and the green LED illuminates. The digital display will show the output voltage supplied to the connected appliances. Switch "ON" the appliances one by one.
In Case of Power Failure:
- Switch "OFF" the regulator and all the appliances.
- Repeat above steps when power is restored.
d. Display of Input Voltage and Output Voltage
- The output voltage will show in the display after switching it on.
- By pressing the "Input/Output Voltage Selective Button", the input voltage will be indicated in the display and flash.
- Press the "Input/Output Voltage Selective Button" again to show the output voltage.
e. LED Operation
- Green LED ON: Power ON, input and output voltage are normal, AVR is working.
- Yellow LED ON and flashing: Regulator is in delay status; output will be delayed.
- Red LED ON and flashing: Regulator is in protection status.
f. Delay Operation
This model is designed with a delay feature to protect appliances, especially those with compressors (like air-conditioners, refrigerators, motors, pumps, etc.), which should not be switched on immediately after being switched off. The delay time is typically set at 6 seconds. The delay time will show in the display after switching on the AVR. When the delay time has elapsed, the delay LED will switch "OFF" and the display will indicate the AC output voltage.
g. Integrated Automatic Protection Circuit (IAPC)
This model is equipped with a specially designed INTEGRATED AUTOMATIC PROTECTION CIRCUIT. This circuitry automatically cuts off the input voltage whenever the input voltage is above the input voltage range, rendering full and comprehensive protection to the regulator and connected appliances. When the input voltage returns to within the normal range, the IAPC will automatically switch the regulator back "ON" and restore power to all connected appliances.
h. Temperature Protection
This AVR is equipped with a unique TEMPERATURE PROTECTION CIRCUIT designed to protect the transformer, giving you longer and satisfactory use of the Regulator. If the internal temperature reaches the limit or above, the output will be cut "OFF" automatically, and the display will show "C". At the same time, the Red LED lights up. When the internal temperature returns to a normal range, output power will be restored. After the delay time, the display will indicate output voltage.
i. High Output Voltage Protection
This AVR has a built-in HIGH OUTPUT VOLTAGE PROTECTION CIRCUIT. This circuitry protects connected appliances whenever the output voltage is higher than the normal range. If the output voltage is over the normal range, the output power supply will cut "OFF" automatically and the display will show "H". At the same time, the Red LED lights up. Once the input city power returns to a normal range, the AVR will restore the output.
j. Low Output Voltage Protection
When the output voltage is below the normal range, the output will be cut "OFF" automatically and the display will show "L". At the same time, the Red LED lights up. Once the input city power returns to a normal range, the AVR will restore the output to the loads.
k. Short Circuit Protection
In case of a short circuit or overload, the POWER SWITCH (integrated with a resettable fuse function) or OUTPUT FUSE will trip off to cut off the input power supply. The OUTPUT FUSE should be replaced if it burns out. The Power Switch with the resettable fuse function must be reset to its initial position.
- Check if the AVR is overloaded; if so, please remove some loads.
- Check if the appliances are short-circuited; if so, please disconnect the appliances.
6. Placement
For safety and better performance and longer lifespan, please handle and place the AVR according to the following instructions:
a. Moving
- Cut off input; remove all wires connected to the AVR.
- Do not move the AVR upside down.
- Rough handling is prohibited.
b. Environmental
- Keep away from unstable base or sources of excessive vibration.
- Do not place the AVR under direct sunlight or excessive humidity.
- Keep away from fire, heat sources.
- Keep the AVR in a well-ventilated place. Leave at least a distance of 10 cm between the AVR and the walls in order to maintain adequate air-flow.
- Operating Temperature: -10°C ~ 40°C
- Operating Humidity: 0 ~ 90% (Non-condensing)
- Keep away from corrosive gas or fluid.
Install the AVR in a cool, dry, clean place - away from windows, dust, moisture and cold. To prevent fire or electrical shock, do not expose this unit to rain or water.
7. Maintenances
This AVR is basically maintenance-free! But regular maintenance can extend the lifespan of AVR by the following steps:
Regular inspection
- Shut down the AVR completely.
- Use a cotton cloth and detergent to clean the body and ventilation holes.
- Check all the terminals, replace the abnormal one with that of the same specification.
Extraordinary inspection
When malfunction occurs, or the AVR is abnormal, please measure and check the parameters, refer to the authorized dealer if needed. In thunder and lightning or rainy season, Extraordinary Inspection should be executed to prevent malfunction. Maintenance should not be operated when AVR is working.
8. Other
This AVR is designed and made by strict standards and quality control system for common use, but if applied to purposes that may cause any danger to human or other lives, include but not limited to the following cases, please refer to the company.
- Apply to traffic system;
- Apply to medical purpose;
- Apply to nuclear, power system;
- Apply to aviation and aerospace;
- Apply to all kinds of safety devices;
- Other special usages.
Waste electrical and electronic equipment are a special waste category; collection, storage, transport, treatment and recycling are important because they can avoid environmental pollution and are harmful to health. Submitting waste electrical and electronic equipment to special collection centers makes the waste to be recycled properly and protecting the environment. Do not forget! Each electric appliance that arrives at the landfill, the field, pollutes the environment!
SYMBOL FOR THE MARKING OF ELECTRICAL AND ELECTRONIC EQUIPMENT
Importer & distributor:
SC VITACOM ELECTRONICS SRL
CIF: RO 214527, 400495 Cluj-Napoca,
Str. Buna Ziua FN, Tel: 0264-438401*
sales@vitacom.ro, www.vitacom.ro