MEAN WELL RD-85 Series Dual Output Switching Power Supply

MEAN-WELL-RD-85-Series-Dual-Output-Switching-Power-Supply-product

Features

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

 GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL RD-85A RD-85B
 

 

 

 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH1 CH2
DC VOLTAGE 5V 12V 5V 24V
RATED CURRENT 8A 4A 8A 2A
CURRENT RANGE Note.3 0 ~ 10A 0 ~ 5A 0 ~ 10A 0 ~ 2.5A
RATED POWER Note.6 88W 88W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 120mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±5.0% ±2.0% ±5.0%
LINE REGULATION                                         Note.4 ±0.5% ±1.0% ±0.5% ±1.0%
LOAD REGULATION Note.5 ±1.0% ±3.0% ±1.0% ±3.0%
SETUP, RISE TIME 500ms, 20ms/230VAC         1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 100ms/230VAC         18ms/115VAC at full load
 

 

 

INPUT

VOLTAGE RANGE 88 ~ 264VAC         125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY(Typ.) 78% 80%
AC CURRENT (Typ.) 2.5A/115VAC         1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

 

PROTECTION

 

OVERLOAD

110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

OVER VOLTAGE

CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)on +5V output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 7)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BIS IS13252(Part1): 2010/IEC 60950-1:2005 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
 

OTHERS

MTBF 2897.3K hrs min.      Telcordia SR-332 (Bellcore) ; 537.9K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 159*97*38mm (L*W*H)
PACKING 0.6Kg; 24pcs/15.4Kg/0.83CUFT
 

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation. (In order to meet tolerance, it is recommended that CH1 load > 10% rated current.)
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. Each output can work within current range. But total output power can’t exceed rated output power.
  7. The power supply is considered a component  which will be installed  into a final equipment.  All the EMC tests are been executed  by mounting  the unit on  a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-RD-85-Series-Dual-Output-Switching-Power-Supply- (1)

Block Diagram

MEAN-WELL-RD-85-Series-Dual-Output-Switching-Power-Supply- (2)

Derating Curve

MEAN-WELL-RD-85-Series-Dual-Output-Switching-Power-Supply- (3)

Static Characteristics

MEAN-WELL-RD-85-Series-Dual-Output-Switching-Power-Supply- (4)

Frequently Asked Questions

  • Q: What should I do if the LED indicator does not light up?
    A: Check the input power source and ensure it is within the specified voltage range. Verify all connections are secure.
  • Q: How can I reset the overload protection feature?
    A: Disconnect the load causing the overload, allow the power supply to cool down, and then reconnect after ensuring the load is within the rated limits.

Documents / Resources

MEAN WELL RD-85 Series Dual Output Switching Power Supply [pdf] Installation Guide
RD-85A, RD-85B, RD-85 Series Dual Output Switching Power Supply, RD-85 Series, Dual Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply