LEDlife V1 Single Color LED Contr
Product Information
Model No. | V1 |
---|---|
Features | Single Color LED Controller, 1 Channel/Step-less dimming/Wireless remote control/Auto-transmitting/Synchronize/Push Dim/Multiple protection |
Technical Parameters | Input voltage: 5-36VDC Input current: 8.5A Output voltage: 5-36VDC Output current: 1CH,8A Output power: 40W/96W/192W/288W (5V/12V/24V/36V) Output type: Constant voltage |
Safety and EMC | EMC standard (EMC): ETSI EN 301 489-1 V2.2.3 Safety standard (LVD): ETSI EN 301 489-17 V3.2.4 Radio Equipment (RED) Certification: EN 62368-1:2020+A11:2020 EMC, LVD, RED: ETSI EN 300 328 V2.2.2, CE |
Weight | Net weight: 0.041kg Gross weight: 0.052kg |
Dimming data | Input signal: RF 2.4GHz + Push Dim Control distance: 30m (Barrier-free space) Dimming grayscale: 4096 (2^12) levels Dimming range: 0 – 100% Dimming curve: Logarithmic PWM frequency: 2000Hz (default) |
Environment | Operation temperature: -30°C ~ +55°C Case temperature (Max.): +85°C IP rating: IP20 |
Warranty and Protection | Warranty: 5 years Protection: Reverse polarity, Over-heat, Over-load, Short circuit |
Product Usage Instructions
Mechanical Structures and Installations
LED indicator, Push switch com, Push switch in, Installation rack, Match key, LED output, Power input
Wiring Diagram
Match Remote Control (two match ways)
Option 1: Use the controller’s Match key
- Short press the match key on the controller.
- Immediately press the on/off key (for single zone remote) or zone key (for multiple zone remote) on the remote.
- If the LED indicator flashes a few times, it means the match is successful.
Option 2: Use Power Restart
- Switch off the power of the receiver, then switch on the power.
- Repeat this step.
- Immediately short press the on/off key (for single zone remote) or zone key (for multiple zone remote) 3 times on the remote.
- If the light blinks 3 times, it means the match is successful.
Delete Matched Remotes
- Switch off the power of the receiver, then switch on the power.
- Repeat this step.
- Immediately short press the on/off key (for single zone remote) or zone key (for multiple zone remote) 5 times on the remote.
- If the light blinks 5 times, it means all matched remotes were deleted.
Application notes
All the receivers in the same zone
RF remote control range: 30m
Each receiver (one or more) in a different zone, like zone 1, 2, 3 or 4
RF remote control range: 30m for each zone
Push Dim Function
The provided Push-Dim interface allows for a simple dimming method using commercially available non-latching (momentary) wall switches.
- Short press: Turn on or off the light.
- Long press (1-6s): Press and hold to step-less dimming. With For every other long press, the light level goes in the opposite direction.
- Dimming memory: Light returns to the previous dimming level when switched off and on again, even after a power failure.
- Synchronization: If more than one controller is connected to the same push switch, do a long press for more than 10s to synchronize the system. All lights in the group will dim up to 100%. There is no need for any additional synchrony wire in larger installations. We recommend not exceeding 25 pieces of controllers connected to a push switch, and the maximum length of the wires from push to controller should be no more than 20 meters.
Single Color LED Controller
Channel/Step-less dimming/Wireless remote control/Auto-transmitting/Synchronize/Push Dim/Multiple protection
Features
- 4096 levels 0-100% dimming smoothly without any flash.
- Match with RF 2.4G single zone or multiple zone dimming remote control.
- One RF controller accepts up to 10 remote control.
- Auto-transmitting function: The Controller automatically transmits a signal to another controller with a 30m control distance.
- Synchronize on multiple controllers.
- Connect with external push switch to achieve on/off and 0-100% dimming function.
- Light on/off fade time 3s selectable.
- Over-heat / Over-load / Short circuit protection, recover automatically
Technical Parameters
Input and Output | |
Input voltage | 5-36VDC |
Input current | 8.5A |
Output voltage | 5-36VDC |
Output current | 1CH,8A |
Output power |
40W/96W/192W/288W (5V/12V/24V/36V) |
Output type | Constant voltage |
Safety and EMC | |
EMC standard (EMC) | ETSI EN 301 489-1 V2.2.3
ETSI EN 301 489-17 V3.2.4 |
Safety standard(LVD) | EN 62368-1:2020+A11:2020 |
Radio Equipment(RED) | ETSI EN 300 328 V2.2.2 |
Certification | CE,EMC, LVD,RED |
Weight | |
Net weight | 0.041 kg |
Gross weight | 0.052kg |
Dimming data | |
Input signal | RF 2.4GHz + Push Dim |
Control distance | 30m(Barrier-free space) |
Dimming gray scale | 4096 (2^12) levels |
Dimming range | 0 -100% |
Dimming curve | Logarithmic |
PWM frequency | 2000Hz (default) |
Environment | |
Operation temperature | Ta: -30 OC ~ +55 OC |
Case temperature (Max.) | T c: +85OC |
IP rating | IP20 |
Warranty and Protection | |
Warranty | 5 years |
Protection |
Reverse polarity
Over-heat Over-load Short circuit |
Mechanical Structures and Installations
Wiring Diagram
Match Remote Control (two match ways)
The end user can choose the suitable match/delete ways. Two options are offered for selection
Use the controller’s Match key
Match
- Short press the match key, and immediately press the on/off key (single zone remote) or zone key (multiple zone remote) on the remote.
- The LED indicator fast flashes a few times means the match is successful.
Delete
Press and hold the match key for 5s to delete all matches, The LED indicator fast flashes a few times means all matched remotes were deleted.
Use Power Restart
Match
Switch off the power of the receiver, then switch on the power.
Repeat again
Immediately short press the on/off key (single zone remote) or zone key (multiple zone remote) 3 times on the remote. The light blinks 3 times means the match is successful.
Delete
Switch off the power of the receiver, then switch on the power.
Repeat again
Immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 5 times on the remote. The light blinks 5 times means all matched remotes were deleted.
application note
- . All the receivers in the same zone
Auto-transmitting: One receiver can transmit the signals from the remote to another receiver within 30m, As long as there is a receiver within 30m, the remote control distance can be extended.
Auto-synchronization: Multiple receivers within a 30m distance can work synchronously when they are controlled by the same remote. Receiver placement may offer up to 30m communication distance. Metals and other metal materials will reduce the range. Strong signal sources such as WiFi routers and microwave ovens will affect the range. We recommend for indoor applications that receiver placements should be no further apart than15m Each receiver(one or more) in a different zone, like zone 1, 2, 3 or 4
Push Dim Function
The provided Push-Dim interface allows for a simple dimming method using commercially available non-latching (momentary) wall switches
- Short press
Turn on or off the light. - Long press (1-6s)
Press and hold to step-less dimming With every other long press, the light level goes in the opposite direction. - Dimming memory: Light returns to the previous dimming level when switched off and on again, even at power failure.
- Synchronization: If more than one controller is connected to the same push switch, do a long press for more than 10, then the system is synchronized and all lights in the group dim up to 100%.
- This means there is no need for any additional synchrony wire in larger installations.
- We recommend the number of controllers connected to a push switch does not exceed 25 pieces,
- The maximum length of the wires from push to controller should be no more than 20 meters.
Dimming Curve
Light on/off fade time
Long press match key 5s, then short press match key 3 times, the light on/off time will be set to 3s, and the indicator light blink 3 times. Long press match key 10s, restore factory default parameter, the light on/off time also restore to 0.5s.
Malfunctions Analysis & Troubleshooting
Malfunctions | Causes | Troubleshooting |
No light | 1. No power.
2. Wrong connection or insecure. |
1. Check the power.
2. Check the connection. |
Uneven intensity between front and rear,with voltage drop | 1. Output cable is too long.
2. Wire diameter is too small. 3. Overload beyond power supply capability. 4. Overload beyond controller capability. |
1. Reduce cable or loop supply.
2. Change wider wire. 3. Replace higher power supply. 4. Add power repeater. |
No response from the remote |
1. The battery has no power.
2. Beyond controllable distance. 3. The controller did not match the remote. |
1. Replace battery.
2. Reduce remote distance. 3. Re-match the remote. |
Documents / Resources
![]() |
LEDlife V1 Single Color LED Controller [pdf] Installation Guide V1 Single Color LED Controller, V1, Single Color LED Controller, Color LED Controller, LED Controller, Controller |