Schneider Electric ABLS1A24021 Optimized Regulated Power Supply
Product Data Sheet
Specifications
Product Name: Regulated Power Supply, 100 to 240V AC, 24V, 2.1A, single phase, Optimized
Model Number: ABLS1A24021
Product Availability: Stock - Normally stocked in distribution facility
Main
Range of Product | Modicon Power Supply |
Product or Component Type | Power supply |
Power supply type | Regulated switch mode |
Variant option | Optimized |
Enclosure Material | Plastic |
Nominal input voltage | 100...240 V AC single phase, 100...240 V AC phase to phase |
Kw Rating | 50 W |
Output voltage | 24 V DC |
Power supply output current | 2.1 A |
Complementary
Efficiency at full load | 85...264 V AC |
Nominal network frequency | 50...60 Hz |
Network system compatibility | TN, TT, IT |
Maximum leakage current | 1 mA 240 V AC |
Input protection type | Integrated fuse (not interchangeable) 3.15 A. External protection (recommended) 20 A Curve C, 10 A Curve B, 6 A Curve C |
Inrush current | 35.0 A 115 V, 75.0 A 230 V |
Power factor | 0.45 at 115 V AC, 0.35 at 230 V AC |
Efficiency | 86% 115 V AC, 88% 230 V AC |
Output voltage adjustment | 24...28 V |
Power dissipation in W | 7.5 W |
Current consumption | < 1.1 A 115 V AC, < 0.65 A 230 V AC |
Turn-on time | < 3 s |
Holding time | > 20 ms 100 V AC, > 100 ms 230 V AC |
Startup with capacitive loads | 3000 μF |
Residual ripple | < 75 mV |
Meantime between failure [MTBF] | 2000000 h at 77 °F (25 °C), full load conforming to SR 332; 900000 h at 131 °F (55 °C), 80% load conforming to SR 332 |
Output protection type | Against overload and short-circuits (automatic reset); Against over temperature (manual reset); Against overvoltage (manual reset) |
Connections - terminals | Screw connection 0.5...2.5 mm², AWG 20...AWG 14) input/output |
Line and load regulation | < 0.5% network 0 to 100% load at 77 °F (25 °C); < 1% network full voltage range in line at 77 °F (25 °C) |
Status LED | 1 LED (Green) output voltage |
Depth | 3.5 in (89.5 mm) |
Height | 3.0 in (75 mm) |
Width | 1.2 in (30 mm) |
Product Weight | 0.397 lb(US) (0.180 kg) |
Output coupling | Parallel, Serial |
Mounting support | Top hat type TH35-15 rail IEC 60715, Top hat type TH35-7.5 rail IEC 60715, Double-profile DIN rail |
Supply | SELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41 |
Dielectric strength | 3000 V AC with input to output |
Service life | 10 year(s) |
Overvoltage category | II |
Environment
Standards | IEC 62368-1, EN/IEC 61204-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4, IEC 61000-3-2, EN 61000-3-3, UL 62368-1, CSA C22.2 No 62368-1, UL 508, CSA C22.2 No. 107.1, EN/IEC 62368-1 |
Product certifications | CE, CUL Listed, CUL Recognized, RCM, CB Scheme, EAC, KC, NEC class 2 |
Operating altitude | < 6561.68 ft (2000 m) |
Shock resistance | 150 m/s² 11 ms |
IP degree of protection | IP20 |
Ambient air temperature for operation | -4...14 °F (-20...-10 °C) with current derating of 2% per °C mounting position A < 6561.68 ft (2000 m); 14...131 °F (-10...55 °C) without derating mounting position A < 6561.68 ft (2000 m); 131...158 °F (55...70 °C) with current derating of 3.33% per °C mounting position A < 6561.68 ft (2000 m) |
Electrical shock protection class | Class I |
Pollution degree | 2 |
Electromagnetic immunity
Vibration resistance | 3 mm (f= 2...9 Hz) conforming to IEC 60068-2-6; 10 m/s² (f= 9...200 Hz) conforming to IEC 60068-2-6 |
Electromagnetic immunity | Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2; Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2; Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3; Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3; Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3; Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4; Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5; Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5; Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6; Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8; Immunity to voltage dips conforming to IEC 61000-4-11 |
Electromagnetic emission | Conducted emissions IEC 61000-6-3; Radiated emissions IEC 61000-6-4; Disturbing field emission conforming to EN 55016-2-3; Limits for harmonic current emissions conforming to IEC 61000-3-2; conforming to EN 55016-1-2; conforming to EN 55016-2-1 |
Ordering and shipping details
Category | US1CP1222525 |
Discount Schedule | CP12 |
GTIN | 3606481500182 |
Returnability | Yes |
Country of origin | PH |
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1 | 1 |
Package 1 Height | 1.50 in (3.800 cm) |
Package 1 Width | 3.39 in (8.600 cm) |
Package 1 Length | 4.29 in (10.900 cm) |
Package 1 Weight | 7.584 oz (215.000 g) |
Unit Type of Package 2: S02
Number of Units in Package 2 | 30 |
Package 2 Height | 5.91 in (15.000 cm) |
Package 2 Width | 11.81 in (30.000 cm) |
Package 2 Length | 15.75 in (40.000 cm) |
Package 2 Weight | 15.382 lb(US) (6.977 kg) |
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via its ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
Environmental footprint
Carbon footprint (kg CO2 eq, Total Life cycle) | 326 |
Environmental Disclosure | Product Environmental Profile |
Materials and Substances
Packaging made with recycled cardboard | No |
Packaging without single use plastic | No |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
SCIP Number | 86cefe39-f12b-4dc7-bf4d-ccd095c653fe |
REACH Regulation | REACH Declaration |
California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Use Again
Repack and remanufacture | Circularity Profile, End of Life Information |
Take-back | No |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Electrical Safety
- If the unit is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
- For means of disconnection a switch or circuit breaker, located near the product, must be included in the installation. A marking as disconnecting device for the product is required.
- The device has an internal fuse. The unit is tested and approved with branch circuit protective device up to 20A. This circuit breaker can be used as disconnecting device.
- The power supply is only suitable for audio, video, information, communication, industrial and control equipment.
Dimensions
Front and Side Views
Diagram Description: Front view showing dimensions: Width 30 mm (1.2 in), Height 75 mm (3.0 in), Depth 92.8 mm (3.7 in). Terminal block details show 3.6 mm (0.1 in) spacing. Side view shows depth 92.8 mm (3.7 in) and height 2.2 mm (0.1 in) for the heatsink fins.
Mounting and Clearance
Mounting Position A
Diagram Description: Shows the power supply mounted vertically on a DIN rail. Clearance required: 15 mm (0.59 in) above and below, 40 mm (1.57 in) to the left (output side), and 15 mm (0.59 in) to the right (input side).
Mounting Position B
Diagram Description: Shows the power supply mounted horizontally on a surface. Clearance required: 20 mm (0.79 in) on the input side, 40 mm (1.57 in) on the output side, and 15 mm (0.59 in) on the top and bottom.
Mounting Position C
Diagram Description: Shows the power supply mounted vertically on a DIN rail, but rotated 90 degrees. Clearance required: 20 mm (0.79 in) on the input side, 40 mm (1.57 in) on the output side, and 15 mm (0.59 in) on the top and bottom.
Incorrect Mounting
Diagram Description: Illustrates incorrect mounting orientations, including upside down, sideways, and with obstructed ventilation, marked with a red cross.
Performance Curves
Performance Curve
Diagram Description: A graph showing the percentage of maximum load (Y-axis) versus surrounding air temperature in °C (X-axis). Curve 1 represents Position A, showing full load capacity up to approximately 45°C. Curve 2 represents Positions B + C, showing reduced load capacity at higher temperatures. Note indicates altitude ≤ 2000 m (6561 ft).
Connections and Schema
Correct Parallel Connection
Diagram Description: Illustrates two ABL1A... power supplies connected in parallel. Input lines L, N, PE are connected to both units. Output lines L1 and L2 are connected from each unit to the load. Condition for correct parallel connection: L1 = L2.
Incorrect Parallel Connection
Diagram Description: Illustrates an incorrect parallel connection where output lines L1 and L2 are not equal. Conditions for correct parallel connection are stated: max 2 x ABLx1Axxxxx, L1 = L2, AV max 25 mV, Load < 90% 2 x Inom.
Output Voltage Balancing
Diagram Description: Shows two power supplies (ABL1A...-1 and ABL1A...-2) with their outputs connected in series. The diagram indicates voltage outputs (Vout1, Vout2) and load connections. Requires 2 x Diodes with specific VRRM and IF ratings. The total output voltage (VLoad) is the sum of Vout1 and Vout2. Conditions for series connection: RLoad1 = RLoad2, I = 2 = ~ Inom.
Ambient Temperature Derating Table
Model | <40°C | <50°C | <70°C |
ABLS1A24021 | 50°C | 60°C | 75°C |
ABLS1A24038 | 50°C | 60°C | 75°C |
ABLS1A12062 | 50°C | 60°C | 80°C |
ABLS1A24031 | 50°C | 60°C | 80°C |
ABLS1A12100 | 60°C | 70°C | 90°C |
ABLS1A24050 | 60°C | 70°C | 90°C |
ABLS1A48025 | 60°C | 70°C | 90°C |
ABLS1A24100 | 60°C | 70°C | 90°C |
ABLS1A24200 | 95°C | 95°C | 90°C |
(1): Ambient
Product Images
Image Description: Top image shows a side view of the ABLS1A24021 power supply, highlighting the heatsink fins and mounting clip. Bottom image shows the front of the power supply with terminal blocks and status LED, along with product labeling.
Alternate Image Description: Top image shows a perspective view of the ABLS1A24021 power supply, emphasizing the side profile and terminal connections. Bottom image shows the front of the power supply with clear labeling of input/output voltages and current, along with the Schneider Electric logo and model number.