Mitsubishi Electric Ecodan R290 Monobloc Air Source Heat Pump
Model: PUZ-WZ60VAA(-BS)
Product Information
The Mitsubishi Electric Ecodan R290 Monobloc Air Source Heat Pump offers efficient and renewable heating and hot water solutions. It is designed for high performance and environmental consciousness.
Key Features:
- A+++ heating efficiency
- Ultra quiet noise levels
- MELCloud enabled for remote control and monitoring
- High water temperature of up to 75°C
- Fully electric source of heating and hot water
Key Benefits:
- Minimised energy consumption
- Flexible product placement
- Remote control, monitoring, maintenance and technical support
- Ideal for energy storage
- Zero carbon ready
Technical Specifications
Outdoor Unit: PUZ-WZ60VAA(-BS)
Specification | Details |
---|---|
HEAT PUMP SPACE HEATER - 55°C ErP Rating | A++ |
ηs (55°C) | 139% |
SCOP (MCS) (55°C) | 3.56 |
HEAT PUMP SPACE HEATER - 35°C ErP Rating | A+++ |
ηs (35°C) | 179% |
SCOP (MCS) (35°C) | 4.55 |
HEAT PUMP COMBINATION HEATER - Large Profile ErP Rating | A+ |
ηwh | 143% |
HEATING 2 (A-7/W35) Capacity (kW) | 6.2 |
Power Input (kW) | 2.51 |
COP | 2.47 |
OPERATING AMBIENT TEMPERATURE (°C DB) | -25~+46 |
MAXIMUM WATER OUTLET TEMPERATURE (°C) | 75 |
SOUND DATA Pressure Level at 1m (dBA) | 40 |
Power Level (dBA) | 56 |
WATER DATA Pipework Size (mm) | 22 |
Flow Rate (l/min) | 17 |
Flow Temperature (°C) | 65 |
Water Pressure Drop (kPa) | 26 |
DIMENSIONS (mm) Width | 1020 |
Depth | 1050 |
Height | 480 |
WEIGHT (kg) | 89 |
ELECTRICAL DATA Electrical Supply | 220-240v 50Hz |
Phase | Single |
Nominal Running Current [MAX] (A) | 13 |
Fuse Rating - MCB Sizes (A) | 16 |
REFRIGERANT CHARGE (kg) / CO₂ EQUIVALENT (t) | R290 (GWP 3) / 0.6 / 0.0018 |
Flow Temperature Curve
A graph shows the relationship between ambient temperature and flow temperature. The Y-axis represents Flow Temperature (°C) ranging from 45 to 80. The X-axis represents Ambient Temperature (°C) ranging from -30 to 35. The curve starts at approximately 75°C flow temperature at -25°C ambient temperature and decreases as the ambient temperature increases, reaching approximately 55°C flow temperature at 35°C ambient temperature.
Dimensions (mm)
Diagrams show the front, upper, and side views of the outdoor unit with key dimensions indicated:
- Front View: Shows width (1020mm), depth (1050mm), and height (480mm). Specific internal dimensions and component placements are also illustrated.
- Upper View: Shows the unit's width and depth, with callouts for air intake and discharge.
- Side View: Shows the unit's depth and height, with callouts for air intake and discharge.
Contact and Further Information
For more information, please contact Mitsubishi Electric:
- Telephone: 01707 282880
- Email: heating@meuk.mee.com
- Website: ecodan.co.uk
Follow Mitsubishi Electric Heating UK on social media: [LinkedIn icon] [Facebook icon] [Instagram icon] [YouTube icon] [Blog link: thehub.mitsubishielectric.co.uk]
Company Information:
United Kingdom: Mitsubishi Electric Europe, Living Environment Systems Division, Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England. Telephone: 01707 282880 Fax: 01707 278881
Ireland: Mitsubishi Electric Europe, Westgate Business Park, Ballymount, Dublin 24, Ireland. Telephone: (01) 419 8800 Fax: (01) 419 8890 International code: (003531)
Country of origin: United Kingdom - Japan - Thailand - Malaysia.
Effective as of October 2023
Certifications: CE, UKCA
Learn more about green initiatives at greengateway.mitsubishielectric.co.uk
Notes
- *1 Combination with EHPT20X-MEHEW Cylinder
- *2 Under normal heating conditions at outdoor temp: -7°CDB/-8°CWB, outlet water temp 35°C, inlet water temp 30°C.
- *3 Under normal heating conditions at outdoor temp: 7°CDB / 6°CWB, outlet water temp 55°C, inlet water temp 47°C as tested to BS EN14511.
- *4 Sound power level tested to BS EN12102.
- *5 Under nominal heating conditions at outdoor temp: 7°C, outlet water temp: 35°C.
- *6 MCB Sizes BS EN60898-2 & BS EN60947-2.
- ηs is the seasonal space heating energy efficiency (SSHEE)
- ηwh is the water heating energy efficiency
- Refer to 'Installation Manual' and 'Instruction Book' for further 'Technical Information'.
- The fuse rating is for guidance only and please refer to the relevant databook for detailed specification.
- It is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions.
- Mitsubishi Electric's air conditioning equipment and heat pump systems contain a fluorinated greenhouse gas, R410A (GWP:2088), R32 (GWP:675), R407C (GWP:1774), R134a (GWP:1430), R513A (GWP:631), R454B (GWP:466), R1234ze (GWP:7) or R1234yf (GWP:4). *These GWP values are based on Regulation (EU) No 517/2014 from IPCC 4th edition. In case of Regulation (EU) No.626/2011 from IPCC 3rd edition, these are as follows. R410A (GWP:1975), R32 (GWP:550), R407C (GWP:1650) or R134a (GWP:1300).
Related Documents
![]() |
Mitsubishi Electric Air to Water Heat Pump Parts Catalog R32 Comprehensive parts catalog for Mitsubishi Electric R32 split-type air to water heat pumps, including structural and electrical components, with part numbers and quantities for various models. |
![]() |
Mitsubishi Electric Ecodan E-Generation Heat Pumps: Efficient and Smart Heating Discover the Mitsubishi Electric Ecodan E-Generation heat pump system, offering intelligent, efficient, and eco-friendly heating and hot water solutions for families. Learn about its features, benefits, and technical specifications. |
![]() |
Mitsubishi Electric Ecodan & Zubadan Split Heat Pumps Technical Specifications Comprehensive technical specifications for Mitsubishi Electric Ecodan and Zubadan Split heat pump systems, covering indoor and outdoor unit details, key technologies, and performance data for heating, cooling, and domestic hot water. |
![]() |
Mitsubishi Electric Heat Pump Product Information and Technical Data Comprehensive technical specifications and energy efficiency data for Mitsubishi Electric heat pump systems, including space heaters and combination heaters, compliant with EU regulations. |
![]() |
Mitsubishi Electric Ecodan Planning Handbook - E-Generation Comprehensive planning and design guide for Mitsubishi Electric Ecodan air-to-water heat pump systems, covering technical specifications, installation, operation, and system integration for new builds and renovations. |
![]() |
Mitsubishi Electric Ecodan Monoblock Heat Pumps with R290: Technical Overview and Benefits Explore Mitsubishi Electric's Ecodan Monoblock heat pumps featuring natural R290 refrigerant. Discover their efficiency, performance at low temperatures, cascade capabilities, and suitability for modernizing existing buildings. Includes technical specifications and support information. |
![]() |
Mitsubishi Electric Ecodan Monoblock Heat Pumps with R290 Discover Mitsubishi Electric's Ecodan Monoblock heat pumps featuring natural R290 refrigerant. This brochure details their efficiency, performance in various temperatures, and suitability for both new builds and renovations, including cascade solutions for larger properties. |
![]() |
Mitsubishi P-Series PKA-A36KA7 & PUZ-A36NKA7 Heat Pump System Submittal Data Detailed submittal data, specifications, features, and dimensions for the Mitsubishi Electric P-Series PKA-A36KA7 indoor unit and PUZ-A36NKA7/(-BS) outdoor unit, a 36,000 BTU/h wall-mounted heat pump system. |