SCS Sentinel CodeAccess A - Keypad User Manual

This manual is an integral part of your product. These instructions are provided for your safety. Read this manual carefully before installing and keep it in a safe place for future reference. Select a suitable location. Make sure you can easily insert screws and wallplugs into the wall. Do not connect your electrical appliance until your equipment is totally installed and controlled. The installation, electric connections and settings must be made using best practices by a specialized and qualified person. The power supply must be installed in a dry place. Check the product is only used for its intended purpose.

Description

Content / Dimensions

The CodeAccess A keypad is a compact access control device. Its dimensions are:

The kit includes:

Wiring / Installing

Installing

Follow these steps for installation:

  1. Mount the backplate on the wall.
  2. Connect the wires according to the wiring diagram.
  3. Attach the keypad to the backplate.
  4. For a better seal, apply silicone to the top and the two sides of the keypad.

Wiring Diagram

To gate automation

Connections:

To strike/electric lock

Connections:

To reset the factory default

  1. Disconnect power from the unit.
  2. Press and hold the '#' key while powering the unit back up.
  3. On hearing two "BIP" sounds, release the '#' key. The system is now back to factory settings.

Note: Only installer data is restored; user data will not be affected.

Indications

Operation StatusRed LightGreen LightBuzzer
Stand byBlinking
Press keypadBIP
Operation successfulBrightBIP
Operation failedBIPBIPBIP
Enter into programming modeBright
In the programming modeBrightBrightBIP
Exit from the programming modeBlinkingBIP
Open the doorBrightBIP

Using

Fast programming

Programming a code

  1. Enter programming mode: Press '*' then the default master code (999999) then '#'.
  2. Add a code: Enter user number (1-100), then '#', then the 4-digit user code (except 1234), then '#'.
  3. Exit programming mode: Press '*' then '#'.

Programming a badge

  1. Enter programming mode: Press '*' then the default master code (999999) then '#'.
  2. Add a badge: Press '1' then '#'.
  3. Present the badge(s) to the keypad. Each programmed badge will automatically increment the user number.
  4. Exit programming mode: Press '*' then '#'.

Door opening

Detailed Programming Guide

User Settings

ActionProcedure
To enter the programming modeMaster code # (999999 is the default factory master code)
To exit from the programming mode*

Note: The master user must be logged in to perform the following programming.

Setting the working mode:

To add a user in either card or PIN mode (mode 32 #):

To add a card user:

To delete a card user:

To add a card and PIN user (mode 31 #):

Add the card as for a card user. Press '*' to exit programming mode. Then allocate the card a PIN as follows: * Read card 1234 # PIN # PIN #

To change a PIN in card and PIN mode:

To delete a Card and PIN user:

Simply delete the card.

To add and delete a card user in card mode (30 #):

The operation is the same as adding and deleting a card user in mode 32 #.

TO DELETE ALL USERS

2 0000 #. Note that this is a dangerous option, so use with care.

TO UNLOCK THE DOOR

Door settings

RELAY OUTPUT DELAY TIME

SettingCommand
To set door relay strike time* Master code # 4 0~99 # * (0-99 corresponds to the door relay time from 0 to 99 seconds)
To disable door open detection (Factory default)60#
To enable door open detection61#

Changing the master code

ActionCommand
Changing the master code0 New code #
New code #
The master code consists of 6 to 8 digits.

For security reasons, it is recommended to change the master code from the default.

Technical Features

Warranty

Warranty 2 years

The invoice will be required as proof of purchase date. Please keep it during the warranty period. Carefully keep the barcode and the proof of purchase, as this will be necessary to claim warranty.

Warnings

Before any maintenance, disconnect the appliance from the main power supply. Do not clean the product with solvents, abrasive or corrosive substances. Use only a soft cloth. Do not spray anything on the appliance.

Make sure that your appliance is properly maintained and regularly checked in order to detect any sign of wear. Do not use it if a repair or adjustment is needed. Always call on qualified personnel.

Do not throw batteries or out-of-order products with household waste (garbage). The dangerous substances they may contain can harm health or the environment. Ask your retailer to take back these products or use the selective collection of garbage proposed by your city.

Models: Codeaccess A Coding Keyboard, Codeaccess A, Coding Keyboard, Keyboard

File Info : application/pdf, 19 Pages, 1.77MB

PDF preview unavailable. Download the PDF instead.

clavier a codes memorisation 100 codes codeaccess a-manual-25 fr.1661956308749

References

Adobe InDesign 16.4 (Windows) Adobe PDF Library 16.0

Related Documents

Preview SCS Sentinel CodeAccess A Keypad Installation and User Manual
Comprehensive guide for the SCS Sentinel CodeAccess A keypad, covering installation, wiring, programming, technical specifications, and safety warnings. Learn how to program codes, badges, and manage user access.
Preview SCS Sentinel : Offre Clavier de Codage Gratuit avec Motorisation OpenGate
Découvrez l'offre promotionnelle SCS Sentinel : recevez un clavier de codage CodeAccess A gratuit pour tout achat d'une motorisation de portail OpenGate. Détails sur l'éligibilité, la procédure et les conditions.
Preview SCS Sentinel CodeAccess RFID Keypad Manual
Comprehensive installation and user manual for the SCS Sentinel CodeAccess RFID keypad, covering setup, programming, features, and safety guidelines.
Preview SCS Sentinel CodeVisio Wi-Fi Video Intercom System Manual
Comprehensive guide for the SCS Sentinel CodeVisio Wi-Fi video intercom system (PVF0054). Covers installation, wiring, app configuration (iSCS Sentinel), usage, technical features, and safety precautions.
Preview SCS Sentinel AudioKit 3208D Wired Intercom System - Installation and User Manual
Comprehensive guide for the SCS Sentinel AudioKit 3208D wired interphone system, covering safety instructions, product description, wiring and installation procedures, technical specifications, assistance, warranty, and important warnings.
Preview SCS Sentinel WifiGate Connected Receiver Module for Motorization - User Manual
Comprehensive user and installation manual for the SCS Sentinel WifiGate connected receiver module. Learn how to install, configure the iSCS Sentinel app, use features like remote control and voice commands, troubleshoot issues, and understand product specifications and warranty.
Preview SCS Sentinel CodeAccess RFID Clavier de Codage avec Badges - Manuel d'Utilisation et d'Installation
Manuel d'utilisation et d'installation pour le clavier SCS Sentinel CodeAccess RFID, détaillant les fonctionnalités, le câblage, la programmation et les spécifications techniques.
Preview SCS Sentinel OpenGate 2 & VisioDoor 7+RFID: Installation and User Manual
Comprehensive guide for SCS Sentinel's OpenGate 2 articulated arm gate automation system and VisioDoor 7+RFID video intercom system, covering installation, setup, features, maintenance, and troubleshooting.