VEVOR Towel Warmer Racks

Technical Support and E-Warranty Certificate: www.vevor.com/support

USER MANUAL

Thank you for purchasing VEVOR Towel Warmer Racks. This manual provides essential information for safe operation and installation.

Model Numbers: CSS11-M-H-500*500, CSS11-M-U-500*500, CSS11-M-H-610*500, CSS11-M-U-610*500, CSS11-M-H-800*500, CSS11-M-H-1000*500, CSS11-M-U-1000*500, CSS11-O-H-500*500, CSS11-O-U-500*500, CSS11-O-H-610*500, CSS11-O-U-610*500, CSS11-O-H-800*500, CSS11-O-H-1000*500, CSS11-O-U-1000*500.

VEVOR is committed to providing tools at competitive prices. The terms "Save Half" or "Half Price" represent an estimate of potential savings compared to major brands and may not apply to all product categories.

Safety Instructions

[Information symbol] Warning: To reduce the risk of injury, user must read instructions manual carefully.

[WEEE symbol: crossed-out wheelie bin] This product is subject to European Directive 2012/19/EC and requires separate refuse collection in the European Union. Products marked with this symbol must be taken to a collection point for recycling electrical and electronic devices.

[Indoor use symbol: house] Indoor use only.

Please obey basic safety instructions when using electrically heated towel racks. READ THESE INSTRUCTIONS CAREFULLY and keep them handy for future reference.

  • This appliance is used for warming and drying towels and becomes hot to touch. Young children or infirm persons should be supervised and prevented from touching the appliance while it is working.
  • The rack gets hotter during warming periods due to ambient temperature rise. DO NOT TOUCH HOT SURFACES DIRECTLY.
  • The insulation effect of towels can slightly increase the operating temperature.
  • When installing, ensure switches and control buttons cannot be touched by a person in a bath or shower.
  • This appliance is ONLY for warming and drying towels; DO NOT use it for any other purpose.
  • To avoid danger, this product MUST NOT be used to hold items with oil, petroleum-based products, or dry cleaning fluids.
  • Ensure the voltage matches the rated value in this manual.
  • For safety, electrical work must be done by an authorized person according to correct Wiring Rules and Regulations.
  • DO NOT immerse in any liquid.
  • DO NOT allow the power cord to contact hot surfaces while working.
  • If the product malfunctions or is damaged, it must be fixed or replaced by the manufacturer, its service agent, or qualified persons.
  • This appliance is intended for HOUSEHOLD USE ONLY and not for commercial purposes.
  • Do not operate with a damaged plug or cord, after a malfunction, or after being dropped or damaged.
  • Children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities or lack of experience can use this appliance if given supervision or instruction on safe use and understanding the hazards. Children shall not play with the appliance. Cleaning and user maintenance must not be done by children without supervision.
  • If the supply cord is damaged, it must be replaced by a special cord or assembly from the manufacturer or its service agent.
  • WARNING: The bottom of this product MUST be installed at least 600 mm above the floor to avoid the risk of harm to young children.

SAVE THESE INSTRUCTIONS

PRODUCT PARAMETER

NOTE: ① The screen displays 50-70℃, with an adjustment range of 5 stops (temperature detection inside the round tube). ② The maximum surface temperature of the product is 60-65℃.

ModelPower (W)VoltageMaximum Loading WeightProduct ColorProduct Size (mm)
CSS11-M-H-500*500106AC120V 60Hz15kgBlack500*500*102
CSS11-M-U-500*500Silver
CSS11-O-H-500*500106AC 230V 50/60HzBlack500*500*102
CSS11-O-U-500*500Silver
CSS11-M-H-610*500156AC120V 60Hz15kgBlack610*500*102
CSS11-M-U-610*500Silver
CSS11-O-H-610*500145AC 230V 50/60HzBlack610*500*102
CSS11-O-U-610*500Silver
CSS11-M-H-800*500212AC120V 60Hz15kgBlack800*500*102
CSS11-O-H-800*500195AC 230V 50/60HzSilver
CSS11-M-H-1000*500262AC120V 60Hz15kgBlack1000*500*102
CSS11-M-U-1000*500Silver
CSS11-O-H-1000*500260AC 230V 50/60HzBlack1000*500*102
CSS11-O-U-1000*500Silver

INSTALLATION & ILLUSTRATION

Thank you for purchasing our Heated Towel Racks. This towel rack offers a flexible way to connect with the power supply. The electrical connection can be made through either the lower left or right legs, either directly wired through the wall or via the cord and plug supplied.

Notes:

  • Check product and line condition before installation.
  • Install the towel rack on a reliable and firm wall.
  • The towel rack should not be used for riding or pulling, and the maximum load should not exceed 15 kg.
  • Keep hands dry when plugging and unplugging. Keep the power off when installing waterproof plugs.
  • The heated towel rack must be installed by a professional service agent or qualified person. Read safety information before installing.
  • Ensure adequate space for the heated towel rack and avoid direct contact with other objects.

TOOLS REQUIRED

  • [Image: Electric drill] Drill
  • [Image: Pencil] Pencil
  • [Image: Phillips screwdriver] Phillips Screwdriver

PARTS LIST

Serial NumberNameQTYNotes
1Towel Rack1 pcs
2Wall Spacer (A)2 pcs[Image: Two cylindrical metal spacers with mounting holes]
3Wall Spacer (B)1 pcs[Image: Cylindrical metal spacer with a wider flange]
4Wall Spacer (C)1 pcs[Image: Cylindrical metal spacer with a slot]
5Mounting Base4 pcs[Image: Circular metal mounting plate]
6Self-Tapping Screw4 pcs[Image: Screw with a sharp point]
7Plastic Expender4 pcs[Image: White plastic wall anchor]
8Set Screw (M5*8)4 pcs[Image: Small screw with a hex socket head]
9Screw (M8*10)2 pcs[Image: Larger screw with a hex socket head]
10Cross Screw (M5*16)2 pcs[Image: Screw with a cross-head slot]
8Power Cord1 pcs[Image: Power cord with connector]
9Spanner (large)1 pcs[Image: L-shaped hex wrench]
10Spanner (small)1 pcs[Image: Smaller L-shaped hex wrench]

INSTALLATION STEPS (TOWEL RACK MAIN PARTS INSTALLATION)

STEP 1

Install the upper two ports:

Attach the Towel Rack to the Wall Spacer (A) using Screw (M8*10) and a Spanner (large). Note: Confirm the power cable outlet position (left or right side) before proceeding.

STEP 2

Attach the Power Plug to the Towel Rack using Wall Spacer (B) and Cross Screw (M5*16). Note: Verify the Power Plug cover is installed or tightened before installing Wall Spacer(B).

STEP 3

Attach the Power Cord to the Towel Rack using Wall Spacer (C) and Cross Screw (M5*16). Note: Ensure the Power Cord is installed and tightened before installing Wall Spacer(C).

STEP 4

Marking and Drilling:

  1. Use a pencil to draw the position of the 4 Wall Spacers on the wall.
  2. Draw 4 points on the wall and use an electric drill to punch holes in the corresponding places.

INSTALLATION STEPS (EXPOSED POWER CORD CONNECTION)

STEP 5

  1. Insert Plastic Expender into the wall holes.
  2. Take out the Self-Tapping Screw, pass it through the Mounting Base center hole, and tighten to fix the base to the wall.

STEP 6

  1. Remove the Towel Rack and place it fully into the Mounting Base.
  2. Use the Set Screw (M5*8) and a Spanner (small) to fix the Towel Rack to the Mounting Base.
  3. Push the Towel Rack to ensure stable and correct installation. Connect the Power Cord to the male connector.

Tip: If the Towel Rack cannot be set into the Mounting Base, loosen the Self-Tapping Screw and adjust the matching position.

INSTALLATION STEPS (CONCEALED POWER CORD CONNECTION)

STEP 7

  1. Determine the position of the Cable Hole based on the Power Cable's position on the Towel Rack.
  2. Insert Plastic Expanders into the wall holes, except for the Cable Hole.
  3. In addition to the Cable Hole, take out the Self-Tapping Screw, pass it through the Mounting Base center hole, and tighten to fix.

STEP 8

  1. Reserve the required power cable length and cut any excess.
  2. Thread the power cord through the remaining Mounting Base, assemble the Mounting Base onto the towel rack, and fix it using the Set Screw (M5*8).
  3. Remove the Towel Rack and place it fully into the Mounting Base.
  4. Take the Set Screw (M5*8) and fix the Towel Rack.

Tip: If the Towel Rack cannot be set into the Mounting Base, loosen the Self-Tapping Screw and adjust the matching position.

SCREEN INSTRUCTIONS

Screen Details

  • Temperature Adjustment: 50~70℃.
  • Timer Adjustment: 1H~8H.

Button Description

  • [Power Button] Switch Button
  • [Temperature Adjustment Button] Temperature Adjustment Button
  • [Timer Button] Timer Button

INDICATOR ON SCREEN FOR DIFFERENT WORKING MODES

  • Power Off: Switch button semi-bright. [Image: Control panel showing Power Off state with a semi-bright power button.] (See Figure 1)
  • Power On: Temperature can be adjusted between 50-70℃. [Image: Control panel showing Power On state with temperature display (50°C) and icons for timer and temperature.] (See Figure 2)
  • Time can be adjusted between 1H-8H or set to Normally Open. [Image: Control panel showing timer setting (e.g., 50°C, timer icon, temperature icon).] (See Figure 3) [Image: Control panel showing 'Normally Open' state.] (See Figure 4)
  • Temperature Heating Mode: White dots are observed to flicker. [Image: Control panel showing Temperature Heating Mode with flickering white dots.] (See Figure 5)

OPERATION INSTRUCTIONS

  1. To Switch On: When the Towel Warmer Racks is off, short press the [Power Button] to start the device.
  2. Adjust the Heating Temperature: Short press the [Temperature Adjustment Button] to adjust the heating temperature. The temperature will adjust by 5℃ for each press. After 3 seconds of setting, the icon stops blinking.
  3. Adjust the Timer: Short press the [Timer Button] to change the timer to 1 hour → 8 hours, or select Normally Open. The time adjusts by 1H for each press. After 3 seconds of setting, the icon stops blinking.
  4. To Switch OFF: Short press the [Power Button] to turn off the device.

TEMPERATURE COMPENSATION

Press and hold the [Temperature Adjustment Button] for 5 seconds in the off state to enter the temperature compensation setting. There are 9 options: "0℃", "+2℃", "+4℃", "+6℃", "+8℃", "-8℃", "-6℃", "-4℃", "-2℃". Press the [Temperature Adjustment Button] to select. (The default setting is 0℃).

As shown in Figure 6. Press the [Power Button] to confirm and exit the temperature compensation setting. [Image: Control panel showing temperature compensation setting options.] (See Figure 6)

FACTORY DATA RESET

In the startup state, press the [Power Button] for 5 seconds to restore factory settings. The icon will be fully displayed for 3 seconds to enter the shutdown state. A short press of the [Power Button] starts the device. The constant temperature mode is restored to 50℃, the timing mode to 2 hours, and temperature compensation to 0.

ERROR DISPLAY

When the temperature probe is abnormal, the display shows "Er". [Image: Control panel showing an error display 'Er'.] (See Figure 7)

CLEANING

The Heated Towel Rack is best wiped down from time to time with a damp cloth. DO NOT USE ANY ABRASIVE OR CORROSIVE CLEANERS.

PDF preview unavailable. Download the PDF instead.

毛巾加热架(共14个SKU)-说明书(生产版) 1732683544126 WPS 文字

Related Documents

Preview VEVOR Heated Towel Racks User Manual - Installation and Operation Guide
Comprehensive user manual for VEVOR Heated Towel Racks, covering safety, installation, operation, and product specifications. Find model details and support information.
Preview VEVOR Portable Power Electric Hoist User Manual - Models 500-A1, 500-B1, 500-C1
User manual for VEVOR Portable Power Electric Hoist (Models 500-A1, 500-B1, 500-C1). Covers operating instructions, safety guidelines, specifications, and support information for safe and efficient lifting operations.
Preview VEVOR Portable Power Electric Hoist User Manual (Models 500-A1, 500-B1, 500-C1)
Comprehensive user manual for VEVOR Portable Power Electric Hoists, models 500-A1, 500-B1, and 500-C1. Includes safety guidelines, technical specifications, installation instructions, maintenance, and troubleshooting.
Preview VEVOR Powder Filling Machine User Manual
Comprehensive user manual for VEVOR Powder Filling Machines, covering safety guidelines, operating instructions, model parameters, structure diagrams, components, maintenance, and troubleshooting.
Preview VEVOR Sliding Glass Pet Door Installation Guide - CWM03 Series
Detailed installation guide and safety instructions for VEVOR sliding glass pet doors, covering models CWM03-M, CWM03-L, CWM03-XL, CWM03-L-B, CWM03-XL-B, CWM03-M-H, CWM03-L-H, and CWM03-XL-H. Learn how to install and use your pet door for sliding glass doors effectively.
Preview VEVOR Geo Grid: Installation Guide and Specifications
Discover the VEVOR Geo Grid, a robust solution designed for soil stabilization and landscape reinforcement. This guide provides essential installation instructions, safety precautions, and detailed specifications for models 50-400, 50-450, 75-500, and 100-450. Learn how VEVOR delivers tough tools at competitive prices for your projects.
Preview VEVOR Ozone Generator SS-Y01: User Manual & Safety Guide
Official user manual and safety instructions for the VEVOR SS-Y01 Ozone Generator. Learn about its applications, parameters, operation, and important safety precautions.
Preview VEVOR SS-Y01 Ozone Generator User Manual and Safety Guide
Discover the VEVOR SS-Y01 Ozone Generator, a powerful appliance for air purification, sterilization, and odor elimination. This guide covers its features, applications, and essential safety instructions for effective use in various environments. Learn about its technical specifications and support resources.