MEAN WELL RD-85 Series Dual Output Switching Power Supply
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105°C long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70°C
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | RD-85A | RD-85B | ||||
OUTPUT |
OUTPUT NUMBER | CH1 | CH2 | CH1 | CH2 | |
DC VOLTAGE | 5V | 12V | 5V | 24V | ||
RATED CURRENT | 8A | 4A | 8A | 2A | ||
CURRENT RANGE | Note.3 | 0 ~ 10A | 0 ~ 5A | 0 ~ 10A | 0 ~ 2.5A | |
RATED POWER | Note.6 | 88W | 88W | |||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 80mVp-p | 120mVp-p | ||
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | ||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±5.0% | ±2.0% | ±5.0% | ||
LINE REGULATION Note.4 | ±0.5% | ±1.0% | ±0.5% | ±1.0% | ||
LOAD REGULATION | Note.5 | ±1.0% | ±3.0% | ±1.0% | ±3.0% | |
SETUP, RISE TIME | 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | |||||
HOLD UP TIME (Typ.) | 100ms/230VAC 18ms/115VAC at full load | |||||
INPUT |
VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
EFFICIENCY(Typ.) | 78% | 80% | ||||
AC CURRENT (Typ.) | 2.5A/115VAC 1.5A/230VAC | |||||
INRUSH CURRENT (Typ.) | COLD START 50A/230VAC | |||||
LEAKAGE CURRENT | <2mA / 240VAC | |||||
PROTECTION |
OVERLOAD |
110 ~ 150% rated output power | ||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE |
CH1: 5.75 ~ 6.75V | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
ENVIRONMENT |
WORKING TEMP. | -25 ~ +70℃ (Refer to “Derating Curve”) | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃)on +5V output | |||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BIS IS13252(Part1): 2010/IEC 60950-1:2005 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | |||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020 | |||||
OTHERS |
MTBF | 2897.3K hrs min. Telcordia SR-332 (Bellcore) ; 537.9K hrs min. MIL-HDBK-217F (25℃) | ||||
DIMENSION | 159*97*38mm (L*W*H) | |||||
PACKING | 0.6Kg; 24pcs/15.4Kg/0.83CUFT | |||||
NOTE |
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
Block Diagram
Derating Curve
Static Characteristics
Frequently Asked Questions
- Q: What should I do if the LED indicator does not light up?
A: Check the input power source and ensure it is within the specified voltage range. Verify all connections are secure. - Q: How can I reset the overload protection feature?
A: Disconnect the load causing the overload, allow the power supply to cool down, and then reconnect after ensuring the load is within the rated limits.
Documents / Resources
![]() |
MEAN WELL RD-85 Series Dual Output Switching Power Supply [pdf] Installation Guide RD-85A, RD-85B, RD-85 Series Dual Output Switching Power Supply, RD-85 Series, Dual Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |