SUNGROW Logger1000A-EU Data Logger
Product Specifications
- Model: Logger1000A-EU
- Wireless LAN (WLAN) Frequency: 2.4GHz/5GHz
- WLAN Transmission Power: 20 dBm for 2.4 GHz, 20 dBm for 5 GHz (5.1~5.7), 14 dBm for 5GHz (5.7~5.8)
- 4G LTE Bands: LTE(FDD) B1,B3,B7,B8,B20,B28A; LTE(TDD) B38,B40
- 4G LTE Frequency Bands: Various ranges for different LTE bands
Product Usage Instructions
Safety Precautions:
Before installation, ensure the package contents are intact and complete against the packing list. Wear proper personal protective equipment (PPE) during operations.
Installation:
Qualified personnel trained in electrical systems should perform all operations. Refer to the user manual and local regulations for detailed instructions.
Wireless LAN (WLAN) Setup:
Configure WLAN settings by accessing the device interface and selecting the appropriate frequency (2.4GHz or 5GHz) based on your network requirements.
4G LTE Connection:
Connect to the available LTE networks by selecting the correct LTE band corresponding to your region’s frequency spectrum.
Validity
This manual is valid for the following data loggers.
Logger1000A-EU
The foregoing Loggers are referred to as the “Logger1000” for short unless otherwise specified.
Safety
- Contents may be periodically updated or revised due to product development. The information in this guide is subject to change without notice. In no case shall this guide substitute for the user manual or related notes on the device.
- Make sure to read over, fully understand and strictly follow the detailed instructions of the user manual and other related regulations. Scan the bottom QR Code of the cover to view or obtain the user manual.
- All operations can be performed only by qualified personnel, that must be trained in the installation and commissioning of the electrical system, as well as the dealing with hazards, have knowledge of the manual and of the local regulations and directives.
- Before installation, check that the package contents are intact and complete against the packing list. Contact SUNGROW or the distributor in case of any damaged or missing components.
- The cable must be intact and well insulated. Operation personnel must wear proper personal protective equipment (PPE) all the time.
- Any violation could result in personal death or injury or device damage, and will void the warranty.
EU Declaration of Conformity within the scope of the EU directives
- Restriction of the use of certain hazardous substances 2011/65/EU and 2015/863/EU (RoHS)
- The radio equipment directive 2014/53/EU (RED)
SUNGROW confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the abovementioned directives. The entire EU Declaration of Conformity can be found at support.sungrowpower.com.
WLAN
Radio technology | WLAN 2.4GHz/5GHz |
Radio spectrum | 2.4GHz 2402 MHz ~ 2484 MHz
5GHz 4900 MHz ~ 5925 MHz |
Maximum transmission power |
2.4GHz ≤ 20 dBm
5GHz(5.1~5.7) ≤ 20 dBm 5GHz(5.7~5.8) ≤ 14 dBm |
4G
Radio technology | LTE(FDD): B1,B3,B7,B8,B20,B28A
LTE(TDD): B38,B40 |
Radio spectrum |
LTE Band 1: 1920 ~ 1980 MHz LTE Band 3: 1710 ~ 1785 MHz
LTE Band 7: 2500 ~ 2570 MHz LTE Band 8: 880 ~ 915 MHz LTE Band 20: 832 ~ 862 MHz LTE Band 28A: 703 ~ 733 MHz LTE Band 38: 2570 ~ 2620 MHz LTE Band 40: 2300 ~ 2400 MHz |
Maximum transmission power | 23±2 dBm |
The technical parameters listed above apply to EU countries only.
Typical Application
NOTICE The Logger1000 can be connected to iSolarCloud via any or a combination of Ethernet, WLAN, and 4 G.
Mechanical Installation
Installation Location
Guide Rail-Mounting
Installing Antenna
Installing Power Box
Electrical Connection
Port Introduction
Tab. 3-1 Port description
Connection to PV Devices
- Connection to a single inverter
The RS485 port of the SUNGROW inverter is an RS485 terminal block or an RJ45 port. - RRS-485terminal block connection
- RJ45 port connection
- Connection to multiple devices
NOTICE
- Multiple inverters are connected to the Logger1000 in the RS-485 daisy chain manner.
- If more than 15 inverters are connected on the RS485 bus, it is recommended to connect a 120Ω terminal resistor in parallel on the RS485A and RS485B lines at the head or tail end of the bus.
- When the number of device types is less than or equal to the number of RS-485 ports of Logger1000, it is recommended to connect different types of devices to different RS-485 ports separately.
Connection to Background
NOTICE
The default IP of the “ETH”:12.12.12.12.
Connection to Micro-SIM
- Micro-SIM card size: 12mm × 15mm.
- Recommended SIM card provider: Telekom, Vodafone, T-Mobile, or O2.
Device Connected | Monthly Data Required |
Inverter | Number of inverters × 25 MB + 25 MB |
Optimizer | Number of optimizers × 0.52 MB + 130 MB |
Meter and meteo station | Number of meters and meteo stations × 12.5 MB + 12.5 MB |
NOTICE
- Ensure that the SIM card has been properly configured for the monthly data plan.
- If using a nano-SIM card with an adapter, ensure that the nano-SIM is properly seated, and is correctly oriented to avoid improper insertion, difficulty in removing the SIM, or potential damage to the device.
- Micro-SIM card hot-plugging is supported.
Connection to Power Box
Connection to Emergency Stop Device
Commissioning
Safety Declaration
- Support for software updates: 2 years
- For details on the product’s network security vulnerability response process and vulnerability disclosure, please scan the QR code on the right or visit the following website:
https://en.sungrowpower.com/security-vulnerability-management
Related documents
- User Manual of the iSolarCloud App
- More information in the QR code or at http://support.sungrowpower.com
Sungrow Power Supply Co., Ltd.
www.sungrowpower.com
Frequently Asked Questions
- Q: Can the Logger1000A-EU be used in non-EU countries?
A: The technical parameters listed are specified for EU countries only. Usage in non-EU countries may require different frequency bands and compliance certifications. - Q: How do I access the user manual for the Logger1000A-EU?
A: Scan the QR Code at the bottom of the device to view or obtain the user manual for detailed instructions on installation and operation.
Documents / Resources
![]() |