Diagrams:
A diagram shows a Hygger HG105 DC frequency water pump, a submersible unit with a ribbed body and a base designed for water intake. A separate diagram shows the Hygger controller unit with a digital LCD display, featuring buttons labeled 'MODE', '+', and '-' for operation.
WARNINGS:
- Please use the adapter and related accessories.
- Do not put the pump in flammable, explosive, or corrosive liquid.
- Do not use the pump in water with a temperature above 35℃ (95℉).
- Maximum water depth is 1.5M (4.9ft).
- Do not immerse the plug in water or other liquid.
- Do not allow children or inexperienced individuals to operate the product alone without safety precautions.
1. PRODUCT FEATURES:
- Visual LCD display with 4 water circulation modes, power feeder function, and DC safety voltage usage.
- Bottom suction water intake, suitable for low water level operation.
- Sine wave technology, ultra-quiet operation, with IC electronic detection.
- No water dry running and locked rotor protection.
- Mini size with an elegant appearance.
- Suitable for use in seawater and freshwater.
PRODUCT SPECIFICATION:
Model | HG105-1500 | HG105-2500 | HG105-3500 |
---|---|---|---|
Voltage | DC 24V | ||
Power | 20W | 30W | 35W |
Flow Rate | 396GPH (1500L) | 660GPH (2500L) | 925GPH (3500L) |
Head Max | 6.6ft (2m) | 9.8ft (3m) | 11.5ft (3.5m) |
US standard outlet nozzle | 3/4" | 3/4" | 1" |
5/8" | Straight nozzle:3/4" | Straight nozzle:1" | |
Screw cap :G 3/4" | Screw cap :G 1-1/8" | Screw cap :G 1-3/8" | |
EU/UK standard outlet nozzle | 19mm | 29mm | 25mm |
15.9mm | 25mm | 31.5mm | |
26.9mm | outer:31mm inner:25mm | outer:38mm inner:32mm | |
37mm | 44.7mm |
3. OPERATING INSTRUCTION:
CONTROLLER FEATURE:
- Pause button: Pause for 10 minutes to feed fish.
- '+/-' button: Adjust water flow from F30-F100.
- Power button: Turn on/off power.
- Mode: Choose mode from M1/M2/M3/M4
- M1: Constant Wave Mode
- M2: Classic Wave
- M3: Sine Wave Mode
- M4: Random Wave Mode
- Attention: Only M1 mode displays power level on the screen.
MAINTENANCE AND CAUTION:
When using the pump, please pay attention to its position. Connect the pump supply after installation. If the pump fails to pump out water the first time, this may be caused by air in the pump body. Try unplugging and replugging to vent the air. To ensure safety, install an earth leakage switch with a leakage current of less than 30mA when using outdoors (the earth leakage switch shall be installed by the user).
- Always disconnect the pump from the power supply before cleaning, maintenance, and handling.
- Try to avoid the pump running dry.
- Do not lift the pump by just holding the power cord, as cable connections inside the pump may become disconnected.
- Do not use the pump in heated liquids.
- The pump cannot be used in swimming pools.
Protection Functions
This product has multiple protection functions. When entering the protection state, unplug the power supply and then plug it back in to restore the pump to normal operation.
4. TROUBLE SHOOTING:
Error code | Fault | Solution |
---|---|---|
Er01 | Controller over current | Abnormality working current; check if the pump is short-circuited or the controller is damaged. |
Er02 | Controller over temperature | Check that the controller is not exposed to sunlight or high temperature environment. |
Er03 | The pump is idling | The pump is idling; check if the pump is dry heating. The pump must be filled with water before running. |
Er04 | The pump is blocked | Currently the impeller is out of operation. Clean the pump and impeller to ensure the impeller is clean and working properly. |
Er05 | Controller over voltage / Controller under voltage | Check the input supply voltage. |
5. DISPOSAL
Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. This product must be disposed of at an authorized place for the recycling of electrical and electronic appliances, rather than being disposed of with domestic waste. Collecting and recycling waste is a way of saving natural resources. Please consult with your local seller to ensure the product is disposed of in an environmentally friendly way.
6. PACKING LIST
Model | HG105-1500 | HG105-2500 | HG105-3500 |
---|---|---|---|
Water pump | ✔ | ✔ | ✔ |
DC adapter | ✔ | ✔ | ✔ |
LCD controller with holder | ✔ | ✔ | ✔ |
User manual | ✔ | ✔ | ✔ |