ELSEMA MCS Motor Controller Single
Specifications
- Part Number: MCS
- Single gate and door controller for 24 / 12 Volt motor up to 120 Watts
- Supports limit switch inputs or mechanical stops
- Adjustable Auto Close and Pedestrian Access
- Motor soft start and soft stop
- Adjustable lock and courtesy light outputs
- Variable photoelectric safety beam functions
- Large 4-line LCD to indicate controller’s status
- 12 Volt DC Output to power accessories and setup instructions
Product Usage Instructions
Installation
- Before installation, ensure you have read and understood all instructions in the manual.
- Installation should be carried out by trained technical personnel.
- Connect the controller to the appropriate power source as per the wiring diagram provided.
Setup
- Follow the setup instructions provided in the manual to configure the controller for your specific requirements.
- Adjust the settings for Auto Close, Pedestrian Access, motor speed, force, and any other desired features.
Operation
- Use the provided push button or remote control to operate the gate.
- Monitor the LCD display for status updates and alerts.
- If there are any issues, refer to the troubleshooting section of the manual.
FAQ
- Q: What type of batteries are compatible with the MCS controller?
- A: The MCS controller is compatible with Lithium-ion and lead acid batteries.
- Q: Can the MCS controller be used for both swing and sliding gates?
- A: Yes, the MCS controller is suitable for single swing and sliding gates.
- Q: How do I adjust the motor speed and force using the MCS controller?
- A: You can adjust the motor speed and force through the controller’s settings menu. Refer to the manual for detailed instructions.
Important warning and safety instructions
- All installations and testing must be done only after reading and understanding all instructions carefully. All wiring should be done only by trained technical personnel. Failing to follow instructions and the safety warnings may result in serious injury and/or damage to property.
- Elsema Pty Ltd shall not be liable for any injury, damage, cost, expense or any claim whatsoever to any person or property which may result from improper use or installation of this product.
- Risk in the goods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods.
- Any figures or estimates given for performance of goods are based upon the company’s experience and is what the company obtains on tests. The company will not accept liability for failure to comply with the figures or estimates due to the nature of variable conditions affecting for example Radio Remote Controls.
- Please keep this setup instruction for future reference.
Features
- Lithium-ion and lead acid battery charger
- Suitable for single swing and sliding gates
- Single motor operation
- Eclipse Operating System (EOS)
- Motor soft start and soft stop
- Slow speed and force adjustment
- Large 4-line LCD to indicate controllers status and setup instructions
- 1-Touch control for easy setup
- Various inputs, push button, open only, close only, stop, pedestrian and Photoelectric Beam
- Supports limit switch inputs or mechanical stops
- Adjustable Auto Close and Pedestrian Access
- Adjustable lock and courtesy light outputs
- Variable photoelectric safety beam functions
- 12 Volt DC Output to power accessories
- Service counters, password protection, holiday mode and many more features
Description
- The Motor Controller Single (MCS) is more than just the succeeding generation; it’s a revolution in the industry. Our aim was to devise a controller that’s user-friendly and capable of performing virtually every task demanded in the gate and door industry. The MCS represents not merely an advancement but a “Quantum Leap” in the industry, casting an Eclipse over all previously developed motor controllers.This new intelligent motor controller is the best match for your automatic gate or door motors.
- The MCS’s Eclipse® Operating System (EOS) is a user friendly menu driven system that uses the 1-touch button to control, setup and run automatic gates, doors and barriers. It uses a large 4-line LCD screen showing live reading of the motor performance and status of all inputs and outputs.
- The intelligent controller was built from the ground up, based on customer feedback and using todays technology. With its rich functions, consumer friendly price and with the focus during development being ease of use and setup makes this controller the ultimate board to control your motors.
- Elsema’s easy options to add remote controls or any type of Photoelectric Beams makes for a very user friendly approach, while avoiding the lockdown approach to accessories.
Part Number:
Part No. | Contents | Part No. | Contents | |
MCS | Single gate and door controller
for 24 / 12 Volt motor up to 120 Watts |
MCSv2 | Single gate and door controller
for 24 / 12 Volt motor bigger than 120 Watts |
|
For enclosed version see our MC series | ||||
Solar Gates | ||||
Solar24SP | Solar kit for double or single gates, includes solar MPPT charger & 24 Volt 15.0Ah backup battery and a 40 Watt solar panel. | Solar12 | Solar kit for double or single gates, includes solar MPPT charger & 12 Volt 15.0Ah backup battery |
- MCS is suitable for motors up to 120 Watts. Above 120 Watts use MCSv2.
- MCS & MCSv2 control card can be used to control automatic gates, doors, boom gates and automated windows or louvres.
Press Master Control for 2 seconds to enter the menu structure
MCS Connection Diagram
Electrical Wiring – Supply, Motors and Inputs
Always switch off power before doing any wiring.
Make sure that all the wiring is completed and that the motor is connected to the control card. Recommended wire strip length should be 12mm for all connections to the plug in terminal blocks.
The diagram below shows the supply, motors, and inputs available and the factory default setting for each input.
Before Setup
The MCS control card can be installed in a variety of installation setup. Below are 3 common setup. It is very important to select the correct setup type during i-Learn.
- No limit switches.
In this setup, the card relies on the current draw of the motor to determine the fully open and fully closed positions. You need to adjust your margins accordingly to get the gate to fully open and closed. Setting margins too high can cause the motor to stall in the open or closed postion. (See troubleshooting guide). - Limit switches connected to the Control card.
The limit switches can be Normally Closed (NC) or Normally Open (NO). You need to select the correct type during i-Learn. In this setup the limit switches are wired directly to the control card - Limit switches in series with the motor.
The limit switches are connected in series with the motor. The limit switches will disconnect power to the motor when activated.
Setup i-Learning Steps:
- Look at the LCD and follow the instructions displayed.
- The i-Learning setup can always be interrupted with the stop button or by pressing the Master Control knob.
- Enter Menu 11 to start i-Learning or new control cards will automatically prompt you to do the i- Learning.
- The control card will open and close the gate or door several times to learn the load and travel distances. This is the auto profiling using latest intelligent technology.
- Buzzer will indicate learning was successful. If there was no buzzer check all electrical wiring including the power supply then go back to step 1.
- If you hear the buzzer after the i-Learn, the gate or door is ready for use.
Limit Switches
If you are using limit switches make sure they are connected properly. The control card can operate with either the limit switches connected directly to the cards terminal blocks or in series with the motor. See the diagrams below:
By default the limit switch inputs on the control card are normally closed (NC). This can be changed to normally open (NO) during the setup steps.
Optional Accessory
G4000 – GSM Dialer – 4G Gate Opener
The addition of a G4000 module to Eclipse control cards transforms their functionality by enabling mobile phone operation for gates. This integration allows users to remotely open or close the gate with a free phone call. The G4000 enhances convenience, security and efficiency, making it an ideal upgrade for modern access control systems.
See the wiring diagram below:
Connect to Open input on the control card if Open Only function is required
Wiring external device
Elsema Control Card
Connect to Open input on the control card if Open Only function is required
- Auto Close is a feature that automatically closes the gate after a preset time has counted down to zero. The control card has a normal Auto Close and several special Auto Close features each one having its own countdown timers.
- Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used.
- If the Stop input is activated Auto Close is disabled for that cycle only.
- Auto Close timer will not count down if the Push Button, Open or Photoelectric Beam input is held active.
Menu No. | Auto Close Features | Factory Default | Adjustable |
1.1 | Normal Auto Close | Off | 1 – 600 seconds |
1.2 | Auto Close with Photoelectric Trigger | Off | 1 – 60 seconds |
1.3 | Auto Close after an Open Obstruction | Off | 1 – 60 seconds |
1.4 | Auto Close after Power Restored | Off | 1 – 60 seconds |
1.5 | Normal Auto Close on Sequential Obstructions | 2 | Min = Off, Max = 5 |
1.6 | Auto Close Only when Fully Opened | Off | Off/On |
1.7 | Exit |
- Normal Auto Close
The gate will close after this timer has counted down to zero. - Auto Close with Photoelectric Trigger
This Auto Close starts counting down as soon as the Photoelectric Beam has been cleared after a trigger even if the gate is not fully open. If there is no Photoelectric Beam trigger the gate will not Auto Close. - Auto Close after an Open Obstruction
If the gate opens and hits an obstruction normally the gate will stop and remain in this position. If this feature is enabled an obstruction will start the timer count down and at zero will close the gate. - Auto Close after Power Restored
If the gate is open in any position and then there is a power failure, when power is reconnected the gate will close with this timer. - Normal Auto Close on Sequential Obstructions
If the normal Auto Close is set and the gate closes onto an object the gate will stop and reopen. This setting sets the amount of times the gate will try to Auto Close. After trying for the set limit the gate will remain open. - Auto Close Only when Fully Opened
The Auto Close timer will not time out unless the gate is fully open.
There are several types of Pedestrian Access modes. Pedestrian Access opens the gate for a short time to allow someone to walk through the gate but does not allow access to a vehicle.
Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used.
Menu No. | Pedestrian Access Features | Factory Default | Adjustable |
2.1 | Pedestrian Access Travel Time | 3 seconds | 3 – 20 seconds |
2.2 | Pedestrian Access Auto Close Time | Off | 1 – 60 seconds |
2.3 | Pedestrian Access Auto Close Time with PE trigger | Off | 1 – 60 seconds |
2.4 | Pedestrian Access Auto Close on Sequential Obstructions | 2 | Min = Off, Max = 5 |
2.5 | Pedestrian Access with Hold Gate | Off | Off/On |
2.6 | Exit |
- Pedestrian Access Travel Time
This sets the time the gate opens when a Pedestrian Access input is activated. - Pedestrian Access Auto Close Time
This sets the countdown timer for automatically closing the gate when a Pedestrian Access input is activated. - Pedestrian Access Auto Close Time with PE Trigger
This Auto Close starts counting down as soon as the Photoelectric Beam has been cleared after a trigger, when the gate is in the Pedestrian Access position. If there is no Photoelectric Beam trigger the gate will remain in Pedestrian Access position. - Pedestrian Access Auto Close on Sequential Obstructions
If the Pedestrian Access Auto Close is set and the gate closes onto an object the gate will stop and reopen. This setting sets the amount of times the gate will try to Auto Close. After trying for the set limit the gate will remain open. When turned OFF, the gate will always try to Auto Close. - Pedestrian Access with Hold Gate
If the Pedestrian Access hold gate is ON and the Pedestrian Access input is permanently activated the gate will remain open in the Pedestrian Access position. Open input, Close input, Push Button input and remote controls are disable. Used in Fire Exit applications.
This allows you to change the polarity of Photoelectric Beam, Limit Switch and Stop inputs.
Menu No. |
Input Functions | Factory Default | Adjustable |
3.1 | Photoelectric Beam Polarity | Normally Closed | Normally Closed / Normally Open |
3.2 | Limit Switch Polarity | Normally Closed | Normally Closed / Normally Open |
3.3 | Stop Input Polarity | Normally Open | Normally Closed / Normally Open |
3.4 | Exit |
The Photoelectric Beam or sensor is a safety device which is placed across the gate and when the beam is obstructed it stops a moving gate. The operation after the gate stops can be selected in this menu.
Menu No. | Photoelectric Beam Feature | Factory Default | Adjustable |
4.1 | Photoelectric Beam | PE Beam stops and opens gate on close cycle | PE Beam stops and opens gate on close cyclePE Beam stops gate on close cycle————————————PE Beam stops gate on open & close cyclePE Beam stops and closes gate on open cycle |
4.2 | Exit |
- The factory default for the PE beam input is “normally closed” but this can be changed to normally open in Menu 3.1.
- Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used.
- Elsema sells different types of Photoelectric Beams. We stock Retro-Reflective and Through Beam type Photoelectric Beams.
Photo Beam Wiring
- The control card has two outputs, Output 1 and Output 2. The user can change the function of these outputs to lock / brake, courtesy light, service call, strobe (Warning) light or gate open (gate not fully closed) indicator.
- Output 1 is a relay output with common and normally open contacts. Factory default is lock / brake release function.
- Output 2 is an open collector output. Factory default is courtesy light function.
Menu No. | Output Function | Factory Default | Adjustable |
5.1 | Output 1 | Lock / Brake | Lock / BrakeCourtesy Light Service Call————————————Strobe (Warning) LightGate Open Mag Lock |
5.2 | Output 2 | Courtesy Light | Lock / BrakeCourtesy Light Service CallStrobe (Warning) Light Gate Open |
5.3 | Exit |
Lock / Brake Output
The factory default for output 1 is lock/ brake release. Output 1 is a voltage-free relay contact with common and normally open contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC to the common. The normally open contact powers the device. See diagram below:
Courtesy Light
The factory default for the courtesy light is on output 2. Output 2 is an open collector output. This output is used to switch an external relay such as Elsema’s REL12-1 which can be purchased separately. See diagram on the next page.
Service Call Output
Either output 1 or output 2 can be changed to service call indicator. This will trigger the output when the software service counter is reached. Used to alert installers or owners when the gate is to be serviced. Using Elsema’s GSM receiver allows installers or owners to get a SMS message and a call when the service is due.
Strobe (Warning) Light when Opening or Closing
The relay output is activated whenever the gate is operating. The factory default is Off. Either output 1 or output 2 can be changed to strobe (Warning) light.
Gate Open
The relay output is activated whenever the gate is not fully closed. The factory default is Off. Either output 1 or output 2 can be changed to gate open.
Menu 6.1 – Lock / Brake Output Modes
The relay output in the lock / brake mode can be configured in different ways.
Menu No. | Lock / Brake Modes | Factory Default | Adjustable |
6.1.1 | Open Lock / Brake Activation | 2 seconds | 1 – 30 seconds or hold |
6.1.2 | Close Lock / Brake Activation | Off | 1 – 30 seconds or hold |
6.1.3 | Open Pre-Lock / Brake Activation | Off | 1 – 30 seconds |
6.1.4 | Close Pre-Lock / Brake Activation | Off | 1 – 30 seconds |
6.1.5 | Exit |
- Open Lock / Brake Activation
This sets the time the output is activated in the open direction. Factory default is 2 seconds. Setting it to Hold means the output is activated for the total travel time in the open direction. - Close Lock / Brake Activation
This sets the time the output is activated in the close direction. Factory default is off. Setting it to Hold means the output is activated for the total travel time in the close direction. - Open Pre-Lock / Brake Activation
This sets the time the output is activated before the motor starts in the open direction. Factory default is Off. - Close Pre-Lock / Brake Activation
This sets the time the output is activated before the motor starts in the close direction. Factory default is Off.
Menu 6.2 – Courtesy Light Output Mode
The relay output in the courtesy mode can be adjusted from 30 to 300 seconds. This sets the time the courtesy light is activated. Factory default is 60 seconds.
Menu No. | Courtesy Light Mode | Factory Default | Adjustable |
6.2.1 | Courtesy Light Activation | 60 seconds | 30-300 seconds |
6.2.2 | Exit |
Menu 6.3 – Strobe (Warning) Light Output Mode
The relay output in the strobe (Warning) mode can be configured in different ways:
Menu No. | Strobe (Warning) Light Mode | Factory Default | Adjustable |
6.3.1 | Pre-Open Strobe (Warning) Light Activation | Off | 1 – 30 seconds |
6.3.2 | Pre-Close Strobe (Warning) Light Activation | Off | 1 – 30 seconds |
6.3.3 | Exit |
- Pre-Open Strobe Light Activation
This sets the time the strobe light is activated before the gate operates in the open direction. Factory default is Off. - Pre-Close Strobe Light Activation
This sets the time the strobe light is activated before the gate operates in the close direction. Factory default is Off.
Menu 6.4 – Service Call Output Mode
- This sets the number of complete cycles (Open and Close) required before the built-in buzzer is activated. Also the control card outputs can be configured to be activated if the number of cycles is completed. Connecting Elsema’s GSM receiver to the output allows owners to get a phone call & SMS message when the service is due.
- When “Service Call Due” message shows up on the LCD a service call is required. After service has been done, follow the messages on the LCD.
Menu No. | Service Call Mode | Factory Default | Adjustable |
6.4.1 | Service Counter | Off | Min: 2000 to Max: 50,000 |
6.4.2 | Exit |
The control card has many special features that can all be customised to your specific application.
Menu No. | Special Features | Factory Default | Adjustable |
7.1 | Remote Control Open Only | Off | Off / On |
7.2 | Holiday Mode | Off | Off / On |
7.3 | Energy Saving Mode | Off | Off / On |
7.4 | Automatic Stop & Open on Closing | On | Off / On |
7.5 | Receiver Channel 2 Options | Off | Off / Light / Pedestrian Access / Close Only |
7.6 | Press and Hold for Open Input | Off | Off / On |
7.7 | Press and Hold for Close Input | Off | Off / On |
7.8 | Window / Louvre | Off | Off / On |
7.9 | Reserved | Reserved | Reserved |
7.10 | Press & Hold Remote Channel 1 (Open) | Off | Off / On |
7.11 | Press & Hold Remote Channel 2 (Close) | Off | Off / On |
7.12 | Stop Input | Stop the Gate | Stop and reverse for 1sec |
7.13 | Exit |
- Remote Control Open Only
By default the remote control allows the user to open and close the gate. In public access areas user should only be able to open the gate and not worry about closing it. Usually the Auto Close is used to close the gate. This mode disables closing for the remote controls. - Holiday Mode
This feature disables all the remote controls. - Energy Saving Mode
This puts the control card to very low standby current that reduces your electricity bill while still maintaining normal functions and operations. - Automatic Stop & Open on Closing
By default when the gate is closing and a push button or remote control is activated it will automatically stop and open the gate. When this feature is disabled, the gate will only stop. Automatic opening will be disabled. - Receiver Channel 2 Options
The receivers 2nd channel can be programmed to control a courtesy light, pedestrian access or can be used for close only. - Press and Hold for Open and Close Inputs
If this feature is ON the user must continuously press the open or close input for it to be activated. - Window or Louvre Mode
This mode optimises the control card for operating electronic windows or louvres. - Press and Hold for Remote Channel 1 (Open) and Channel 2 (Close)
The remote channel 1 & 2 buttons will need to be programmed to receiver channel 1 & 2. The user must continuously press the remote button for the gate to open or close. The gates will stop as soon as the buttons are released. - Stop Input Options
The stop input can be set to stop the gate or to stop and reverse for 1sec. Default is to stop the gate.
This sets the current sensitivity margin above the normal run current to trip the gate if an obstruction is detected. Different obstruction margins and response time can be set for the open and close direction.
The minimum margin will allow least pressure applied to trip the gate if it hits an object. The maximum margin will allow for a large amount of pressure applied to trip the gate if it hits an object.
Menu No. | Obstruction Detect Margins and Response Time | Factory Default | Adjustable |
8.1 | Open Obstruction Margin | 1 Amp | 0.2 – 6.0 Amps |
8.2 | Close Obstruction Margin | 1 Amp | 0.2 – 6.0 Amps |
8.3 | Open and Close Slow Speed Obstruction Margin | 1 Amp | 0.2 – 6.0 Amps |
8.4 | Obstruction Detect Response Time | Medium | Fast, Medium, Slow and Very Slow |
8.5 | Exit |
Margin Example
- Motor is running at 2 Amps and the margin is set to 1.5 Amps, an obstruction detect will occur at 3.5 Amps (Normal Running Current + Margin).
- For high margin settings, the supply transformer should be large enough to supply the high margin current.
- If the gate hits an object on closing it will automatically stop and then re-open. If the gate hits an object on opening it will automatically stop.
Menu No. | Motor Speed, Slow Speed Area and Reverse Time | Factory Default | Adjustable |
9.1 | Open Speed | 80% | 50% to 125% |
9.2 | Close Speed | 70% | 50% to 125% |
9.3 | Open and Close Slow Speed | 50% | 25% to 65% |
9.4 | Open Slow Speed Area | 4 | 1 to 12 |
9.5 | Close Slow Speed Area | 5 | 1 to 12 |
9.6 | Stop Reverse Delay | 0.4 seconds | 0.2 to 2.5 seconds |
9.7 | Exit |
After changing open speed, close speed or slow speed, i-Learn has to be done again.
- Open and Close Speed
This sets the speed at which the gate will travel. If the gate is travelling too fast reduce this value. - Slow Speed
This sets the speed at which the gate will travel in the slow speed region. If the gate is travelling too slow increase this value. - Slow Speed Area
This sets the slow speed travel area. If you want more travel time for the slow speed area increase this value. - Obstruction Stop Reverse Delay Time
This sets the stop and reverse delay time when the gate hits an obstruction.
Menu No. | Anti-Jam or Electronic Braking | Factory Default | Adjustable |
10.1 | Open Anti-Jam | OFF | 0.1 to 2.0 seconds |
10.2 | Close Anti-Jam | OFF | 0.1 to 2.0 seconds |
10.3 | Electronic Braking | OFF | Off/On |
10.4 | Gate Movement after Obstruction in Opening Direction | Stop | Stop / Reverse for 2 sec / Reverse Fully |
10.5 | Gate Movement after Obstruction in Closing Direction | Reverse for 2 seconds | Stop / Reverse for 2 sec / Reverse Fully |
10.6 | Exit |
- Motor Open and Close Anti-Jam
When the gate are in the fully open or fully closed position this feature applies a reverse voltage for a very short time. It will prevent the motor from jamming up the gate so it is easy to disengage the motors for manual operation. - Electronic Braking
This will stop the motors with an electronic brake. Brake is applied when an obstruction is detected or when the Stop input is triggered. - Opening Direction : Gate Movement after Obstruction
After an obstruction has occurred in the opening direction, the gate will either stop, reverse for 2 seconds or reverse fully. - Closing Direction : Gate Movement after Obstruction
After an obstruction has occurred in the close direction, the gate will either stop, reverse for 2 seconds or reverse fully.
Menu 11 – i-Learning
This feature allows you to do the intelligent travel learning of the gate. Follow the messages on the LCD to complete the learning.
Menu 12 – Password
This will allow the user to enter a password to prevent unauthorised users from entering the control card settings. User must remember the password. The only way to reset a lost password is to send the control card back to Elsema.
To delete a password select Menu 12.2 and press Master Control.
Menu 13 – Operational Records
This is for information only.
Menu No. | Operational Records |
13.1 | Event History, up to 100 events are recorded in the memory |
13.2 | Displays Gate Operations and Currents Levels |
13.3 | Reset Maximum Current Records |
13.4 | Exit |
- Event History
The event history will store 100 events. The following events are recorded into the memory: Power On, Low Battery, All input activations, Successful Opening, Successful Closing, Obstruction Detected, Unsuccessful i-Learning Attempt, Factory Reset, DC Output Overloaded, AC Supply Failed, AC Supply Restored, Auto Close, Security Close and Fuse Protect Obstruction. - Displays Gate Operations and Current Levels
This displays the number of open cycles, close cycles, pedestrian cycles, open obstructions, close obstructions and motor current levels. All maximum current values can be reset by the user from Menu 13.3.
Menu 14 – Tools
Menu No. | Tools |
14.1 | Battery Type : Lithium-ion or Lead Acid battery |
14.2 | Set the Supply Voltage : 12 or 24 Volts |
14.3 | Resets Controller to Factory Settings |
14.4 | Test Inputs |
14.5 | Travel Timer for Slip Clutch Motors |
14.6 | Solar Gate Mode : Optimises the Control Card for Solar Applications |
14.7 | Fuse Type : 10 or 15 Amps
Optimises the Control Card for the correct Blade Fuse used |
14.8 | Slow Speed Ramp Down Time |
14.9 | Magnetic Limit Switch |
14.10 | Exit |
- Battery Type
The MCS can be used with 2 types of backup batteries, Lead Acid & Lithium-ion. Default setting is Lead Acid. Never connect a lithium battery when lead acid mode is selected. Always select the correct battery type. Only use Lithium-ion batteries supplied by Elsema. - Set the Supply Voltage
The control card automatically sets the supply voltage during setup. This option allows you to manually set the control card to 12 or 24 Volt supply. To use the control card in a solar application you must set the correct voltage in the Tools. This will disable the automatic voltage sensing which could causes problems in solar applications. - Resets Controller
Reset all settings to factory default. Also removes password. - Test Inputs
This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means input is activated and lowercase means input is activated. - Travel Timer for Slip Clutch Motors
This allows you to use the controller with travel time. Used for Slip clutch or Hydraulic Motors - Slow Speed Ramp Down Time
This allows you to change the time it takes the gate to change its speed from fast to slow. - Magnetic Limit Switch
Only enable this option when using Elsema’s magnetic Limit Switch.
LCD Display Explained
Gate Status | Description |
Gate Opened | Gate is in the fully open position |
Gate Closed | Gate is in the fully close position |
Gate Stopped | Gate has been stopped by either one of the inputs or remote control |
Obstruction Detected | Control card has sensed an obstruction |
Limit Switch Status | Description |
M1OpnLmON | Motor 1 Open limit switch is ON |
M1ClsLmON | Motor 1 Close limit switch is ON |
Input Status | Description |
Opn ON | Open input is activated |
Cls ON | Close input is activated |
Stp ON | Stop input is activated |
PE ON | Photo Beam input is activated |
PB ON | Push Button input is activated |
PED ON | Pedestrian Access input is activated |
Troubleshooting Guide
During i-Learn, the gate will open and close 3 times. First cycle is in slow speed. The second cycle is in fast speed. The third cycle will be in fast speed but the gate will slow down before reaching the end.
Error during i-Learn | Remedy |
i-Learn is stuck at 14% | Decrease M1 Slow Speed Obstruction Margin (Menu 8.3) |
i-Learn is stuck at 28% | Decrease M1 Open Obstruction Margin (Menu 8.1) |
Gate does not fully open or fully close in the 1st i-Learn cycle | Increase M1 Slow Speed Obstruction Margin (Menu 8.3) |
Gate does not fully open or fully close in the 2nd i-Learn cycle | Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2) |
Limit switch failed to register and the gate is not in the fully open or closed position. | For 1st cycle. Increase M1 Slow Speed Obstruction Margin (Menu 8.3).For 2nd & 3rd cycle. Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2) |
Limit switch failed to register and the gate is in the fully open or closed position. | Limit switch position is not correct. The gate has reached the physical stopper or it’s maximum travel before the limit switch is activated. |
Error during Operation | Remedy |
Gate does not fully open or fully close but the LCD says “Gate Opened” or “Gate Closed”. | Increase M1 Slow Speed Obstruction Margin (Menu 8.3) |
LCD says “Obstruction detected” when there is no obstruction. | Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2) |
Gate does not respond to remotes or any local trigger. | Check the LCD for Input status (see previous page). If any input is activated and held active, the card will not respond to any other command. |
Accessories
Backup Batteries & Battery Charger
The control card has a built in charger for backup batteries. Simply connect the batteries to the battery terminal and the charger will automatically charge the batteries. Elsema has a range of battery sizes.
Solar Applications
Elsema stocks solar gate controller kits, solar panels, solar chargers and full solar gate operators as well.
WARNING
To use the control card in a solar application you must set the correct voltage input in the Tools Menu (16.2). This will disable the automatic voltage sensing which could causes problems in solar applications.
Pre-made Inductive Loops & Loop Detectors
Elsema has a range of Saw-Cut and Direct Burial loops. They are pre-formed with recommended loop sizes for commercial or domestic applications and makes installation quick and easy.
Wireless Bump Strip
Safety edge bump strip is installed on the moving gate or barrier along with the transmitter. When the gate hits an obstacle, the transmitter transmits a wireless signal to the receiver to stop the gate from causing further damage.
Keyring Remotes
The latest PentaFOB® keyring remotes ensure your gates or doors are secure. Visit www.elsema.com for more details.
PentaFOB® Programmer
Add, edit and delete PentaFOB® remotes from the receiver’s memory. The receiver can also be password protected from unauthorised access.
Booster for PentaFOB® remotes
Penta Repeater can increase the operating range of the keyring remotes to up to 500 metres.
Flashing Lights
Elsema has several flashing lights to act as a warning when the gate or doors is in operation.
PentaFOB® Programming Instructions
- Press and hold the program button on the built-in receiver (Refer to the MCS connection diagram)
- Press the remote button for 2 seconds while holding the program button on the receiver
- Receiver LED will flash and then turn Green
- Release the button on the receiver
- Press remote control button to test the receiver output
Deleting Receivers Memory
Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver’s memory.
PentaFOB® Programmer
This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a remote control is lost or a tenant moves from the premises and the owner wants to prevent un-authorised access.
PentaFOB® Backup Chips
This chip is used to backup or restore the contents of a receiver. When there are 100’s of remotes programmed to a receiver the installer normally backups the receiver memory in case the receiver is damaged.