LOCKWOOD-LOGO

LOCKWOOD FE Series Panic Exit Device with Nightlatch

LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG1

DOOR PREPARATION

  • Determine height of panic exit device:
    For new installations, 900 – 1100mm above FFL is recommended.
  • Using template 1 provided, complete nightlatch door preparation.
  • Axis B should be greater than 50mm from the door frame. Ensure distance A~B is no more than 80mm longer than supplied panic exit device extrusion.
    Drill pilot holes on hinge side of door using Template 2.

    LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG2

PANIC EXIT DEVICE HEAD AND NIGHTLATCH INSTALLATION

  • Determine length of tail bar suitable for install and cut if required. Ensure that tail bar does not protrude by more than 8-10mm from the mounting plate on the other side of the door.
  • Secure the nightlatch assembly and mounting plate with MS countersunk screws provided.
  • Gently tap the plastic adapter with a rubber mallet into the spindle hub of the panic exit head until it sits flush with the hub. Ensure the slot in the adapter is horizontal.
  • Install the panic exit head onto the door with four 04.8 x 25mm pan head screws through the mounting plate.
  • Retract the latch fully to fit the cover on the head. Secure the cover with 2 fixing screws.

    LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG3

HINGE SIDE PLATE FITMENT

  • Install two middle screws through the back plate into pilot holes from template 2.
  • Do not drive the screws fully, leaving a 5mm gap between screw head and plate.

    LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG4

PANIC EXIT DEVICE BAR CUTTING

  • Measure distance A~B, cut panic exit device bar to A~B less 80mm.
  • Ensure cut is square and all debris is removed from the bar.

    LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG5

BAR ASSEMBLY

  • Fit caps onto bar on either side.
  • Secure cap with fixing screw.
  • Install rods into bar, ensuring rod with O-ring fitted is installed in upper hole. Tap gently with a hammer until rods hit a hard stop.

    LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG6

BAR INSTALLATION

  • Fit hinge side mechanism into bar ensuring that the spring is engaged in the square hole and lower rod is fitted into its matching hole.
  • While aligning the front rods into the panic exit head, fit the hinge side mechanism’s keyhole fittings over the screws and push entire mechanism towards the nightlatch.
  • Tighten the screws and test the panic exit device function.
  • Drill two 03 x 25 pilot holes and fit screws to secure the hinge side mechanism.
  • Fit cover and adjust positioning to align cover and mounting plate if necessary. Secure cover with fixing screw.

    LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG7

STRIKE INSTALLATION

  • Please note that this strike installation is for rebated doors only, minimum 22mm thickness. If install doesn’t apply, please refer to original FLUID panic exit
    device instruction sheets.
  • Ensure height of centre of strike is in line with Axis C.
  • Test assembly to ensure that panic exit device releases easily when bar is depressed.

    LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG8

TEMPLATE 1

LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG9

TEMPLATE 2

LOCKWOOD FE Series Panic Exit Device with Nightlatch-FIG10

ASSA ABLOY Australia Pty Limited, 235 Huntingdale Rd, Oakleigh, VIC 3166 ABN 90 086 451 907 ©2021 Experience a safer and more open world