SIMcom SIM7022-EVB Cellular Module
User Guide
Table 9: switches and buttons
Number | Name | Description |
SW101 | POWER_KEY | EVB power switch |
SW102 | RESET | Module reset button |
SW103 | WAKEUP | Module wake-up button |
SW1 | DOWNLOAD | Firmware upgrade switch |
![]()
|
Test Points
There are four sets of test points J101, J105, J106, J107 on SIM7022 EVB. The details of the test points are
as follows.
The pin definition of position J101 is shown in the figure below.
Table 10: Test point description of J101 on EVB
Position | |||
J101 | J101_PIN1 | EXT_VBAT | EVB LDO power supply output voltage test point |
J101_PIN2 | VBAT | Module power input voltage test point |
The pin definition of position J105 is shown in the figure below.
Table 11: Pin description of location J105 on EVB
Position | Test point | Signal description | Pin number | Pin name |
J105 | J105_PIN1 | VEXT | 24 | VDD_EXT |
J105_PIN2 | SWD_CLK | 25 | IIC_SDA | |
J105_PIN3 | GND | – | – | |
J105_PIN4 | SWD_DIO | 26 | IIC_SCL | |
J105_PIN5 | ADC | 9 | ADC0 | |
J105_PIN6 | GND | – | – | |
J105_PIN7 | RI | 20 | RI | |
J105_PIN8 | TXD | 18 | UART1_TX | |
J105_PIN9 | NET | 16 | NETLIGHT | |
J105_PIN10 | RXD | 17 | UART1_RX | |
J105_PIN11 | GND | – | – | |
J105_PIN12 | UART2_RX | 28 | UART2_RX | |
J105_PIN13 | MISO | 3 | SPI_MISO | |
J105_PIN14 | UART2_TX | 29 | UART2_TX | |
J105_PIN15 | MOSI | 4 | SPI_MOSI | |
J105_PIN16 | GND | – | – | |
J105_PIN17 | SCLK | 5 | SPI_SCLK | |
J105_PIN18 | DBG_TX | 39 | DBG_TXD | |
J105_PIN19 | CS | 6 | SPI_CS | |
J105_PIN20 | DBG_RX | 38 | DBG_RXD |
The pin definition of J106 is shown in the figure below.
Table 12: The pin description of J106 on EVB
Position | Test point | Signal name | Description |
J106 | J106_PIN1 | 5V | EVB 5V power supply test point |
J106_PIN2 | GND | GND |
The pin definition of J107 is shown in the figure below.
Table 13: The pin description of J107 on EVB
Position | Test point | Signal name | Description |
J107 | J107_PIN1 | RESET | Module reset signal |
J107_PIN2 | GND | GND | |
J107_PIN3 | WAKEUP | Module wake-up signal |
![]() 1. For the related functions of each pin of the module, please refer to document [1] |
Operation Method
Module Boot
Module Power-on Operation
The module boot method is as follows
- Insert the Micro USB into the USB connector J103 (or J104)
- Turn the switch SW101 up to the on state, and LED101, LED102, and LED103 will light up.
- If the module is successfully registered to the network, the flashing frequency of LED101 will slow down, otherwise LED101 will keep flashing fast. When the module enters PSM mode or the module is in shutdown state, LED101 will go out.
The module shutdown method is as follows:
- Turn the switch SW101 down to the off state, the module will automatically shut down, and LED101, LED102, and LED103 will go out.
- The module can be powered off by the AT command. When the module is in the power-on state, input the AT command “AT+CPOF” and the module will automatically power off. More details. Please refer to SIM7022 series _AT command.
Driver Installation
USB-to-UART Driver Installation
The following connection can get the USB to UART driver.
https://www.silabs.com/products/development-tools/software/usb-to-uart-bridge-vcp-drivers
After the driver is successfully installed, the following virtual serial port will appear, COM95/COM93/COM94
Table 14: USB to UART ports
Reference Number | Interface type | Port number | Serial port | Function description |
J103 | ECI | COM93 | Enhance UART | Used for AT communication, data transmission and firmware upgrade |
SCI | COM94 | Standard UART | / | |
J104 | / | COM95 | USB TO UART Bridge | Used for software DEBUG |
Firmware Upgrade Process
Before updating the firmware, please contact the SIMCom technical support team and the supplier to obtain the correct download tool and firmware upgrade file.
The firmware update method of the module is shown below
- Insert the Micro USB into the USB connector J103 (AT/DL UART), turn up SW101, SW1 to ON state
- Open the EiGENCOMM_MultiDownload tool and follow the steps.
(1) Check the “EraseALL” option.
(2) Select bootloader/system/calibration in turn and load the corresponding bin file.
(3) Select Enhanced port.
(4) Click “DL” and wait for the software to be erased.
- Erased the software.
- After completing the software erasing, enter the software download interface
- After entering the software download interface, press the “SW102” button and wait for the software to download.
Documents / Resources
![]() |
SIMcom SIM7022-EVB Cellular Module [pdf] User Guide 8EC0001, 2AJYU-8EC0001, 2AJYU8EC0001, SIM7022-EVB Cellular Module, Cellular Module |