OMRON F3SG-SR-K Safety Light Curtain

Instruction Sheet

Thank you for purchasing the F3SG-SR Series Safety Light Curtain (hereinafter referred to as the "F3SG-SR"). Ensure the F3SG-SR is handled by a "Responsible Person" who is well aware of and familiar with the machine to be installed. The term "Responsible Person" in this document refers to a person qualified, authorized, and responsible for securing "safety" in the design, installation, operation, maintenance, and disposal processes of the machine. It is assumed that the F3SG-SR will be used properly according to the machine's installation environment, performance, and function. The Responsible Person should conduct a risk assessment on the machine and determine the suitability of this product before installation. Thoroughly read this document and reference manuals for F3SG-SR to understand and effectively use the descriptions before installing and operating the product. Keep this document accessible for operators whenever necessary. This device is electro-sensitive protective equipment designed for protecting the human body.

© OMRON Corporation 2020-2022 All Rights Reserved. Original instructions

Instructions in EU languages and a signed EU Declaration of Conformity are available on our website at www.industrial.omron.eu/safety.

Declaration of Conformity

OMRON declares that the F3SG-SR conforms to the requirements of the following EU Directives and UK Legislations:

EU: Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU.

UK: 2008 No 1597 Machinery (Safety), 2016 No 1091 EMC, 2012 No 3032 RoHS.

Safety Standards

The F3SG-SR is designed and manufactured according to the following standards:

  • EN61496-1 (Type 4 and Type 2 ESPE)
  • EN 61496-2 (Type 4 and Type 2 AOPD)
  • EN61508-1 through -4 (SIL 3 for Type 4 and SIL 1 for Type 2)
  • EN ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)

Dispose in accordance with applicable regulations.

Safety Precautions

Indications and Meanings for Safe Use

The precautions listed in this document, indicated by alert symbols and statements, must be followed for the safe use of the F3SG-SR. Failure to follow all precautions and alerts may result in unsafe use or operation. Thoroughly read this document before using the F3SG-SR. The following words and symbols are used in this document:

  • DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
  • WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • ℹ️ (Information): Indicates important information for safe use.

Alert Statements

DANGER

Ensure the machine can be controlled correctly and as intended. Also, ensure the machine can be stopped immediately at any time during the operation cycle without danger to machine operators if the machine behavior does not meet safety-related requirements. Otherwise, continued use of the machine may result in serious injury or death.

WARNING

Users: The F3SG-SR must be installed, configured, and incorporated into a machine control system by a sufficiently trained and qualified person. An unqualified person may not be able to perform these operations properly, which may cause a person to go undetected, resulting in serious injury.

Machines: Do not use this sensor for machines that cannot be stopped quickly by electrical control. For example, do not use it for a pressing machine that uses a full-rotation clutch. Otherwise, the machine may not stop before a person reaches the hazardous part, resulting in serious injury. To use the F3SG-SR in PSDI mode (initiation of cyclic operation by a presence sensing device), you must configure an appropriate circuit between the F3SG-SR and the machine. For details about PSDI, refer to OSHA 1910.217, IEC 61496-1, and other relevant standards and regulations.

Installation

WARNING

Ensure the Responsible Person tests the operation of the F3SG-SR and F39-SGIT-IL3 after installation to verify they operate as intended. Stop the machine until the test is complete. Unintended installation, wiring, or function settings may cause a person to go undetected, resulting in serious injury.

Ensure the F3SG-SR is installed at the safety distance from the hazardous part of the machine. Otherwise, the machine may not stop before a person reaches the hazardous part, resulting in serious injury.

Install a protective structure so that the hazardous part of a machine can only be reached by passing through the sensor's detection zone. If access to the hazardous part by reaching over the detection zone of a vertically mounted F3SG-SR cannot be excluded, the height of the detection zone and the safety distance shall be determined considering such a risk. Install the sensors so that part of a person is always present in the detection zone when working in a machine's hazardous zones. If a person can step into the hazardous zone of a machine and remain behind the F3SG-SR's detection zone, configure the system with the Restart Interlock function. Failure to do so may result in serious injury due to unexpected startup.

Install the reset switch in a location providing a clear view of the entire hazardous zone and where it cannot be activated from within the hazardous zone.

Install the pre-reset switch always within the hazardous zone and where it cannot be activated from outside the hazardous zone.

The F3SG-SR cannot protect a person from an object flying from the hazardous zone. Install protective cover(s) or fence(s).

Install a protective structure to cover the entire blanked zone to prevent personnel approach to the hazardous part of the machine through the blanked zone.

Detection capability increases when Fixed Blanking, Floating Blanking, or Reduced Resolution functions are used. When these functions are used, the safety distance calculation must be based on the increased detection capability. Otherwise, the machine may not stop before a person reaches the hazardous part, resulting in serious injury.

If detection capability increases and a human body may pass a detection zone to reach a hazardous source, additional safety protection equipment, such as a safety fence, must be installed.

The Muting and Override functions disable the device's safety functions. Setting the Muting Time Limit parameter to infinite may disable safety functions for a long time. Install the F3SG-SR, muting sensor, and physical barrier, and configure time settings for Muting and Override so that an operator does not enter the hazardous zone when Muting and Override are active.

Install muting sensors so they can distinguish between an object allowed to pass through the detection zone and a person. If the Muting function is activated by detecting a person, the machine may not stop operating, resulting in serious injury.

Muting lamps indicating the state of Muting and Override functions must be installed where they are clearly visible to workers from all operating positions.

Use two independent input devices for muting inputs. Failure to do so may cause the MUTING state due to a single muting sensor's failure.

Install the switch to activate the Override function in a location providing a clear view of the entire hazardous zone and where it cannot be activated from within the hazardous zone. Ensure that nobody is in the hazardous zone before activating the Override function.

Connect an override cancel switch to the RESET line when using the Override function. Otherwise, the OVERRIDE state may not be released by the override cancel switch, resulting in serious injury.

When a muting error occurs with a workpiece blocking the F3SG-SR, there are two methods to forcibly remove the workpiece: 1) Manual operation (with additional safety measure); or 2) Override function (Override at Normal Operation / Override upon Startup). Only one of these methods must be used. If they are used simultaneously, the Override may activate at an unexpected timing.

Install the F3SG-SR so it is not affected by reflective surfaces. Failure to do so may hinder detection, resulting in serious injury.

When using more than one set of F3SG-SR units in adjacent areas, the emitter of one unit may interfere with the receiver of another, causing safety functions to stop working properly. Install, configure, and maintain them to prevent mutual interference.

To change the response time, calculate the safety distance based on the setting. Otherwise, the machine may not stop before a person reaches the hazardous part, resulting in serious injury.

Do not use the F3SG-SR with mirrors in a retro-reflective configuration. Doing so may hinder detection. It is possible to use mirrors to alter the detection zone to a 90-degree angle.

Diagram showing two mirror configurations: one labeled 'Position with retro-reflection' which is cautioned against, and another labeled 'Position with detection zone bent at 90°' which is acceptable.

Wiring

WARNING

When using the PNP output, connect the load between the output and the 0 V line. When using the NPN output, connect the load between the output and the +24 VDC line. Connecting the load between the output and a different power supply line from the above will result in a dangerous condition because the operation mode of safety outputs is reversed to "Dark-ON".

When using the PNP output, do not ground the +24 VDC line. When using the NPN output, do not ground the 0 V line. Otherwise, a ground fault may turn the safety outputs ON, resulting in a failure to stop the machine.

Configure the system using the optimal number of safety outputs that satisfy the requirements of the necessary safety category.

Do not connect any line of the F3SG-SR to a DC power supply higher than 24 VDC +20%. Also, do not connect it to an AC power supply. Failure to do so may result in electric shock.

Ensure wiring is performed while the power supply is OFF.

Do not use the output signal of the auxiliary output or IO-Link output for safety applications. Failure to do so may result in serious injury if the F3SG-SR fails.

Double or reinforced insulation from hazardous voltage must be applied to all input and output lines. Failure to do so may result in electric shock.

Extension of the cable must be within a specified length. If it is not, safety functions may not work properly, resulting in danger.

For the F3SG-SR to comply with IEC 61496-1 and UL 508, the DC power supply unit must satisfy all of the following conditions:

  • The DC power supply operates within the rated power voltage (24 VDC ± 20%).
  • The DC power supply has tolerance against the total rated current of devices if it is connected to multiple devices.
  • The DC power supply complies with EMC directives (industrial environment).
  • Double or reinforced insulation is applied between the primary and secondary circuits.
  • The DC power supply has an automatic recovery type of overcurrent protection characteristics.
  • Output holding time is 20 ms or longer.
  • The DC power supply satisfies output characteristic requirements for class 2 circuit or limited voltage current circuit defined by UL 508.
  • The DC power supply complies with laws and regulations regarding EMC and electrical equipment safety of the country or region where the F3SG-SR is used. (For example, in the EU, the power supply must comply with the EMC Directive and the Low Voltage Directive.)

Settings

WARNING

Ensure the Responsible Person tests the operation of the F3SG-SR after setting with the DIP Switch on the F39-SGIT-IL3, Teach-in, or SD Manager 3 to verify that the F3SG-SR operates as intended. Stop the machine until the test is complete. Unintended settings may cause a person to go undetected, resulting in serious injury.

Other

WARNING

Perform daily and 6-month inspections for all F3SG-SR as described in the User's Manual or the Quick Installation Manual. When using the F3SG-SR in cascade connection, perform inspections for every connected F3SG-SR. Otherwise, the system may fail to work properly, resulting in serious injury.

Do not attempt to disassemble, repair, or modify the product. Doing so may cause the safety functions to stop working properly.

Do not use the product in environments where flammable or explosive gases are present. Doing so may result in explosion.

Do not use the F3SG-SR in environments where strong electromagnetic fields may be produced. Doing so may cause the safety functions to stop working properly.

Precautions for Safe Use

Observe the following precautions necessary for ensuring safe use of the product.

Storage conditions and installation environment

Do not install, use, or store the product in the following types of environments:

  • Areas exposed to intense interference light, such as direct sunlight.
  • Areas with high humidity where condensation is likely to occur.
  • Areas where corrosive gases are present.
  • Areas exposed to vibration or shock levels higher than specified.
  • Areas where the pollution degree is harsher than 3, such as outdoor environments.
  • Areas where the product may get wet with liquid that can dissolve adhesive.

When carrying and installing the product, ensure two people work together according to the product's weight to prevent it from falling. Otherwise, injury and/or property damage may occur.

Wiring and installation
  • The rated life of the LEDs used for this product is 6 years.
  • Loads must satisfy both of the following conditions:
    • Not short-circuited.
    • Not used with a current higher than the rating.
  • Ensure mounting brackets, fixing screws, and connectors are properly secured with the torque recommended in the User's Manual or the Quick Installation Manual.
  • Bending radii of cables must be equal to or higher than specified minimum values.
  • When replacing cables with those other than dedicated cables, use cable connectors that provide a protection grade of IP54 or higher.
  • To extend a cable length with a cable other than the dedicated cable, use a cable with the same or superior specifications.
  • Route the input/output lines for the F3SG-SR separately from high-potential power lines or through an exclusive conduit.
  • Ensure foreign material such as water, oil, or dust does not enter the F39-SGIT-IL3 or the connector while the cover of the DIP Switch on the F39-SGIT-IL3 is removed.
  • The F39-SGIT-IL3 is dedicated to the F3SG-SR/PG series. Do not use it for equipment other than F3SG-SR/PG.
Water-proof

Do not use the product with degraded protective structures such as swelling or cracks in housing and/or sealing components. Otherwise, water or other substances may enter the product, resulting in a risk of corruption or burning.

Disposal

Dispose of the product in accordance with the relevant rules and regulations of the country or area where the product is used.

Precautions for Correct Use

Observe the precautions described below to prevent operation failure, malfunctions, or undesirable effects on product performance.

Storage conditions and installation environment
  • Do not install, use, or store the product in the following types of environments:
    • Areas with temperatures or humidity outside the specified range.
    • Areas submerged in water or subject to rainwater.
  • This is a Class A product (for industrial environments). In residential areas, it may cause radio interference, in which case the Responsible Person may be required to take adequate measures to reduce interference.
  • Use the sensor after water droplets have been removed when water droplets such as condensation have adhered to the optical surface of the sensor.
Wiring and installation
  • Properly perform wiring after confirming the signal names of all terminals.
  • Do not operate the control system until 3 seconds or more have passed after turning ON the power of the F3SG-SR.
  • When using a commercially available switching regulator power supply, ensure the PE terminal (protective earth terminal) is grounded.
  • Install the emitter and receiver in the same vertical direction.
  • Use brackets of specified quantities and locations according to the dimensions. If the described brackets are not used, ratings and performance cannot be met.
  • Do not install the F3SG-SR close to a device that generates high-frequency noise. Otherwise, take sufficient blocking measures.
  • Sharing the power supply with other devices may cause the F3SG-SR to be affected by noise or voltage drop. It is recommended that the F3SG-SR use a power supply dedicated for safety components, not shared with other devices.
  • Do not change the scan code during normal operation. The F3SG-SR transitions to lockout.
  • Do not apply load to the connectors.
  • The operating range of the F3SG-SR-K is about 20% lower than the normal model.
Cleaning
  • Do not use thinner, benzene, or acetone for cleaning, as they affect the product's resin parts and housing paint.
  • Use a soft cloth that is dry or wetted with clean water for cleaning. Do not use solvents.
Object detection

The F3SG-SR cannot detect transparent and/or translucent objects.

Settings
  • Do not operate the DIP Switch on the F39-SGIT-IL3 during normal operation of the F3SG-SR. Otherwise, the F3SG-SR enters the LOCKOUT state.
  • Do not operate the DIP Switch and Push Switch on the F39-SGIT-IL3 with tools that may damage the product.
  • Ensure the F3SG-SR is in the SETTING state when making a change to the setting.

LED Indicators

LED Indicators of the Emitter

LocationIndicatorNameColorIlluminatedBlinking
1C or CODEScan codeGreenCode A is selected
OFFAutomatic interference prevention by wired synchronization being performed
2E or ERRLockoutRedLOCKOUT state. The indicator is illuminated in the emitter of another sensor segment than that having a lockout error (between the emitter and receiver in the Wired Synchronization)LOCKOUT state. The indicator is illuminated in the emitter of a sensor segment having a lockout error
3L or LONGOperating rangeGreenLong Mode is selectedLOCKOUT state due to Operating range selection setting error
OFFShort Mode is selected
4T or TESTTestYellowExternal Test is being performed
5TOPTop-beam-state (*1)BlueThe top beam is unblockedMUTING/OVERRIDE state, or LOCKOUT state due to Other sensor error
6BTMBottom-beam-state (*1)BlueThe bottom beam is unblockedMUTING/OVERRIDE state, or LOCKOUT state due to DIP Switch setting error (*2)

*1. The indicator of the emitter is illuminated only in the case the Wired Synchronization is enabled and is off in the case the Optical Synchronization is enabled.

*2. DIP switches are on the Intelligent Tap.

LED Indicators of the Receiver

LocationIndicatorNameColorIlluminatedBlinking
1C or CODEScan codeGreenCode A is selected
OFFAutomatic interference prevention by wired synchronization being performed
2E or ERRLockoutRedLOCKOUT state. The indicator is illuminated in the receiver of another sensor segment than that having a lockout error (when in cascade connection or between the emitter and receiver in the Wired Synchronization)LOCKOUT state. The indicator is illuminated in the receiver of a sensor segment having a lockout error
3O or OSSDON/OFFGreenSafety outputs are in ON stateLOCKOUT state due to Safety Output error, or error due to abnormal power supply or noise
RedSafety outputs are in OFF stateLOCKOUT state due to a replacement-recommended error
4M or MAINTMaintenanceOrangeSafety outputs are instantaneously turned OFF due to ambient light, vibration or noise. Or sequence error in Muting, Pre-Reset or PSDIIntelligent Tap is in the LOCKOUT state
5P or PNPPNP/NPN modeGreenPNP is configuredPolarity of PNP is changed to NPN, or vice versa, during operation, and internal circuit is defective
OFFNPN is configured
6F or CFGConfigurationGreenFixed or Floating Blanking, Reduced Resolution, Warning Zone or Slow mode of Response Time Adjustment is enabled or after the Muting zone is determined by the Dynamic Muting function.TEACH-IN mode, zone measurement being performed by Dynamic Muting, or LOCKOUT state due to Blanking monitoring error, Configuration error or Parameter error
7S or SEQSequenceYellowINTERLOCK stateSequence or sequence error in Muting, Pre-Reset or PSDI (*3) or Teach-in error
8TOPTop-beam-stateBlueThe top beam is unblockedMUTING/OVERRIDE state, or LOCKOUT state due to Other sensor error
9BTMBottom-beam-stateBlueThe bottom beam is unblockedMUTING/OVERRIDE state, or LOCKOUT state due to DIP Switch setting error (*2)

*3. Refer to the F3SG-SR User's Manual for more information on blinking patterns.

Note: In the SETTING state to make settings with the SD Manager 3, the TEST, LONG and CODE indicators on the emitter and the CFG, PNP and CODE indicators on the receiver blink. (TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green)

Reference Manuals

Document TitleCat. No.
Safety Light Curtain F3SG-SR Series Safety Multi-Light Beam F3SG-PG Series User’s ManualZ405-E1
Safety Light Curtain F3SG-SR-K Series Quick Installation Manual2871537-9

In the interest of product improvement, specifications are subject to change without notice.

Suitability for Use

OMRON Companies shall not be responsible for conformity with any standards, codes, or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer's request, OMRON will provide applicable third-party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining the appropriateness of the particular Product with respect to Buyer's application, product, or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Manufacturer and Regional Headquarters

OMRON Corporation (Manufacturer)
Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPAN
Contact: www.ia.omron.com

OMRON EUROPE B.V. (Importer in EU)
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388

OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

F u Apr, 2021

Models: F3SG-SR-K Safety Light Curtain, F3SG-SR-K, Safety Light Curtain, Light Curtain, Curtain

File Info : application/pdf, 2 Pages, 2.64MB

PDF preview unavailable. Download the PDF instead.

f3sg- sr -k inst-2865458-2c ?id=3736 Adobe PDF library 16.04

Related Documents

Preview OMRON Safety Light Curtain F3SG-SR/PG User's Manual
User's Manual for OMRON's F3SG-SR Series Safety Light Curtain and F3SG-PG Series Multi-Beam Safety Sensor. Covers installation, configuration, safety features, and specifications for industrial machine safeguarding.
Preview Omron Industrial Automation Core Product Guide 2021: Integrated Solutions
Explore Omron's Industrial Automation Core Product Guide 2021, featuring sensors, controllers, robotics, vision systems, and safety solutions. Learn about integrated, intelligent, and interactive automation from Omron Automation.
Preview OMRON F39-GWUM PC Tool for F3SJ (SD Manager) Instruction Sheet
Instruction sheet for the OMRON F39-GWUM PC Tool (SD Manager) used with F3SJ safety light curtains. Covers installation, usage, wiring, and troubleshooting.
Preview OMRON NX Series Safety Network Controller: Flexible Production Line Safety
Explore OMRON's NX Series Safety Network Controller for scalable, flexible, and efficient production line safety. Features EtherNet/IP, CIP Safety, EtherCAT, and Sysmac Studio for simplified design and maintenance.
Preview Omron MC-S Series Coded Magnetic Safety Interlock Switches
Detailed information on Omron MC-S Series safety interlock switches, including features, specifications, applications, and ordering information for compact coded magnetic safety interlock switches and control units.
Preview OMRON NE1A-SCPU01 Safety Network Controller - DeviceNet Master/Slave
Discover the OMRON NE1A-SCPU01 Safety Network Controller, a compact programmable safety circuit controller featuring DeviceNet Safety Master and Slave functionality, 16 safety inputs, 8 safety outputs, and IEC/EN61508 (SIL3) certification for industrial automation.
Preview OMRON NE1A-SCPU01-V1 Safety Network Controller Instruction Manual
Comprehensive instruction manual for the OMRON NE1A-SCPU01-V1 Safety Network Controller, covering installation, operation, safety precautions, specifications, and wiring diagrams for optimal performance and compliance.
Preview OMRON OS32C Safety Laser Scanner Quick Reference Guide
Quick reference guide for the OMRON OS32C safety laser scanner, covering safety precautions, installation, wiring, testing, and troubleshooting.