COMMAND LIGHT logoCOMMAND LIGHT logo1TFB-H5 Flood Lighting Package
User Manual

COMMAND LIGHT TFB-H5 Flood Lighting PackageMODEL COVERED: TFB-H5
3842 Redman Drive
1-800-797-7974
Fort Collins, CO 80524
www.CommandLight.com

TFB-H5 Flood Lighting Package

THANK YOU
Please allow us to express a simple thank you for investing in a COMMAND LIGHT product.
As a company we are dedicated to producing the very best and most versatile flood lighting package available. We take great pride in the quality of our work and hope that you will find many years of satisfaction from the use of this equipment.
Should you have any problems with your product please do not hesitate to contact us.
DELL Command Power Manager Apps - icon 2 DANGER
PERSONAL RESPONSIBILITY CODE
The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following:

  1. Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times.
  2. It is your responsibility to read and understand any user’s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use.
  3. It is your responsibility to know that you have been properly trained in Firefighting and/or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use.
  4. It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use.
  5. It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer’s instructions.
  6. Failure to follow these guidelines may result in death, burns or other severe injury.

COMMAND LIGHT logo2

Fire and Emergency Manufacturers and Services Association, Inc. P.O. Box 147, Lynnfield , MA 01940 www.FEMSA.org
Copyright 2006 FEMSA. All Rights Reserved
Electric Shock Icon WARNING

Read this manual before installing or operating the Shadow™.

LIMITED WARRANTY

Five Year
COMMAND LIGHT warrants that the equipment is free from defects in materials and workmanship when used and operated for a period of five years. The responsibility of COMMAND LIGHT under this limited warranty is limited to the repair and replacement of any parts found defective. Parts must be returned to COMMAND LIGHT at 3842 Redman Drive, Ft Collins, Colorado 80524 with transportation charges prepaid (C.O.D. shipments will not be accepted).
Prior to returning defective parts to COMMAND LIGHT, the original purchaser shall make a claim in writing to COMMAND LIGHT at the above address indicating the model number, serial number and type of defect. No parts or equipment will be received by COMMAND LIGHT for repair or replacement under this warranty without specific written authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of any type or cause are not covered by this warranty.
All equipment manufactured by us is tested before leaving our plant, and is shipped in good working order and condition. We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase:

  1. This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernable when the equipment is returned to us for inspection.
  2. On all component parts not manufactured by COMMAND LIGHT, their warranty is to the extent that the manufacturer of such component warrants them to COMMAND LIGHT, if at all. Look in your local business telephone directory for the nearest repair station for the brand of parts you have or write to us for the address.
  3. If equipment received has been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
  4. Any service other than our Authorized Service voids this warranty.
  5. This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTIBILITY or FITNESS for a particular purpose.
  6. Travel time paid at a maximum of 50% and only if pre-approved.

Breakage or Damage During Shipment
The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it correctly. Please read these instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a description on the freight or express bill describing the damage and the number of pieces. Then contact us and we will send you the original bill of lading. Also promptly contact the transportation company and follow their procedure for filing a claim. Each company will have a unique procedure to follow.
Please note, we cannot and will not enter claims for damages. If we filed claim here, it would be sent to your local freight agent for verification and investigation. This time can be saved by you filing the claim directly. Every consignee is on the ground floor, in contact with the local agent who inspects the damaged goods, and thus, each claim can be given individual attention.
Since our goods are packed to comply with the regulations of all railroad, truck, and express companies, we cannot allow deduction from any invoice because of any damage, however, be sure to file your claim promptly. Our goods are sold F.O.B. factory. We take receipt from the transportation company certifying that the goods were delivered to them in good order and our responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments and in no case will the customer be out any expense if they follow the above instructions.
Be sure to keep all damaged goods subject to examination of the truck or express company inspector, who may call on you some time later. These damaged goods, of course, will belong to them, and they will inform you what to do with them. If you dispose of these damaged goods, your claim may not be paid.
Electric Shock Icon WARNING
Product Safety Precautions 

  •  Never operate the Command Light TFB-H5 near overhead high voltage power lines. The Command Light TFB-H5 is manufactured from electrically conductive materials.
  • Do not use the Command Light TFB-H5 for uses other than its intended purpose.

COMMAND LIGHT TFB-H5 Flood Lighting Package - icon

  • Do not move emergency vehicle with the light extended. Visually verify that the light is completely nested before moving vehicle.
  • Do not change light position while people are located within its operating envelope. There are numerous pinch points that can cause serious bodily injury.
  • Do not use a high-pressure washer or subject the light to high volumes of water when cleaning.
  • Never use the Command Light TFB-H5 as a lifting device or mobile arm.
  • Do not use a Command Light TFB-H5 that has been damaged or is not fully functional, including non-working indicator lamps.
  • Never hold any part of the Command Light TFB-H5 with a hand or foot while it is in motion.
  • The Command Light TFB-H5 has numerous pinch points. Keep loose clothing, hands and feet clear of moving parts.

COMMAND LIGHT TFB-H5 Flood Lighting Package - icon1

Warning CAUTION
General Description and Specifications

The TFB-H5 is designed to provide versatile traffic control with quick precision. As with any electromechanical device, take precautionary steps to ensure safe operation.

Model #  Description  Minimum Power Requirements 
  TFB-H5   8 x LED   16 Amps, 12 VDC

The vehicle provides power for the 12 VDC circuitry. The umbilical corded control unit is powered via 12 VDC eliminating hazardous voltage levels within the hand held control box.
The TFB-H5 is manufactured to provide years of service with a minimum of maintenance.

Operation

Raising the light from the nested position
Using the control box, raise the lift arm. Control switches are of momentary action style and must be held in the “on” position to actuate the stages.
The TFB-H5 has an override system that precludes rotation of the arrow board until the lift arm has elevated approximately 22” from the nested position. When the lift arm is below 22” the following conditions exist:

  •  Arrow board is prevented from rotating.
  • All lights are turned off, including strobe light if equipped, regardless of light switch positions.
  • Prevents the lift arm from moving down if arrow board is not centered.

If the supply from the vehicle is marginal, position the TFB-H5 before turning on lights.
Returning the light to the nested position
The TFB-H5 is equipped with an Aeropark function as a standard feature. Releasing the Aeropark button acts as an “Emergency Stop” and will cancel the Aeropark sequence.
Autopark Sequence
Press and hold the black Aeropark button on the controller. The Aeropark sequence begins:

  1. Arrow board begins rotation to the center position.
  2. Once arrow board is centered, rotation stops, green center indicator illuminates, and lift arm begins retracting.
  3. After lift arm has fully retracted, red nest indicator will be extinguished and LED pods will go out.

Installation

Electric Shock Icon WARNING
The TFB-H5 must be installed by a designated installation facility or by an EVT certified Level FA4 Technician. All safety precautions must be thoroughly understood before
installation. Please consult the factory for additional installation information assistance.
Improper installation can cause overheating of electrical power wires that could catch fire and void the warranty.
Ensure all wiring is properly protected with correct sized breakers and fuses before connecting to the power source.
Verify all connected electrical components are able to handle the load for this light tower as listed in the Technical Specifications on page 15.
If in doubt, contact Command Light at 1-800-797-7974 or info@commandlight.com.
Installation Kit
Included with the TFB-H5 is an installation kit. Verify that the kit contains the following items:
(1) 25 feet of 6 AWG red and black power cable
(1) 25 feet of 22GA-20 conductor cable
(1) Pre-wired HOLSTER BOX w/cover
(1) Handheld Controller
(1) Small hardware parts bag with:
(4) mounting spacers
(4) 5⁄16-18 nylon lock nuts
(4) large diameter flat washers
(4) ¼” flat washers
(3) ½” 90° sealing connector w/nut
(4) 5⁄16-18 X 2 ½” bolts
(8) 5⁄16” flat washers
(2) ¼-20 X 5⁄8” Phillips pan head machine screws
(2) ¼-20 nylon lock nuts
Tools Required

Lifting device (crane, forklift, block and tackle, etc.)
Sling for lifting
Drill
21 ” /64 , ” 17/64 drill bits
Hole punch for metal with ”7/8 and 1 ”5/16 diameter capacity
Phillips head screwdriver, #2
Command Light flat blade screwdriver (included with light)
7/16” ”1/2 and combination wrenches and/or ratchet and ”7/16” 1/2 and sockets 8” adjustable wrench
Tongue and Groove Pliers
Wire stripper or razor blade knife
Solder-less wire connector crimp tool
Silicone based gasket sealer, RTV™ recommended
Installation Notes
Electric Shock Icon WARNING
The TFB-H5 weighs approximately 75 pounds. Use mechanical assistance such as a forklift or crane to lift the light into installation position.
Use the provided fender washers under the mounting surface to distribute the weight load evenly.
When routing the connecting electrical wires take care to avoid sharp bends, hot components or other hazards to the wire.
The TFB-H5 is not designed to be operated in a raised position while the vehicle is in motion. The TFB-H5 includes warning circuit wiring to enable a warning device.
Location Requirements
The standard TFB-H5 can be mounted on any location that is 34” x 22”. The surface should be flat or have only a slight crown. For a recessed installation allow for a minimum of 62” x 44”. Consult with factory before construction of recessed installation. Verify all dimensions before installation to assure proper operation of light will not infringe on other installed components. For all other installations refer to the dimensional drawing included in this guide that represents your particular model of light. The drawings reflect the dimensions of the “working envelope” of a typical light. Endure sufficient clearances are incorporated in your installation to allow for variations (vehicle body flex, environmental conditions, future servicing needs, etc.)

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig1

Four mounting bolts are required. Additional holes may be drilled in the frame ends if necessary to clear obstructions.
Access holes for the power cord cabling should be in close proximity to the entrance box on the light. Installing the cords with a sweeping 90° or 180° bend will provide better results.
The control box holster should be mounted in an area shielded from the weather. Allow a minimum of 10” clearance above the control box holster mounting location for easy access to the controller.
Mounting
Warning CAUTION
Place the provided spacers in the location of the light mounting holes. The spacers may be modified to conform to the contour of the mounting location.
Remove any obstructions below the mounting surface such as headliners.
Attach any necessary lifting attachments to the TFB-H5. The center of gravity (balance point) is slightly below the rotation assembly.
Slowly lift the TFB-H5 and check for balanced lifting. Lower and make any necessary adjustments to the lift points.
Lift and place the TFB-H5 into position above the spacers. Before placing the full weight of the light tower on the spacers, align spacers with the holes in the end frame castings.

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig2Drill 21/64” holes in the mounting surface using the end casting holes as a template.
Fasten the light using the provided hardware. To assure a weather-tight installation apply a thin bead of silicone based gasket sealer to the base of the spacer and underside of bolt head.
Remove any lifting straps and devices from the TFB-H5.
Locate and drill the wire feed holes.
Control Box Holster Mounting
Using the holster as a template, mark locations of holes.
Drill 17/64” mounting holes.
Drill any holes required to route the control wire from the control box to the TFB-H5. Mount holster box with provided hardware.

Electrical Wiring

Please Note: Detailed internal wiring schematic for the light is found in the supplement pages found at the end of this document.
Run the control wire from the control box holster to the TFB-H5.
Run the power wire from the breaker box or generator to the TFB-H5. A 30 Amp breaker is recommended on DC models.
Make the control cable connections in the TFB-H5 relay box by matching each control wire to its same color on the connector block of the TFB-H5 relay box.
The TFB-H5 model comes pre-wired to connect to 12 VDC.
12 VDC 

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig3

Warning Device Installation

The TFB-H5 nest sensor can be used to activate a warning device when the light is extended. Typically the vehicle will have a light or buzzer that activates when the compartment doors are open.
The connector for hooking up a warning device is located in the holster box that holds the control unit.

Maintenance

Cleaning
The TFB-H5 is constructed with corrosion resistant aluminum and stainless steel fasteners.
To further enhance corrosion resistance all exposed surfaces receive a powder coated paint finish. To assure years of trouble free service periodically clean all external surfaces with a mild detergent solution and a gentle spray of water. DO NOT USE A HIGH-PRESSURE WASHER, which will force water into sensitive electric circuitry.
Lamp lenses may be cleaned with any commercially available glass cleaner.
The lift arm actuator is a sealed unit and does not require adjustment or lubrication. They also have a slip-clutch to compensate for minor stroke tolerances at the limits of its travel as well as internal limit switches. The actuator may produce a ratcheting sound at each end of the stroke which is normal. The actuator should not be made to ratchet excessively, this can lead to premature actuator clutch failure.
All pivot points on the TFB-H5 are self-lubricating bronze bushings. Periodic cleaning with a moisture displacing cleaner and soft bristle brush, without disassembly, to remove accumulated dirt and debris will minimize wear.
Power Failure
The TFB-H5 can be retracted manually if power to the unit is lost. If power loss is temporary, reestablishing power may be easier than manually retracting the light.
Disconnect power source from the TFB-H5.
Rotate to Center
Slowly apply pressure to the midplate to manually rotate to the centered position. Trying to rotate the midplate too quickly or with too much pressure can break the rotation motor shaft. Be certain that you rotate the midplate in the proper direction as the Arrow board can rotate only 350˚.
Retract the Lift Arm
Locate the silver plug located on the actuator below the actuator’s motor. Use the provided hex tool (6mm hex bit) to remove silver plug. Be sure to not lose this plug. Use the same hex tool inserted into the opening to drive the internal gears of the actuator. Be sure to replace the silver plug after this actuator is fully retracted.

Troubleshooting

Problem Possible Cause Solution
Unit will not extend No power to the unit Check power input connections. Ensure 30 Amp input breaker has not been tripped.
Incorrect installation Refer to installation instructions.
Upper stage will not rotate Lift arm not raised above 22″ Raise lift arm higher.
Rotation motor failure. Consult with factory.
Lights will not illuminate. Lift arm not raised above 22″ Raise lift arm higher.
Circuit breaker tripped. Check circuit breaker at power supply.
No power to the unit. Check power supply operation/output.
Unit will not nest Arrow board not centered Raise lift arm higher than 22″. Center Arrow board (green light illuminated)
Unit being operated on a slope >10° Level Truck. If problem persists, rotate Arrow board to center, using a pike pole, hold unit centered while lowering to nest position.
No lights or rotation Check safety limit sensor, bad, etc. Contact factory for replacement part.
Autoparking off Center Center switch out of adjustment Contact factory for replacement part.

Technical Specifications – Standard DC Model (TFB-H5, SL400D)
Dimensions (with strobe and ½” mounting spacers) – May vary by model and options:

Height(Depth) Length Width
Retracted   7” 48” 40” Minimums
Extended   52” 70” 40”
Recessed installation   10” 57” 44”

Weight: 75 pounds
Wiring:
Main Power VDC 6 AWG red/black 25’ provided
Control wiring 22/20 PVC Jacketed 25’ provided
Relay protection:
Lights
OptiFuse
3055
30 amps
Current Draw / Power Requirements:

Fixture  Average 
8 x Amber LED 12 VDC/30 amps

Lift actuators and rotation motor will cause higher current draw during use.
Motor Duty Cycle:
(All motors thermally protected, specifications are to thermal relay trip):
Lift arm: 1:3 (90 seconds maximum per 5 minutes)
Rotation: 5-6 Revolutions
Motor Speed:
Lift arm:
0.5 inch per second
14 seconds to full extension
Rotation:
2.75 RPM at lamp tree
Operation:
Angle of vehicle 10˚ maximum incline

Specifications

COMMAND LIGHT TFB-H5 Flood Lighting Package - Diogram

Parts Lists – Exploded Views

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 178-01100 FRAME,WELDMENT,SHADOW RTB
2 1 178-02300 ARM, MAIN LIFT, WELDMENT,SHADOW RTB
3 1 178-01502 PIN,LOWER,PIVOT,SHADOW RTB
4 1 069-15411 ACTUATOR, LINEAR,150MM,12VDC, LA36
5 1 178-01008 ARMITRAILINGILIFT,SHADOW RTB
6 1 178-01501 PIN,LOWER,ACTUATOR,SHADOW RTB
7 1 178-01500 PIN,UPPER,ACTUATOR,SHADOW RTB
8 9 067-14200 BEARING,FLANGED,IGLIDE,JFI-0809-06
9 7 069-15336 E-Ring, 5133-50, .044T, SS
10 2 065-13084 CLAMP,LOOM,#4,SS
11 2 065-12365 CLAMP,LOOM,#6,SS
12 16 069-01140 SCREW,BH,HEX,6x1x16,SS
13 2 069-01126 Nut, MS, M6x1.00
14 1 178-02097 COVER/ACCESS PANEL,LIFT ARM,SHADOW RTB
15 1 065-15001 CANISTER, DOCUM ENT, BLACK
16 1 178-04053 PAD, NEST, SHADOW RTB
17 1 069-01133 SCREW, BH,H EX, M4x0.7×10,SS
18 2 069-01114 SCREW,FHSH,M6x1x16
19 16 034-11028 WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
20 4 069-01103 SCREW,BH,HEX,6x1x12,SS
21 6 034-13092 SCREW, BH, H EX, M4x0.7×8,SS
22 1 178-02099 BRACKET, NEST SWITCH, SHADOW RTB

TFB-H5 Base Assembly

COMMAND LIGHT TFB-H5 Flood Lighting Package - Diogram1

TFB-H5 Midpalate Parts List 

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 178-03002 PLATE, ROTATION DRIVEN, SHADOW RTB
2 1 069-01103 SCREW,SHCS,SHCS M6x1x12
3 4 034-13683 SCREW,SH SET,M6x1.0 x 16mm,SS
4 1 178-03010 BEARING,THRUST,ROTATION,SHADOW RTB
5 1 065-12382 RING,SPIROLOX,2-TURN,WS-175
6 1 178-03001 PLATE, ROTATION DRIVE, SHADOW RTB
7 2 178-03006 STANDOFF,MOTOR,ROTATION,SHADOW RTB
8 1 178-04084 MOUNT,MOTOR,ROTATION,SHADOW RTB
9 4 034-13063 SCREW,SHCS,SHCS M4x0.7×30
10 5 034-13066 SCREW,SHCS,SHCS M4x0.7×10
11 1 178-03005 STOP,ROTATION LIMIT,SHADOW RTB
12 1 034-13064 SCREW,SHCS,SHCS M4x0.7×16
13 2 065-12383 SWITCH,LIMIT,CHERRY,SPDT,5A,125V,SRTBL
14 4 034-03070 SCREW,PHP,2-56 UNCx0.5
15 1 178-03007 LARGE PULLEY,MID PLATE,SRTBL
16 1 178-03009 CAM,ROTATION CENTER,SHADOW RTB
17 1 069-01102 SCREW,BH,HEX,4×0.7×12,SS
18 1 178-04077 SWITCH,LIMIT,MIDPLATE,RTB
19 1 069-01139 SCREW,PPH,M4 X 10
20 2 065-12384 BUSHING,BRONZE,1.753 x 2.004 x 1,SRTBL
21 1 178-03003R3 SPINDLE,ROTATION W/BUSHING,SHADOW RTB
22 1 069-14229 SWITCH,SPDT,5A,250V,ON-MOM,QC
23 4 034-11211 WASHER,FLAT,SAE, #4, SS
24 2 034-11216 SCREW,HH,4-40×3/4,SS
25 2 034-13672 NUT,NYLOCK, 4-40 UNC,SS
26 1 069-01015 MOTOR,TRANSMOTEC,PDS4265-12-864-BF
27 1 065-12378 PULLEY,HTD,P5mm,W15mm,G17,DF,B8mm
28 1 065-12375 BELT,HTD,P5mm,W15mm,G053,SRT BL
29 1 034-13079 PIN,SPRING,5/32 x .75
30 1 034-10936 SCREW,SHS,8-32 UNC x 1/4,SS
31 1 178-03011 MIDPLATE, ROTATION, SHADOW RTB
32 4 034-10947 WASHER,FLAT,SAE, #8, SS
33 4 034-11175 WASHER,LOCK,SPRING,REGULAR, #8, SS
34 4 069-01139 SCREW,SHCS,SHCS M4x0.7×12

TFB-H5 Midplate Assembly
COMMAND LIGHT TFB-H5 Flood Lighting Package - Diogram2

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 076-30045 BACK,LED BOARD,TFBV5
2 8 069-01004 GROMMET,GR-65PT,MARKER LAMP
3 8 069-01003 LAMP,MARKER,LED,PT-Y56A
4 6 069-01140 SCREW, BH,HEX,6x1x16,SS
5 1 178-05004W TREE,TFB,WELDMENT,SHADOW RTB
6 2 178-05005 SUPPORT,TFB, SHADOW RTB
7 1 076-30046 ARRAY,ENCLOSURE,FRONT,TFBV
8 6 034-11028 WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
9 4 034-10961 SCREW,PHP,10-24 UNCx0.375
10 4 034-10981 NUT,NYLOCK, 10-24 UNC,SS
11 2 069-01000 RAIL, DIN, SLOTTED, 7.5MM X 35MM 4 in.
12 4 034-10979 WASHER,LOCK,SPRING,REGULAR, #10, SS
13 2 034-10966 SCREW,PHP,10-24 UNCx0.75
14 2 034-13100 NUT,MS,HEX2,10-24UNC,SS
15 4 065-10075 BRACKET,END,DIN,DN-EB35
16 2 065-10071 BLOCK,TERMINAL,DIN,DN-T10-ORANGE
17 1 065-10072 BLOCK,TERMINAL,DIN,DN-T10-RED
18 1 065-10073 BLOCK,TERMINAL,DIN,DN-T10-WHITE
19 6 069-01103 SCREW,BH,HEX,6x1x12,SS
20 4 069-01107 SCREW,BH,HEX,8×1.25×16,SS
21 2 065-10074 BLOCK,TERMINAL,DIN,DN-T10-YELLOW
22 1 065-10068 BLOCK,TERMINAL,DIN,DN-T10-BLUE
23 1 065-10069 BLOCK,TERMINAL,DIN,DN-T10-BLACK

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig4

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 178-04075W WELDMENT, RELAY BOX EXT., SHADOW RTB
2 1 065-14784 LOOKUP LIGHT,LED, KNIGHT,SHADOW
3 1 065-12854 STRAIN RELIEF,DOMED,SCR .51-.71,3/4 NPT,BLACK
4 3 065-12852 STRAIN RELIEF,DOMED,SCR .24-.47,1/2 NPT,BLACK
5 1 065-12857 LOCKNUT,NYLON,3/4 NPT,BLACK
6 3 065-12856 LOCKNUT,NYLON,1/2 NPT,BLACK
7 1 178-04076 BRIDGE, ELECTRICAL, RELAY BOX, RTB
8 1 069-00995 BREAKER,30 AMP,MANUAL RESET
9 2 065-12828 TERMINAL STRIP,16 POLE
10 6 034-10919 SCREW,PHP,6-32 UNCx0.75
11 6 034-11162 NUT,MS,HEX2,6-32UNC,SS
12 1 079-00005 PLATE,RELAY MOUNT,ALL
13 2 034-10966 SCREW,PHP,10-24 UNCx0.75
14 6 034-10978 WASHER,LOCK,18-8SS,INTERNAL,#10
15 2 034-13100 NUT,MS,HEX2,10-24UNC,SS
16 6 034-10961 SCREW,PHP,10-24 UNCx0.375
17 4 034-10981 NUT,NYLOCK, 10-24 UNC,SS
18 1 065-14187 RELAY SOCKET,3A,14 PIN,SRT BUILDS
19 1 065-14186 RELAY,BL,AUTO PARK,CL,SRT,MY2KDC12
20 2 034-11187 SCREW,FHPMS,6-32 UNC x 3/4 in,SS
21 2 034-13098 NUT,NYLOCK, 6-32 UNC,SS
22 1 065-13529 BREAKER, 12V 20A, SINGLE POLE
23 18 065-13730 SOCKET, SINGLE POLE, RELAY
24 18 065-13738 RELAY, 12V, SINGLE POLE
25 6 034-10939 SCREW,PHP,8-32 UNCx0.5
26 6 034-10951 NUT,NYLOCK, 8-32 UNC,SS
27 1 065-12890 STRIP, BARRIER, 20 POLE
28 4 034-13682 WASHER,LOCK,18-8SS,INTERNAL,#6
29 1 034-13690 SCREW,PHP,1/4-20 UNCx1.25
30 3 034-10110 WASHER,LOCK,18-8SS,INTERNAL,1/4in
31 3 034-11112 NUT,MS,HEX2,1/4-20UNC,SS
32 1 065-12792 STRAIN RELIEF,DOMED,SCR .71-.98,1 NPT,BLACK
33 1 065-12791 LOCKNUT,NYLON,1 NPT,BLACK
34 1 178-04074 COVER,RLY BOX,SHADOW RTB, EXTENDED
35 1 034-11016 SCREW,HH,1/4-20×3/4,SS
36 1 034-11028 WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
37 2 034-10968 SCREW,PHP,10-24 UNCx1
38 1 069-15360 SWITCH, DOWN LIMIT / NEST / BL LIMIT
39 1 065-12935 BOOT,PUSHBUTTON,BLK,BACK LIGHTS
40 3 069-15360 NUT,SWITCH, DOWN LIMIT / NEST / BL LIMIT
41 1 065-10055 RELAY,PROGRAMMABLE,10A,12-24VDC
42 1 065-10056 RELAY,MODULE,5A,12-24VDC

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig5

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig6

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig7

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig8

COMMAND LIGHT TFB-H5 Flood Lighting Package - Fig9

COMMAND LIGHT logoCOMMAND LIGHT_
3842 Redman Drive
Fort Collins, CO 80524
PHONE: 1-800-797-7974
FAX: 1-970-297-7099
WEB: www.CommandLight.com
Effective November 2022
This guide supersedes all previous versions

Documents / Resources

COMMAND LIGHT TFB-H5 Flood Lighting Package [pdf] User Manual
TFB-H5 Flood Lighting Package, TFB-H5, Flood Lighting Package, Lighting Package, Package

References

Leave a comment

Your email address will not be published. Required fields are marked *