DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • Only appropriately trained persons who are familiar with and fully understand the contents of the present manual and all other pertinent product documentation and who have received all necessary training to recognize and avoid hazards involved are authorized to work on and with this equipment.
  • Installation, adjustment, repair, and maintenance must be performed by qualified personnel.
  • Verify compliance with all local and national electrical code requirements as well as all other applicable regulations with respect to grounding of all equipment.
  • Before performing work and/or applying voltage on the equipment, follow the instructions given in the appropriate installation manual.

Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualifed personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this product.
© 2024 Schneider Electric. All Rights Reserved.

Maximum Encoder Cable Length
Encoder Supply Minimum Cable Cross Section Total Encoder Consumption
100 mA 175 mA 200 mA
 

 

12 Vdc

0.2 mm² (AWG 24) 100 m 50 m 50 m
0.5 mm² (AWG 20) 250 m 150 m 100 m
0.75 mm² (AWG 18) 400 m 250 m 200 m
1 mm² (AWG17) 500 m 300 m 250 m
1.5 mm² (AWG15) 500 m 500 m 400 m
 

15 Vdc

0.2 mm² (AWG 24) 250 m 150 m
0.5 mm² (AWG 20) 500 m 400 m
0.75 mm² (AWG 18) 500 m 500 m
24 Vdc 0.2 mm² (AWG 24) 500 m

Schneider-VW3A3424 HTL-Encoder-Interface-Module-1

PIN SIGNAL FUNCTION ELECTRICAL CHARACTERISTICS
1 A+ Channel A Incremental Signal: +12Vdc or +15Vdc or +24Vdc

Input Impedance: 2kΩ Max Frequency: 300kHz Low level: ≤2Vdc

High level: ≥9Vdc

2 A- Channel /A
3 B+ Channel B
4 B- Channel /B
 

5

 

V+

Software configurable encoder supply voltage +12Vdc / 200mA or

+15Vdc / 175mA or

+24Vdc / 100mA

 

6

 

V+

7 0V Reference potential for encoder supply  

8 0V
SHIELD Overall cable shielding for signal lines The shield has to be connected to the drive cabling plate

Encoder can be configured in [Complete settings] → [Encoder configuration].
For more information, refer to the ATV900 Programming Manual (NHA80757).

  PUSH PULL OPEN COLLECTOR  
 

PIN

 

TWISTED WIRE PAIR

 

A/AB/B DIFFERENTIAL

AB SINGLE ENDED A SINGLE-ENDED  

A/AB/B DIFFERENTIAL

 

AB PNP

 

AB NPN

 

A PNP

 

A NPN

 

I/O

1  

1

R R R R R R** R R** I
2 R R* R* R R* R R* R I
3  

2

R R  

R R R** I
4 R R* R R* R I
5 3 R R R R R R R R O
6 Opt. R** R** O
7 3 R R R R R R R R O
8 Opt. R* R* R* R* O
 

SHIELD

 

R

 

R

 

R

 

R

 

R

 

R

 

R

 

R

 

R: Required                *: The inputs have to be wired to the 0V pins

– : Not required           **: The inputs have to be wired to the V+ pins Opt. : Optional

R: Required  *: The inputs have to be wired to the 0V pins
– : Not required  **: The inputs have to be wired to the V+ pins
Opt. : Optional

Schneider-VW3A3424 HTL-Encoder-Interface-Module-2

Schneider-VW3A3424 HTL-Encoder-Interface-Module-3

MANUFACTURER
Schneider Electric Industries SAS
35 rue Joseph Monier
Rueil Malmaison 92500 France

UK REPRESENTATIVE
Schneider Electric Limited
Stafford Park 5
Telford, TF3 3BL United Kingdom

www.se.com

Documents / Resources

Schneider VW3A3424 HTL Encoder Interface Module [pdf] User Guide
VW3A3424 HTL Encoder Interface Module, VW3A3424, HTL Encoder Interface Module, Interface Module, Module

References

Leave a comment

Your email address will not be published. Required fields are marked *