Solenoid valve

  • Types CSV 2 – CSV 22 (NC)

Refrigerants

  • R22, R134a, R404A, R507, R407C, R513A, R452A, R600, R600a, R1234ze and R290.
  • For other refrigerants, contact Danfoss.

Note: Please follow the specific selection criteria stated in the data sheet for these particular refrigerants.

  • Max. working pressure: PS / MWP: 35 bar /508 psig
  • Max. operation pressure differential (MOPD): Coil dependent
  • Medium temperature: -40 – 105 °C / -40 – 221 °F
  • Ambient temperature: -20 – 55 °C / -4 – 131 °F

Danfoss-CSV-2-CSV-22-Solenoid-Valve-FIG-2

  • For CSV 3 and CSV 6 type valves, Danfoss recommends that a suitable filter or filter drier (max. size of 40 – 50 um) is installed ahead of each solenoid valve to keen scale. solder material and other foreian dirt and particles out of the valve

Mounting angle

Danfoss-CSV-2-CSV-22-Solenoid-Valve-FIG-3

Soldering

Danfoss-CSV-2-CSV-22-Solenoid-Valve-FIG-4

Flare

Danfoss-CSV-2-CSV-22-Solenoid-Valve-FIG-5

Warning

  • Always disconnect power from the coil when dismounted from the valve.
  • The coil may be damaged and there is a risk of injuries and burns.

Danfoss-CSV-2-CSV-22-Solenoid-Valve-FIG-6

  • To ensure correct sealing between the coil and valve, mount the coil in the proper position and make sure that the coil is fully clicked on to the valve.

© Danfoss | DCS (sb) | 2020.10
AN34705422346901-000201 | 1 ugov.ua

Danfoss-CSV-2-CSV-22-Solenoid-Valve-FIG-1

Documents / Resources

Danfoss CSV 2, CSV 22 Solenoid Valve [pdf] Installation Guide
CSV 2, CSV 3, CSV 6, CSV 22, CSV 2 CSV 22 Solenoid Valve, CSV 2 CSV 22, Solenoid Valve, Valve

References

Leave a comment

Your email address will not be published. Required fields are marked *