MEAN WELL RD-65A Serie Dual Output Switching Power Supply

MEAN WELL RD-65A Serie Dual Output Switching Power Supply

Features

  • Universal AC input/ Full range
  • Protections: Short circuit/ Overload/ Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70″C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODELRD-65ARD-65B
OUTPUTOUTPUT NUMBERCH1CH2CH1CH2
DC VOLTAGE5V12V5V24V
RATED CURRENT6A3A4A2A
CURRENT RANGE     Note.60-8A0-4A0-8A0- 3A
RATED POWER Note.666W68W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p80mVp-p150mVp-p
VOLTAGE ADJ. RANGECH1: 4.75 – 5.5VCH1: 4.75- 5.5V
VOLTAGE TOLERANCE Note.3±2.0%±6.0%± 2.0%+4,-8%
LINE REGULATION Note.4±0.5%±1.5%±0.5%±2.0%
LOAD REGULATION Note.5±0.5%±3.0%±0.5%±6.0%
SETUP, RISE TIME500ms, 20ms/230VAC         1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)60ms/230VAC         14ms/115VAC at full load
INPUTVOLTAGE RANGE88- 264VAC        125- 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE47- 63Hz
EFFICIENCY(Typ.)78%77%
AC CURRENT (Typ.)2A/115VAC         1.2A/230VAC
INRUSH CURRENT (Typ.)COLD START 50A/230VAC
LEAKAGE CURRENT<2mA/ 240VAC
PROTECTIONOVERLOAD110 – 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGECH1: 5.75- 6.75V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENTWORKING TEMP.-25 – +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40- +85°C, 10-95% RH
TEMP. COEFFICIENT± 0.03%/°C (0 – 50°C )on +5V output
VIBRATION10-500Hz, 5G 10min./1cycle, period for60min. each along X, Y, Z axes
SAFETY & EMC (Note 7)SAFETY STANDARDSUL62368-1, TUV BS EN/EN62368-1 , EAC TP TC 004 approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-0/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25″C/ 70% RH
EMC EMISSIONCompliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITYCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERSMTBF2940.2K hrs min.    Telcordia SR-332 (Bellcore); 541.0K hrs min.     MIL-HDBK-217F (25’C)
DIMENSION129’98’38mm (L’W’H)
PACKING0.44Kg; 30pcs/14.2Kg/0.72CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load> 10%.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. Each output can work within current range. But total output power can’t exceed rated output power.
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm’360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  8. The ambient temperature derating of 3SC/1000m with fanless models and of 5″C/1000m with fan models for operating altitude higher than 2000m(6500ft) Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification

Terminal Pin No. Assignment

Pin No.AssignmentPin No.Assignment
1AC/L4,6DC OUTPUT COM
2AC/N5DC OUTPUT +V2
3FG ½7DC OUTPUT +V1

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Output Derating VS Input Voltage

Output Derating VS Input Voltage

Customer Support

Symbols

QR Code

Arrow.com

MEAN WELL Logo

Documents / Resources

MEAN WELL RD-65A Serie Dual Output Switching Power Supply [pdf] Owner's Manual
RD-65A Serie Dual Output Switching Power Supply, RD-65A Serie, Dual Output Switching Power Supply, Switching Power Supply, Power Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *