TRUFROST and BUTLER logoUSER MANUAL
TWIN TWIST SOFT SERVE MACHINE:
2 Plus 1

Exploded Diagram

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Figure 1

No. Part Name No. Part Name No. Part Name
1 Dispener Door Assembly(figure3) 12 Gear Box 23 Condenser A
2 Dispenser Door Base 13 Driven Pulley 24 Fan A
3 Operation Panel 14 Belt 25 Accesories of Compressor
4 Mix Level Probe 15 Drive Pulley 26 Wheel
5 Hopper 16 Proximity Switch 27 CompressorA
6 Hopper Agitator 17 Evaporator 28 CompressorB
7 Feed Tube 18 Hopper Agitator Motor 29 Front Panel(Lower)
8 Hopper Cover 19 Hopper Thermostat 30 Fan B
9 Gasket of Hopper Over 20 Air Switch Condenser BB
10 Plug of Feed Tube 21 Beater motor 31 Drip tray
11 Coupling 22 Electrical box

Diagram for reference only, please in kind prevail!

Installations& Adjusting

A. unpack & inspect

  1. Cut off the wrapping tape.
  2. Open the wooden case by screwdriver.
  3. Remove the foam.
  4. Inspect carefully whether there is defective appearance or not.
  5. Check the accessories with packing list.
  6. Remove the fixing bolt and fixing feet that are at the bottom of the machine, push the machine, let the front-wheel drive fall to the ground, and then take out the wooden base, let the four wheels grounded. (Directly lift the machine to the ground or on the table if the machine is table type)
    TIPS:When first time using the machine, if there remains liquid residue in the cylinder.It’normal liquid residue caused by ex-factory cleaning and won’t affect machine performance and its service time.If this causes any inconvenience, we feel sorry for that and thank you for your understanding.

B. Installation

  1. SELECTING LOCATION
    a. Place the machine on a level counter that is stable and strong enough to safely support its weight.
    b. Place the machine in a location that allows adequate space at the back and each side for proper ventilation. Keep 50cm space from all sides of ventilation. The machine should shade from the sun and should not be located too close to the units that radiate excessive heat.
    2) POWER SUPPLY
    a. Select the proper power supply according to the voltage and power on the nameplate.
    b. Connect the power wire and the power supply, ensuring the yellow and green wire was connected with the ground wire firmly.

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol Caution: a. For safety, ensure the ground connection is in good condition.
b. All the exterior wires and other appliances must confirm with national standard.

C. Testing Running

  1. Switch “ON” the power switch and you will hear “Beep”,all the graphic patterns on the screen will be lighted up and then the graphic patterns will extinguish,machine enters “Standby” mode.
  2. Press “Wash”, the corresponding indicator will be lighted up and at the same time you will hear the sound of beater system working.Press the “Wash” button again,beater system will stop.
  3. Press “Auto”,the corresponding indicator will be lighted up and the beater system will start working. After 3 seconds,the cooling system will also start working, air pumps in both hoppers enter normal working state.

D. Clearing & Sterilizing
Step 1: Prepare 5-6 liters of warm water, mix with food detergent according to manufacture’s specifications. And this is the sterilizing solution.
Step 2: Pour the solution into the hopper While the solution is flowing into the freezing cylinder, brush and clean the mix hopper.
Step 3: Press the key of “clean”, and let the machine running for about 5 minutes.
Step 4: Place an empty pail beneath the draw spout and push down the draw handle. Draw off all solution.
Step 5: Repeat this operation for 2-3 times with water only.

warning - 1 Notice : a. The temperature of the sterilizing solution can not overpass 60℃, or else it will damage the spare parts.
b. Draw off all the water in the hopper after clearing, or else it will damage the beater while the compressor is running.
c. While press the key of “clean”, pay attention to the indicator light in order to avoid pressing the wrong key.

Operation Instruction

A. Key Instruction

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Figure 2

  1. display screen
  2. adjust key(up)
  3. adjust key(down)
  4. set key
  5. standby key
  6. Wash key
  7. Auto key

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 3 SET KEY(UP / DOWN)
a. set hardness level:
When the machine is ready mode, press “UP” or “DOWN” key for more than 2 seconds then the “SET” word on the displayer flashes and the number shows the setted level of hardness. For example, if the displayer shows “02” it means the current setting level is 2. The stiffness will increase one level each time that the “UP” or “DOWN” key is pushed. It circulate from “01” to “10” ( 01(soft)-02(hard)-03(harder)——-10(hardest)-01(soft))
b. set parameters:
Machine in “standby”mode, press “UP” and “DOWN” at the same time and hold for 5 seconds,the “SET” window displays “P1” icon(Periodic Restarting Time Seeting), Press” TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 1 ”,

the window will display “05”(The variable range is from “5~15” minutes, press”UP” and “DOW” can change the setting volume)
Continue pressing “ TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 1 ” key for two times, every time operation can change the icon display on the window. And when each icon appears,by pressing “ TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 1 ”key for one time to change the setting you want.(Volume can be changed by pressing “UP” and “DOWN”)

Icon Implication Variable Range
P1 Periodic Restarting Time Seeting Range:5~15 minutes
P2 Stop Delay of Beater Motor Range:5~15 seconds
P3 No Specific Meaning Range:5~15 seconds
P4 Hopper     Pre-cooling     Temperature Seeting Range:10—80,indicates 1.0℃ ~8.0℃
P5 Cylinder Temperature Setting
P6 Cleaning Frequency Range:2—14 , indicates 2~14 days
P7 Lack Mix Alarming Time Setting Range:0—10 mins , ”0”- Non- Stop

Press “ TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 1 ” , the machine will enter circulatory volume setting. Without any operation in ten seconds, setting volumes will be automatically saved and back to the standby mode.
Time Setting
In standby mode, press the “AUTO” and “WASH” buttons for 5 seconds, the window shows “F1 01”, then you can click the “UP” or “DOWN” key to adjust the back number.
Press “ TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 1 ” key, the window shows “F2 12”, by such analogy until ” F7 30″.
Note: F1 says mark symbol, 01、02、03……30says actual value.
F1 — week (00 – Sunday) F2 — year F3 – month F4 — date
F5 — hours F6 — minutes F7 — seconds

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 3 WASH KEY
Press wash key “ TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 2 ”, the “CLEAR” icon light and the beater starts to work. It will be closed when you press it again.
TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 3 STANDBY KEY
Press standby key ,“STANDBY”and“FRESH”icon will light. The little compressor for hopper is controlled by setting temperature. It will stop when the temperature is less than the setting value, and it will start again if the tempreature in hopper raise for 2℃. When the temperature in cylinder is less than the setting value, the big compressor stops, after 15 seconds the beater motor stops. When the tempreature in cylinder raise for 2℃, the beater motor start, after 3 seconds the big compressor starts. The temperature of hopper and freezing cylinder can be directly displayed on the screen.
TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 3 AUTO KEY
Press standby key,“AUTO”and“FRESH”icon will light. The little compressor for hopper is controlled by setting temperature. It will stop when the temperature is less than the setting value, and it will start again if the tempreature in hopper raise for 2℃. The big compressor for cylinder will stops when the hardness value reach 99,after 15 seconds the beater motor stops.
The beater motor will starts again when the time goes for setting value(cycle time to restart for machine). After 3 seconds the big compressor starts.
TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 3 PROTECTION FUNCTION 

  • The sensor for freezing cylinder is open circuit or short cirult, hardness window on the screen will show“RL”or“RH”, the buzzer will screams and the machine stop.
  • The sensor for mix hopper is open circuit or short cirult, hardness window on the screen shows “RL”or“RH”, the buzzer screams, and the machine stop.
  • When the machine is in “WASH” or “AUTO” mode, if the digital displayer shows “— —” with alarm and machine stopping,and keys on the operation panel will be locked. That means the proximity switch is damaged or not in correct position. Change it or put it in the correct positoin.
  • When the digital display shows “NL” with alarm and machine stopping, means the belt of beater motor system is skidded.
  • If pushing the handle for more than 1 minute,hardness window on the screen will show“Cb”, the buzzer will screams and the machine stop.
  • Under “AUTO” or “STANDBY” status,if mix lack,hardness window on the screen will show “CL”and hardness alternately,the buzzer will screams for 20 seconds。
  • The number “01” will flash if just 1 day left for the setting cleaning cycle. When the cleaning cycle is over, the window will shows “OVER”, and the buzzer works intermittently. Then you just can use “WASH” and “PUMP” functions. The refrigeration function is locked, and only can be unlocked after switch power off and on again. The cleaning cycle will count anew.
  • Less cooling,no cooling, or cooling over one hour still ice cream not forming, the screen will display”ERR”, and sound of “BEEP” will continue.

B. Make Ice Cream

  1. MAKE SURE THE MACHINE IS CLEAN AND SANITIZED BEFORE  MAKING ICE CREAM.
    a. Prpare some sanitizing solution with warm water(temperature between 50℃ and 60℃),pour it into the hopper and clean the wall of hopper.
    b. Turn on the power switch,and then press “ ” and operate for 5 minitues.
    c. Put an empty pail under the dispensing door,Pull down the handle for 3 seconds,and then return back by hand.Repeat it in this way for 6 times to clean the mix pump assembly thoroughly.
    d. Draw out all sanitizing solution from machine and turn off “ ” .
    e. Take off the 4 screws from dispensing door,then remove the dispensing door assembly.Disassemble it, and put them into the sanitizing solution to clean thoroughly.And then assemble them together and put it on the machine.
    f. Pour some clean water into the hopper and repeat to rinse it for several times.
    g. Use clean towel to wipe water off dispenser door.
  2. PREPARE THE MIXER
    Prepare the ice cream mixer as the instruction of your purchased ice cream powder or liquid mixer.Make sure the liquid mixer without any impurities or particulate. And keep it for 15 minutes or keep it into the freezer.
  3. MAKE ICE CREAM
    Notice : When you select another new ice cream mixer to make ice cream,please set the hardness level to “02”to make ice cream.And adjust the hardness level properly as dispensed ice cream.
    a. Pour half fresh mix into the hopper.
    b. Press “ TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 2 ”,unitl the inlet hole of pump cylinder without bubble.It’s not good for ice cream shape if you don’t operate in this way.
    c. Add more ice cream mixer into the hopper,put the hopper cover on..Press “ TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 4 ” key to start operation.The number on the digital displayer will rise up during operation.When the number reach “99”, the ice cream in the freezing cylinder is ready for serve.
    d. Dispening ice cream.Put a cone or other containern under the dispenser door,pull down the handle to get ice cream.Then push it back after dispensing.
    e. Clean the machine after daily work.Dispensing all the ice cream in the freezing cylinder and mixer in the hopper.Clean and sanitize machine as above instrouction.

Use & Maintenance

Different machines must be used and maintained according to their different using conditions and environment conditions.
A. Washing Refrigeration Cylinders
Clean the refrigeration cylinders once everyday for a longer useful life and for the health of customers.

  1. Press ” TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 2 ” key to exhaust all the remaining slurry in the beverage containers and refrigeration cylinder, then click ” TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 2 ” key ,the machine will stop;
  2. Take the right amount of food detergents, make up disinfecting solution according to it’s instruction with warm water, then put the solution into each bucket;
  3. Press the ” TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Symbol 2 ” key, after the machine stirring about 5 minutes, discharge the disinfecting solution, followed by washing with water 2~3 times, then stop the machine;
  4. Turn off the power, take apart and wash the parts.

a. Unscrew the four fastening screws in front of the dispenser door, remove the dispenser door;
b. Remove the components as follow: pin of handle, handle, piston, O-ring for piston and O-ring for dispenser door from the dispenser door;
c. Draw the beater from the refrigeration tank, then remove the gasket for beater.

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Figure 3

  1. O-ring for dispenser door
  2. supporting sleeve
  3. dispensing door
  4. modeling cap
  5. down bolt
  6. upper bolt
  7. pin for handle
  8. screw for handle
  9. handle
  10. O-ring for piston
  11. piston
  12. middle piston
  13. O-ring for middle piston
  14. beater
  15. gasket for beater

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Figure 3B

  1. piston
  2. O-ring for piston
  3. handle
  4. pin of handle
  5. screw nut (down)
  6. screw nut (up)
  7. Modelling cap
  8. dispensing valve
  9. supporting sleeve
  10. gasket for dispensing valve
  11. flow plug
  12. blade
  13. beater
  14. gasket for beater
  15. New design middle piston O-ring
  16. New design middle piston

d. Put the components into disinfecting solution to clean,check the beater, gasket for beater, O-ring for dispenser door, supporting sleeve and O-ring for piston, if they are worn oldly, they should be replaced;
e. After cleaning, lubricate the parts with vaseline, then install the parts according to the method of taking apart.

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine - Figure 4

Notice : Before installing the piston, O-ring for piston, beater and gasket for beater, you should lubricate vaseline (lubricating vaseline onto the groove of the gasket, do not onto the beater’s end ), using the vaseline frequently can extend the service life of
components.
B. Cleaning Machine Cabinet
Keep the machine cabinet clean, use wet towel to clean the cabinet, and do not flush the machine with water directly.
C. Cleaning Condenser
After be used over a period of time, the condenser maybe thick with dust, and this will effect radiate heat and cause refrigeration difference, so it needs periodic cleaning (every half year)
Cleaning methods:
Step 1: Disconnected the main power switch.
Step 2: Remove the back panel and side panels.
Step 3: Clean dust with tools such as vacuum cleaner, high-pressure air and hairbrush, be careful while cleaning to avoid damaging the fins of the condenser.
D. Belt Adjustment
After be used over a period of time, the belt of the machine maybe elongated, so it needs to be adjusted. Disconnected the main power of the machine, remove the back panel and side panels, adjust the tension bolt and make sure the belt is in appropriate tension.

Trouble shooting guide

Problems Probable cause Remedy
Machine does not run Machine not plugged into the wall receptacle Plug machine in
The short-circuiting switch is open Restart it repositioned after it was
Protect circuit Remove the trouble
Machine position run in clean does  not The connecting wire is unfastened Check and fasten the wire.
The beater motor broke Repair or change the beater motor
Mini circuit breaker was broken. Find and solve the problem then reposition it
Machine position run in auto does  not The wire of function switch is unfastened. Check and fasten the wire.
There is some problem with control panel. Change the control panel.
Compressor does not run Low voltage Solve  the voltage problem of low
Contactor broke change contactor
The relay of the compressor broke Change the control panel.
There is some problem with control panel. Change the control panel.
The self-protection of the compressor  because of overload. Find and solve the problem
The compressor broke Change the compressor
The capacitor of the compressor broke Change the capacitor
Machine do not freeze down Leakage of the refrigerant Find and repair the leak in the pipe, then vacuum and recharge the refrigerant
Electrical valve broke Change the electrical valve
Fan motor do not run Repair or motor change the fan
The capacitor of the fan motor broke Chang the capacitor of fan motor
Machine non-stop The set point is too low Increase the set point
There is some problem with control panel. Change the control panel
Refrigeration difference Check and repair refrigerating system the
The relay stable is not Low voltage Solve voltage the problem of low
There is some problem with control panel. Change the control panel.
The touch point of the contact switch broke. Remove the touch point or change the contact switch.
Product does dispenser not The proportion of mix is incorrect, and causes the refrigeration difference Make up a proper proportion of mix.
No mix in the hopper Pour the mix into the hopper
Limit switch broke or the tie wire is unfastened. Change the switch or fasten the wire
The belt is unfasten or skid around Change or adjust the belt
The bearing sleeve or the beater shaft worn Change the bearing sleeve or the beater shaft.
The product too soft The proportion formula is wrong of the Compound the mix according to the formula given by the supplier.
The set point is too low Increase the set point
Leakage Draw piston leaking Reassemble or change the O- ring.
Dispenser door leaking Tighten the screws or change the D-ring
Drip tube leaking Fix well or change the Gasket for beater
Warm rings Low voltage protection Stop the machine, solve the problem and restart 5 minutes later.
Stop working protection for Stop the machine, solve the problem and restart 5 minutes later.
The limit switch can not return to normal Push down the handle and let the limit switch return to normal.
Nixie tube display “NL” The belt skid or the motor lose speed Adjust or replace the belt, solve the fault of motor
Nixie tube display “——” The proximity switch deflect or broke Adjust or replace proximity switch

Schematic wiring diagram

  • Technology parameters are on the nameplate
  • The electrical schematic diagram is on the board inner

TRUFROST and BUTLER logoMarketed globally by
TRUFROST AND BUTLER PRIVATE LIMITED
1215, 12th Floor, Tower B, Emaar Digital
Greens, Golf Course Extn. Road,
Sector 61, Gurugram – 122011, India
T. + 91-7303166766 info@trufrost.com
www.trufrost.com

Documents / Resources

TRUFROST and BUTLER 2 Plus 1 Twin Twist Soft Serve Machine [pdf] User Manual
2 Plus 1 Twin Twist Soft Serve Machine, 2 Plus 1, Twin Twist Soft Serve Machine, Soft Serve Machine, Serve Machine, Machine

References