LUMASCAPE-LOGO

LUMASCAPE sQuad-8 Surface Mounted Luminaire

LUMASCAPE-sQuad-8-Surface-Mounted-Luminaire-PRODUCT

INSTALLATION

  1. Change the beam angle lenses and color filter by removing and replacing existing components (optional). *3/16″ (5 mm) Allen wrench.
  2. Determine the path of the wire; drill a hole if necessary.
  3. Affix the mounting bracket to the surface.
  4. Attach the luminaire to the bracket.
  5. Use voltmeter to ensure 11 to 15 V at luminaire.
  6. Connect wiring with a waterproof connector.LUMASCAPE-sQuad-8-Surface-Mounted-Luminaire-FIG- (1)

CIRCUITING GUIDELINES

LUMASCAPE-sQuad-8-Surface-Mounted-Luminaire-FIG- (2)

TRANSFORMERS

Single transformer:
When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.

Multiple transformers:
When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drops by installing the transformers as close to the luminaires as possible.LUMASCAPE-sQuad-8-Surface-Mounted-Luminaire-FIG- (3)

Please read and keep all safety and use instructions. If you have questions, contact your local agent or visit https://www.lumascape.com.

WARNING

To reduce the risk of FIRE OR INJURY TO a PERSON:

  • Turn off/unplug it and allow it to cool before replacing the lamp.
  • The lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch the hot lens, guard, or enclosure.
  • Keep lamps away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may damage the lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock 

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for the secondary cord that is suitable for wet locations.

LOW-VOLTAGE CABLE SHALL

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low-voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or a fitting.

This product contains a light source of energy efficiency class G.

ARCHITECTURAL & FACADE LIGHTING | Learn more. Visit lumascape.com.