Namron Zigbee Thermostat 16A
Model: 16A
Power Supply: 220-240V~ 50Hz
Symbol Overview
- 1. Zigbee Networking icon
- 2. Children Lock ?
- 3. Frost Protection ❄️
- 4. Manual Mode ⚙️
- 5. Program Mode ?
- 6. Period Program
- 7. Temperature/Time ?
- 8. Internal room temperature (°C)
- 9. External room temperature (°C)
- 10. Floor Temperature (°C)
- 11. Regulator mode
- 12. Heating mode ?
- 13. Cooling mode ❄️
- 14. Week Days ?️
- 15. Open Window Detected ?
- 16. ECO mode ?
- 17. Percentage %
- 18. Heating/cooling dynamic icons
- 19. Targeted temperature (°C)
- 20. ON/OFF Button
- 21. Button "M"
- 22. Button "down" ▼
- 23. Button "up" ▲
Installation
The thermostat is applied to full load in areas with the altitude of less than 2500m above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m.
WARNING:
- Installation must be carried out by a qualified electrician.
- Before installation, please check conformity with local electric standards.
- Power supply must be turned off during installation and cleaning.
- Wipe the surface with a soft cloth or tissue; do not use detergents or corrosive chemical solutions.
- Use a standard wall box for proper installation.
- Do not connect L&N or LO&NO reversely.
- Protect the cover during installation to avoid damage.
- When connected to AC230V, the surface cover must be installed. All voltage parts should be considered as 230V.
Wiring Diagram
Refer to the provided wiring diagram for connections. Ensure correct polarity for L&N and LO&NO.
Technical Data
Input | 230VAC+/-10%, 50/60Hz |
Max. Pre-fuse | 16A |
Built-in Switch | 1 Pole, 16A |
Relay contact | Max 16A 250VAC |
Output relay | 16A, SPST-NO |
Floor sensor type / External room sensor | Supports various NTC sensor types (10kΩ, 12kΩ, 15kΩ, 22kΩ, 33kΩ, 47kΩ) with specified resistances and B-values. Default is 3m, NTC, R25=10kΩ±1%@25°C, B25/50=3950K±1%. |
Build-In sensor | NTC, R25=10kΩ±1%@25°C, B25/50=3950K±1% |
Network function | Standard Zigbee 3.0 protocol. |
Wiring Requirements | Current ≤ 13A: 1.5mm² solid core wire, HO7V-R wire. Current > 13A to 16A: 2.5mm² solid core wire, H07V-R wire. |
Control object | Floor Heating |
Method of mounting | Wall mounted |
Control function | Room temperature control, Floor temperature control, External room temperature control, Floor sensor as limit for internal/external room temperature control. Max/min limitation temperatures can be set. |
Control mode | Manual Mode, Weekly Program mode, Regulator |
Frost Protection | Default 5°C to start, 5~10°C controllable. Can be switched ON/OFF manually. |
Ambient temperature | 10°C/+60°C |
External limitation | 5~60°C (Default 27°C) |
Switch deviation | 0.5~10°C adjustable (±1°C) |
Protection level | IP20 |
Material of casing | PC Fire-rated |
Normal Operation Guidance
- Short press ON/OFF button to toggle backlight (ON/OFF).
- Long press ON/OFF button (3s) to turn the Thermostat ON/OFF.
- Short press "M" button to change modes (Manual/Program).
- During heating (not in Regulator P mode), long press "M" (2s) to switch to ECO mode.
- In normal mode (not P mode), short press "▲" or "▼" to adjust the current temperature.
- In Programmed mode, short press "▲" or "▼" to adjust the temporary setpoint temperature for temporary control mode.
- In Regulator P mode, short press "▲" or "▼" to adjust the heating percentage. Short press "M" to confirm.
- From the main screen, long press "M" and "▲" for 3s to enter date/time setting.
- From the main screen, long press "M" and "▼" for 3s to enable/disable child lock.
Advanced Settings
Long press the "M" button for 5 seconds in any control mode to enter advanced settings.
Code | Shown | Meaning of code | Setting Range / Options |
---|---|---|---|
CAr | Air Temperature calibration | Calibrate air temperature reading. | -10~10°C (Factory setting: 0°C) |
CAF | Floor Temperature calibration | Calibrate floor temperature reading. | -10~10°C (Factory setting: 0°C) |
CRE | External room temperature calibration | Calibrate external room temperature reading. | -10~10°C (Factory setting: 0°C) |
Snod | Sensor mode | Select sensor mode. | A: Built-in sensor F: Floor sensor (default) AF: Internal temp control, floor limit A2: External room sensor A2F: External room temp control, floor limit |
SEn | Sensor types | Select floor/external sensor type. | 10K (default), 12K, 15K, 22K, 33K, 47K |
br1 | Display backlight brightness (working status) | Adjust backlight brightness when active. | 10-100%, 10% increments (Factory: 100%) |
br2 | Display backlight brightness (standby status) | Adjust backlight brightness when idle. | 10-100%, 10% increments (Factory: 10%) |
FLE | Floor Limited temp. | Set maximum floor temperature limit. | 5-60°C (Factory setting: 27°C) |
di F | On/Off differential | Adjust temperature differential for ON/OFF switching. | 0.5-10°C (Factory setting: ±1°C) |
Pr6 | Weekly program setting | Configure weekly heating schedule. | Pr6: 5/2 day split (default) Pr62: 6/1 day split Pr63: 7 day continuous Pr64: All days same |
LEP | Frost Protection | Enable/disable frost protection. | OFF (default), 5-10°C |
E6 | Regulator | Set regulator ON/OFF schedule time. | OFF (default), 1-30 min settable heating OFF schedule time. (30 schedules total) |
ADAP | Self-Adjust | Enable/disable self-adaptation function. | OFF (default), ON (Factory default OFF) |
ALO | Lower limit of air sensor temperature | Set minimum air temperature limit. | 0.5~38°C (Factory setting: 5°C) |
AH | Upper limit of Air sensor temperature | Set maximum air temperature limit. | 2.5~40°C (Factory setting: 40°C) |
FLo | Lower limit of Floor sensor temperature | Set minimum floor temperature limit. | 0.5~38°C (Factory setting: 5°C) |
FH | Upper limit of Floor sensor temperature | Set maximum floor temperature limit. | 2.5~40°C (Factory setting: 40°C) |
ELo | Lower limit of external room sensor temperature | Set minimum external room temperature limit. | 0.5~38°C (Factory setting: 5°C) |
EH | Upper limit of external room sensor temperature | Set maximum external room temperature limit. | 2.5~40°C (Factory setting: 40°C) |
EL | Activate Zigbee in-network/off-network mode | Manage Zigbee network connection. | Zigbee Inclusion: Long press "M" (2s) to enter inclusion mode. Check display for status (success/fail). For Homey, double press "M". Zigbee Exclusion: Long press "M" (2s) to enter exclusion mode. Check display for status (success/fail). For Homey, double press "M". |
Nod | Working mode | Select operating mode. | HEAT (default), COOL |
DALE | Date display mode | Set date format. | DDMM (default), MMDD |
FAC | Factory Reset | Reset thermostat to factory defaults. | Long press "M" (5s) in "--" option. |
ESC | Exit advanced settings | Confirm and exit advanced settings. | Short press "M". |
Zigbee Network Management
Inclusion: Ensure the device is not part of any network. Navigate to advanced settings, find the inclusion option, and long press the "M" button for 2 seconds. Simultaneously, set your Zigbee controller to inclusion mode. The display will indicate the inclusion status (e.g., "...", "a..."). A successful inclusion is shown with the Zigbee logo illuminated. "Err" indicates failure. For Homey, double press the "M" button to initiate inclusion.
Exclusion: Navigate to advanced settings, find the exclusion option, and long press the "M" button for 2 seconds. Simultaneously, set your Zigbee controller to exclusion mode. The display will indicate the exclusion status (e.g., "o..."). "ECL" and the Zigbee logo off indicate successful exclusion. "Fer" indicates failure. For Homey, double press the "M" button to initiate exclusion.
Operating Modes
- HEAT: Heating mode (factory default).
- COOL: Cooling mode.
Other Functions
- Open Window Function: Can be enabled (default) or disabled to detect rapid temperature drops indicating an open window.
- Child Lock: Press and hold "M" and "▼" for 3 seconds to enable/disable.