KEYENCE IL-1000 Amplifier Unit
Data Sheet
The KEYENCE IL-1000 is an amplifier unit designed for DIN-rail mounting. It serves as the main unit in a system, compatible with expansion units for expanded functionality.
The unit is depicted as a compact, rectangular device with a dark casing, featuring connectors and indicators on its front and rear panels. It is marked with the KEYENCE logo and the CE certification symbol.
Specifications
Model | IL-1000 |
---|---|
Type | DIN-rail mount |
Main unit/Expansion unit | Main unit |
Head compatibility | Compatible |
Display | Minimum displayable unit: IL-S025/IL-030: 1 µm, IL-S065/IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 μm Display range: IL-S025/IL-030/IL-S065/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable), IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable) Display rate: Approx. 10 times/sec. |
Analogue voltage output | ±5 V, 1 to 5 V, 0 to 5 V. Output impedance 100 Ω [1] |
Analogue current output | 4 to 20 mA. Maximum load resistance of 350 Ω [1] |
Control input | Non-voltage input [2] Options include: Bank switch input, Zero-shift input, Stop emission input, Timing input, Reset input. |
Control output | Judgment output: Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible) [3] Alarm output: Open collector output (NPN, PNP changeover possible/N.C.) [3] |
Current | Power voltage: 10 to 30 VDC ripple (P-P) 10% included, Class 2 [4] Power consumption: 2300 mW or less (at 30 V: 77 mA or less) |
Environmental resistance | Pollution degree: 2 Ambient temperature: -10 to +50 °C (No condensation or freezing) Relative humidity: 35 to 85% RH (No condensation) Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
Material | Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC |
Weight | Approx. 150 g (including attachments) |
Notes:
- [1] Select and use one of ±5 V, 1 to 5 V, 0 to 5 V or 4 to 20 mA.
- [2] Assign an input of your choice to the 4 external input lines before using.
- [3] The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit). The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit).
- [4] If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.
Dimensions
The IL-1000 unit is designed for DIN-rail mounting. Key physical dimensions are provided:
- Overall unit length (including connector): Approximately 76.3 mm (main body) + 28.3 mm (end) = 104.6 mm.
- Unit width: Approximately 47 mm.
- Unit height: Approximately 42.4 mm.
- Cable length: 2 meters.
- Mounting requires a minimum clearance of 15 mm on each side.
- When the cover is opened, the dimension can extend up to a maximum of 109.2 mm.
I/O Circuit Connection Diagram
The following diagram illustrates the wiring connections for the IL-1000 amplifier unit. This diagram is crucial for proper installation and operation.
Wiring Diagram:
- Brown: 10 to 30 VDC [4]
- Blue: 0 V [1]
- Black: HIGH judgment output
- White: LOW judgment output
- Grey: GO judgment output
- Green: Alarm output
- Light blue: Analogue output + [2]
- Orange: Analogue output GND [2]
- Pink: External input 1 (zero shift input) [3]
- Yellow: External input 2 (reset input) [3]
- Pink/purple: External input 3 (timing input) [3]
- Purple: External input 4 (not used) [3]
Additional Notes for Wiring:
- The brown, blue, and light blue cables are not provided in the IL-1050/IL-1550 unit (expansion unit). Power is supplied to the expansion unit from the IL-1000/IL-1500 unit (main unit).
- For analogue output, selection is possible between OFF (not used), 0 to 5 V, ±5 V, 1 to 5 V, or 4 to 20 mA.
- For external input, options include bank A input, bank B input, laser emission stop input, or OFF (not used).
- For detailed information, refer to the User's Manual.
- If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.