  1. Change the color filter by removing and replacing existing components (optional). *5/64″ (2 mm) Allen key required.
  2. Use level and drill holes for mounting screws.
  3. Fasten housing onto surface.
  4. Use a voltmeter to ensure 11 to 15 V at luminaire.
  5. Connect wiring with a waterproof connector.
  6. Install faceplate over housing. Fasten setscrews.

CIRCUITING GUIDELINESLUMASCAPE-sShell-9-Surface-Mounted-Luminaire-2

TRANSFORMERS

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the luminaires as possible.LUMASCAPE-sShell-9-Surface-Mounted-Luminaire-3

Please read and keep all safety and use instructions. If you have questions, contact your local agent or visit https://www.lumascape.com

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW-VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low-voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or fitting.

This product contains a light source of energy efficiency class G.
Learn more. Visit lumascape.com

Documents / Resources

LUMASCAPE sShell-9 Surface-Mounted Luminaire [pdf] Instruction Manual
sShell-9 Surface-Mounted Luminaire, sShell-9, Surface-Mounted Luminaire, Mounted Luminaire, Luminaire

References

Leave a comment

Your email address will not be published. Required fields are marked *