Secop NLE11MN Compressor Technical Data

Model: NLE11MN

Voltage: 115-127V 60Hz

Sales Code: 105H5980

Single Pack Information

Single Pack Code Number: 195B4359

PositionTitleCodeAmount
1Compressor NLE11MN105H59801
2Starting relay117U70201
3Starting capacitor (240uF 125V, 6.3mm)117U50731
4Cord relief103N10101
5Cover103N20111
6Bolt joint for one compressor | M6 | diameter 16mm118-19171

Compressor Design

Oil type: Polyoester

Oil viscosity: 32cST

Oil quantity: 298cm³ / 10.1fl.oz

Refrigerant(s): R290

Displacement: 11.15cm³ / 0.68cu.in

Refr. charge - tech. limit: 400g / 14.1oz

Free gas volume comp.: 2360cm³ / 79.8fl.oz

Weight: 12.14kg / 26.8lbs

Motor protection: 1# internal

Winding resistance main: 0.85Ω (at 25°C)

Winding resistance aux: 4.17Ω (at 25°C)

Max. winding temp.: 125°C / 257°F

Max. discharge temp.: 130°C / 266°F

Compressors on pallet: 80

General Configurations with NLE11MN

ParameterConf. 1Conf. 2Conf. 3Conf. 4
MotorconfigurationCSIRCSIRRSCRRSCR
Power supply (nominal)115V/60Hz115V/60Hz115V/60Hz115V/60Hz
Number of phases1111
Voltage range95-127V95-135V95-127V95-135V
ApprovalsUL, CCCUL, CCCUL, CCCUL, CCC
Starting torqueHSTHSTLSTLST
Note-/--/--/--/-

Applications with NLE11MN

ParameterConf. 1Conf. 2Conf. 3Conf. 4
RefrigerantR290R290R290R290
ApplicationMBPMBPMBPMBP
System coolingfan 3m/sfan 3m/sfan 3m/sfan 3m/s
Hot gas defrostOKOKOKOK
Long interval pull downOKOKOKOK

Electrical Data - Configurations with NLE11MN

ParameterConf. 1Conf. 2Conf. 3Conf. 4
Starting device typerelayrelayPTCPTC
Run capacitor-/--/-23.5uF23.5uF
Start capacitor240uF240uF-/--/-
LRA (locked rotor amps / 4s)40.23A40.23A41.7A41.7A
RLA (rated load amps / 1s)8.37A8.37A8.37A8.37A
Cut in current40.23A40.23A51.83A51.83A

Compressor Dimensions

Housing Dimensions

DimensionValue (mm / in)
A Height203mm / 7.99in
B Height197mm / 7.76in
C Length shell205mm / 8.07in
D Length w. cover254mm / 10in
E Width166mm / 6.54in

Connectors

ParameterSuction (X)Discharge (Y)Process (Z)
Diameter [mm]øi 8.11-8.29øi 6.41-6.59øi 6.41-6.59
(i:inside, o:outside) [in]øi 0.32-0.33øi 0.25-0.26øi 0.25-0.26
Materialcoppercoppercopper
Horizontal angle+2°
Vertical angle+2°15°155°
Position l/h/w [mm]132/69/5794/102/81-109/94/72
Position l/h/w [in]5.2/2.7/2.23.7/4/3.2-4.3/3.7/2.8
Straight tube l. [mm]121212
Straight tube l. [in]0.50.50.5

Diagram Description: A schematic shows the compressor housing with labels A, B, C, D, E indicating height, length, and width. Connector ports X, Y, Z are indicated with their angles and diameters. A diagram illustrates the orientation of connectors with vertical and horizontal angles.

Compressor Fixation

Diagram Description: Illustrations show methods for compressor fixation. One diagram depicts a 'Bolt joint' assembly with a baseplate, compressor, cabinet base, bolt, washer, nut, sleeve, and rubber grommet. Another diagram illustrates a 'Snap-on' assembly with a compressor base, clip, steel pin, cabinet base, washer, and rubber grommet. Tables provide dimensions for baseplates, large holes, and small holes.

Mounting Accessories

AccessoryOne Comp.Multi Pack
Bolt joint | M6 | ø16mm118-1917118-1918
Bolt joint | ø1/4" | ø16mm118-1946118-1919
Bolt joint | ø1/4" | ø19mm118-1949
Snap-on | ø7.3 | ø16mm118-1947

Operating Conditions and Performance

Ambient/Machine Room Temperatures

Ambient temperature range: 10 - 43°C / 50 - 110°F

Machine room temperature range: 10 - 48°C / 50 - 119°F

Compressor cooling: fan 3m/s

Operation Pressure Range

Diagram Description: Two graphs illustrate the operation pressure ranges. The top graph shows Condensing Pressure (sat. temp.) versus Evaporation Pressure (sat. temp.), with lines indicating continuous and transitory operation. The bottom graph shows Condensing Pressure (bara) versus Evaporation Pressure (bara) for different temperature ranges.

Optimization + Standard Conditions

Diagram Description: A table presents performance data under various optimization and standard conditions, including evaporating and condensing pressures, return gas temperature, liquid temperature, cooling capacity (W, Btu/h, kcal/h), COP (W/W, Btu/Wh, kcal/Wh), EER, power consumption (P1 in W), current consumption (I in A), and reference mass flow (m in kg/h). Data is provided for different standards like ASHRAE MBP, cecomaf MBP, EN12900 MBP, and ARI540 MBP.

ConditionsCooling Capacity [W]Cooling Capacity [Btu/h]Cooling Capacity [kcal/h]COP [W/W]EER [Btu/Wh]EER [kcal/Wh]P1 [W]I [A]m [kg/h]
-7°C / 20°F
pc= 54/131
RGT= 35/95
Tliq= 46/115
1202.741071035.12.046.971.76589.17.1513.72
-10°C / 14°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
959.73278825.91.715.831.47561.86.9612.14
-10°C / 14°F
pc= 45/113
RGT= 20/68
Tliq= 45/113
1058.43615910.92.046.961.75519.16.7712.99
-7°C / 20°F
pc= 49/120
RGT= 18/65
Tliq= 49/120
1124.63841967.82.006.831.72562.17.0114.60
-10°C / 14°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
1101.83763948.22.127.251.83519.16.7712.61
-25°C / -13°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
594.02029511.21.454.941.24410.86.096.70

Performance Tables

Diagram Description: Detailed performance tables provide data across a range of operating conditions (condensing pressure, return gas temperature, liquid temperature) for specific evaporating pressures. Columns include Cooling Capacity (W, Btu/h, kcal/h), COP (W/W, Btu/Wh, kcal/Wh), EER, Power (P1 in W), Current (I in A), and Mass Flow (m in kg/h).

ConditionCooling Capacity [W]Cooling Capacity [Btu/h]Cooling Capacity [kcal/h]COP [W/W]EER [Btu/Wh]EER [kcal/Wh]P1 [W]I [A]m [kg/h]
-25°C / -13°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
594.02029511.21.454.941.24410.86.096.70
-23°C / -10°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
642.12193552.61.525.181.31422.96.177.25
-15°C / 5°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
912.13115784.91.896.441.62483.76.5410.38
-9°C / 15°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
1124.43840967.72.157.341.85523.06.7912.87
0°C / 32°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
1558.653231341.32.679.112.29584.57.2118.08
4.4°C / 40°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
1799.861471548.92.9510.082.54609.97.3821.03
10°C / 50°F
pc= 45/113
RGT= 32/90
Tliq= 45/113
2139.173051840.93.3611.462.89637.37.5825.28
-25°C / -13°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
498.11701428.71.184.031.01422.56.096.20
-23°C / -10°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
542.71853467.11.244.231.07438.16.186.77
-15°C / 5°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
789.02695679.01.535.221.32515.96.669.92
-9°C / 15°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
979.93347843.31.735.901.49566.87.0012.40
0°C / 32°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
1367.346701176.72.117.201.82648.27.5717.56
4.4°C / 40°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
1582.154031361.52.327.911.99683.07.8320.49
10°C / 50°F
pc= 55/131
RGT= 32/90
Tliq= 55/131
1884.164351621.52.618.912.24722.48.1324.70

Electrical Accessories / Wiring Diagram

Diagram Description: Schematics illustrate the electrical connections and components for different configurations (CSIR and RSCR). These include diagrams showing the main winding, winding protector, start winding, and associated components like relays, capacitors, plastic covers, and cord reliefs. Component lists with part numbers are provided for each configuration.

Components (Example for Conf. 1)

Alternative Components (Example for Conf. 1)

Similar component lists are provided for Conf. 3 and Conf. 4, detailing e-PTC starters and run capacitors.

Service and Repair Information

Diagram Description: Safety warnings are displayed for refrigerants R600a and R290, indicating flammability hazards ([alert] Warning: Flammable refrigerant). Instructions for brazing suction connectors are provided with diagrams showing correct and incorrect methods ([forbidden] symbol for incorrect, [approved] symbol for correct), along with recommended brazing solder (phosphor (LP7) or silver) and maximum temperature limits (max. 150°C/302°F at socket). A reference to a specific product bulletin 'Brazing on Suction Connectors' is included.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4359 GPL Ghostscript 10.05.1

Related Documents

PreviewSecop KLF4.8CNH Compressor Technical Data and Specifications
Comprehensive technical specifications, performance data, dimensions, and configuration details for the Secop KLF4.8CNH hermetic reciprocating compressor. Covers CSIR (Conf. 1) and RSCR (Conf. 2) variants for 115-127V, 60Hz operation with R290 refrigerant.
PreviewSecop Single Pack KLF6.6CNH 115-127V 60Hz CSIR Technical Data
Detailed technical specifications, dimensions, electrical data, performance tables, and configuration details for the Secop KLF6.6CNH compressor, designed for 115-127V, 60Hz, CSIR and RSCR applications using R290 refrigerant.
PreviewSecop NLE8.8CN Compressor Technical Data and Specifications
Detailed technical specifications, performance data, electrical configurations, and application notes for the Secop NLE8.8CN compressor, designed for 115-127V/60Hz operation with R290 refrigerant.
PreviewSecop NLE8.0CN Compressor Technical Data Sheet | 115-127V 60Hz CSIR
Detailed technical specifications, dimensions, electrical data, performance tables, and application notes for the Secop NLE8.0CN compressor, designed for 115-127V, 60Hz, CSIR applications using R290 refrigerant.
PreviewSecop NLE8.0CN Compressor Technical Datasheet - 115V/60Hz
Comprehensive technical datasheet for the Secop NLE8.0CN compressor, covering single pack details, compressor design specifications, various configurations (CSIR, RSIR, RSCR), electrical data, dimensions, performance tables, operating pressure ranges, wiring diagrams, and service information for 115V/60Hz operation.
PreviewSecop KLF5.6CNHS Single Pack Compressor: Technical Specifications and Data
Detailed technical data sheet for the Secop KLF5.6CNHS single pack compressor, covering specifications, dimensions, electrical data, performance charts, and component information for 115-127V 60Hz CSIR applications.
PreviewSecop NLE10CNT Compressor Technical Data and Specifications
Detailed technical data, specifications, and configuration options for the Secop NLE10CNT compressor, including performance tables, dimensions, and electrical information for various configurations.
PreviewSecop NLE8.0CN Compressor Technical Data and Specifications
Detailed technical data, specifications, configurations, and performance tables for the Secop NLE8.0CN compressor, including electrical accessories, dimensions, and application notes. Suitable for R290 refrigerant.