Secop Single Pack KLF5.6CNHS 115-127V 60Hz CSIR
Product Overview
This document provides detailed technical specifications and data for the Secop Single Pack KLF5.6CNHS compressor, designed for 115-127V, 60Hz CSIR applications.
Single pack code number: 195B4752
Included Components
Position | Title | Code | Amount |
---|---|---|---|
1 | Compressor KLF5.6CNHS | 106H3603 | 1 |
2 | Starting capacitor (240μF 125V, 6.3mm) | 117U5002 | 1 |
3 | Starting relay (QLZ-11.6A, overload protector T1217/L6) | 117U7075 | 1 |
4 | KL accessories | 103N1060 | 1 |
5 | Snap-on in quantities | ø7,3 | ø16mm | 118-1919 | 1 |
Company Information
Manufacturer: Secop GmbH
Address: Lise-Meitner-Straße 29, 24941 Flensburg, Germany
Contact: Tel: +49 461 49410 | www.secop.com
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.
Technical Data - Compressor
Model Designation: KLF5.6CNHS
Voltage/Frequency: 115-127V/60Hz 1~
Sales Code: 106H3603
Compressor Design Details
Parameter | Value | Parameter | Value |
---|---|---|---|
Oil type | Polyolester | Refrigerant(s) | R290 |
Oil viscosity | 10.4 cSt | Displacement | 5.6 cm³ / 0.34 cu.in |
Oil quantity | 170 cm³ / 5.7 fl.oz | Compressors on pallet | 100 |
Refr. charge - tech. limit | 200g / 7.1oz | ||
Free gas volume comp. | 1605 cm³ / 54.3 fl.oz | ||
Weight | 9.5 kg / 20.9 lbs | ||
Motor protection | external | ||
Winding resistance main | 2Ω (at 25°C) | ||
Winding resistance aux | 5.3Ω (at 25°C) | ||
Max. winding temp. | 125°C / 257°F | ||
Max. discharge temp. | 130°C / 266°F | ||
Additional note | Very good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. |
Compressor Diagram
Illustration of the Secop KL-Series compressor unit, showing its main body, electrical terminal area, and branding. This visual represents the physical form factor of the compressor.
Configurations and Applications
General Configurations (Conf. 1)
Parameter | Value |
---|---|
Motorconfiguration | CSIR |
Power supply (nominal) | 115-127V/60Hz |
Number of phases | 1 |
Voltage range | 95-140V |
Approvals | UL, CCC |
Starting torque | HST |
Note | -/- |
Applications (Conf. 1)
Parameter | Value |
---|---|
Refrigerant | R290 |
Application | LBP+MBP |
System cooling | fan 3m/s |
Hot gas defrost | OK |
Long interval pull down | OK |
Electrical Data (Conf. 1)
Parameter | Value |
---|---|
Starting device type | relay |
Run capacitor | -/- |
Start capacitor | 240μF |
LRA (locked rotor amps / 4s/ U(N)) | 31.1A |
RLA (rated load amps / 1s/ U(N)) | 4.3A |
Cut in current (U(N)) | 27.8A |
Compressor Dimensions and Connectors
Housing Dimensions
Dimension | Value (mm) | Value (in) |
---|---|---|
A Height | 182 | 7.17 |
B Height | 175 | 6.89 |
C Length shell | 198 | 7.8 |
D Length w. cover | 238 | 9.37 |
E Width | 160 | 6.3 |
Compressor Dimensions Diagram
Schematic illustrating the external dimensions of the compressor, labeled A through E, with measurements provided in both millimeters and inches. It also shows the relative positions of key components like the body, cover, and electrical connections.
Connectors Data
Parameter | Suction (X) | Discharge (Y) | Process (Z) | ||||||
---|---|---|---|---|---|---|---|---|---|
[mm] | [in] | Material | [mm] | [in] | Material | [mm] | [in] | Material | |
Diameter | ø8.11-8.29 | ø0.32-0.33 | copper | ø6.41-6.59 | ø0.25-0.26 | copper | ø6.41-6.59 | ø0.25-0.26 | copper |
Horizontal angle | +2° | 35° | +2° | 13° | 0° | 40° | |||
Vertical angle | 30° | 145° | |||||||
Position l/h/w | 119/73/59 | 4.7/2.9/2.3 | 117/107/66 | 4.6/4.2/2.6 | -88/101/71 | -3.5/4/2.8 | |||
Straight tube l. | 14 | 0.5 | 14 | 0.5 | 14 | 0.5 |
Compressor Fixation
Baseplate | Large holes | Small holes | |||
---|---|---|---|---|---|
[mm] | [inch] | [mm] | [inch] | [mm] | [inch] |
Bl: 204 | 8.03 | øL: 165 | 6.5 | Sl: 170 | 6.7 |
Bw: 132 | 5.2 | Lw: 101.6 | 4 | Sw: 70 | 2.76 |
øE: ø9.7 | ø0.38 | øS: ø19 | ø0.75 | øS: ø16 | ø0.63 |
Compressor Fixation Diagram
Illustration showing the compressor's baseplate with dimensions for mounting holes (Bl, Bw, E, L, LW, S, Sl, Sw) in both metric and imperial units. It also details the bolt joint and snap-on connection types, including associated hardware like washers, compressor base, sleeve, cabinet base, and rubber grommets.
Mounting Accessories
Accessory Type | Part Number (One Comp.) | Part Number (Multi Pack) |
---|---|---|
Bolt joint | M6 | ø16mm | 118-1917 | 118-1918 |
Bolt joint | ø1/4" | ø16mm | 118-1946 | |
Bolt joint | ø1/4" | ø19mm | 118-1949 | |
Snap-on | ø7,3 | ø16mm | 118-1947 | 118-1919 |
Application notes: Provision for PE Grounding is located at the PE Stamp on the compressor.
Electrical and Operational Data
Configuration Summary
Parameter | Value |
---|---|
Motorconfiguration | CSIR |
Power supply (nominal) | 115-127V/60Hz 1~ |
Refrigerant | R290 |
Application | LBP+MBP |
Voltage range | 95-140V |
Starting torque | HST |
Approvals | UL, CCC |
Ambient and Machine Room Temperatures
Parameter | Range |
---|---|
Ambient temperature range | 10 - 43°C / 50 - 110°F |
Machine room temperature range | 10 - 48°C / 50 - 119°F |
Compressor cooling | fan 3m/s |
Electrical Accessories / Wiring Diagram
Schematic illustrating the electrical connections and components for the compressor. It shows the layout of the current relay (a5), start capacitor (c), and cover/clamp/screws (b, d), along with their part numbers and potential alternative components. The diagram also includes a simplified wiring schematic indicating connections.
Operation Pressure Range
Condensing Pressure vs. Evaporation Pressure Graphs
Two graphs illustrating the compressor's operating limits. The top graph plots Condensing Pressure (sat. temp.) against Evaporation Pressure (sat. temp.), showing zones for continuous and transitory operation. The bottom graph plots Condensing Pressure (bara) against Evaporation Pressure (bara) with similar operational zones indicated.
Performance Data
Optimization + Standard Conditions
Conditions | Cooling capacity | COP | EER | P1 [W] | Current [A] | Ref. mass flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W/W] | [Btu/Wh] | [kcal/Wh] | ||||
ASHRAE LBP [-23°C / -10°F] pc=54/130, RGT=32/90, Tliq=32/90 |
326.8 | 1116 | 281.3 | 1.57 | 5.35 | 1.35 | 1.57 | 5.35 | 1.35 | 208.7 | 2.75 | 3.31 |
cecomaf LBP [-25°C / -13°F] pc=55/131, RGT=55/131, Tliq=55/131 |
245.0 | 837 | 210.8 | 1.22 | 4.18 | 1.05 | 1.22 | 4.18 | 1.05 | 200.3 | 2.70 | 3.05 |
EN12900 LBP [-35°C / -31°F] pc=40/104, RGT=40/104, Tliq=40/104 |
182.9 | 625 | 157.4 | 1.21 | 4.15 | 1.05 | 1.21 | 4.15 | 1.05 | 150.6 | 2.44 | 2.09 |
ASHRAE MBP [-7°C / 20°F] pc=54/130, RGT=35/95, Tliq=46/115 |
587.6 | 2007 | 505.7 | 2.05 | 7.01 | 1.77 | 2.05 | 7.01 | 1.77 | 286.1 | 3.25 | 6.70 |
cecomaf MBP [-10°C / 14°F] pc=55/131, RGT=55/131, Tliq=55/131 |
466.5 | 1593 | 401.5 | 1.71 | 5.83 | 1.47 | 1.71 | 5.83 | 1.47 | 273.2 | 3.16 | 5.90 |
EN12900 MBP [-10°C / 14°F] pc=45/113, RGT=45/113, Tliq=45/113 |
518.9 | 1772 | 446.5 | 2.08 | 7.11 | 1.79 | 2.08 | 7.11 | 1.79 | 249.1 | 3.00 | 6.37 |
Performance Tables
Conditions [°C/°F] | Cooling capacity | COP | EER | P1 [W] | Current [A] | Ref. mass flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W/W] | [Btu/Wh] | [kcal/Wh] | ||||
cond. pressure pc=45/113 [-34°C / -30°F] |
180.8 | 617 | 155.6 | 1.16 | 3.97 | 1.00 | 1.16 | 3.97 | 1.00 | 155.5 | 2.47 | 2.03 |
return gas temp. RGT=32/90 [-23°C / -10°F] |
310.2 | 1059 | 266.9 | 1.55 | 5.30 | 1.34 | 1.55 | 5.30 | 1.34 | 199.9 | 2.69 | 3.50 |
[-15°C / 5°F] | 443.9 | 1516 | 382.0 | 1.91 | 6.54 | 1.65 | 1.91 | 6.54 | 1.65 | 231.9 | 2.88 | 5.05 |
[-4°C / 25°F] | 675.0 | 2305 | 580.9 | 2.53 | 8.64 | 2.18 | 2.53 | 8.64 | 2.18 | 266.8 | 3.12 | 7.78 |
liquid temp Tliq=45/113 [0°C / 32°F] |
771.1 | 2633 | 663.6 | 2.80 | 9.55 | 2.41 | 2.80 | 9.55 | 2.41 | 275.7 | 3.18 | 8.94 |
[7.2°C / 45°F] | 971.2 | 3317 | 835.8 | 3.39 | 11.59 | 2.92 | 3.39 | 11.59 | 2.92 | 286.1 | 3.26 | 11.41 |
cond. pressure pc=55/131 [-34°C / -30°F] |
155.2 | 530 | 133.6 | 1.02 | 3.48 | 0.88 | 1.02 | 3.48 | 0.88 | 152.5 | 2.45 | 1.92 |
return gas temp RGT=32/90 [-23°C / -10°F] |
264.7 | 904 | 227.8 | 1.27 | 4.33 | 1.09 | 1.27 | 4.33 | 1.09 | 208.8 | 2.75 | 3.30 |
[-15°C / 5°F] | 381.3 | 1302 | 328.2 | 1.52 | 5.21 | 1.31 | 1.52 | 5.21 | 1.31 | 250.1 | 3.01 | 4.79 |
[-4°C / 25°F] | 586.9 | 2004 | 505.1 | 1.97 | 6.72 | 1.69 | 1.97 | 6.72 | 1.69 | 298.4 | 3.34 | 7.49 |
liquid temp Tliq=55/131 [0°C / 32°F] |
673.2 | 2299 | 579.4 | 2.16 | 7.37 | 1.86 | 2.16 | 7.37 | 1.86 | 312.2 | 3.44 | 8.65 |
[7.2°C / 45°F] | 854.3 | 2918 | 735.2 | 2.57 | 8.79 | 2.22 | 2.57 | 8.79 | 2.22 | 331.9 | 3.60 | 11.13 |
Component Assembly and Service Information
KL Compressors Component Assembly Diagrams
Series of diagrams illustrating the assembly of electrical components, including the compressor unit itself, terminal boxes, relays, capacitors, and covers. These visuals show how various parts are connected and fitted together, with part numbers indicated for reference (e.g., 8917-2, 8916-5, 8918-4).
This section highlights important information for servicing compressors using R290 refrigerant. It includes safety warnings and procedural illustrations.
Safety Illustrations:
- A diagram showing a hand with a tool being crossed out, indicating an incorrect or unsafe action.
- An exclamation mark symbol, signifying an important warning or caution.
- A diagram showing a hand correctly using a tool with a checkmark, indicating a proper procedure.
General Disclaimer
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. Visit www.secop.com for more information.