ANENG A3005 Digital Multimeter Pen User Manual

This document provides instructions and specifications for the ANENG A3005 digital multimeter pen.

Basic Introduction

The ANENG A3005 is a 3 3/4 digit True RMS auto-scanning digital multimeter pen. It features automatic function selection for voltage and resistance measurements, eliminating the need to manually turn a dial. It offers stable performance, high accuracy, high reliability, clear readings, and overload protection. Powered by a single AAA 1.5V battery, it boasts a large LCD display with a clear backlight for easy viewing. This meter automatically identifies DC voltage, AC voltage, resistance, and continuity, in addition to manual selection for electric field induction, diode, and fire line discrimination. It is designed as an ideal tool for electronics hobbyists, electricians, and general household use.

Safety Requirements

This series of digital meters is designed and produced according to IEC1010 safety standards for electronic measuring instruments and portable current meters. It strictly conforms to double insulation, DC 600V CAT III, and pollution level 2 standards.

Precautions

Product Features

Operation Illustration

Instrument Diagram

The pen-type multimeter features the following components:

  • COM Terminal (for test pen)
  • Power Switch Button
  • Data Hold and Backlight Button
  • NCV/LIVE/Flashlight Button
  • Screen (Display)
  • Indicator Light
  • Flashlight
  • Probe Tip and Positive Terminal
Diagram showing the physical layout of the multimeter pen and its controls.

DC Voltage Test

  1. Press and hold the " (0) " button for more than 2 seconds to turn on the instrument; it will display "Huto".
  2. Insert the black test pen into the COM jack.
  3. Connect the instrument's probe tip and the black test pen to the power source or load to be tested. The polarity of the probe will be displayed on the screen.
  4. Read the measurement result on the monitor. If the " ~ " symbol is displayed to the right of the monitor, DC voltage is being measured.

Do not input a voltage higher than 600 V. Inputting a voltage higher than this may display a higher voltage and risk damage to the meter's internal circuitry.

Do not touch the probe tip or the metallic part of the test pen when measuring high voltage to avoid electric shock.

AC Voltage Test

  1. Press and hold the " (0) " button for more than 2 seconds to turn on the instrument; it will display "ut".
  2. Insert the black test pen into the COM jack.
  3. Connect the instrument's probe tip and the black test pen to the power source or load to be tested. The polarity of the probe will be displayed on the screen.
  4. Read the measurement result on the monitor. If the " @9 " symbol is displayed to the right of the monitor, AC voltage is being measured.

Do not input a voltage higher than 600 V. Inputting a voltage higher than this may display a higher voltage and risk damage to the meter's internal circuitry.

Do not touch the probe tip or the metallic part of the test pen when measuring high voltage to avoid electric shock.

Resistance Test

  1. Press and hold the " (0) " button for more than 2 seconds to turn on the instrument; it will display "ut".
  2. Insert the black test pen into the COM jack.
  3. Connect the instrument's probe tip and the black test pen to the power source or load to be tested. The polarity of the probe will be displayed on the screen.
  4. Read the measurement result on the monitor. If the " ~ " symbol is displayed to the right of the monitor, resistance is being measured.

If the measured resistance exceeds the maximum range value, the screen will display "OL".

When checking resistance in a live circuit, all power to the line under test must be turned off, and all capacitors must be completely discharged.

Continuity Test (Circuit On/Off Test)

  1. Press the " (o) " button for more than 2 seconds to start the system.
  2. Insert the black test pen into the COM jack.
  3. Connect the instrument's probe tip and the black test pen to two points in the circuit. If the resistance between the two points is less than approximately 50 Ω, the built-in buzzer will sound, indicating that the two points are connected. An "m" symbol will appear on the right side.

When the circuit is on, an "m" symbol will appear on the right side.

Diode Test

  1. Press " () " for more than 2 seconds. The instrument will display "Hut".
  2. Briefly press this meter's button to test the diode. "OL v" will appear.
  3. Insert the black test pen into the COM jack.
  4. Connect the instrument's probe tip to the positive electrode of the diode and the black test pen to the negative electrode. The instrument will display the forward voltage drop of the diode (unit: V). "OL" is displayed when the diode is reversed.

NCV (Non-Contact Voltage) Test

  1. Press and hold the " Co " button for more than 2 seconds to turn on the instrument; it will display "Hut".
  2. Insert the black test pen into the COM jack.
  3. Press the button to select the NCV mode. On the display screen, "EF" will be shown.
  4. Place the instrument's probe tip approximately 8 ~ 15 mm from the object to be measured for induction detection. The simulated induced AC voltage is indicated by the buzzer rhythms and the red indicator light, distinguishing the intensity of the induced electric field.
  5. If the critical voltage is 100 V, "EF" is displayed; if the critical voltage is < 100V, "-" is displayed in the cross-section. There are four sections "- - - -" indicating different voltage levels.

When changing NCV measurement mode, please disconnect the black test pen to avoid electric shock.

Live Wire Detection

  1. Press and hold the " "" " button for more than 2 seconds to turn on the instrument; it will display "ut".
  2. Press the " @ " button to select LIVE measurement. "LIVE" will be displayed on the right side of the screen.
  3. When the instrument's probe tip is connected to the live wire, the buzzer will emit a ticking sound, and the red LED indicator will light up, and the LCD screen will display "--H". If the pen is connected to the neutral wire, the buzzer will not sound, and the LCD screen will display "LIVE".

Do not touch the metallic part of the test pen during measurement to avoid the risk of electric shock.

Data Hold

During measurement, briefly press the " TROU PRISE J " button to activate or deactivate data hold.

Backlight

Press and hold the " bouton > 2 secondes " button to turn the backlight on or off.

Flashlight

Press and hold the " 't -J" bouton > 2 secondes " button to turn the flashlight on or off.

Auto Power Off

If there is no operation for 15 minutes, the meter will automatically shut down to conserve battery power.

Specifications

DC Voltage

RangePrecisionResolution
4V±(1.0%+5)1mV
40V
400V
600V

Overload Protection: Maximum input 600 V.

AC Voltage

RangePrecisionResolution
4V±(1.2%+5)1mV
40V
400V
600V

Overload Protection: Maximum input 250 V.

Frequency Range: 40 Hz - 1 000 Hz

Resistance

RangePrecisionResolution
4 kΩ±(1.2%+3)
40 kΩ
400 kΩ
4 MΩ
40 MΩ±(2.0%+5)10Ω

Overload Protection: Maximum input 250 V.

Continuity

FunctionCondition
Continuity (Buzzer)When resistance is less than approx. 50 Ω, the buzzer sounds and the red indicator light turns on.

Overload Protection: Maximum input 250 V.

General Characteristics

Manual Instructions

Warning: Before opening the back cover of the meter, ensure that the test pen is not connected to the tested circuit. Before using the meter, ensure that the back cover is tightly secured. If "'" is displayed, it indicates that the battery needs to be replaced. Follow these steps for replacement:

  1. Disconnect the test pen from the test circuit and remove it from the input jack.
  2. Unscrew the battery cover with a screwdriver and remove it.
  3. Remove the old battery and replace it with a new one.
  4. Replace the battery cover and tighten the screws.

PDF preview unavailable. Download the PDF instead.

Sb94e61f9e86742aa9fac6600114d8b45V jsPDF 2.5.1

Related Documents

Preview ANENG M127/M128 Multimeter User Manual
Comprehensive user manual for the ANENG M127 and M128 portable smart multimeters, detailing features, functions, and operating instructions.
Preview ANENG AN870 Digital Multimeter User Manual
User manual for the ANENG AN870 digital multimeter, detailing its features, specifications, safety information, operating instructions, maintenance, and troubleshooting.
Preview ANENG 621A Intelligent Digital Multimeter User Manual
User manual for the ANENG 621A intelligent digital multimeter, detailing its features, technical specifications, operating instructions, and maintenance.
Preview ANENG M107 Mini Multimeter: Features, Specifications, and Usage Guide
Discover the ANENG M107, a compact and intelligent smart digital multimeter. This guide covers its automatic measurement capabilities, AC/DC voltage and current testing, resistance measurement, NCV detection, flashlight, innovative storage, and detailed functional parameters.
Preview ANENG MT87 Digital Clamp-on Multimeter: User Manual & Specifications
Explore the ANENG MT87 Digital Clamp-on Multimeter. This comprehensive manual covers safety, features, specifications, and operation for accurate electrical measurements.
Preview ANENG AN113E Digital Multimeter User Manual - Features, Specifications, and Operation
Comprehensive user manual for the ANENG AN113E digital multimeter. Learn about its features, safety information, specifications, measurement instructions for voltage, current, resistance, and more.
Preview ANENG ST181 Mini Digital Clamp-On Multimeter Operation Manual
Operation manual for the ANENG ST181 Mini Digital Clamp-On Multimeter, covering safety, panel description, specifications, and detailed instructions for various electrical measurements including voltage, current, resistance, capacitance, frequency, and temperature.
Preview ANENG A3002 High Precision Pen Multimeter - Features and Specifications
Explore the ANENG A3002, a portable digital pen multimeter offering high precision, non-contact voltage detection, and a bright HD screen. Learn about its features, measurement capabilities, and after-sales support.