Instruction Manual for namron models including: 4512744, Thermostat Touch Z-Wave 16A

4512744 IM update V2 20210507

NAMRON TERMOSTAT TOUCH Z-WAVE 16A

Manual Mode: the device will control the heating system according to current set temperature. The temperature can be set by move up and move down button on the ...

Schedule setting method 1: user can enters into schedule on Z-Wave Set Interface, the schedule ... ThermostatSetPointType Heating(set manual temperature).


File Info : application/pdf, 13 Pages, 2.11MB

PDF preview unavailable. Download the PDF instead.

4512744-Brukerveiledning-5
INSTRUCTION MANUAL
NAMRON TERMOSTAT TOUCH Z-WAVE 16A

INSTRUCTION MANUAL
Namron termostat touch Z-Wave 16A

81mm

Technical data

81mm

28.4mm 21.3mm

Z-Wave frequency Operation voltage Maximum load Power consumption Ambient temperature Temperature range

868.42MHz (EU) 220-240V, 50/60Hz 16A <2W 0°C to 40°C (during operation) 0°C to 40°C

Hysteresis

0.5°C to 2°C (default 0.5°C)

Floor sensor

NTC R25=10K±1%@25°C, B25/50=3950K±1%, (3m included)

Floor sensors supported NTC R25=10K±1%@25°C, B25/50=3950K±1% (factory setting)
NTC R25=15K±1%@25°C, B25/50=3950K±1% NTC R25=50K±1%@25°C, B25/50=3950K±1% NTC R25=100K±1%@25°C, B25/50=3950K±1%

Control modes

1. Away 2. Auto 3. Manual 4. Drying 5. Off

Control types IP rating Relative humidity Standard
Certificate

Room sensor (factory default) Floor sensor Room + floor sensor This parameter can also be configured through advance config parameter 10
IP21
8% to 80%
EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1 EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019, EN 60730-1:2016+A1:2019, EN 60730-2-19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-1V2.2.3, ETSI EN301 489-3V2.1.1 ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1 RED:2014/53/EU
Z-Wave plus, CE, RED

Installation
a.Installation must be done by a qualified electrician. b.Power supply must be turned off during installation.
(1) Wiring diagram
LN

4512744 SR-ZV9092A

NTC

L LNN

Floor temp sensor
(2) Mounting
a. Remove the display unit and front cover by using a small screwdriver. b. Insert the wires to the correct terminals as presented in the wiring diagram above. Suggested
wire-stripping length is 8-10mm. c. Fix the thermostat into the connection box by tightening the screws. Make sure that the thermostat is
fixed without deformation. Suggested torque is 0.2-0.4Nm (2.0-4.1kgf.cm).

Symbol overview
Off mode Manual mode
Auto mode Drying mode Floor temperature Away mode
Weekdays
Time/shift button
Mode button

Set temperature
C
12:00
MON, TUE, WED, THU, FRI, SAT, SUN
F
Function button

Monitor set Other set Included to a Z-Wave network Schedule Locked means heating forbidden Heating
Time Room temperature
Up and down button

Settings Menu
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow: Enter settings menu (needs to be added) 1. Under Home Interface, meanwhile the device is at OFF mode (Off icon), press and hold up and down buttons at the same time for over 5 seconds to enter Settings Menu. 2. Short press move up and down button to select a settings item, then short press button F to enter selected item. 3. Settings menu include, Preview menu, Z-Wave settings, Schedule, Monitor settings, Time/Date settings, Other settings
Time Setting
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow:
Short press button to select the item you would like to modify, then short press up and
down buttons to modify value of selected item, then short press button F to save and quit,
short pressing button only quits without saving.

2. Preview interface On Home Interface, user can enter into PREVIEW consumption, date, floor temperature etc.

interface, the interface will display some basic configurations, energy

Control Mode
Short press button on Home Interface to switch operation modes: the icons of Away, Auto, Manual, Drying, Off modes
will be displayed alternatively for 3 seconds and last displayed mode will be selected, or just short press F button to select
a desired mode when the modes' icon displayed alternatively. Press and hold button on Home interface for over 3
seconds to select Away mode directly, then Press and hold button for 3 seconds to quit Away mode.

1.Away Mode: the device will control the heating system according to the set temperature within the set period. User can set time to leave home and time to go home according to the requirements of themselves, and set how the device will control the temperature during this period. 1.1. If away mode has already been activated, the end time for away mode is valid, the device will execute Away Mode Temperature Schedule before the end time. 1.2. If away mode has already been activated, the values of end time for away mode are set as 0, the device will always execute current set temperature with no time limitation. The device will consider the mode as anti- freeze mode, the recommended temperature setting is 4-10°C.

2. Auto Mode: the device will control the heating system according to the configured time schedule or Z-Wave protocol Energy_Save_Heating Setpoint. 2.1. When configuration parameter 8 value set as 1, the device will control the temperature of energy save mode according to the temperature set by Command Class Energy_Save_Heating Setpoint or set by using the move up and down buttons, following mentioned schedule will be invalid. 2.2. When configuration parameter 8 value set as 0, the temperature set by Command Class Energy_Save_Heating Setpoint and set by using the move up and move down buttons will both be invalid, Energy Save Mode will control temperature according to following user schedule. For instance, if user would like to keep room temperature at 18C during 18:00-23:00 on every Monday, and keep room temperature at 20C after 22:30 on every Monday, then user can set schedule by himself.

Schedule setting method 1: user can enters into schedule on Z-Wave Set Interface, the schedule interface is as follows:
Short press button to select "Auto Schedule", then short press button F Schedule weekly setting interface.

Schedule setting method 2: on Home Interface, meanwhile the device is under Auto Mode , short press button to enter into Auto Mode Schedule weekly setting interface quickly:
On Auto Mode Schedule weekly setting interface, use buttons and F to enter into schedule setting of a certain week as
follows:
On Auto Day Schedule interface, short press button to select the time or temperature that you would like to modify, then short press move up and down buttons to modify value, then short
press button F to save and quit, short pressing button only quits without saving.
For each schedule, the latter time should be later than the former time, otherwise saving will fail with the error remind "Time setting error!!!". The default time schedules are as follows:

Monday-Friday 7:30,24C-12:00,20C Saturday-Sunday 7:30,24C-12:00,20C

18:00,16C-22:30,18C

18:00,18C-22:30,18C

3. Manual Mode: the device will control the heating system according to current set temperature. The temperature can be set by move up and move down button on the Home interface, or configured by Z-Wave gateway.

4.Drying Mode: The device will judge the set temperature for heating within a short period of time. I.e.: in order to dry the water in the bathroom in a short time, the device could be set to quickly heat to dry the floor. Enter the configuration interface as follow: Duration: set how long the dry mode should lasts After Mode: set the mode after the drying mode ends Remain: shows the remaining time of the drying mode

For configuration method and modification, please refer to Automatic Mode (Energy Save Mode) Schedule:

5.Off Mode: this mode only enables the device to turn on the heating system when anti freezing mode is enabled and the device meets all required conditions, otherwise the device will not work, meanwhile the standby interface will only show room temperature.

Monitor Set
Over-current Alarm
Over-heat Alarm
Hysterersis
Key Vibration Set
Display Brightness Set
Display Temperature Set

The function of monitor set is real time monitor of over current, over heat and freezing. On Home Interface, short press MONITOR SET to enter into monitor set interface a s follows: Short press button to select the item would like to modify, then short press move up and down buttons to modify value of selected
item, then short press F button to save and quit, short pressing
button only quits without saving.
If current is over the set value, the relay will be forced off by the device, and the state will be reported to the gateway. The over current alarm function can be disabled, which can be set directly through the device. Or can be configured through Advance Config parameter 2 by setting the value as 0 to disable the function, please refer to the part "Advance Config".
If room temperature or floor temperature is over the set value, the relay will be forced off by the device, and over heat alarm will be reported to the associated devices, meanwhile the buzzer or vibrator will beep 3 times every 10 seconds. The over heat alarm function can be disabled, which can be set directly through the device. Or can be configured through Advance Config parameter 6 by setting the value as 0 to disable the function, please refer to the part "Advance Config". Over heat alarm interface is as follow: Note: to cancel over current alarm or over heat alarm, just press and hold button for over 3 seconds or reset power of the device. After cancel manually, the relay will show heating forbidden icon within 120 seconds , but other operations are allowed.
To prevent the undulation of sensor temperature when the sensor temperature is approaching the set temperature, which will cause that the controller may keep switching on/off the relay. Here hysterersis enables the controller to control the relay only when the sensor temperature is a bit lower than the set temperature, this value can be set. This hysterersis only valid when the control type is single sensor, please refer to the part Control Type. For instance, when hysterersis is set as 0.5 degree, then only when current sensor temperature is 0.5 degree lower than the set temperature, will the controller heat, if the sensor temperature >= set temperature, the controller will not heat.
Set the level of vibration sensor under the buttons or buzzer level. OFF: vibration or buzzer off Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level. The level can also be configured through Advance Config parameter 03.
The OLED display brightness when operate the device. High Level, Mid Level, Low Level. This parameter can also be configured through Advance Config parameter [22].
This parameter defines which sensor temperature will be displayed on Home page. Floor Temp: floor temperature (external sensor) . Home Temp: indoor air temperature. This parameter can also be configured through Advance Config parameter [23].

Other Set
Temperature Compensation
Re-power Status
Internal Over Heat Protection

Select OTHER SET on Home Interface to enter into OTHER SET interface as follow: Short press button to select the item you would like to modify, then short press move up and down buttons to modify value of
selected item, then short press button F to save and quit, short
pressing button only quits without saving.
The displayed temperature may has big tolerance caused by the sensor or other factors, so it is necessary to do temp compensation to room sensor and floor sensor. Compensation range is -5 ~ +5°C, stepping is 0.5°C. This parameter can a lso be configured through Advance Config parameter [11] and [12] .
Device state after reset power of the device. If set as "last status", device will go to the status before power failure after power on again. If set as "default", device will go to default mode after power on again. This parameter can also be configured through Advance Config parameter [4].
To ensure the safety of the device, if the internal temperature of the device (not displayed on the interface) is over a certain value during heating process, the device will execute a short temporary action to turn off the relay, and the icon will appear on the interface, after the temperature decreases to a certain value, the device will recover to work.

Z-Wave Set Introduction
1 .Z-Wave Network Management Select ZWAVE INFO on Home Interface to enter into Z-Wave network management interface as follow:

Adding to a Z -Wave Network ( Inclusion) Method 1: Select "Add", then short press button , the device will send out inclusion request, "Status" will show "Inclusion...". If there is no response from a gateway within 30 seconds, or inclusion failed, "Status" will show "Fail". If included successfully, "Status" will show "Inclusion OK" and device ID. Method 2: Operate the gateway into inclusion mode, make sure the device is already removed from previous network, reset power of the device, the device will be included to the gateway automatically.

Removing from a Z-Wave Network (Exclusion)
Select "Remove", then short press button F , the device will send out exclusion request, "Status" will show "Exclusion...". If
there is no response from a gateway within 30 seconds, or exclusion failed, "Status" will show "Fail". If excluded successfully,
"Status" will show "Exclusion OK" and device ID will be showed as 0.

Factory Reset (Reset) Factory resetting will reset all Advance Config parameters to default value, and the device will be removed from the Z-Wave network.
Select "Reset", then short press button F , the device will start reset, "Status" will show "Reset...". If there is no response from
a gateway within 6 seconds, or exclusion failed, "Status" will show "Fail". If reset successfully, "Status" will show "Reset OK". Note 1: if the device is excluded or reset successfully, the Auto Mode Schedule will be reset to default value. Note 2: the sent frame of inclusion and exclusion is INFO frame.

2.Basic set command class Set the device operation mode as Comfort Mode (Manual Mode) by sending command class basic set = 0XFF. Set the device operation mode as OFF mode by sending command class basic set = 0x00

Z-Wave Technical Specifications
1.Supported Notification Report and Sensor Type

Notifcation Type

Triggering Event

Description

POWER_MANAGEMENT

POWER_MANAGEMENT_OVERCURRENT_DETECTED Over Current Alarm

Heat Alarm

Overheat detected

Over Heat Alarm

SENSOR MULTILEVEL Type support
Air temperature
2. Technical Specifications Item SDK
Explorer Frame Support Device Type
Generic Device Class Specific Device Class
Role Type Routing

Scale Celsius (¥)
Definition 6.82.00 Yes
Thermostat(HVAC) GENERIC_TYPE_THERMOSTAT SPECIFIC_TYPE_THERMOSTAT_HEATING
Always On Slave (AOS)) Yes

Thermostat Related Specifications

Command

Support

ThermostatMode ThermostatSetPoint

ThermostatMode_OFF(off) ThermostatMode_HEAT(UI displays Manual) ThermostatMode_DRY ThermostatMode_EnergyHeat(UI displays Auto) ThermostatMode_Away(UI displays Away) ThermostatSetPointType_Heating(set manual temperature) ThermostatSetPointType_Energy_Save_Heating(set auto temperature) ThermostatSetPointType_DRY ThermostatSetPointType_Away_Heating(set away temperature)

3. Supported Command Class Root Device
Suppourt Command class COMMAND_CLASS_ZWAVEPLUS_INFO

Support S2/s0 V2

COMMAND_CLASS_SECURITY

V1

COMMAND_CLASS_SECURITY_2

V1

COMMAND_CLASS_TRANSPORT_SERVICE

V2

COMMAND_CLASS_SUPERVISION

V1

COMMAND_CLASS_THERMOSTAT_MODE

V3

YES

COMMAND_CLASS_THERMOSTAT_OPERATING_STATE

V1

YES

COMMAND_CLASS_THERMOSTAT_SETPOINT

V2

YES

COMMAND_CLASS_ASSOCIATION

V2

YES

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION

V3

YES

COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_VERSION

V1

YES

V3

YES

COMMAND_CLASS_MANUFACTURER_SPECIFIC

V2

YES

COMMAND_CLASS_DEVICE_RESET_LOCALLY

V1

YES

COMMAND_CLASS_POWERLEVEL

V1

YES

COMMAND_CLASS_TIME_PARAMETERS

V1

YES

COMMAND_CLASS_CONFIGURATION

V1

YES

COMMAND_CLASS_NOTIFICATION

V8

YES

COMMAND_CLASS_METER

V3

YES

COMMAND_CLASS_MULTI_CHANNEL

V4

YES

COMMAND_CLASS_FIRMWARE_UPDATE_MD

V4

YES

Controlled command class COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_SETPOINT

Support S2/s0

V3

YES

V2

YES

Note: the EndPoint01 mirrors equivalent effect root endpoint. EndPoint1 command list:
Support command class COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION OMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STATE COMMAND_CLASS_THERMOSTAT_SETPOINT
EndPoint2 (floor temperature sensor) command list: Support command class
COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO

Support S2/s0

V2

V1

V1

V1

V5

YES

V2

YES

V3

YES

V1

YES

V3

YES

V1

YES

V2

YES

Support S2/S0

V2

V1

V1

V1

V5

YES

V2

YES

V3

YES

V1

YES

5.Association Root device

Group ID 1

NAME

Profile

Lifeline

AGI_LIFE_LINE c0x0001

Max nodes

Description

1.Send Command Class

DEVICE_RESET_LOCALLY_NOTIFICATION to associated

devices of this group when factory reset the device.

2.Send Command Class

THERMOSTAT_SETPOINT_REPORT,

THERMOSTAT_MODE_REPORT,

5

THERMOSTAT_OPERATING_STATE_REPORT to associated devices of this group When operation mode and

temperature change.

3.Send Command Class NOTIFICATION_REPORT to

associated devices of this group when over current, over

heat detected

4.Send Command Class METER_REPORT to associated

devices of this group to report metering parameters.

AGI_CONTROL_

2

Heat Set

KEY01

5

(0x2001)

Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT_MODE_SET to control other temperature control devices when operation changes

EndPoint01 :

Group ID NAME

Profile Max nodes

1

Lifeline

AGI_LIFE_LINE c0x0001

0

Note: the EndPoint01 has equivalent effect of root function. EndPoint02

Group ID NAME

Profile Max nodes

1

Lifeline

AGI_LIFE_LINE c0x0001

0

Description Lifeline(0x0001)
Description Lifeline(0x0001)

6.Advance Config Parameters

Parameter Size Description

Default Parent Value Menu

0x02(2)

Over current detection max. value, unit is A. When detected current is

over this

1

value, the device will turn off the relay and send NOTIFICATION CC.

0, disable over current detection

5-16, over current detection max. value

16 Monitor Set

0x03(03)

Vibration level and buzzer level triggered by pressing buttons 0, disable

1

vibration and buzzer 1, Low Level

2, High Level

1

Other Set

0x04(4) 0x06(6)

Whether to recover to settings before power failure or power reset

1

0, use default settings

1, recover to settings before power failure or power reset

High temperature detection max. value, unit is ¥ , when either

temperature sensor is higher than this value, the device will turn off the

1

relay and send NOTIFICATION CC.

0, disable this function

20-60, the high temperature value

1

Other Set

45 Monitor Set

0x07(7) 0x08(8)
0x09(9)

1

Temperature control hysteresis value setting, setting range 0.5¥- 2¥ 5-20, unit is 0.1¥

Auto mode (Energy save mode) temperature schedule

1

0, use schedule set by user

1, use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET

Select floor temperature sensor type

1, NTC/10K B(25/50°C)=3950

1

2, NTC/15K B(25/50°C)=3950

3, NTC/50K B(25/50°C)=3950

4, NTC/100K B(25/50°C)=3950

5

Monitor Set

0

None

1

Other Set

0x0A(10) 0x0B(11) 0x0C(12) 0x0D(13) 0x0E(14)
0x10(16)

Temperature control reference selection

1

1, room sensor 2, floor sensor

3, room+floor sensor

1

ROOM SENSOR temperature compensation setting -10~10, unit is 0.5¥

1

FLOOR S ENSOR temperature compensation setting -10~10, unit is 0.5¥

1

Set how long the drying mode lasts 5~100, unit is minute

Set the mode a fter the drying mode ends

0x00 = OFF

1

0x01 = Manual mode (comfort mode)

0x02 = Auto mode (energy save mode)

0x03 = Away mode

When to report temperature relative change threshold value actively, unit

1

is 0.1¥ 0, d isab l e t o r ep or t

2- 10, rep or t when t he threshold v alue i s 2- 10

1

Other Set

0

Other Set

0

Other Set

30

Dry Mode Schedule

2

Dry Mode Schedule

2

None

0x11(17) 0x12(18) 0x13(19) 0x14(20) 0x15(21) 0x16(22)
0x17(23) 0x18(24)

Time interval value for periodic report of temperature, humidity, unit is S

1

0, disable to report

30~28800, report when time interval value is 30~28800

When to report power change absolute threshold, unit is W

1

0, disable to report

1~100, report when absolute threshold is 1~100

300 (5mins)

None

5

None

When to report current change absolute threshold, unit is 0.1A

1

0, disable to report

1~10, report when absolute threshold is 1~10

10

None

When to report voltage change absolute threshold, unit is 1 V

1

0, disable to report

1~10, report when absolute threshold is 1~10

2

None

4

Time interval value for periodic active report of Meter 60-2678400 (31 days) , unit is S

600 (10mins)

None

The OLED display brightness when operate the device.

1

0, low level 1, mid level

2, high level

1

Other Set

This parameter defines which sensor temperature will be displayed on

1

Home page. 0x00: indoor a ir temperature

0x01: external temperature (floor temperature)

The time zone that the time parameters command adopts is UTC, the time

1

zone need to be set:

+12 ~ -12

0

Other Set

0

Other Set

Namron AS Nedre kalbakkvei 88B
1081 Oslo Norway
post@namron.com



References