Danfoss logo9

User Guide

TP5001

Programmable Room Thermostat

Danfoss TP5001B-TP5001RF Programmable Room Thermostat

www.danfoss.com

1 LCD Overview

Symbols Function description
Mon – Sun Current set day
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 1 Current on/off period
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 2 Current set time / parameter number in setup
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 3 Room temperature
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 4 Temperature indication
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 5 Set temperature
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 6 Heating active
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 7 Frost protect active
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 8 Schedule mode
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 9 Away mode
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 10 RF Status
(TP5001RF only)
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 11 Battery low indicator
(TP5001B & TP5001RF only)

Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 12

2 Buttons

Symbols Function description
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 13 Power on/off
Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 Timer and program operation
M Mode change / option setting
< > Temperature / option setting selectors
3 Power ON/OFF

Turn the thermostat ON or OFF (standby) by pressing Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 13.

4 Setting the Temperature

  • Press < or > at any time to change the desired temperature value. SET is shown in the display.
  • When releasing < or >, the display returns to showing the actual temperature.
  • The adjustment step is 0.5 °C.
5 Select Away Mode

  • Press M to enter Away mode and Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 9 will be displayed.
  • Away mode temperature can be set in parameter settings, P07.
  • Press M again to exit Away mode.
6 Set Date & Time

  • Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14; Year digit Flashes. Press < or > buttons to adjust year.
  • Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 again; Month digit flashes. Press < or > buttons to adjust month.
  • Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 again; Day digit flashes. Press < or > buttons to adjust day of the month.
  • Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 again; Hour digit flashes. Press < or > buttons to adjust hour.
  • Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 again; Minute digit flashes. Press < or > buttons to adjust minute.
  • Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 to exit, automatic exit after 20 seconds, any changes are retained.
7 Frost Protection Temperature

  • You can switch the thermostat OFF (Standby) by alternately pressing Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 13. In OFF (Standby) mode, the thermostat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls below this temperature (5 °C by default).
  • The frost protect icon and current temperature will be displayed.
8 Advanced Programmable Timer

The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required.

Example below for 5/2 day setup, 4 Temperature settings.

The function consists of 2 programs:
P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)        P2 with 4 events in 2 days (Sat. Sun.).

P1: Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 for 3 secs to display Mo. Tu. We. Th. Fr.

P1, Event 1:

  1. Use < or > to select the start hour.
  2. Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 to accept the setting.
  3. Use < or > to set the minute.
  4. Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 to accept the setting.
  5. Use < or > to select the temperature.
  6. Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 to accept the setting.

P1, Event 2-4:
Repeat the Event 1 procedure for programming Event 2-4.

P2: Sa. Su. are now shown in the display.

P2, Event 1:

  1. Use < or > to select the start hour.
  2. Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 to accept the setting.
  3. Use < or > to set the minute.
  4. Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 to accept the setting.
  5. Use < or > to select the temperature.
  6. Press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14 to accept the setting.

P2, Event 2-4:
Repeat the Event 1 procedure for programming Event 2-4.

If schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be set together with the same times and temperatures.

The thermostat will continue the 4-event program based on the present time and day.

To set and change the room temperature temporarily:

  1. Press < or > at any time to change the desired temperature value. SET is shown in the display.
  2. When releasing the < or >, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting!

A default program provides timer control if the customer does not create own programs:

Days Event 1 Event 2 Event 3 Event 4
Start time Temp. Start time Temp. Start time Temp. Start time Temp.
Mo. – Fr. 6:30 20° C 8:30 15° C 16:30 20° C 22:30 15° C
Sa. – Su. 7:30 20° C 9:30 15° C 16:30 20° C 22:30 15° C

* 24hr mode default program same as Mo. – Fr. above.

9 Set Control Parameters

  • Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set the parameter range via < or >. Complete all adjustments.
  • To exit press Danfoss TP5001B-TP5001RF Programmable Room Thermostat - 14, which is available for this purpose (automatic exit after 20 seconds with no operation).

The digits indicate the set value as follows:

No. Parameter settings Settings range Default
P01 Working mode 01: Manual
02: Schedule timer 5/2 day
03: Schedule timer 24hr
02
P02 Heat control mode 01: On/off load compensation
02: On/off standard
01
P03 Heat control start-up mode 01: Normal start control
02: Delayed start control
03: Optimised start control
01
P04 Temperature limit high Between low (P05) and 35° C 35° C
P05 Temperature limit low Between 5° C and high (P04) 5° C
P06 Frost protect temperature Between 5° C and 15° C 5° C
P07 Away mode temperature Between low (P05) and high (P04) 18° C
P08 Timer display 01: 24hr
02: 12hr
24hr
P09 Service due setup Installer setting only
P10 RF Pairing (TP5001RF only) 00: RF pairing mode off
01: RF pairing mode on
00
P11 Auto daylight saving 01: On
02: Off
01
10 Error Messages

E1 Sensor failure
EE EEPROM failure
Lo Measured temperature below 0 °C
Hi Measured temperature above 50 °C
E3 RF Pairing failed
E4 RF Signal lost
E6 Real Time Clock (RTC) failure

Danfoss Limited UKCA Icon
Climate Solutions • danfoss.uk • 0330 8086 888 • customerservice.uk@danfoss.com
Danfoss Ltd., Building 4, Uxbridge Business Park, Sanderson Road, UB8 1 DH, Uxbridge, Buckinghamshire, UK


Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material.
Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product.
All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.


Danfoss Climate Solutions         BC306936081288EN-010201       03/2023