PATLITE LR4-WC LED Signal Tower

Specifications

  • Model: Signal Tower TYPE L R 4 / L R 5 / LR6 / LR7
  • Operation Manual: Complete Installation Operation Maintenance
  • Safety Precautions: Included
  • Installation Instructions: Included
  • Warranty: Contact nearest PATLITE office for details

Safety Precautions

Before using the signal tower, ensure to read and understand the safety precautions mentioned in the manual to prevent any injury or damage. Follow all warning and caution instructions carefully.

Installation

Request a professional contractor to perform the installation if construction work is involved. Carefully follow the installation instructions provided in the manual to ensure proper setup.

Wiring

Refer to the wiring section of the manual for detailedinstructions on how to wire the signal tower correctly. Make sure to follow the wiring diagrams provided to avoid any e lectrical issues.

Buzzer Pattern Set-up

Follow the instructions in the manual to set up the buzzer pattern according to your requirements. Ensure that the buzzer sound is not exposed for long durations at close distances to prevent ear damage.

How to use the Folding Brace
Properly utilize the folding bracket as described in the manual for mounting the signal tower securely. Ensure that the folding bracket is correctly attached to avoid any detachment issues.

Unit Detachment Method
If you need to detach any unit of the signal tower, follow the provided method in the manual to avoid any damage to the product. Make sure to handle each unit carefully during detachment.

Troubleshooting

Refer to the troubleshooting section in the manual in case of any issues with the signal tower. Follow the steps provided to identify and resolve common problems that may arise during usage.

FAQs

Q: Is it safe to operate the signal tower without following the safety precautions?
A: It is not recommended to operate the signal tower without following the safety precautions as it may lead to injury or damage.

Q: Can I install the signal tower myself without a professional contractor?
A: It is advised to request a professional contractor for installation, especially if construction work is involved, to ensure proper setup and safety.

“`

B95100502_08

Signal Tower TYPE L R 4 / L R 5 /
LR6 / LR7
Complete Operation Manual
Installation Operation Maintenance

Thank you very much for purchasing our PATLITE product.
Notice to Customer
Request the installation and wiring be performed by a professional contractor if construction work is involved.
Prior to installation, read this manual thoroughly before using this product to ensure correct use.
After reviewing this manual, if there are any questions regarding this product, please contact the nearest PATLITE office listed on the back cover of this manual.
Notice to Contractor
Read this manual carefully prior to installation. Be sure to return this manual to the customer.
1

Page

1 Safety Precautions

2

2 Model Number

3

Configuration

3 Part Names and

7

Outer Appearance

4 Installation

21

5 Wiring

25

6 Buzzer Pattern Set-up 38

7 How to use

39

the Folding Bracket

8 Unit Detachment

40

Method

9 Troubleshooting

55

10 Specifications

56

11 Replacement Parts

62

12 Optional Parts

64

1 Safety Precautions
1 NOTES TO BE OBSERVED FOR SAFE OPERATION
In order to prevent any damage to the user and other personnel or to assets, note the following: The indications for warning are divided into the following classes according to the degree of danger or damage incurred
when the warning is not taken into consideration and the product is not correctly used.

Indicates an imminently dangerous condition:
Warning failure to follow the instructions may lead to death or serious injury.

Indicates a potentially dangerous condition:
Caution failure to follow the instructions may lead to slight injury or property damage.

Warning
To prevent from short-circuits, electric shock or damage, observe the following: – Be sure the power is disconnected before replacement or repair, including the replacement of the fuse. – Use this product in a properly maintained condition. (Replace or repair if the body, LED unit, etc. are damaged.)
Request the installation and wiring be performed by a professional contractor if construction work is involved. Failure to comply may result in fire, electric shock or falling from high places possible cause of failure may occur.

Caution
Avoid long exposure to the Buzzer sound from a close distance. Failure to observe this may lead from irritation to permanent damage to the ears. ( B Flashing/Buzzer)
In order to maintain protection of this product against dust and waterproofing performance, be sure to use the head cover, LED unit and buzzer unit in the condition that it was originally attached.
Do not operate this product without the O-ring or the waterproof packing material. Failure to comply will result in lower waterproofing performance. Possible cause of failure may occur.
Do not apply voltage to the Flashing Common line ( 0 1 , 0 2 ). Apply voltage to the power source line ( M 2 ) only. Product failure will occur.
When removing covers or packing from the equipment, which is attached to this product, be careful not to snag the product. Failure to comply may result in damage to the product.

Notice
To ensure proper safety while using the signal tower, observe the following: – Perform periodic pre-maintenance. – As a precaution against problems occurring, use this product together with other equipment.
Be sure to discharge any static electricity from the body before handling static sensitive parts of this product. (To prevent damage from static electricity, touch hands or other body parts to metals or an earth ground to discharge the body from static charge.)
Use a soft cloth moistened with water when the LED Unit or body must be cleaned up. (Do not use thinner, benzine, gasoline or oil.)
With a buzzer unit installed, moisture and oil that adheres to the buzzer unit will influence the sound pressure or tone quality produced, when an abundance is collected on the top surface of the buzzer unit. Be sure to periodically wipe off foreign objects with a soft cloth, etc.
To ensure safety when this product is installed onto equipment, observe the following: – Do not remove parts beyond those designed to be removed from this product. – Do not modify or disassemble this product. – Use only the specified replacement parts listed in this manual.
Trademarks
Company and product names in this manual are the trademarks or registered trademarks of the respective companies.

2

2 Model Number Configuration

Model

Tiers

Rated Voltage

Mounting/ Wiring

Flashing/Buzzer Body Color

LED Unit Color

Globe Color

Assembly Model L R 4 –

– RYGBC

Unit Model (Body Unit)

LR 4 –

4 40

1 – 5 Tiers

B With Flashing/Buzzer3

0 2 24V DC

N No Flashing/Buzzer

1 L R 4 – W JL JP J W 2 L R 4 – 02 W
3 Assembly Model 4 L R 4 – 02 W JL JP J 5 Body Unit
L R 4 – 02 W

M 2 100-240V AC 1
W J Direct Mount / Cable L J Pole Mount with L-bracket / Cable P J Pole Mount with Circular Bracket
/ Cable
Q J Pole Mount with Folding Bracket / Cable2
W C Direct Mount / M12 Connector5 (Mouning with M30 Nut)

W Off-white U Silver4
LED Color: RRed/YAmber/ GGreen/BBlue/CWhite From top to bottom
NoneColor Globe
Z Clear Globe

Model Number Example
LR4-502PJBU-RYGBC
40 LED 5 Tiers 24V DC Pole Mount with Circular Bracket / Cable With Flashing/Buzzer Silver From top) RedAmberGreenBlueWhite Color Globe
LR4-302WJBW-RYGZ
40 LED 3 Tiers 24V DC Direct Mount / Cable With Flashing/Buzzer Off-white From top) RedAmberGreen Clear Globe
LR4-402QJNW-RYGB
40 24V DC Pole Mount with Folding Bracket / Cable No Flashing/Buzzer Off-white From top) RedAmberGreenBlue Color Globe
LR4-02WCNW
40 24V DC Direct Mount / M12 Connector (Mounting with M30 Nut) No Flashing/Buzzer Off-white
LR4-M2LJNW
40 100 – 240V AC Pole Mount with L-bracket / Cable No Flashing/Buzzer Off-white

3

Model

Tiers

Assembly Model L R 5 –

Unit Model (Body Unit)

LR 5 –

Rated Voltage

Mounting/ Wiring

Flashing/Buzzer Body Color

LED Unit Color

Globe Color

– RYGBC

5 50

1 – 5 Tiers

B With Flashing/Buzzer3

0 1 12V DC

N No Flashing/Buzzer

1 L R 5 – 02 2 Body Unit L R 5 – 02 3 Assembly Model 4 Body Unit
L R 5 – W TK T

0 2 24V DC
W J Direct Mount / Cable L J Pole Mount with L-bracket / Cable P J Pole Mount with Circular Bracket
/ Cable

W Off-white U Silver4 K Black4
LED Color: RRed/YAmber/ GGreen/BBlue/CWhite From top to bottom

W T Direct Mount / Terminal1 K T Mounting Bracket with knock-outs
/ Terminal (Body Unit)2

NoneColor Globe

Model Number Example
LR5-502PJBW-RYGBC
50 LED 5 Tiers 24V DC Pole Mount with Circular Bracket / Cable With Flashing/Buzzer Off-white From top) RedAmberGreenBlueWhite Color Globe
LR5-302WJBW-RYG
50 LED 3 Tiers 24V DC Direct Mount / Cable With Flashing/Buzzer Off-white From top) RedAmberGreen Color Globe
LR5-301LJNW-RYG
50 LED 3 Tiers 12V DC Pole Mount with L-bracket / Cable No Flashing/Buzzer Off-white From top) RedAmberGreen Color Globe
LR5-02WTNU
50 24V DC Direct Mount / Terminal No Flashing/Buzzer Silver
LR5-02KTNK
50 24V DC Mounting Bracket with knock-outs / Terminal No Flashing/Buzzer Black

4

Model

Tiers

Assembly Model L R 6 –

Unit Model (Body Unit)

LR 6 –

Rated Voltage

Mounting/ Wiring

Flashing/Buzzer Body Color

LED Unit Color

Globe Color

– RYGBC

6 60

1 – 5 Tiers

B With Flashing/Buzzer3

1 L R 6 – W JL JP J W 2 L R 6 – 02

0 2 24V DC

N No Flashing/Buzzer

3 Assembly Model

M 2 100-240V AC 1

W Off-white

4 L R 6 – 02 W JL JP J 5 Body Unit L R 6 – 02 W

U Silver4

6 L R 6 – 02 W4W5W8

K Black6

L R6 – 02 L4L5L8

W J Direct Mount / Cable

W4/W5/W8 WC

LED Color: RRed/YAmber/ GGreen/BBlue/CWhite

L J Pole Mount with L-bracket / Cable P J Pole Mount with Circular Bracket
/ Cable
Q J Pole Mount with Folding Bracket / Cable2
W M Direct Mount / M12 Connector5

Direct Mount / M12 Connector2 (Mounting with M30 Nut) W4 : 4pin, W5 : 5pin, W8/WC : 8pin
L4/L5/L8
Pole Mount with L-bracket / M12 Connector2 L4 : 4pin, L5 : 5pin, L8 : 8pin

From top to bottom
NoneColor Globe
Z Clear Globe

Model Number Example
LR6-502PJBU-RYGBC
60 LED 5 Tiers 24V DC Pole Mount with Circular Bracket / Cable With Flashing/Buzzer Silver From top) RedAmberGreenBlueWhite Color Globe
LR6-302WJBW-RYGZ
60 LED 3 Tiers 24V DC Direct Mount / Cable With Flashing/Buzzer Off-white From top) RedAmberGreen Clear Globe
LR6-402QJNW-RYGB
60 24V DC Pole Mount with Folding Bracket / Cable No Flashing/Buzzer Off-white From top) RedAmberGreenBlue Color Globe
LR6-302W5BW-RYG
60 LED 3 Tiers 24V DC Direct Mount (Mounting with M30 Nut) M12 Connector 5pins With Buzzer Off-white From top) RedAmberGreen Color Globe
LR6-02WMNW
60 24V DC Direct Mount / M12 Connector No Flashing/Buzzer Off-white
LR6-M2LJNW
60 100 – 240V AC Pole Mount with L-bracket / Cable No Flashing/Buzzer Off-white
LR6-502L8NW-RYG
60 LED 5 Tiers 24V DC Pole Mount with L-bracket M12 Connector 8pins No Buzzer Off-white From top) RedAmberGreenBlueWhite Color Globe
5

Model

Tiers

Assembly Model L R 7 –

Unit Model (Body Unit)

LR 7 –

Rated Voltage

Mounting/ Wiring

Flashing/Buzzer Body Color

LED Unit Color

Globe Color

– RYGBC

7 70
1 Body Unit 2 Assembly Model 3 Body Unit
L R 7 – W TK T

1 – 5 Tiers 0 2 24V DC

B With Flashing/Buzzer2 N No Flashing/Buzzer

W J Direct Mount / Cable W T Direct Mount / Terminal (Body Unit)1
K T Mounting Bracket with knock-outs / Terminal (Body Unit)1

W Off-white U Silver3 K Black3
LED Color: RRed/YAmber/ GGreen/BBlue/CWhite From top to bottom
NoneColor Globe

Model Number Example
LR7-502WJBW-RYGBC
50 LED 5 Tiers 24V DC Direct Mount / Cable With Flashing/Buzzer Off-white From top) RedAmberGreenBlueWhite Color Globe
LR7-02WTNU
70 24V DC Direct Mount / Terminal No Flashing/Buzzer Silver
LR7-02KTNK
70 24V DC Mounting Bracket with knock-outs / Terminal No Flashing/Buzzer Black

6

3 Part Names and Outer Appearance
Outer Appearance List The full product appearance is indicated according to its model number. Refer to the model numbers as a reference to its appearance. Body Color: Off-White , Globe: Color Globe
Assembly Model

Model LED Tiers Rated Voltage Mounting/Wiring Flashing/Buzzer

02

M2

WJ

B NB N

LR4

1 5 5 Tier – Tiers (Drawing is

Tiers.)

02

M2

02

M2

LJ

PJ

BNBNBNBN

02 QJ BN

Model LED Tiers Rated Voltage Mounting/Wiring Flashing/Buzzer

LR5

1 5 5 5 Tier – Tiers (Drawing is

Tiers.)

Tiers

01 / 02

02

WJ

LJ

PJ WT

B NB NB NB

Model LED Tiers Rated Voltage Mounting/Wiring Flashing/Buzzer

02

M2

WJ

B NB N

LR6

1 5 5 Tier – Tiers (Drawing is

Tiers.)

02

M2

02

M2

LJ

PJ

BNBNBNBN

02 QJ BN

Model LED Tiers Rated Voltage Mounting/Wiring
Buzzer

-3

8 8 8$ 8

– –

/#

/

#/ #

– /#

Model LED Tiers Rated Voltage Mounting/Wiring Flashing/Buzzer

-3
8+ #/

8

Unit Model (Body Unit)

Model Rated Voltage Mounting/Wiring Flashing/Buzzer

02 M2 WJ

LR4

02 M2 02 M2

LJ

PJ

N

02 QJ WC

LR5 01 / 02 WJ LJ PJ
N

Model Rated Voltage Mounting/Wiring Flashing/Buzzer

02 M2 WJ

02 M2 LJ

LR6

02 M2

02

PJ

QJ W8 WC WM L8

N

Model Rated Voltage Mounting/Wiring Flashing/Buzzer

LR5 WT KT

LR7 02 WT KT WJ N

9

Part Name and Dimensions

[W J Direct Mount with Cable
LR – WJB LR4 : 40 , LR5 : 50 LR6 : 60 , LR7 : 70

1

53.5

2

3

3

40

01 , 02
LR – WJN
LR4 : 40 , LR5 : 50 LR6 : 60 , LR7 : 70
19 40

Unit: mm

LR- 1 : 173.5 LR- 2 : 213.5 LR- 3 : 253.5 LR- 4 : 293.5 LR – 5 : 333.5

4

4

5

5

LR – : 99 LR – 1 : 139 LR – 2 : 179 LR – 3 : 219 LR- 4 : 259 LR – 5 : 299

No.

Name

1 Buzzer Unit

2 Head Cover

3 LED Unit

4 Body

5 Direct Mount Bracket

6 Waterproof Packing

7 Cable

Material PC PC
Globe: PC PC PC
Silicone Rubber PVC

6

12

6

12

(90)

7

7

W[ J

Maximum Board Thickness : 7 Cable : UL2464 (7.5)
Signal Wire & Power Supply Wire : AWG24
Cable Length: Off-white (1300) Silver 3300
Direct Mount with Cable M2

LR – M2WJBW LR4 : 40 , LR6 : 60

LR – M2WJNW

LR4 : 40 , LR6 : 60

53.5

19

40

40

(90)

Accessory

LR4·5 – WJ

LR6·7 – WJ

Hexagon Nut with FlangeM3 Hexagon Nut with FlangeM4

3 pcs.

3 pcs.

LR-1M2 : 243.5 LR-2M2 : 283.5 LR-3M2 : 323.5 LR-4M2 : 363.5 LR-5M2 : 403.5

LR- M2 : 169 LR-1M2 : 209 LR-2M2 : 249 LR-3M2 : 289 LR-4M2 : 329 LR5M2 : 369

12

12

(90)

(90)

Maximum Board Thickness : 7 Cable : UL2464 (7.5)
Signal Wire : AWG24
Power Supply Wire : AWG18
Cable Length: (1300)

10

L J L-bracket and Pole Mount with Cable 0 1 , 0 2

LR – LJB LR4 : 40 , LR5 : 50 , LR6 : 60

LR – LJN

LR4 : 40 , LR5 : 50 , LR6 : 60

1

53.5

2

19

3

3

40

40

Unit: mm

LR – 1 : 173.5 LR – 2 : 213.5 LR – 3 : 253.5 LR – 4 : 293.5 LR – 5 : 333.5

LR – : 99 LR – 1 : 139 LR – 2 : 179 LR – 3 : 219 LR – 4 : 259 LR – 5 : 299

No.

Name

1 Buzzer Unit

2 Head Cover

3 LED Unit

4 Body

5 Pole Bracket

6 Pole

7 Rubber Bushing

8 Cable 9 L-bracket

10 Hexagon Nut M22

Material PC PC
Globe: PC PC PC AL EPR PVC Steel SUM

4

4

5

(15)

5

(15)

6

6

21.7

(285)

10

10

9

9

21.7 (285)

7

7

(90)

(20) (90) 80

8

8

3

20

55

Cable : UL2464 (7.5) Signal Wire & Power Supply Wire : AWG24
Cable Length: Off-white (1000) Silver 3000LR4, LR6

11

L J L-bracket and Pole Mount with Cable M 2

LR – M2LJBW LR4 : 40 , LR6 : 60

LR – M2LJNW

LR4 : 40 , LR6 : 60

1

53.5

2

19

3

3

40

40

Unit: mm

LR-1M2 : 243.5 LR-2M2 : 283.5 LR-3M2 : 323.5 LR-4M2 : 363.5 LR-5M2 : 403.5

LR- M2 : 169
LR-1M2 : 209 LR-2M2 : 249 LR-3M2 : 289 LR-4M2 : 329 LR-5M2 : 369

No.

Name

1 Buzzer Unit

2 Head Cover

3 LED Unit

4 Body

5 Pole Bracket

6 Pole

7 Rubber Bushing

8 Cable 9 L-bracket

10 Hexagon Nut M22

Material PC PC
Globe: PC PC PC AL EPR PVC Steel SUM

4

4

5

(15)

5

(15)

6

6

21.7

(285)

10

10

9

9

21.7 (285)

7

7

(90)

(20) (90) 80

8

8

3

20

55

Cable : UL2464 (7.5) Signal Wire : AWG24
Power Supply Wire : AWG18
Cable Length : (1000)

12

P J Circular Bracket and Pole Mount with Cable 0 1 , 0 2 )

LR – PJB LR4 : 40 , LR5 : 50 , LR6 : 60

LR – PJN

LR4 : 40 , LR5 : 50 , LR6 : 60

1

53.5

2

19

3

3

40

40

Unit: mm

LR – 1 : 173.5 LR – 2 : 213.5 LR – 3 : 253.5 LR – 4 : 293.5 LR – 5 : 333.5

LR – : 99 LR – 1 : 139 LR – 2 : 179 LR – 3 : 219 LR – 4 : 259 LR – 5 : 299

No.

Name

1 Buzzer Unit

2 Head Cover

3 LED Unit

4 Body

5 Pole Bracket

6 Pole

7 Circular Bracket

8 Waterproof Packing

9 Cable

Material PC PC
Globe: PC PC PC AL PC
Silicone Rubber PVC

4

4

5

(15)

5

(15)

6

21.7 6

21.7

Accessory LR4·5·6 – PJ Cross Recessed Pan Head ScrewM4x20
3pcs. Hexagon Nut with FlangeM4
3pcs.

(290)

(290)

7

7

35

35

(6)

(6)

12.5

12.5

(90)

(90)

8

Maximum Board Thickness : 7.5 Cable : UL2464 (7.5)

8

Signal Wire & Power Supply Wire : AWG24

60

9

60

9

Cable Length: Off-white (1000)

Silver 3000LR4, LR6

13

P J Circular Bracket and Pole Mount with Cable M 2

LR – M2PJBW LR4 : 40 LR6 : 60

LR – M2PJNW
LR4 : 40 LR6 : 60

1

53.5

2

19

3

3

40

40

LR-1M2 : 243.5 LR-2M2 : 283.5 LR-3M2 : 323.5 LR-4M2 : 363.5 LR-5M2 : 403.5

LR- M2 : 169 LR-1M2 : 209
LR-2M2 : 249 LR-3M2 : 289 LR-4M2 : 329
LR-5M2 : 369

4

4

5

(15)

5

(15)

6

21.7

6

21.7

Unit: mm

No.

Name

1 Buzzer Unit

2 Head Cover

3 LED Unit

4 Body

5 Pole Bracket

6 Pole

7 Circular Bracket

8 Waterproof Packing

9 Cable

Material PC PC
Globe: PC PC PC AL PC
Silicone Rubber PVC

Accessory LR4·6 – PJ Cross Recessed Pan Head ScrewM4x20
3pcs. Hexagon Nut with FlangeM4
3pcs.

(290)

(290)

7

7

35

35

(6)

(6)

12.5 (90)

12.5 (90)

Maximum Board Thickness : 7.5 Cable : UL2464 (7.5)

8

8

Signal Wire : AWG24 Power Supply Wire : AWG18

60

9

60

9

Cable Length : (1000)

14

Q J Folding Bracket and Pole Mount with Cable 0 2

LR – 02QJBW LR4 : 40 LR6 : 60
1 53.5
3 40

LR – 02QJNW
LR4 : 40 LR6 : 60 2
19 3
40

Unit: mm

LR – 102 : 173.5 LR – 202 : 213.5 LR – 302 : 253.5 LR – 402 : 293.5 LR – 502 : 333.5

LR – 02 : 99 LR – 102 : 139 LR – 202 : 179 LR – 302 : 219 LR – 402 : 259 LR – 502 : 299

No.

Name

1 Buzzer Unit

2 Head Cover

3 LED Unit

4 Body

5 Pole Bracket

6 Pole

7 Folding Bracket

8 Waterproof Packing

9 Cable

Material PC PC
Globe: PC PC PC AL PC CR PVC

4

4

5

(15)

5

6

21.7

6

(335)

(15) 21.7
(335)

Accessory
LR4·6 – QJ
Cross Recessed Binding Head ScrewM5x25

4pcs. Hexagon Nut with FlangeM5

4pcs.

Fixed Position

45°

45° 90°

7 19.3 8

70

7 79 (49)
(90) 19.3
98

70

79 (49)

(90) Maximum Board Thickness : 14.3

Cable : UL2464 (7.5)

Signal Wire & Power Supply Wire : AWG24

9

Cable Length: (950)

15

WC Direct Mount with M12 Connector Mouning with M30 Nut, Body Unit

Unit: mm

LR4 – 02WCNW 40

19

93.9

No.

Name

1 Head Cover

2 Body

3 Waterproof Packing

4 M30 Nut

5 M12 Connector

Material PC PC
Silicone Rubber PC
Brass

10

20

.

Maximum Board Thickness : 8

WC Direct Mount with M12 Connector Mouning with M30 Nut

LR6 – 02WCNW 60
1 19

2

40

Unit: mm

LR6 – 02 : 126 LR6 – 302 : 246
3

No.

Name

1 Head Cover

2 LED Unit

3 Body

4 Direct Mount Bracket

5 Waterproof Packing

6 M30 Nut

Material PC
Globe: PC PC PC
Silicone Rubber PC

4

5

10

25

6 52

M301.5

1/2” NPT Internal Threads

Maximum Board Thickness : 10

16

W4/W5/W8 Direct Mount with M12 Connector Mouning with M30 Nut

LR6-02WBW 60

1

53.5

3
40

LR6-02WNW

60
2
19

3

40

Unit: mm

No.

Name

1 Buzzer Unit

2 Head Cover

3 LED Unit

4 Body

5 Direct Mount Bracket

6 Waterproof Packing

7 M30 Nut

Material PC PC
Globe: PC PC PC
Silicon Rubber PC

LR6-102 : 200.5 LR6-202 : 240.5 LR6-302 : 280.5 LR6-402 : 320.5 LR6-502 : 360.5

LR6- 02 : 126 LR6-102 : 166 LR6-202 : 206 LR6-302 : 246 LR6-402 : 286 LR6-502 : 326

4 4

5 5

6

10

6

25

10 25

7

Maximum Board Thickness : 10

7

52

M30×1.5

52

M30×1.5

1/2” NPT Internal Threads

1/2” NPT Internal Threads

17

L4/L5/L8 L-bracket and Pole Mountwith M12 Connector

Unit: mm

No.

Name

Material

1 Buzzer Unit

PC

2 Head Cover

PC

3 LED Unit

Globe: PC

4 Body

PC

5 Pole Bracket

PC

6 Pole

AL

7 Gromet

Silicone Sponge

8 L-Bracket

Steel

9 Heagon Nut M22

SUM

-3 -3 -3 -3 -3

-3 -3 -3 -3 -3 -3

18

WM Direct Mount with M12 Connector Body Unit

LR6 – 02WMNW 60
1 19
2
132

3

4

12

No.

Name

1 Head Cover

2 Body

3 Direct Mount Bracket

4 Waterproof Packing

Accessory LR6 – WM Hexagon Nut with FlangeM4

Material PC PC PC
Silicone Rubber

3 pcs.

WT Direct Mount with Terminal Block
LR5 – 502WTBW LR5 : 50
1 53.5
2 40

Unit: mm

LR5 – 502 : 333.5

3

4

5

12

Maximum Board Thickness : 7

No.

Name

1 Buzzer Unit

2 LED Unit 3 Body 4 Direct Mount Bracket 5 Waterproof Packing

Accessory LR5 – WT Hexagon Nut with FlangeM3

Material PC
Globe: PC PC PC
Silicone Rubber

3 pcs.

19

WT Direct Mount with Terminal Block (Body Unit)

Unit: mm

LR – 02WTN
LR5 : 50 LR7 : 70 1
19 2

3

80

4

12

Maximum Board Thickness: 7

No.

Name

1 Head Cover

2 Body

3 Direct Mount Bracket

4 Waterproof Packing

Material PC PC PC
Silicone Rubber

Accessory

LR5 – WT

LR7 – WT

Hexagon Nut with FlangeM3Hexagon Nut with FlangeM4

3 pcs.

3 pcs.

KT Mounting Bracket with knock-outs and Terminal (Body Unit)

Unit: mm

LR5 : 50 LR7 : 70 1
19
2

3

80

4

No.

Name

Material

1 Head Cover

PC

2 Body

PC

3 Mounting Bracket with knock-outs

PC

4 Waterproof Packing

Silicone Rubber

Accessory

LR5 – KT
Hexagon BoltM3 x 20

LR7 – KT
Hexagon BoltM4 x 20

3 pcs.

3 pcs.

Hexagon Nut with FlangeM3 Hexagon Nut with FlangeM4

6 pcs.

6 pcs.

Pole Waterproof Ring

Pole Waterproof Ring

1 pc.

1 pc.

20

4 Installation
Notice
The following requirements are necessary for proper installation: – Install the signal tower where excessive vibration is not present. – Install the signal tower on a sturdy surface. – Install the signal tower on a level surface.
Install the signal tower in an upright position only. When the installation location is unavoidably irregular and waterproof performance is required, use a sealant between
the product and the installation surface. If the pole type requires an IP65 rating, apply sealant to the screws, nuts and wire distribution hole when installing the
compatible bracket onto the installation surface. ( P J Q J ) Although the LR4- W J mounting bolt moves prior to assembly, it is not a quality issue. Be sure to mount the product in
the manner indicated below.
Basic Mounting Instructions
1 Make holes for the mounting and wire-distribution for the product.
(Check the Model and refer to the suitable attachment or mounting dimension figure.) ( KT Select among the two mounting options.)
2 Run the wiring through the distribution hole.
3 Secure the product with the bolts, nuts and screws. ( LJ L4/L5/L8 required nuts and screws are not included.)

L JL 4 / L 5 / L 8 Installation Figure
(Unit: mm)

For M8 screw and nut size

L-bracket

1

Mounting Hole

(9)

23
Feed the wiring through the hole and set the pole in place to install.
Recommended Nut Torque
30 N m
Point
When not using a L-bracket attachment, make a fitting hole of 22-23mm.

3

20

Mounting Surface

For M10 screw and nut size

L-bracket

1

Mounting Hole

(11)

3
Opposite Side 27
21

35
Mounting Surface Recommended screw Torque
12.2 N m

K T Select between “Direct” or “Pole” mounting
Direct Mount
1.Place the Mounting Bracket on an even surface. 2.Be sure to remove the waterproof packing from the Mounting Bracket. 3.Knock out the three knock-out holes with a steel punch, etc. 4.Insert the hexagon bolt into the knockout holes and affix with the flanged nuts. 5.Insert the waterproof packing.

Unit: mm

Mounting Bracket with knock-outs Underside
Steel Bar etc. LR5 3 LR7 4

Mounting Bracket with knock-outs Topside
Hexagon Bolt

Flanged Nut Recommended Torque
0.8 N m
Waterproof Packing

Point After inserting accessories, check the bolt length.

Knock-Out Mount Bracket Side 12

Pole Installation

Binding Head Tapping Screw

3×122pcs.

Recommended Torque 0.8 N m

1. Be sure to remove the waterproof packing from
the Mounting Bracket. 2. Install the Pole Waterproof Ring in the Mounting Bracket.

Check that the 2 ribs are on the outside.

Mounting Bracket

Pole Waterproof Ring
Pole Not included with
this product.

3. Insert Pole into the Mounting Bracket. See the figure on the left for details on the direction of insertion.
4. Tighten the Binding Head Tapping Screws (2 pcs.) from the topside of the Mounting Bracket.

22

W J P J W MW T K T Mounting Dimensional Drawing
(Unit: mm)

120°

120°

Mounting Hole

(3 places)

LR45-WJ LR5-WTKT

4

LR456-PJ

LR67-WJ 5 LR6-WM

LR7-WTKT

Screw/ Nut
M3
M4

Nameplate Position

LR45-WJ LR5-WTKT

30

LR456-PJ

LR67-WJ 40 LR6-WM

LR7-WTKT

()KTDirect Mount

Wire Distribution Hole (12 ),(20) 2

() WM only

Recommended Torque

0.6 N m

Q J Mounting Dimensional Drawing
(Unit: mm)
Mounting Hole (6×4 places) Mounting Hole (6×4 places)
Screw/Nut ×pcs
54 – 56
73
Nameplate Position

90° Wire Distribution Hole (15)
18.5
From the center of the pole
36.9
Bracket Outer Dimension
Recommended Torque
1.4 N m

23

W C W 4 / W 5 / W 8 Mounting Dimensional Drawing (M30x1.5 Installation)

(Unit: mm)

28.5 15°

Mounting Hole Nut

31

M30

Nameplate Position

Distribution Hole
Recommended Torque 4.5 N m

L R 6 – W 4 / W 5 / W 8 W C Installation Figure (1/2″ NPT Installation Figure)
(Unit: mm)
While holding part ‘A’, install the 1/2″ NPT. Failure to comply may result in damage.

A

A

1/2″ NPT
Recommended Torque 2.25 N m

24

5 Wiring
Warning
Be sure the power is disconnected before wiring and changing fuses. Possible cause of short-circuiting may occur. Ensure the proper working voltage is used and that direct current or alternating current is properly applied.
Possible cause of damage may occur.

Caution
Do not apply voltage to the Flashing Common line( 0 1 , 02 ). Apply voltage to the source line ( M 2 ) only. Failure to comply will result in product damage.
Do not control the flashing display by switching the power source ON and OFF for M2 . Product failure will occur. It is not necessary to connect to an external lead for tiers not used. When an extra lead is not connected, it should be
individually insulated with electrical tape or something similar. Failure to comply will result in damage due to short circuiting. Do not pull the lead wire or push it inside the body. Product failure may occur.
Notice
When using multiple LED units of the same color, make the contact capacity equal to the number of same color LED units multiplied by the contact capacity for 1 tier. (This is because LED units of the same color light up for one signal line.)
To protect the power supply and other internal circuitry, be sure to install an external fuse. If wiring is extended beyond its factory length, a relevance in the length of the wire and wire gauge will cause a
voltage drop.

LED Red

Wiring Example Index WJ LJ PJ QJ WT KT Red /

Function Name

Pin No.
( ) WT Direct Mount with Terminal Block, K T Mounting Bracket with knock-outs Terminal Block

Refer to pg. 37 “Terminal Block Array” Refer to pg. 35 “M12 Connector Pin Layout”

Lead Wire Color Cable type
NoteThe lead wire color does not indicate the LED luminescence color.

Wiring Example Index WC WM W4/W5/W8 L4/L5/L8 LED Red

Function Name

Pin No.
( ) WC W4/W5/W8 Direct Mount / M12 Connector (Mounting with M30 Nut), W M Direct Mount with M12 Connector, L4/L5/L8 Pole Mount with L-bracket / M12 Connector
Refer to pg. 35 “M12 Connector Pin Layout”

25

Wiring Example

The following is a basic wiring example. If there are any special applications that require asking questions concerning this product, feel free to contact your PATLITE Sales Representative. Accidental wiring will result in product failure.
<Note> When lighting and flashing are used together, it is necessary to prepare an external contact for each lighting or flashing circuit.
Lighting / Flashing / Buzzer

Wire Type & Wire Gauge
Wire type UL2464
Wire Gauge 01 12V DC, 02 24V DC Signal Wire: AWG24 Power Supply Wire: AWG24

Product Specifications 0 1 12V DC 0 2 24V DC (Excluding 888 — )

M2 100 240 V AC Signal Wire:AWG24
Power Supply Wire: AWG18

External Contact Classification Voltage Contact Relay

LR4 LR7 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown / Red / Orange / Green / Blue / White / Purple /

Power Supply Wire Gray / Power Supply Wire Yellow /

Used when buzzer unit is attached.

Do not Apply Voltage!

Flashing/ Buzzer
External Contact

Lighting/ Buzzer
External Contact

Fuse

1A

12 V DC ( LR5 only) (Class 2) (No polarity)

24 V DC (Class 2) (No polarity)

Do not Apply Voltage!

External Contact Classification

PLC

PLC (NPN Transistor)

LR4 LR7 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown / Red / Orange / Green / Blue / White / Purple /

Power Supply Wire Gray / Power Supply Wire Yellow /

Used when buzzer unit is attached.

Fuse

1A

12 V DC ( LR5 only) (Class 2)

24 V DC (Class 2)

Flashing/ Buzzer Output Unit B
Lighting/ Buzzer Output Unit A
Transistor Schematic C
B E

External Contact Classification

Do not Apply Voltage!

PLC

PLCPNP Transistor

LR4 LR7 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown / Red / Orange / Green / Blue / White / Purple /

Power Supply Wire Gray / Power Supply Wire Yellow /

Used when buzzer unit is attached.

Fuse

1A

12 V DC ( LR5 only) (Class 2)

24 V DC (Class 2)

Flashing/ Buzzer Output Unit B
Lighting/ Buzzer Output Unit A
Transistor Schematic C
B E

26

Lighting / Flashing / Buzzer (LR6-E-MZ)
Product Specifications 0 2 24V DC

External Contact Classification Voltage Contact Relay

Do not Apply Voltage!

-3 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown Red OrangeNot used Green Blue White Not used Purple

Power Supply Wire Gray Power Supply Wire Yellow
Used when buzzer unit is attached.

Fuse

1A

24 V DC (Class 2) (No polarity)

External Contact Classification

Do not Apply Voltage!

1-$

PLC (NPN Transistor)

-3 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown Red OrangeNot used Green Blue White Not used Purple

Flashing/ Buzzer External Contact
Lighting/ Buzzer External Contact
Flashing/ Buzzer Output Unit B
Lighting/ Buzzer Output Unit A

Power Supply Wire Gray Power Supply Wire Yellow
Used when buzzer unit is attached.

Fuse

1A

24 V DC (Class 2)

Transistor Schematic
C B
E

External Contact Classification PLCPNP Transistor

Do not Apply Voltage!

-3 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown Red OrangeNot used
Green Blue White Not used Purple

1-$
Flashing/ Buzzer Output Unit B
Lighting/ Buzzer Output Unit A

Power Supply Wire Gray Power Supply Wire Yellow
Used when buzzer unit is attached.

Fuse 1A 24 V DC (Class 2)

Transistor Schematic
C B
E

Point
When flashing the LR6-E-MZ simultaneously with the LR6-E-R(Z)/Y(Z)/G(Z)/B(Z)/C, the flashing cycle of the LR6-E-MZ may shift from the other LED units.

LR6-E-MZ Luminous Color

LED Color

Wiring Color

Red

Red

Green

Green

Blue

Blue

Yellow

Red Green

Purple

Red Blue

Cyan

Green Blue

White

Red Green Blue

27

Lighting only Product Specifications

0 1 12V DC

0 2 24V DC

(Excluding 888 — )

External Contact Classification Voltage Contact Relay

LR4 LR7 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown /Not used Red / Orange / Green / Blue / White / Purple /Not used

Power Supply Wire Gray / Not used Power Supply Wire Yellow /

Fuse 1A

Lighting External Contact
12 V DC (LR5 only) (Class 2) (No polarity) 24 V DC (Class 2) (No polarity)

External Contact Classification PLC (NPN Transistor)

LR4 LR7 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown /Not used Red / Orange / Green / Blue / White / Purple /Not used

Power Supply Wire Power Supply Wire

Gray /Not used Yellow /

Fuse 1A

PLC
12 V DC ( LR5 only) (Class 2) 24 V DC (Class 2)

External Contact Classification PLCPNP Transistor

Lighting
Output Unit
Transistor Schematic C
B E

LR4 LR7 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

Brown /Not used Red / Orange / Green / Blue / White / Purple /Not used

Power Supply Wire Gray / Not used Power Supply Wire Yellow /

Fuse 1A

PLC
12 V DC ( LR5 only) (Class 2) 24 V DC (Class 2)

Lighting
Output Unit
Transistor Schematic C
B E

28

Lighting only (LR6-E-MZ)
Product Specifications 0 2 24V DC

External Contact Classification Voltage Contact Relay

-3 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer
Power Supply Wire Power Supply Wire

BrownNot used Red OrangeNot used Green Blue White Not used PurpleNot used
Gray Not used Yellow

Fuse 1A

24 V DC (Class 2) (No polarity)

Lighting External Contact

LR6-E-MZ Luminous Color

LED Color

Wiring Color

Red

Red

Green

Green

Blue

Blue

Yellow

Red Green

Purple

Red Blue

Cyan

Green Blue

White

Red Green Blue

External Contact Classification PLC (NPN Transistor)

-3

Flashing Common Line

BrownNot used

1-$

LED Red

Red

LED Amber

OrangeNot used

LED Green

Green

LED Blue

Blue

LED White

White Not used

Buzzer

PurpleNot used

Power Supply Wire Power Supply Wire

Gray Not used Yellow

Fuse 1A

24 V DC (Class 2)

Lighting
Output Unit
Transistor Schematic C
B E

External Contact Classification PLCPNP Transistor

-3

Flashing

Common Line

BrownNot used

1-$

LED Red

Red

LED Amber

OrangeNot used

LED Green

Green

LED Blue

Blue

LED White Buzzer

White Not used PurpleNot used

Power Supply Wire Gray Not used Power Supply Wire Yellow

Fuse 1A

24 V DC (Class 2)

Lighting
Output Unit
Transistor Schematic C
B E

29

Lighting / Flashing / Buzzer
Product Specifications . 100 – 240 V AC
Only apply voltage to Power Supply Wires.
External Contact Classification Voltage Contact Relay

LR4 , LR6

Flashing Common Line

#SPXO

LED Red

3FE

LED Amber

0SBOHF

LED Green

(SFFO

LED Blue

#MVF

LED White

8IJUF

Buzzer

1VSQMF

Lighting Common Line

:FMMPX

Power Supply Wire (SBZ

Power Supply Wire #MBDL

Used when buzzer unit is attached.

Fuse 1A

100 – 240 VAC

External Contact Classification PLC (NPN Transistor)

Only apply voltage to Power Supply Wires. PLC

LR4 , LR6 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

#SPXO 3FE 0SBOHF (SFFO #MVF 8IJUF 1VSQMF

Lighting Common Line

:FMMPX

Power Supply Wire (SBZ

Power Supply Wire #MBDL

Used when buzzer unit is attached.

Fuse 1A

100 – 240 VAC

Flashing/ Buzzer External Contact
Lighting/ Buzzer External Contact

Flashing/ Buzzer
Output Unit B

Lighting/ Buzzer
Output Unit A

Schematic

$

&

#

30

Lighting / Flashing / Buzzer (LR6-E-MZ)
Product Specifications . 100 – 240 V AC
Only apply voltage to Power Supply Wires.
External Contact Classification Voltage Contact Relay

LR6

Flashing Common Line

#SPXO

LED Red

3FE

LED Amber

0SBOHFNot used

LED Green

(SFFO

LED Blue

#MVF

LED White

8IJUF Not used

Buzzer

1VSQMF

Lighting Common Line

:FMMPX

Power Supply Wire (SBZ

Power Supply Wire #MBDL

Used when buzzer unit is attached.

Fuse 1A

100 – 240 VAC

Flashing/ Buzzer External Contact
Lighting/ Buzzer External Contact

LR6-E-MZ Luminous Color

LED Color

Wiring Color

Red

Red

Green

Green

Blue

Blue

Yellow

Red Green

Purple

Red Blue

Cyan

Green Blue

White

Red Green Blue

Only apply voltage to Power Supply Wires. PLC
External Contact Classification PLC (NPN Transistor)

LR6 Flashing Common Line LED Red LED Amber LED Green LED Blue LED White Buzzer

#SPXO 3FE 0SBOHFNot used (SFFO #MVF 8IJUF Not used 1VSQMF

Lighting Common Line

:FMMPX

Power Supply Wire (SBZ

Power Supply Wire #MBDL

Used when buzzer unit is attached.

Fuse 1A

100 – 240 VAC

Flashing/ Buzzer
Output Unit B

Lighting/ Buzzer
Output Unit A

Schematic

$

&

#

Point
When flashing the LR6-E-MZ simultaneously with the LR6-E-R(Z)/Y(Z)/G(Z)/B(Z)/C, the flashing cycle of the LR6-E-MZ may shift from the other LED units.

31

Lighting / Buzzer ( LR4-WC, LR6-W8/L8/WC/WM )
Product Specifications 0 2 W C W 8 L 8 W M 24V DC
External Contact Classification Voltage Contact Relay

LR4, LR6
LED Red LED Amber LED Green LED Blue LED White Buzzer
Power Supply Wire Power Supply Wire

Pin No.

Used when buzzer unit is attached.

External Contact Classification PLC (NPN Transistor)

Fuse

1A

24 V DC (Class 2) (No polarity)

Lighting/ Buzzer
External Contact

LR4, LR6

Pin No.

LED Red

PLC

LED Amber

LED Green

LED Blue

LED White

Buzzer

Power Supply Wire

Power Supply Wire

Used when buzzer unit is attached.

Fuse

1A

24 V DC (Class 2)

External Contact Classification PLCPNP Transistor

Lighting/ Buzzer Output
Unit
Transistor Schematic C
B E

LR4, LR6

Pin No.

LED Red

LED Amber

LED Green

LED Blue

LED White

Buzzer

Power Supply Wire

Power Supply Wire

Used when buzzer unit is attached.

PLC

Fuse

1A

24 V DC (Class 2)

Point The flashing function cannot be used.

Lighting/ Buzzer Output
Unit
Transistor Schematic C
B E

32

Lighting / Buzzer ( LR6-W4/W5/L4/L5 )
Product Specifications 0 2 W 4 / W 5 L 4 / L 5 24V DC
External Contact Classification Voltage Contact Relay

LR6
LED Red LED Amber LED Green

Pin No.

External Contact

Buzzer

Power Supply Wire

W5 L5 only External Contact Classification PLC (NPN Transistor)

Fuse

1A

24 V DC (Class 2) (No polarity)

LR6

Pin No.

LED Red

PLC

LED Amber

LED Green

Buzzer

Power Supply Wire

W5 L5 only

External Contact Classification PLCPNP Transistor

Fuse

1A

24 V DC (Class 2)

Transistor Schematic
C B
E

LR6

Pin No.

LED Red

PLC

LED Amber

LED Green

Buzzer

Power Supply Wire
W5 L5 only

Fuse

1A

24 V DC (Class 2)

Transistor Schematic
C B
E

33

Lighting / Buzzer (LR6-E-MZ)
Product Specifications 0 2 W 8 L 8 W M
External Contact Classification Voltage Contact Relay

-3

Pin No.

LED Red LED Amber LED Green LED Blue LED White Buzzer
Power Supply Wire Power Supply Wire

Not used Not used

Used when buzzer unit is attached.

Fuse 1A

24 V DC (Class 2) (No polarity)

External Contact Classification PLC (NPN Transistor)

Lighting External Contact

LR6-E-MZ Luminous Color

LED Color

Pin No.

Red

Green

Blue

Yellow

Purple Cyan

White

-3

Pin No.

1-$

LED Red

LED Amber

Not used

LED Green

LED Blue

LED White

Not used

Buzzer

Power Supply Wire

Power Supply Wire

Used when buzzer unit is attached.

Fuse

1A

24 V DC (Class 2)

External Contact Classification PLCPNP Transistor

Lighting
Output Unit
Transistor Schematic C
B E

-3

Pin No.

1-$

LED Red

LED Amber

Not used

LED Green

LED Blue

LED White

Not used

Buzzer

Power Supply Wire

Power Supply Wire

Used when buzzer unit is attached.

Fuse 1A 24 V DC (Class 2)

Point The flashing function cannot be used.

Lighting
Output Unit
Transistor Schematic C
B E

34

M12 Connector Pin Layout

4pin plug (male)

5pin plug (male)

LED Red

LED Amber

LED Red

2

1

3

4

LED Green

2

1

5

3

4

8pin plug (male)

LED Amber Buzzer
LED Green

Power Supply Wire Buzzer

LED Green LED Amber

2

8

4

6

Point . It is recommended
to use the M12 Connector Cable (Optional Part) for wiring.
LED White
LED Blue LED Red

Power Supply Wire

Power Supply Wire

Power Supply Wire

8 $ 8 8 8 – – – 8. Attach the M12 connector cable to the body unit

-38$

8$ 888 — 8.

M12 Connector (male)
M12 Connector Cable Not included with this product.

POINT

Recommended dimensions for M12 cable connectors.

15.6 or less

15 or less

12.5 or less

M12 cable with verified connections .

Maker Name

Model Number

OMRON

XS2F-D421-C80-F

XS2F-D521-GG0-A

Phoenix Contact

1567335

1454422

Harting

72T17000913

72T17000914

72T17000099

Number of Poles 4 5 4 5 4 5 8
35

– 3 – – – .DPOOFDUPSDBCMFDPOOFDUJPONFUIPE

1PMF

(SPNNFU

3FNPWFUIFHSPNNFUGSPNUIFQPMF

3VOUIF.DPOOFDUPSDBCMF UISPVHIUIFQPMFBOEDPOOFDUJUUP UIF.DPOOFDUPS

%FUBDINFOUUIFQPMFCSBDLFUGSPNUIFCPEZ 3FGFSUP6OJU%FUBDINFOU.FUIPE

#PEZ . $POOFDUPS NBMF

$POOFDUUIFDBCMFUP

UIF.DPOOFDUPS

5VSOUIFDPOOFDUFE

DBCMFJOUIFEJSFDUJPO

PGUIFBSSPX

1PMFCSBDLFU

1PMF
4MJUTFDUJPOPGHSPNNFU M12 $POOFDUPS DBCMF

“UUBDIUIFQPMFCSBDLFUUPUIFCPEZ 3FGFSUP6OJU%FUBDINFOU.FUIPE

*OTFSUUIF.DPOOFDUPSDBCMFUISPVHIUIFTMJUJO UIFHSPNNFUBOEJOTFSUUIFHSPNNFUJOUPUIFQPMF

/PUJDF
8IFOEJTDPOOFDUJOHUIF.DPOOFDUPSDBCMF
pSTUSFNPWFUIFHSPNNFUGSPNUIFQPMF *GUIFQPMFCSBDLFUJTSFNPWFEXJUIUIFHSPNNFUBUUBDIFE
UIFHSPNNFUNBZHFUJOTJEFUIFQPMF

#PEZ

1PMF (SPNNFU

1PMFCSBDLFU

3FNPWFUIFHSPNNFUGSPNUIFQPMF

3FNPWFUIFQPMFCSBDLFUGSPNUIFCPEZ BOESFNPWFUIF.DPOOFDUPSDBCMF

85 , 5 Terminal Block Array

1 Red

LED-R

2 Orange

LED-Y

3 Green

LED-G

4 Blue

LED-B

5 White

LED-C

6 Gray

Buzzer

7 Yellow Power Supply Wire (Common)

8 Gray

Flashing Common

9 Black Power Supply Wire (Signal-line Side)

85 , 5 5FSNJOBM#MPDL8JSJOH.FUIPE

Body Unit

Remove the connector from the body unit before wiring.

Lever

Terminal Block Connector

A minus driver etc. is used to pry the lever slot of the Terminal Block open, by pushing straight onto the lever slot.
The stripped side of the lead wire is inserted in the slot.
The driver is removed to release the lever. (Check to make sure the lead wire has been locked in place.)

Recommended Lead-wire Specifications

Wire Type Wire Gauge (Solid Wire) Wire Gauge (Stranded Wire)

UL1007 / UL1430

0.141.5mm2

AWG3014

Temperature rating should be above 750C, and the conductor material should be of copper wire.

1PJOU

The minus driver blade should be at about 2mm by 0.5mm in size.
Do not forcibly push the lever more than necessary with the driver. Failure to comply may damage the unit.
Strip 9 to 10mm of wire insulation from the wire to insert it in the Terminal Block.
When removing the lead wire, do not pull to remove, be sure to operate the lever to release the lock.

Attach the terminal block connector to the body unit after wiring.

The terminal block connector is attached to the body unit at all times after factory shipment. Refer to pg.53 for “Unit Detachment Method” for removal, wiring and attachment.
37

External Contact Capacity

IsCurrent Capacity VsWithstand Voltage ILLeakage Current TaAmbient Tenperature

Rated Load Voltage

LED Unit Signal Wire Current (Max.) / Voltage (1 Tier) Recommended Contact Capacity

Buzzer

Signal Wire Current (Max.) / Voltage Recommended Contact Capacity

Power Current Consumption (Max.)

Supply Recommended Contact Capacity

Signal Wire

Inrush Current

Power Supply Wire

12 V DC 100 mA / Power Supply Voltage

24 V DC 45 mA / Power Supply Voltage

Is 100 mA Vs 20 V DC1

Is 100 mA Vs 35 V DC

250 mA / Power Supply Voltage

250 mA / Power Supply Voltage

Is 300 mA Vs 20 V DC1 500 mA2

Is 300 mA Vs 35 V DC 250 mA2

Is 700 mA Vs 20 V DC

Is 500 mA Vs 35 V DC

LED None1Buzzer None1 LED None Buzzer None3

0.7A / Less than 15ms

None4

. 100 – 240 V AC 45 mA / 24V DC
Is 100 mA Vs 35 V DC 250 mA / 24 V DC
Is 300 mA Vs 35 V DC 150mA2
Inrush current or more contacts None
Ta=25^25A / Less than 2ms (Cold-start)
Ta=50^ 50A /

Less than 2ms (Cold-start)

Leakage Current

IL 0.1 mA

1 … When the ( (SBZ ) power supply wire is not connected,inrush current of 0.7A will flow through the signal wire. Recomended Contact Capacity : Is 700 mAVs 20 V DC
2 … Measured with five LED tiers and buzzer operating. 3 … Not exceeding Maximum Signal Wire Current Rating. 4 … Signal Wire Current (Max.) not exceeding the sum of total.

Recommended Fuse

Fuse Rated Current

250V / 1A 5x20mm Fast-Acting Glass Body Cartridge Fuse

Note When a regulated power supply is not being used, select a fuse that meets class CC or more ( . ). Use a fuse holder with UL standard certification ( . ). Be sure the power is disconnected before changing fuses.

Buzzer Pattern Set-up
5IF#Flashing/Buzzer type includes a set up for four different patterns and sound reduction. Set up the preferred pattern, using the DIP Switch after removing the buzzer unit.
Do not use excessive force to set up the switches. Possible damage or malfunction may occur.
Caution Do not adjust switches with a sharp object. Possible damage to switches may cause it to be impossible to operate or
cause partial movement of the contacts.
Buzzer Unit Underside View

Pattern Setup Table

Buzzer DIP Switch

Sound

1

2

OFF

OFF

No.1

ON

OFF

No.2

OFF

ON

No.3

ON

ON

No.4

DIP SwitchWhen down, it is “ON” Switch is shown by .

Sound Pattern Rapid Intermittent Beep Continuous Beep Sound

DIP Switch 3
OFF
ON

Volume Normal Sound Reduction

Rapid Hi-Lo Sweep Sound

NoteDo not use DIP Switch 4. It is set to “OFF” at all times after factory shipments.

38

How to use the Folding Bracket
The 2+ Folding bracket is a retractable type, which can be pushed down while a product is still attached when transporting equipment. (Fixed Position: 90 degrees to the right and 45 degrees to the right and left from an upright direction)

For example, when moving 90 degrees to the right from an upright position.

For example, when moving 45 degrees to the right from an upright position.

Depressing the locking lever on the left side of the Pole releases the bracket to be lowered. (Depressing the lock allows the Pole to swivel freely)

Pole

Pushed down to the left about 15 degrees.

Depressing

Stopper

The Pole can then be pulled forward and pushed down in a clockwise direction.
(From a level plane up to about a 15 degree angle)
Pulled forward and pushed down in a clockwise direction.

The Pole can then be pulled forward and pushed down in a clockwise direction.
(From a level plane up to about a 60 degree angle)
Pulled forward and pushed down in a clockwise direction.

about 15 degrees.

about 60 degrees.

The Pole is pushed down to the right (clockwise). (The Pole is turned until it is latched in place by the locking lever)

1VTIFEEPXOJOBDMPDLXJTFEJSFDUJPO

1VTIFEEPXOJOBDMPDLXJTFEJSFDUJPO

$MJDL

$MJDL
39

8 Unit Detachment Method
Refer to the following diagrams when detaching the buzzer unit, recombining the LED Unit, etc. Also, scan the QR Code to see the “How To” video.
1BUMJUF8FCTJUF
Warning
Be sure the power is disconnected before working on this product.
$BVUJPO
Do not apply excessive strength with each unit or body. Failure to comply may damage the unit. Do not touch the connector area or the inside of the body and LED unit. Failure to comply may damage
the unit. Be sure to lock each unit securely when attaching. Failure to comply may damage the unit. Detach the unit in the following manner. Any other method may result in damaging the product.
Attachment : Attach one unit at a time to the body. Removal : Firmly hold the bottom section while removing the upper section.
/PUJDF
The maximum number of attachment units per product are five LED units, plus one buzzer unit. *LR6-W4, LR6-L4 : Three LED units (Red, Amber, Green) . *LR6-W5, LR6-L5 : Three LED units (Red, Amber, Green) and one buzzer unit.
40

< LED Unit to Body > Removal
Attachment

LED Unit

While holding the body, turn the LED unit counterclockwise, until it unlocks, then pull it upwards to remove.

Positioning Mark <Locked>

<Unlocked>

Body

Align the Positioning Mark after insertion, then turn the unit clockwise to lock it.

Align the Positioning Mark after inserting.

Positioning Mark <Unlocked>

<Locked>

41

< LED Unit to LED Unit > Removal

Body

LED Unit LED Unit

While holding LED unit, turn the LED unit counterclockwise, until it unlocks, then pull it upwards to remove. to remove it.

Positioning Mark <Locked>

<Unlocked>

Attachment

Align the Positioning Mark after insertion, then turn the unit clockwise to lock it.
Align the Positioning Mark after inserting.

Positioning Mark <Unlocked>

<Locked>

42

< Buzzer Unit to LED Unit > Removal

Buzzer Unit

LED Unit LED Unit

While holding LED unit, turn the buzzer unit counterclockwise, until it unlocks, then pull it upwards to remove it.

Positioning Mark <Locked>

<Unlocked>

Body

Attachment

Align the Positioning Mark after insertion, then turn the unit clockwise to lock it.
Align the Positioning Mark after inserting.

Positioning Mark <Unlocked>

<Locked>

43

When the Buzzer Unit will not attach When the Buzzer Unit is detached, the tab and groove are positioned as in the figure below.

Buzzer Unit

Tab

Groove

LED Unit

Positioning Mark

Body

Buzzer Unit Underside View (Removal Buzzer Unit)
When the Buzzer Unit is detached, the tab is located in the groove.

Caution
If the Buzzer Unit cannot attach properly, check that the tab of parts inside the Buzzer Unit are fitted inside the groove. If the tab is outside of the groove as shown below, refer to the next page on how to reposition it. Also, as shown below, tab may come off the groove when removing the Buzzer Unit, depending on how it is removed. If the product is installed again in this condition, it may become damaged.

Groove

Tab Buzzer Unit Underside View

44

If the Buzzer Unit can’t be attached, try the procedure below. Turn the internal part of the Buzzer Unit counterclockwise until the tab fits in the groove. Attach the Buzzer Unit to the product.
Turn this part counterclockwise. Tab Groove
Buzzer Unit Underside View
45

< Head Cover to LED Unit > Removal

Head Cover

While holding the LED unit, turn the head cover counterclockwise until it unlocks, then pull it upwards to remove.

LED Unit

Positioning Mark <Locked>

<Unlocked>

LED Unit

Body

Attachment

Align the Positioning Mark after insertion, then turn the unit clockwise to lock it.

Align the Positioning Mark after inserting.

Positioning Mark <Unlocked>

<Locked>

46

<Unit Replacement Procedure> Decreasing the LED Units

Remove the LED unit located above the unit which is intended to be removed.

While holding the LED unit, turn the LED unit counterclockwise,until it unlocks, then pull it
upwards to remove.

Align the Positioning Mark after insertion, then turn the unit which is removed ( 1 )
clockwise to lock it.

47

Increasing the LED Units

Remove the LED unit located above the unit which is intended to be attached.

Align the Positioning Mark after insertion, then turn the unit clockwise to lock it.

Align the Positioning Mark after insertion, then turn the unit which is removed ( 1 )
clockwise to lock it.

48

Recombining the LED Units

1 Remove the LED unit located above the unit which is intended to be relocated.

2 While holding the LED unit, turn the LED unit counterclockwise until it unlocks, then pull it upwards to remove.

3 Remove the LED unit located above the unit which is intended to be relocated.

4 Align the Positioning Mark after insertion, then turn the unit which is removed ( 2 )
clockwise to lock it.

49

5 Align the Positioning Mark after insertion, then turn the unit which is removed ( 2 ) clockwise to lock it.

6 Align the Positioning Mark after insertion, then turn the unit which is removed ( 1 ) clockwise to lock it.

50

When the LED Unit will not attach The structure of LED Unit is shown in the below figure.
Situation
LED Unit
Positioning Mark

Structure
Lens

Tab is placed in the groove

Body

LED Unit Topside View (Removal LED Unit)

Tab is placed in the groove

When LED Unit is detached, the lens tab is usually located in the groove.

LED Unit Body

Lens

Tab Groove

Positioning Mark

Tab

LED Unit Topside View (Attached LED Unit)

Groove

When LED Unit is attached, the lens tab is usually located out of the groove.

51

Caution
If the LED Unit cannot attach properly, check that the tabs inside the LED Unit are fitted inside the groove. If the tab is outside of the groove as shown below, refer to the next page on how to reposition it. Also, as shown below, tabs may come off the groove when removing the LED Unit, depending on how it is removed. If the product is installed again in this condition, it may become damaged.

Lens

Tab Groove

LED Unit Topside View

Tab Groove

Do not remove it as the improper procedure depicts it below. A condition occurs in which the lens tab is out of the groove. If the product is installed again in this condition, it may become damaged.

When detaching units in the middle.

Hold the upper LED’s firmly and remove the lower LED Unit from the rest.

The lens tab is located out of the groove.

52

If the LED Unit can’t be attached, try the procedure below.
Turn the internal lens of the LED Unit counterlockwise until the tab fits in the groove. Attach the LED Unit to the product.
Lens

LED Unit Underside View Lens

Tab is placed in the groove.

LED Unit Topside View (Attachable)

Tab is placed in the groove.

53

<Body Unit> Removal

Body
A
Direct Mount Bracket

Body

A

A
Direct Mount Bracket

Body A
Pole Bracket

Example:LR7-WTNW

Example:LR6-W4/W5/W8

While holding the direct mount bracket, turn the body counterclockwise until it unlocks, then pull it upwards to remove. Part ‘A’ and the body cannot be separated.

Positioning Mark <Locked>

<Unlocked>

Example:LR6-L4/L5/L8

Attachment

Align the Positioning Mark after inserting.

Example:LR6-W4/W5/W8

Example:LR7-WTNW

Align the Positioning Mark after insertion, then turn the unit clockwise to lock it.

Positioning Mark <Unlocked>

<Locked>

54

Example:LR6-L4/L5/L8

9 Troubleshooting
Prior to contacting your nearest PATLITE Sales Representative, refer to the following tips, and try to solve them in the following table.

No.

Problem

Where to Check

What to do

Is the electric wiring connected correctly?

Refer to ” 5 Wiring” for proper wiring.

1 The LED does not light up. Is the power properly supplying the correct voltage? Check the rated supply voltage.

Is the fuse blown out?

If the fuse is blown out, replace it.

A different LED from what 2 I thought lights up when Is the electric wiring connected correctly?
it turns on.

Refer to ” 5 Wiring” for proper wiring.

Is the electric wiring connected correctly?

Refer to ” 5 Wiring” for proper wiring.

Is the power properly supplying the correct voltage? Check the rated supply voltage.

3 The Buzzer does not sound.
Is the fuse blown out?

If the fuse is blown out, replace it.

Is it the proper product model?

The buzzer function is only included with
products with a ” B ” in the model number.

4 The Buzzer volume is small. Is the Buzzer volume set to minimum?

Refer to ” 6 Buzzer Pattern Set-up” on how to adjust the volume.

5

The Buzzer does not sound Is the sound pattern something other than

immediately.

Continuous Beep Sound?

To sound in conjunction with a buzzer input, use a Continuous Beep Sound.

Is the electric wiring connected correctly?

Refer to ” 5 Wiring” for proper wiring.

6 The LED does not flash.

Are the external contacts for lighting turning on? Is it the proper product model?

Priority is given to the lighting input over the flashing input when simultaneous signals are applied.
The flash function is only included with
products with a ” B ” in the model number.
*Excluding LR6-W5/W8 and LR6-L5/L8.

If the problem is not resolved after doing the procedure as above, refer to the end of this document for the contact information and contact the nearest PATLITE Sales Representative.

Product Details

Product Name

Signal Tower

Purchase Date

Model Number ( 2 Model Number Configuration )

Situation of Failure

/

/

with as much detail as possible

55

10 Specifications

General Specifications 02 WJ LJ PJ QJ WT KT

Model Rated Voltage

LR-02 24V DC

Operating Voltage Range

Signal Wire Current Per Unit

Typ. Max.

Power Supply Wire Inrush Current Signal Wire

Rated Power Consumption Per Unit

Typ. Max.

Standby Power Consumption
Operating Ambient Temperature Operating Ambient Humidity Storage Ambient Temperature Storage Ambient Humidity Mounting Location

Rated Voltage ±10%
LED Unit40mA Buzzer Unit40mA (1)
LED Unit45mA Buzzer Unit250mA (1) none (Signal Wire Current Maximum not exceeding the sum total)
LED Unitnone Buzzer Unitnone (Not exceeding Maximum Signal Wire Current Ratings)
LED Unit 1W Buzzer Unit 1W (1)
LED Unit 1.3W Buzzer Unit 1.3W (1)
LED Unit none Buzzer Unit 0.1W Body Unit none
-20^ +50^ Less than 90% RH (No Condensation)
-30^ +60^ Less than 90% RH (No Condensation)
Indoor Only

Mounting Direction

Upright IP65(IEC 60529) / NEMA TYPE 4X,13

Protection Rating
Environmental Condition Insulation Resistance
Withstand Voltage Flashing Rate

LJ

IP54(IEC 60529) / NEMA TYPE 4X,13

KT

IP65(IEC 60529) / NEMA TYPE 4X,13

When using POLE22-AT : IP54(IEC 60529) / NEMA TYPE 4X,13

Upright

More than 1M at 500VDC between live part and non-current carrying metallic part

500VAC applied for 1min between live part and non-current carrying metallic part without breaking insulation

60±2 Flashes Per Minute

Buzzer Sound/ Typical Frequency

No.1 No.2

Rapid Intermittent Beep / 3378Hz Continuous Beep Sound / 3378Hz

No.3 No.4

Rapid Hi-Lo / 2016Hz&3012Hz Sweep Sound / 1000Hz-4032Hz

Setting Outer Dimensions

Depending on DIP Switch settings.Refer to Section 6 “Buzzer Pattern Set-up”.

Refer to Section 3 “Part Names and Outer Appearance”

(LED Unit) + [Buzzer Unit]

WJ Off-white 0.17kg + (0.035kg)×Tiers + [0.035kg] Silver 0.32kg + (0.035kg)×Tiers + [0.035kg]

LJ Off-white 0.46kg + (0.035kg)×Tiers + [0.035kg] Silver 0.61kg + (0.035kg)×Tiers + [0.035kg]

LR4

PJ Off-white 0.36kg + (0.035kg)×Tiers + [0.035kg] Silver 0.51kg + (0.035kg)×Tiers + [0.035kg]

QJ Off-white 0.42kg + (0.035kg)×Tiers + [0.035kg]

Mass (Tolerance ±10%)
Sound Pressure Level

WJ Off-white 0.20kg + (0.040kg)×Tiers + [0.050kg]

Off-white 0.10kg+ (0.040kg)×Tiers + [0.050kg]

LR5

LJ Off-white 0.49kg + (0.040kg)×Tiers + [0.050kg] WT

Silver/Black

0.10kg

PJ Off-white 0.38kg + (0.040kg)×Tiers + [0.050kg] KT Off-white/Silver/Black

0.10kg

WJ Off-white 0.22kg + (0.060kg)×Tiers + [0.060kg] Silver 0.35kg + (0.060kg)×Tiers + [0.060kg]

LR6

LJ Off-white 0.50kg + (0.060kg)×Tiers + [0.060kg] Silver 0.64kg + (0.060kg)×Tiers + [0.060kg] PJ Off-white 0.40kg + (0.060kg)×Tiers + [0.060kg] Silver 0.53kg + (0.060kg)×Tiers + [0.060kg]

QJ Off-white 0.46kg + (0.060kg)×Tiers + [0.060kg]

LR7 WJ Off-white 0.24kg + (0.065kg)×Tiers + [0.070kg] KT Off-white/Silver/Black

WT Off-white/Silver/Black

0.15kg

0.15kg

LR4

Typical 85dB

LR5

Typical 85dB

LR6

Typical 88dB

LR7

Typical 90dB

Sound Reduction approximately -10dB, depending on DIP Switch settings. Refer to Section 6 “Buzzer Pattern Set-up”

Environmental Condition

Buzzer sound No.4 was measured from the total circumfrence of the Buzzer Unit at 1m

Conformity Standards Remarks

UL 508, CSA-C22.2 No. 14, EMC Directive (EN 61000-6-4, EN 61000-6-2)
RoHS Directive (EN IEC 63000), FCC Part 15 Subpart B Class A KC (KN 61000-6-4, KN 61000-6-2) (2)
(1) Environmental Condition: Buzzer Sound No.2 (Continuous Beep Sound) (2) Except KT, Assembly Model WT Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness of every product may occur. UL Recognized Component (File No.E215660)

This product is designed for use on a flat surface for a Type 1 Enclosure. (Conformity requirements for UL Standard) Use a “class 2” power supply specified in the guidelines under UL1310. (Conformity requirements for UL Standard) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These restrictions are limited to cases where this equipment is operated in a business district, and it is designed to take the relevant protective measures against electromagnetic noise hindrance.
This product must not be used in residential areas. (Conformity requirements for the CE Marking)

56

General Specifications 02 WC WM

Model

Rated Voltage

Operating Voltage Range

Signal Wire Current

Typ.

Per Unit

Max.

Rated Power Consumption Typ.

Per Unit

Max.

Operating Ambient Temperature Operating Ambient Humidity

Storage Ambient Temperature Storage Ambient Humidity

Mounting Location

Mounting Direction

Protection Rating Environmental Condition

Insulation Resistance

Withstand Voltage

Outer Dimensions

Mass(Tolerance ±10%)

Conformity Standards

Remarks

LR-02WNW 24V DC
Rated Voltage ±10% LED Unit40mA LED Unit45mA LED Unit 1W LED Unit 1.3W -20^ +50^
Less than 90% RH (No Condensation) -30^ +60^
Less than 90% RH (No Condensation)
Indoor Only
Upright IP65(IEC 60529) / NEMA TYPE 4X,13
Upright More than 1M at 500VDC between live part and non-current carrying metallic part
500VAC applied for 1min between live part and non-current carrying metallic part without breaking insulation Refer to Section 3 “Part Names and Outer Appearance”
LR4-02WCNW0.09kg LR6-302WCNW0.35kg LR6-02WCNW0.17kg LR6-02WMNW0.21kg UL 508, CSA-C22.2 No. 14, EMC Directive (EN 61000-6-4, EN 61000-6-2) RoHS Directive (EN IEC 63000), FCC Part 15 Subpart B Class A KC (KN 61000-6-4, KN 61000-6-2)
UL Recognized Component (File No.E215660) Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness of every product may occur.

This product is designed for use on a flat surface for a Type 1 Enclosure. (Conformity requirements for UL Standard)
Use a “class 2” power supply specified in the guidelines under UL1310. (Conformity requirements for UL Standard)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These restrictions are limited to cases where this equipment is operated in a business district, and it is designed to take the relevant protective measures against electromagnetic noise hindrance.
This product must not be used in residential areas. (Conformity requirements for the CE Marking)

57

General Specifications 02 W4/W5/W8

Model Rated Voltage Operating Voltage Range

Rated Current Consumption

Typ. Max.

Rated Current Consumption

Typ. Max.

Operating Ambient Temperature Operating Ambient Humidity Storage Ambient Temperature Storage Ambient Humidity Mounting Location Mounting Direction Protection Rating Environmental Condition Insulation Resistance Withstand Voltage
Mass (Tolerance ±10%)

Sound Pressure Level Environmental Condition

LR-02W(4/5/8) 24V DC

Rated Voltage ±10%

LED Unit40mA
Buzzer Unit40A1 LED Unit45mA
Buzzer Unit250A1 LED Unit 1W
Buzzer Unit1W1 LED Unit 1.3W
Buzzer Unit1.3W1 -20^ to +50^
Less than 90 % (No condensation)

-30^ to +60^ Less than 90 % (No condensation)

Indoor

Upright IP65 (IEC 60529)

Upright

More than 1M at 500V DC between live part and non-current carrying metallic part

500V AC applied for 1min between live part and non-current carrying metallic part without breaking insulation (LED Unit) + [Buzzer Unit] 0.17kg + (0.06kg) ×Tiers + [0.06kg]

Typ.88dB

Sound Reduction Approx. -10dB Depending on Dip Switch Settings Refer to the 6. Buzzer Pattern Set-up

Buzzer sound No.4 was measured from the total circumfrence of the Buzzer Unit at 1m

Conformity Standards

UL 508, CSA-C22.2 No. 14 RoHS Directive (EN IEC 63000) EMC Directive (EN 61000-6-4, EN 61000-6-2) FCC Part 15 SubpartB Class A KC (KN 61000-6-4, KN 61000-6-2)

Remarks

(1) Environmental Condition: Buzzer Sound No.2 (Continuous Beep Sound) Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness of every product may occur.
UL Recognized Component (File No.E215660)

This product is designed for use on a flat surface for a Type 1 Enclosure. (Conformity requirements for UL Standard)
Use a “class 2” power supply specified in the guidelines under UL1310. (Conformity requirements for UL Standard)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These restrictions are limited to cases where this equipment is operated in a business district, and it is designed to take the relevant protective measures against electromagnetic noise hindrance.
This product must not be used in residential areas. (Conformity requirements for the CE Marking)

58

General Specifications 02 L4/L5/L8

Model Rated Voltage Operating Voltage Range

Rated Current Consumption

Typ. Max.

Rated Current Consumption

Typ. Max.

Operating Ambient Temperature Operating Ambient Humidity Storage Ambient Temperature Storage Ambient Humidity Mounting Location Mounting Direction Protection Rating Environmental Condition Insulation Resistance Withstand Voltage
Mass (Tolerance ±10%)

Sound Pressure Level Environmental Condition

LR-02L(4/5/8) 24V DC

Rated Voltage ±10%

LED Unit40mA
Buzzer Unit40A1 LED Unit45mA
Buzzer Unit250A1 LED Unit 1W
Buzzer Unit1W1 LED Unit 1.3W
Buzzer Unit1.3W1 -20^ to +50^
Less than 90% RH (No condensation)

-30^ to +60^ Less than 90% RH (No condensation)

Indoor

Upright IP54 (IEC 60529)

Upright

More than 1M at 500V DC between live part and non-current carrying metallic part

500V AC applied for 1min between live part and non-current carrying metallic part without breaking insulation (LED Unit) + [Buzzer Unit] 0.47kg + (0.06kg) ×Tiers + [0.06kg]

Typ.88dB

Sound Reduction Approx. -10dB Depending on Dip Switch Settings Refer to the 6. Buzzer Pattern Set-up

Buzzer sound No.4 was measured from the total circumfrence of the Buzzer Unit at 1m

Conformity Standards

UL 508, CSA-C22.2 No. 14 RoHS Directive (EN IEC 63000) EMC Directive (EN 61000-6-4, EN 61000-6-2) FCC Part 15 SubpartB Class A KC (KN 61000-6-4, KN 61000-6-2)

Remarks

(1) Environmental Condition: Buzzer Sound No.2 (Continuous Beep Sound) Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness of every product may occur.
UL Recognized Component (File No.E215660)

This product is designed for use on a flat surface for a Type 1 Enclosure. (Conformity requirements for UL Standard)
Use a “class 2” power supply specified in the guidelines under UL1310. (Conformity requirements for UL Standard)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These restrictions are limited to cases where this equipment is operated in a business district, and it is designed to take the relevant protective measures against electromagnetic noise hindrance.
This product must not be used in residential areas. (Conformity requirements for the CE Marking)

59

General Specifications 01

Model

LR5-01W

Rated Voltage

12V DC

Operating Voltage Range

Rated Voltage ±10%

Signal Wire Current Per Unit

Typ. Max.

Power Supply Wire Inrush Current
Signal Wire

LED Unit90mA Buzzer Unit90mA (1)
LED Unit100mA Buzzer Unit250mA (1)
0.7A / Less than 15ms LED Unitnone (2) Buzzer Unitnone (Not exceeding Maximum Signal Wire Current Ratings) (2)

Rated Power Consumption Per Unit

Typ. Max.

LED Unit 1W Buzzer Unit 1.1W (1)
LED Unit 1.1W Buzzer Unit 1.2W (1)
LED Unit none

Standby Power Consumption

Buzzer Unit 0.3W

Operating Ambient Temperature Operating Ambient Humidity

Body Unit 0.1W -20^ +50^
Less than 90% RH (No Condensation)

Storage Ambient Temperature Storage Ambient Humidity

-30^ +60^ Less than 90% RH (No Condensation)

Mounting Location

Indoor Only

Mounting Direction

Upright

Protection Rating LJ

IP65(IEC 60529) / NEMA TYPE 4X,13 IP54(IEC 60529) / NEMA TYPE 4X,13

Environmental Condition

Upright

Insulation Resistance

More than 1M at 500VDC between live part and non-current carrying metallic part

Withstand Voltage

500VAC applied for 1min Between live part and non-current carrying metallic part without breaking insulation

Flashing Rate

60±2 Flashes Per Minute

Buzzer Sound/ Typical Frequency

No.1 No.2

Rapid Intermittent Beep / 3378Hz Continuous Beep Sound / 3378Hz

No.3 No.4

Rapid Hi-Lo / 2016Hz&3012Hz Sweep Sound / 1000Hz-4032Hz

Setting

Depending on DIP Switch settings.Refer to Section 6 “Buzzer Pattern Set-up”.

Outer Dimensions

Refer to Section 3 “Part Names and Outer Appearance”

Mass

WJ

(Tolerance ±10%)

LJ

(LED Unit) + [Buzzer Unit] 0.2kg + (0.04kg)×Tiers + [0.05kg] 0.49kg + (0.04kg)×Tiers + [0.05kg]

PJ

0.38kg + (0.04kg)×Tiers + [0.05kg]

Sound Pressure Level

Typ.80dB

Sound Reduction approximately -10dB, depending on DIP Switch settings. Refer to Section 6 “Buzzer Pattern Set-up”

Environmental Condition

Buzzer sound No.4 was measured from the total circumference of the Buzzer Unit at 1m

Conformity Standards

UL 508, CSA-C22.2 No. 14, EMC Directive (EN 61000-6-4, EN 61000-6-2) RoHS Directive (EN IEC 63000), FCC Part 15 Subpart B Class A KC (KN 61000-6-4, KN 61000-6-2)

Remarks

(1) Environmental Condition: Buzzer sound No.2 (Continuous Beep Sound) (2)When (Gray) power supply wire is not connected, inrush current or 0.7A will flow through the
signal wires. Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness
of every product may occur.
UL Recognized Component (File No.E215660)

This product is designed for use on a flat surface for a Type 1 Enclosure. (Conformity requirements for UL Standard)

Use a “class 2” power supply specified in the guidelines under UL1310. (Conformity requirements for UL Standard)

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These restrictions are limited to cases where this equipment is operated in a business district, and it is designed to take the
relevant protective measures against electromagnetic noise hindrance.

This product must not be used in residential areas. (Conformity requirements for the CE Marking)

60

General Specifications M2

Model

LR-M2W

Rated Voltage

100-240V AC (50/60Hz)

Operating Voltage Range

90-250V AC (50/60Hz)

Signal Wire Current Per Unit

Typ. Max.

Inrush Current Power Supply Wire

LED Unit 40mA Buzzer Unit 40mA (1)
LED Unit 45mA Buzzer Unit 250mA (1) at 25^25A/ Less than 2ms (Cold-start) at 50^50A/ Less than 2ms (Cold-start)

Signal Wire

none

Rated Power Consumption Per Unit

Typ. Max.

Standby Power Consumption

LED Unit 1.5W Buzzer Unit 1.5W (1)
LED Unit 1.8W Buzzer Unit 1.8W (1)
LED Unit none Buzzer Unit 0.2W

Operating Ambient Temperature Operating Ambient Humidity

Body Unit 0.2W -20^ +50^
Less than 90% RH (No Condensation)

Storage Ambient Temperature Storage Ambient Humidity

-30^ +60^ Less than 90% RH (No Condensation)

Mounting Location

Indoor Only

Mounting Direction

Upright

Protection Rating LJ

IP65(IEC 60529) / NEMA TYPE 4X,13 IP54(IEC 60529) / NEMA TYPE 4X,13

Environmental Condition

Upright

Insulation Resistance Withstand Voltage

More than 1M at 500VDC between live part and non-current carrying metallic part 1500VAC applied for 1min Between live part and non-current carrying metallic part without breaking insulation

Flashing Rate

60±2 Flashes Per Minute

Buzzer Sound/ Typical Frequency

No.1 No.2

Rapid Intermittent Beep / 3378Hz Continuous Beep Sound / 3378Hz

No.3 No.4

Rapid Hi-Lo / 2016Hz&3012Hz Sweep Sound / 1000Hz-4032Hz

Setting Outer Dimensions

Depending on DIP Switch Settings.Refer to Section 6 “Buzzer Pattern Set-up”. Refer to Section 3 “Part Names and Outer Appearance”

(LED Unit) + [Buzzer Unit]

Mass (Tolerance ±10%)
Sound Pressure Level

WJ LR4 LJ
PJ WJ LR6 LJ PJ
LR4 LR6

Typ.85dB Typ.88dB

LH LH
5JFST<LH>
LH LH
5JFST<LH> LH LH
5JFST<LH>
LH LH
5JFST<LH>
LH LH
5JFST<LH> LH LH
5JFST<LH>
Sound Reduction approximately -10dB, depending on DIP Switch settings. Refer to Section 6 “Buzzer Pattern Set-up”

Environmental Condition

Buzzer sound No.4 was measured from the total circumference of the Buzzer Unit at 1m

Conformity Standards

UL 508, CSA-C22.2 No. 14, EMC Directive (EN 61000-6-4, EN 61000-6-2) RoHS Directive (EN IEC 63000), FCC Part 15 Subpart B Class A
KC (KN 61000-6-4, KN 61000-6-2) (2), Low Voltage Directive(IEC/EN60947-5-1,EN62471)(2)

Remarks

(1) Environmental Condition: Buzzer sound No.2 (Continuous Beep Sound) (2) Except LJ Type Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness
of every product may occur.
UL Recognized Component (File No.E215660)

When a regulated power supply is not being used, select a fuse that meets class CC or more.

Use a fuse holder with UL standard certification. (Conformity requirements for UL Standard)

This product is designed for use on a flat surface for a Type 1 Enclosure. (Conformity requirements for UL Standard)

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These restrictions are limited to cases where this equipment is operated in a business district, and it is designed to take the
relevant protective measures against electromagnetic noise hindrance.

This product must not be used in residential areas. (Conformity requirements for the CE Marking)

61

11 Replacement Parts

The following replacement parts for this product are available for the customer to change or replace.

O-ring 40

Replacement Parts for LR4

Head Cover 40 [W/U]

Pole Bracket 40 [W/U]

Filter Sheet 40

O-ring 50

5 pcs.

Accessories:

O-ring 40

1 pc.

Pole Waterproof Ring 1 pc.

Binding Head Tapping Screw 2 pcs.

Replacement Parts for LR5

Head Cover 50 [W/U/K]

Pole Bracket 50 [W/U/K]

Filter Sheet 50

5 pcs.

O-ring 60

5 pcs.

Accessories:

O-ring 50

1 pc.

Pole Waterproof Ring 1 pc.

Binding Head Tapping Screw 2 pcs.

Replacement Parts for LR6

Head Cover 60 [W/U]

Pole Bracket 60 [W/U]

Filter Sheet 60

5 pcs.

5 pcs.

Accessories:

O-ring 60

1 pc.

Pole Waterproof Ring 1 pc.

Binding Head Tapping Screw 2 pcs.

Not compatible with

LR6-W4/W5/W8 and LR6-L4/L5/L8.

5 pcs.

62

O-ring 70

Replacement Parts for LR7

Head Cover 70 [W/U/K]

Pole Bracket 70 [W/U/K]

Filter Sheet 70

5 pcs.
Replacement Parts for 8 5
Terminal Block

Accessories:

O-ring 70

1 pc.

Pole Waterproof Ring 1 pc.

Binding Head Tapping Screw 2 pcs.

Replacement Parts for LR4/LR5/LR6/LR7 Pole Waterproof Ring

5 pcs.

Replacement Parts for 8 $ 8 8 8
M30 Hexagon Nut [W]

Replacement Parts for LR4 8 $
Waterproof Packing

Replacement Parts for LR6 8$ 888
NPT Pole Bracket Assy 60 [W]

63

12 Optional Parts
The following optional parts are available for this product. (Upper : Product Name , Lower : Model)

LED Unit LR< 4/5/6/7 > – E

Model Number Configuration

Model

LED Unit Color Globe Color

LED Unit LR E

Outer Dimensions
6OJU: mm (10)
40
LR4:40 , LR5:50 LR6:60 , LR7:70

4 6 40

60

5 7 50

70

R Y Red

Amber

G B Green

Blue

1LR 6- Z

C White

2 L R456

M Multi Color

3 CannotCFVTFEXJUI L R6 -W4 W5 L4 L5

(None)Color Globe

Z Clear Globe2

General Specifications

Model

Operating Ambient Temperature

Operating Ambient Humidity

LR4

Mass

LR5

Tolerance ±10 LR6

LR7

Remarks

LR-E- -20^ +50^ Less than 90% RH (No Condensation)
0.035kg
0.040kg
0.060kg
0.065kg
Due to the characteristics of the LED elements, a variation in difference of the color tone and brightness of every product may occur.
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

64

Buzzer Unit 1 LR[ 4/5/6/7 ] – B[W/U/K] 0VUFS%JNFOTJPOT
6OJU: mm
53.5
LR4:40 , LR5:50 LR6:60 , LR7:70

Model Number Configuration

Model

Body Color

Buzzer Unit LR B

4 6 40

60

5 7 50

70

1Cannnot be used with LR6 -W4 L4
2L R 567

W Off-white U Silver K Black

(FOFSBM4QFDJpDBUJPOT

Model Operating Ambient Temperature

Operating Ambient Humidity

LR4

Mass

LR5

Tolerance ±10

LR6

LR7

Buzzer Sound/ Typical Frequency

No.1 No.2 No.3 No.4 LR4

LR5 Sound Pressure Level LR6

LR7

Environmental Condition

Remarks

LR-B -20^ +50^ Less than 90% RH (No Condensation)
0.035kg

0.050kg

0.060kg

0.070kg

Rapid Intermittent Beep/ 3378Hz

Continuous Beep Sound/ 3378Hz

Rapid Hi-Lo/ 2016Hz&3012Hz

Sweep Sound/ 1000Hz-4032Hz

Typ.85dB Typ.85dB (Typ.80dB)
Typ.88dB Typ.90dB

Sound Reduction approx. -10dB, depending on DIP Switch settings. Refer to Section 6 “Buzzer Pattern Set-up”

Buzzer sound No.4 was measured from the total circumference of the buzzer Unit at 1m

When LR5-01(12V DC type) is attached.
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

65

Circular Bracket SZP-001W
Accessories: Waterproof Packing Pole Waterproof Ring Binding Head Tapping Screw (2 pcs.)
Outer Dimensions
6OJU: mm

Pole 21.7
(29)

70

50 (21)

Model Number Configuration

Model

Body Color

Circular Bracket SZP – 001

W Off-white
Compatible Models
LR4 – PJ QJ , LR5 – PJ KT 1 LR6 – PJ QJ , LR7 – KT 1
(1)3FRVJSFEQPMFJTOPUJODMVEFEXJUIKT

Compatible Pole

POLE22-0100AN,POLE22-0300AN POLE22-0100ANK,POLE22-0300ANK

Specifications

Model

SZP-001W

Mounting Location

Indoor Only

Protection Rating

IP65 (with product attached)

Material

PC

Mass (Tolerance ±10%) No Accessories

0.04kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Note It’s possible to run a cable out from the side.

Mounting Dimensional Drawing

S Z P – 001 WMounting Dimensional Drawing

(Unit : mm) 90°

Mounting Hole (5×3 places)

Mounting Hole (5×4 places)

5456 4050

120°

Screw/Nut M4

Recommended Torque

Wire Distribution

0.6 N m

Hole (12)

66

Pole Installation

1. Install the Pole Waterproof Ring in the Circular Bracket. Check that the 2 ribs are on the outside.

Pole

2. Insert Pole into the Circular Bracket. See the figure on the left for details on the direction of insertion.

Pole Waterproof Ring

3. Tighten the Binding Head Tapping Screws (2 pcs.) from underneath the Circular Bracket.
4. Put the Waterproof Packing on the bottom of Circular Bracket.

Circular Bracket

Notice Installation using materials other than the specified accessories is not covered under warranty.

Binding Head Tapping Screw 3×122 pcs.
Recommended Torque
0.8 N m

Waterproof Packing Secure with double-sided tape

Cutting a side-hole for cable (Procedure) Take a cable out from a sideProcessing Method
This part has perforations to make it possible to run a cable out from the side.

1. Refer to the enlarged drawing and cut the outlined part of the bracket. Cut in two places with nippers.

2. Break off the outlined part with pliers. If there are burrs, carefully remove with plyers or a file.

Enlarged Drawing

67

Circular Bracket SZP-002U
Accessories: Pole Waterproof Ring Binding Head Tapping Screw (2 pcs.)
Outer Dimensions
6OJU: mm

Model Number Configuration

Model

Body Color

Circular Bracket SZP – 002 U

U Silver
Compatible Models
LR4 – PJ QJ , LR5 – PJ KT 1 LR6 – PJ QJ , LR7 – KT 1
(1)3FRVJSFEQPMFJTOPUJODMVEFEXJUIKT

Compatible Pole
POLE22-0100AN,POLE22-0300AN POLE22-0500AN,POLE22-0800AN POLE22-1000AN POLE22-0100ANK,POLE22-0300ANK POLE22-0800ANK

Specifications

Model Mounting Location

SZP-002U Indoor Only

Protection Rating Material

IP20 (with product attached) ADC12

Mass (Tolerance ±10%) No Accessories
Remarks

0.11kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Note It’s possible to run a cable out from the side.

Pole 21.7
(29)

94

43 (21)

Mounting Dimensional Drawing
S Z P – 0 0 2 U Mounting Dimensional Drawing
(Unit : mm) 90°
Mounting Hole (5×4 places) Mounting Hole (5×4 places)

54~56
73
Wire Distribution Hole (12)

Screw/Nut M4

Recommended Torque 0.6 N m

68

Pole Installation

1. Install the Pole Waterproof Ring in the Circular Bracket. Check that the 2 ribs are on the outside.

Pole
2. Insert Pole into the Circular Bracket. See the figure on the left for details on the direction of insertion.
3. Tighten the Binding Head Tapping Screws (2 pcs.) from underneath the Circular Bracket.
Pole Waterproof Ring

Circular Bracket

Notice Installation using materials other than the specified accessories is not covered under warranty.

Binding Head Tapping Screw 3×122 pcs. Recommended Torque
0.8 N m
Running a cable out from the side-hole
This part has perforations to make it possible to run a cable out from the side. Refer to the diagram below and run the cable where the arrow indicates the outlet.

69

Circular Bracket SZP-003 [W/U/K] Accessories: Waterproof Packing Pole Waterproof Ring Binding Head Tapping Screw (2 pcs.)
Outer Dimensions
6OJU: mm

Pole 21.7
(29)

60

35 6

Model Number Configuration

Model

Body Color

Circular Bracket SZP – 003

W Off-white U Silver K Black
Compatible Models
LR4 – PJ QJ , LR5 – PJ KT 1 LR6 – PJ QJ , LR7 – KT 1
(1)3FRVJSFEQPMFJTOPUJODMVEFEXJUIKT

Compatible Pole
POLE22-0100AN,POLE22-0300AN POLE22-0100ANK,POLE22-0300ANK

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZP-003<86,> Indoor Only
IP65 (with product attached PC
0.03kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

SZP-003[W/U/K] Mounting Dimensional Drawing

(Unit: mm)

Mounting Hole (5×3places) 120°

120°

40

Screw/Nut M4

Recommended Torque

Wire Distribution

0.6 N m

Hole (12)

70

Pole Installation

1. Install the Pole Waterproof Ring in the Circular Bracket. Check that the 2 ribs are on the outside.

Pole

2. Insert Pole into the Circular Bracket. See the figure on the left for details on the direction of insertion.
3. Tighten the Binding Head Tapping Screws (2 pcs.) from underneath the Circular Bracket.
4. Put the Waterproof Packing on the bottom of Circular Bracket.

Pole Waterproof Ring
Circular Bracket

Notice Installation using materials other than the specified accessories is not covered under warranty.

Binding Head Tapping Screw 3×122 pcs.
Recommended Torque
0.8 N m
Waterproof Packing (Place it into Circular Bracket)

71

Pole Bracket SZP-004 [W/U/K]

Accessories: Pole Ring Tapping Screw (2 pcs.)

Outer Dimensions
6OJU: mm
60

35
21.5 Insertion depth of pole

(29)
Pole 21.7

Model Number Configuration

Model

Body Color

Circular Bracket SZP – 004

Compatible Models
LR6- WM

W Off-white U Silver K Black

Compatible Pole
POLE-100A21,POLE-300A21,POLE-800A21

Specifications

Model Mounting Location
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZP-004<86,> Indoor Only ADC12
0.06kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

120°

120°

40

3-4.2

72

Pole Bracket Installation

1. Insert the supplied pole ring into the Pole Bracket.

Slanting

Pole ring

Pole ring Insert direction

Pole Bracket

2. Assemble the pole and Pole Bracket. (Refer to “Assembling the Pole and Pole Bracket”) 3. Pass the cable from the side of the Pole Bracket. 4. Pull out the cable from the side of the pole landmark.
Cable
Pole Bracket Pole
Landmark

Assembling the Pole and Pole Bracket
Insert the pole into the Pole Bracket, lining up the
indentations.
In two positions, use the tapping screws secure the
Pole Bracket and pole. (Recommended torque: 1.4Nm)

Tapping screws

Front side

Tapping screws

Pole Bracket
Pole

Pole Bracket

Front side

Pole Bracket
Line up the indented sections

Landmark Pole

When using M12 cable, one side must be a lead wire.

5. In 3 places, affix the nuts included with the Compatible Models, to secure the Pole Bracket and unit.
Compatible Models

Pole Bracket

Nut with Flange (M4) Recommended Torque
0.6 N m
73

Upper Bracket SZP-005W

Model Number Configuration

Model

Body Color

Upper Bracket SZP – 005 W

W Off-white

Accessories: Sealing Rubber (For 25mm Pole, Gray)

Compatible Models
LR4 – WC

Outer Dimensions
6OJU: mm
40 47 (48.5)

Compatible Pole
22POLE-300SAT, POLE-100A21,POLE-300A21,POLE-800A21

Specifications

Model Mounting Location Protection Rating
Environmental Condition Material Mass (Tolerance ±10%) No Accessories
Remarks

SZP-005W Indoor Only IP65(IEC 60529) / NEMA TYPE 4X,13
Upright
PC 0.03kg (Includes one Sealing Rubber) There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

41

Sealing Rubber (For 22mm Pole, Black)

74

Upper Bracket Installation
1. Loosen and remove Upper Bracket B from Upper Bracket A. 4. Tighten Upper Bracket B into Upper Bracket A.

Upper Bracket A

Upper Bracket A

There may be a small gap left between the brackets after tightening. (Be sure that the gap is no larger than 1.5mm.)

Upper Bracket B
2. Push the Sealing Rubber (included with product) into Upper Bracket A. (The Sealing Rubber for 22mm Pole, Black is pre-installed onto Upper Bracket A.)

Upper Bracket B

(This side up) Sealing Rubber (For 22mm Pole, Black)

Pole

Dip

Sealing Rubber (No direction) (For 25mm Pole, Gray)

5. Pass the M12 Connector Cable through the Upper
Bracket and Pole,connect the M12 Connector Cable to theLR4-WC(), then tighten the LR4 – WC to the Upper Bracket ().

LR4 – WC

3. Slide the Pole through Upper Bracket B and insert the top end of the Pole into the Sealing Rubber.
Push the Pole in until it reaches the bottom of Upper Bracket A.

Upper Bracket A Sealing Rubber

Upper Bracket A

Upper Bracket B

Pole
If the Pole does not
reach the bottom of Upper Bracket A, it is not installed correctly.

M12 Connector Cable

Upper Bracket
Pole

Upper

Pole

Bracket A

Secure the Waterproof Packing into place. (The Waterproof Packing is pre-installed onto theLR4- WC .)
Waterproof Packing

Pole
75

Grommet SZP-006

Model Number Configuration
Model
Grommet SZP – 006

Outer Dimensions
6OJU: mm
15 3.1
8
20.8

Compatible Models
LR4 – WC LR6 – L4-/L5/L8
Compatible Pole
22POLE-300SAT

Specifications

Model Mounting Location
Material
Remarks

SZP-00 Indoor Only Silicone Sponge
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Installation Figure
Pass the M12 Connector Cable through the Grommet, then insert the Cable and Grommet into the Pole while compressing the Grommet for easier insertion.

Pole
Grommet M12 Connector Cable

76

NPT Bracket SZP-090U

Model Number Configuration

Model

Body Color

Circular Bracket SZP – 090 U

U Silver

Accessories:Screw-tapped spacer (3 pcs.)

Compatible Models
LR4 – WJ , LR5 – WJ WT KT 1
(1)KTDirect Mount

Outer Dimensions
6OJU: mm 15
Product Mounting Hole 3 places
40

Specifications

Model

SZP-090U

Mounting Direction

Upright

Mounting Location Material

Indoor Only AL

Mass (Tolerance ±10%) No Accessories

0.05kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

22 15
36

3-7

1/2” NPT Internal Threads

77

NPT Bracket SZP-091U
Outer Dimensions
6OJU: mm 15

Model Number Configuration

Model

Body Color

Circular Bracket SZP – 091 U

U Silver

Compatible Models
LR6 – WJ , LR7 – WJ WT KT 1
(1)KTDirect Mount

Specifications

Model Mounting Direction Mounting Location
Material

SZP-091U Upright
Indoor Only AL

Mass (Tolerance ±10%)

0.09kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Product Mounting Hole 3 places
60

28 3-11

30 17
1/2” NPT Internal Threads

24

78

Product Attachment

1. Insert the mounting screws of the product into the NPT Bracket. See the figure on the left for details on the direction of insertion.
2. Secure the product from underneath the NPT Bracket. (Used the screw-tapped spacer (3pcs.) for SZP-090U and the franged nut (3 pcs.) for SZP-091U.)
Recommended Torque 0.6 N m
3. Insert pole (1/2”NPT) into the NPT Bracket. (Required pole is not included.)
Notice Installation using materials other than the specified accessories is not covered under warranty.

NPT Bracket (SZP-090U)
Screw-tapped spacer (3 pcs.)
Pole 1/2”NPT

NPT Bracket (SZP-091U)
Flanged nut (3 pcs.) (Accessory of Signal Tower)

79

Pole-compatible Adaptor SZP-917U

Model Number Configuration

Model

Body Color

Pole-compatible Adaptor SZP – 917 U

Accessories: Plain Washer 1 pc.
Hexagon Nut 1 pc.
Hexagon Socket Set Screw (2 pcs.)

Outer Dimensions
6OJU: mm 30

A

A

2-M4

90°

6

23.7 22.2

U Silver

Compatible Models
LR4- LJ ,LR5- LJ ,LR6- LJ

Compatible Pole
POLE22-0100AT,POLE22-0300AT POLE22-0500AT,POLE22-0800AT POLE22-1000AT

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZP-917U Indoor Only IP20 (with product attached
AL
0.05kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing
SZP-917UMounting Dimensional Drawing
(Unit: mm) 2

46

43

27

15 82

Mounting Hole 18)

M17×1.5

(32)

10.3

Effective threaded screw length

Nut M17

Recommended Torque 30 N m

80

Pole-compatible Adaptor Installation
6OJU: mm

Pole

1 . Run the wiring through the the Pole-compatible Adaptor.
Insert the Pole into the Pole-compatible Adaptor. 2 . Secure the Pole with the Hexagon Socket Set Screws
(2 pcs.) on the pole-compatible adaptor.

Pole-compatible Adaptor
Hexagon Socket Set Screw (2 pcs.)

3 . Run the wiring through the mounting hole. While holding part “A”, secure the Pole-compatible Adaptor with included Plain Washer and Hexagon Nut.
Recommended Torque 30 N m

A

A

Installation using materials other than the specified

Mounting Hole

Notice

accessories is not covered under warranty. When the Pole-compatible Adaptor is installed,

do not hold the product and the pole.

Plain Washer Hexagon Nut
Opposite Side 23

81

L-bracket SZL-001

Outer Dimensions

22.5

6OJU: mm

(R20) 32

(5)
5 20
55 75

2-11 9

3

(R20)

Compatible Models

LR4 – LJ , LR5 – LJ KT 1 LR6 – LJ L4/L5/L8 , LR7 – KT 1
(1)3FRVJSFEQPMFJTOPUJODMVEFEXJUIKT

Compatible Pole POLE22-0100AT POLE22-0300AT,POLE22-0500AT POLE22-0800AT,POLE22-1000AT
Specifications

Model Mounting Location
Material Mass (Tolerance ±10%)
Remarks

SZL-001 Indoor Only
SPHC-P 0.09kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Installation Figure
1 Make holes for the mounting for the product. 2 Run the wiring through the distribution hole. 3 Secure the product with the bolts, nuts and screws.

SZL-001 Installation Figure
Unit: mm
23
Feed the wiring through the hole and set the pole in place to install.
Recommended Nut Torque 30 Nm
80

For M8 screw and nut size

Mounting

L-bracket

1

Hole (9)

3

20

Mounting Surface

For M10 screw and nut size

Mounting

L-bracket

1

Hole (11)

Opposite Side 27

3

35

Mounting Surface
Recommended screw Torque 12.2 Nm

82

Folding Bracket SZQ-001W

Model Number Configuration

Model

Body Color

Circular Bracket SZQ – 001 W

Accessories: Pole Waterproof Ring Binding Head Tapping Screw (2 pcs.)
Outer Dimensions
6OJU: mm
86.1 36.9
79 49
70

W Off-white
Compatible Models
LR4 – PJ QJ , LR5 – PJ KT 1 LR6 – PJ QJ , LR7 – KT 1
(1)3FRVJSFEQPMFJTOPUJODMVEFEXJUIKT

Compatible Pole
POLE22-0100AN,POLE22-0300AN POLE22-0100ANK,POLE22-0300ANK

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZQ-001W Indoor Only IP65 (with product attached
PC
0.09kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

Pole 21.7
70

SZQ-001W
(Unit: mm)

Mounting Dimensional Drawing

90°

Wire Distribution Hole

(15)

Mounting Hole (6×4 places

Mounting Hole (6×4 places

18.5

54~56
73
Screw/Nut M5
Recommended Torque 1.4 N m

83

Pole Installation

1. Install the Pole Waterproof Ring in the Folding Bracket. Check that the 2 ribs are on the outside.

Pole

Pole Waterproof Ring

2. Insert Pole into the Folding Bracket. See the figure on the left for details on the direction of insertion.
3. Tighten the Binding Head Tapping Screws (2 pcs.) from underneath the Folding Bracket.

Folding Bracket

Notice Installation using materials other than the specified accessories is not covered under warranty.

Binding Head Tapping Screw 3×202 pcs.
Recommended Torque 0.8 N m

84

Wallmount Bracket SZK-001U

Model Number Configuration

Model

Body Color

Wallmount Bracket SZK – 001 U

U Silver

Compatible Models

Accessories: Hexagon Socket Set Screw (2 pcs.)
Compatible Pole

LR4 – LJ PJ QJ WC 3, LR5 – LJ PJ KT 1 LR6 – LJ PJ QJ WM 2, LR7 – KT 1
(1)3FRVJSFEQPMFJTOPUJODMVEFEXJUIKT
(2)WM DBOCFVTFEJODPNCJOBJUJPOXJUI4;1BOE10-&” 3FRVJSFEQPMFJTOPUJODMVEFEXJUIWM ()WC DBOCFVTFEJODPNCJOBJUJPOXJUI4;18BOE10-&” 3FRVJSFEQPMFJTOPUJODMVEFEXJUIWC

POLE22-0100AN,POLE22-0300AN,POLE22-0500AN POLE22-0800AN,POLE22-1000AN POLE22-0100ANK,POLE22-0300ANK,POLE22-0800ANK POLE22-0100AT,POLE22-0300AT,POLE22-0500AT POLE22-0800AT,POLE22-1000AT

Outer Dimensions
6OJU: mm

2-M4 90° 62

55 72
9

96.5

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZK-001U Indoor Only IP20 (with product attached)
ADC12
0.19kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Pole 21.7

Mounting Dimensional Drawing

SZK- 001 UMounting Dimensional Drawing

(Unit: mm)

46

Mounting Hole

(63places)

Wire Distribution

80

Hole (15)

25)

(35)
85

Screw/Nut M5

Recommended Torque 1.4 N m

Pole Installation

Pole

1. Insert Pole into the Wallmount Bracket. See the figure on the left for details on the direction of insertion.

2. Secure the Pole with the Hexagon Socket Set Screws (2 pcs.) on the Wallmount Bracket.

Wallmount Bracket

Notice Installation using materials other than the specified accessories is not covered under warranty.

Hexagon Socket Set Screw (2 pcs.)

86

Wallmount Bracket SZK-002 [W/U/K]

Model Number Configuration

Model

Body Color

Wallmount Bracket SZK – 002

Outer Dimensions
6OJU: mm

W Off-white U Silver K Black

Compatible Models
LR4 – WJ , LR5 – WJ WT KT 1
(1)KTDirect Mount

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%)
Remarks

SZK-002 [W/U/K] Indoor Only
IP65 (with product attached)
PC 0.06kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

SZK-002[W/U/K] Mounting Dimensional Drawing

(Unit: mm)

54

45 (2)
70
Product Mounting Hole 3 places
72 8

Mounting Hole (6places)

Wire Distribution Hole (

Screw/Nut M5

Recommended Torque 1.4 N m

70 (54.5)

87

Wallmount Bracket SZK-003 [W/U/K]

Model Number Configuration

Model

Body Color

Wallmount Bracket SZK – 003

Outer Dimensions
6OJU: mm

W Off-white U Silver K Black

Compatible Models
LR6 – WJ WM , LR7 – WJ WT KT 1
(1)KTDirect Mount
Specifications

Model

SZK-003 [W/U/K]

Mounting Location

Indoor Only

Protection Rating

IP65 (with product attached)

Material

PC

Mass (Tolerance ±10%)

0.07kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

SZK-003[W/U/K] Mounting Dimensional Drawing

(Unit: mm)

54

55 90
Product Mounting Hole (3 places)
72 8

Mounting Hole

(2)

(6places)

Wire Distribution Hole (15)

Screw/Nut M5
Recommended Torque 1.4 N m

70 (54.5)

88

Wallmount Bracket SZK-004W

Model Number Configuration

Model

Body Color

Wallmount Bracket SZK – 004 W

Outer Dimensions
6OJU: mm
55 90

W Off-white

Compatible Models
LR6 – WJ , LR7 – WJ WT KT 1
(1)KTDirect Mount
Specifications

Model

SZK-004W

Mounting Location

Indoor Only

Protection Rating

IP65 (with product attached)

Material

PC

Mass (Tolerance ±10%)

0.07kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive. Compatible M16×P1.5 cable gland

Mounting Dimensional Drawing

SZK-004W Mounting Dimensional Drawing

(Unit: mm)

54

Mounting Hole (6places)

Product Mounting Hole (3 places)
72
8

Screw/Nut M5
Recommended Torque 1.4 N m

25

19 70
(54.5)

M16 × P1.5 Cable Gland Mounting

89

Cable gland Installation
Install the cable gland into the Wallmount Bracket from the bottom side. (Required cable gland is not included.) Maximum Torque
10 N m
90

Product Attachment
1. Insert the mounting screws of the product into the Wallmount Bracket. See the figure on the left for details on the direction of insertion.
2. Secure the product with the flanged nuts (3 pcs.) from underneath the Bracket. Recommended Torque
0.6 N m
Notice Installation using materials other than the specified accessories is not covered under warranty.
Flanged nut (3 pcs.)
91

Circular Bracket SZW-001W

Model Number Configuration

Model

Body Color

Circular Bracket SZW – 001 W

Outer Dimensions
6OJU: mm
Product Mounting (LR6) Hole (3 places)

W Off-white

Compatible Models

LR4 – WJ , LR5 – WJ WT KT 1 L R 6 – W J (1)KTDirect Mount

Specifications

Model

SZW-001W

Mounting Location

Indoor Only

Material Mass (Tolerance ±10%)

SPCE 0.06kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing
SZW- 001 W Mounting Dimensional Drawing
(Unit: mm) 90°

Wire Distribution Hole (22)

57

Product Mounting (LR4, LR5) Hole (3 places)

20 90

Mounting Hole (6places)
73
Wire Distribution Hole (12

Screw/Nut M5
Recommended Torque 1.4 N m

92

Product Attachment
1. Insert the mounting screws of the product into the Circular Bracket. See the figure on the left for details on the direction of insertion.
2. Secure the product with the flanged nuts (3 pcs.) from underneath the Bracket. Recommended Torque
0.6 N m
Notice Installation using materials other than the specified accessories is not covered under warranty.
Flanged nut (3 pcs.)
93

Mounting Bracket 4;88

Model Number Configuration

Model

Body Color

4; .PVOUJOH#SBDLFU

8

8 Off-white

“DDFTTPSJFT 3VCCFS’FFUQDT (SPNNFU

Compatible Models
-3 8+ -3 8+ 8+ 85 -3 8+
* Do not use with . .

Specifications

.PEFM

4;88

.PVOUJOH-PDBUJPO

*OEPPST

1SPUFDUJPO3BUJOH

/POF

.PVOUJOH%JSFDUJPO

6QSJHIUPOMZ

.BUFSJBM

41$$

.BTT 5PMFSBODF

LH

3FNBSLT

5IFSFBSFOPDPOUFOUTPGDPOUSPMMFE TVCTUBODFTFYDFFEJOHUIFUISFTIPME GPSUIF3P)4%JSFDUJWF

/PUF5IFSFJTOPQSPUFDUJPOSBUJOHGPSUIJTQSPEVDU 5IFSFJTOPWJCSBUJPOSFTJTUBODFSBUJOHGPSUIJTQSPEVDU

Outer Dimensions
6OJU: mm

.PVOUJOH)PMF

QMBDFT

.PVOUJOH)PMF QMBDFT

-FGUTJEFWJFX

.PVOUJOH)PMF QMBDFT

5PQWJFX

8JSF%JTUSJCVUJPO )PMF

8JSF%JTUSJCVUJPO )PMF

3JHIUTJEFWJFX

‘SPOU7JFX

.PVOUJOH#SBDLFU
3VCCFS’FFU QMBDFT

94

Compatible Direct Mount Bracket SZW-940U
Accessories: Hexagon Nut with Flange (3 pcs.)
Outer Dimensions
6OJU: mm
Product Mounting Hole 3 places
42 20 13.5
M3 Maximum Board Thickness : 10

Model Number Configuration

Model

Body Color

Compatible Direct Mount Bracket SZW – 940 U

U Silver

Compatible Models
-3 WJ
.PVOUJOH)PMF$PNQBUJCMF.PEFM
LCE W LCE AW

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZW-940U Indoor Only IP65 (with product attached
AL
0.04kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

S Z W – 9 4 0 U Mounting Dimensional Drawing

(Unit: mm)

Mounting Hole
(4×3 places) Wire Distribution Hole (12)

5 30

120°
Screw/Nut M3

Recommended Torque 0.6 N m

95

Compatible Direct Mount Bracket SZW-950U
Accessories: Hexagon Nut with Flange (3 pcs.)
Outer Dimensions
6OJU: mm
Product Mounting Hole 3 places
50 20 15
M3 Maximum Board Thickness : 10

Model Number Configuration

Model

Body Color

Compatible Direct Mount Bracket SZW – 950 U

U Silver

Compatible Models
-3 8+ 85
.PVOUJOH)PMF$PNQBUJCMF.PEFM
LE W LES AW LU5

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZW-950U Indoor Only IP65 (with product attached
AL
0.07kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

S Z W – 9 5 0 U Mounting Dimensional Drawing

(Unit: mm)

Mounting Hole A

(4×3 places)

Mounting Hole B (5×2 places)

1012.5

120°

Wire Distribution Hole813

Screw/Nut (Mountiong Hole A)
M3

Screw (Mountiong Hole B)
M4

Recommended Torque 0.6 N m

(1) Refer to “Product Attachment (SZW-950U Mounting Hole A)” for using the Mounting Hole A.
(2) Refer to “Product Attachment (SZW-950U Mounting Hole B)” for using the Mounting Hole B.

96

Compatible Direct Mount Bracket SZW-960U
Accessories: Hexagon Nut with Flange (3 pcs.)
Outer Dimensions
6OJU: mm
Product Mounting Hole 3 places
60 20 8.5
M4 Maximum Board Thickness : 4

Model Number Configuration

Model

Body Color

Compatible Direct Mount Bracket SZW – 960 U

U Silver
Compatible Models
-3 WJ
.PVOUJOH)PMF$PNQBUJCMF.PEFM
LME W

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZW-960U Indoor Only IP65 (with product attached
AL
0.09kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing
S Z W – 9 6 0 U Mounting Dimensional Drawing
(Unit: mm) Mounting Hole (5×3 places) 40

617

120°

Wire Distribution Hole12

Screw/Nut M4

Recommended Torque 0.6 N m

97

Compatible Direct Mount Bracket SZW-970U
Accessories: Hexagon Nut with Flange (3 pcs.)
Outer Dimensions
6OJU: mm
Product Mounting Hole 3 places
70 20 15
M4 Maximum Board Thickness : 10

Model Number Configuration

Model

Body Color

Compatible Direct Mount Bracket SZW – 970 U

U Silver

Compatible Models
-3 8+ 85
.PVOUJOH)PMF$PNQBUJCMF.PEFM
LHE LU7

Specifications

Model Mounting Location Protection Rating
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZW-970U Indoor Only IP65 (with product attached
AL
0.12kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

S Z W – 9 7 0 U Mounting Dimensional Drawing

(Unit: mm)

Mounting Hole

(5×3 places)

1320

120°

Wire Distribution Hole 1418

Screw/Nut M4

Recommended Torque 0.6 N m

98

Product Attachment 4;86
4;86
4;86

Insert the mounting screws of the product into the Compatible Direct Mount Bracket. See the figure on the left for details on the direction of insertion.
If there’s a gap between the Compatible Direct Mount Bracket bottom and the waterproof packing, push until the waterproof packing hits the bottom.
2. Secure the product with the flanged nuts (3 pcs.)
from underneath the Bracket. Recommended Torque
0.6 N m
Installation using materials other than the specified accessories is not covered under warranty. Notice Do not use if twisting, etc., has occurred in the waterproof packing. Failure to comply will result in lower waterproofing performance. Possible cause of failure may occer.
Compatible Direct Mount Bracket Flanged nut (3 pcs.)
99

Product Attachment (SZW-950U Mounting Hole A)
1.Be sure to remove the waterproof packing, from the Compatible Direct Mount Bracket.
2. Insert the mounting screws of the product into the Compatible Direct Mount Bracket. See the figure on the left for details on the direction of insertion.
3. Secure the product with the flanged nuts (3 pcs.)
from underneath the Compatible Direct Mount Bracket. Recommended Torque
0.6 N m
4. Put the waterproof packing on the Compatible Direct Mount Bracketbottom. Push until the waterproof packing hits the Compatible Direct Mount Bracket bottom. Installation using materials other than the specified accessories is not covered under warranty. Notice Do not use if twisting, etc., has occurred in the waterproof packing. Failure to comply will result in lower waterproofing performance. Possible cause of failure may occer.
Compatible Direct Mount Bracket
Flanged nut (3 pcs.)
Compatible Direct Mount Bracket
Waterproof Packing
100

Product Attachment (SZW-950U Mounting Hole B)

1 . Be sure to remove the waterproof packing, hexagon bolts and franged nuts from the Compatible Direct Mount Bracket.
2. Insert the mounting screws of the product into the Compatible Direct Mount Bracket. See the figure on the left for details on the direction of insertion.
3. Secure the product with the flanged nuts (3 pcs.)
from underneath the Compatible Direct Mount Bracket.
Recommended Torque 0.6 N m

Notice Installation using materials other than the specified accessories is not covered under warranty.
4. Place the waterproof packing in line with the mounting hole.

5 . Run the wiring through the distribution hole.
Secure the Compatible Direct Mount Bracket with M4 screw (2 pcs.).
M4 screw is not included. Be sure to prepare mounting screws separately, and consider the
screw threadto be 14 mm or less in order to attach the Compatible
Direct Mount Bracket, and the board thickness of the mounting surface.

Compatible Direct Mount Bracket
Flanged nut (3 pcs.)

Recommended Screw M4×14
Recommended Torque 0.6 N m
Do not use if twisting, etc., has occurred in the waterproof packing. Notice Failure to comply will result in lower waterproofing performance. Possible cause of failure may occer.

Compatible Direct Mount Bracket
8BUFSQSPPG1BDLJOH

.4DSFX QDT
101

Circular Bracket SZ-010
Accessories: Hexagon socket set screw (2 pcs.)
Outer Dimensions
6OJU: mm

Compatible Models
LR4 – LJ PJ QJ WC 3 LR5 – LJ PJ KT 1 LR6 – LJ PJ QJ L4/L5/L6 WM 2 LR7 – KT 1
(1)3FRVJSFEQPMFJTOPUJODMVEFEXJUIKT (2)WM DBOCFVTFEJODPNCJOBJUJPOXJUI4;1BOE10-&” 3FRVJSFEQPMFJTOPUJODMVEFEXJUIWM (3)WC DBOCFVTFEJODPNCJOBJUJPOXJUI4;18BOE10-&” 3FRVJSFEQPMFJTOPUJODMVEFEXJUIWC
Compatible Pole
POLE22-0100AN,POLE22-0300AN POLE22-0500AN,POLE22-0800AN POLE22-1000AN POLE22-0100ANK,POLE22-0300ANK POLE22-0800ANK POLE22-0100AT,POLE22-0300AT POLE22-0500AT,POLE22-0800AT POLE22-1000AT

Pole 21.7
32

100

52.5

Insertion

65

depth of pole

Specifications

Model Mounting Location
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZ-010 Indoor Only
ADC12
0.12kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing

SZ-010
(Unit : mm)

Mounting Dimensional Drawing 90°
Mounting Hole (6×4 places)

102

73
Wire Distribution Hole (12)

Screw/Nut M5

Recommended Torque 1.4 N m

Pole Installation
Pole

1. Insert Pole into the Circular Bracket. See the figure on the left for details on the direction of insertion.
2. Secure the Pole with the Hexagon Socket Set Screws (2 pcs.) on the Wallmount Bracket.
Notice Installation using materials other than the specified accessories is not covered under warranty.

Circular Bracket
Hexagon Socket Set Screw (2 pcs.)

103

Circular Bracket SZ-016A

Accessories: Hexagon Socket Set Screw (2 pcs.) Rubber Bushing Bonded Washer (4 pcs.)
Outer Dimensions
6OJU: mm

Pole 21.7
32

32

Insertion depth of pole

46

68

Compatible Models
LR4 – WC 2 , LR6 – WM 1
(1)WM DBOCFVTFEJODPNCJOBJUJPOXJUI4;1 3FRVJSFEQPMFJTOPUJODMVEFEXJUIWM (2)WC DBOCFVTFEJODPNCJOBJUJPOXJUI4;18 3FRVJSFEQPMFJTOPUJODMVEFEXJUIWC
Compatible Pole
POLE-100A21,POLE-300A21,POLE-800A21

Specifications

Model Mounting Location
Material Mass (Tolerance ±10%) No Accessories
Remarks

SZ-016A Indoor Only
ADC12
0.10kg
There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Mounting Dimensional Drawing
S Z – 0 1 6 A Mounting Dimensional Drawing
(Unit : mm) 90°

Mounting Hole (5×4 places)

54

Wire Distribution Hole (12)

Screw/Nut M4

Recommended Torque 1.1 N m

104

Pole Installation

Pole

1.Insert the Rubber Bushing into the pole.
2. Insert Pole into the Circular Bracket. See the figure on the left for details on the direction of insertion.
3. Secure the Pole with the Hexagon Socket Set Screws (2 pcs.) on the Wallmount Bracket.

Rubber Bushing

Notice Installation using materials other than the specified accessories is not covered under warranty.

Circular Bracket
Hexagon Socket Set Screw (2 pcs.)

105

Pole N
POLE22- [0100/0300/0500/0800/1000] AN POLE22- [0100/0300/0800] ANK

Model Number Configuration

Model

Pole length

Color

Pole POLE22 – AN

0100 100mm 0800 800mm 0300 300mm 1000 1000mm 0500 500mm

(None) Silver K Black

(1)Pole length 0100 , 0300 , 0800 only

CAopmppliactaible Models
Accessory :Binding Head Tapping Screw (2pcs.)
LR4 – PJ LJ QJ , LR5- PJ LJ KT
LR6- PJ LJ QJ LR7- KT

Outer Dimensions
6OJU: mm

15.5

21.7

Compatible Optional Parts

SZP-001W SZP-002U SZP-003 SZQ-001W SZK-001U

POLE22-0100AN POLE22-0100ANK

POLE22-0300AN POLE22-0300ANK

POLE22-0500AN ×

×

×

POLE22-0800AN POLE22-0800ANK

×

×

×

POLE22-1000AN ×

×

×

SZ-010

Specifications

Pole Length L

Model

POLE22-0100AN POLE22-0300AN POLE22-0500AN POLE22-0800AN POLE22-1000AN

POLE22-0100ANK POLE22-0300ANK

POLE22-0800ANK

Mounting Location

Indoor Only

Pole length L (mm)

100

300

500

800

1000

Material

AL

Mass (Tolerance ±10%) /PAccessories

0.05kg

0.16kg

0.26kg

0.42kg

0.52kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Notice

Use a pole which is 300mm or less in length when using a resin bracket. Use an AL Bracket when using a pole which is 500mm or more in length.

106

Pole T POLE22- [0100/0300/0500/0800/1000] AT

Model Number Configuration

Model

Pole length

Pole POLE22 – AT

0100 100mm 0800 800mm 0300 300mm 1000 1000mm 0500 500mm

Accessory :Hexagon Nut (2pcs.) Plain Washer (2pcs.) Binding Head Tapping Screw (2pcs.)

CAopmppliactaible Models
LR4 – PJ LJ QJ , LR5- PJ LJ KT LR6- PJ LJ QJ LR7- KT

Specifications

Compatible Optional Parts SZP-917U,SZL-001,SZK-001U,SZ-010

Model Mounting Location Pole Length L (mm)
Material
Mass (Tolerance ±10%) /PAccessories
Remarks

POLE22-0100AT 100

POLE22-0300AT 300

POLE22-0500AT Indoor Only 500 AL

POLE22-0800AT 800

POLE22-1000AT 1000

0.05kg

0.15kg

0.26kg

0.42kg

0.52kg

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

Outer Dimensions
6OJU: mm

15.5

21.7

Pole Length L

10

32

M22P=1.5 2.5
Maximum Board Thickness Effective threaded screw length

107

Pole Bracket Installation

Binding Head Tapping Screw 3×122pcs.
Recommended Torque
0.8 N m

Refer to ” 8 Unit Detachment Method” under < Body Unit > removal on pg 53 for details.
1. Install the Pole Waterproof Ring in the Pole Bracket. Check that the 2 ribs are on the outside.

Pole Bracket
Pole Waterproof Ring

2. Insert Pole into the Pole Bracket. See the figure on the left for details on the direction of insertion.

3. Tighten the Binding Head Tapping Screws (2 pcs.) from the topside of the Pole Bracket.

Pole

Notice Installation using materials other than the specified accessories is not covered under warranty.

108

Pole POLE- [100/300/800] A21

Model Number Configuration

Model

Pole length

Pole POLE – A21

100 100mm 800 800mm 300 300mm

Outer Dimensions
6OJU: mm 2

18.1

8 21.7

Pole Length L

CAopmppliactaible Models
LR4 – WPJC , LR6 – WPJM

Compatible Optional Parts SZP-004,SZP-005W,SZK-001U,SZ-010,SZ-016A

Specifications

Model

POLE-100A21 POLE-300A21 POLE-800A21

Mounting Location

Indoor Only

Pole length L (mm)

100

300

800

Material

AL

Mass (Tolerance ±10%) /PAccessories

0.03kg

0.09kg

0.23kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

2 20.5

109

Pole 22POLE-300SAT

Outer Dimensions

6OJU: mm

21.7

17.7

Model Number Configuration

Model

Pole length

Pole 22POLE – 300 SAT

300 300mm

CAopmppliactaible Models
LR4 – WPJC

Compatible Optional Parts SZP-005W,SZP-006

Specifications

Model

22POLE-300SAT

Mounting Location

Indoor Only

Pole length L (mm)

300

Material

SUS

Mass (Tolerance ±10%) /PAccessories

0.43kg

Remarks

There are no contents of controlled substances exceeding the threshold for the RoHS Directive.

300
10 (33)

Mounting Angle is assembled in the oppsite direction at shipping.
42

Installation Figure

1 Make holes for the mounting for the product. 2 Run the wiring through the distribution hole. 3 Secure the product with the bolts, nuts and screws.

22POLE-300SAT Installation Figure
Unit: mm
23
Feed the wiring through the hole and set the pole in place to install.
Recommended Nut Torque 30 Nm

For M8 screw and nut size

Mounting

Mounting Angle

1

Hole (9)

3

20

Mounting Surface

For M10 screw and nut size

Mounting

Mounting Angle

1

Hole (11)

55 75

3

2-11

9

30 20 80
35

Opposite Side 27

3

35

Mounting Surface
Recommended screw Torque 12.2 Nm

Mounting Angle Dimention

110

M12 Connector with Cable SZ-120-02 / -05 / -10

Compatible Models
LR4 – WC , LR6 – W8 L8 WC WM

Outer Dimensions
6OJU: mm

Specifications

Model Mounting Location Cable length L (m) Jacket Diameter / Color Number of core wires Cross section Area
Connector Remarks

SZ-120-02

SZ-120-05

Indoor Only

2

5

6.3 / Light gray

8

AWG23

Female Straight

Manufactured by the OMRON Corp.

SZ-120-10 10

(15) 40.7

M12 Connector Pin Layout

Pin No.

Wire Color White Brown Green Yellow Gray Pink Blue Red

Cable Length L

30 50
5

111

Documents / Resources

PATLITE LR4-WC LED Signal Tower [pdf] Instruction Manual
LR4-WC, LR5, LR6, LR7, LR4-WC LED Signal Tower, LED Signal Tower, Signal Tower, Tower

References

Leave a comment

Your email address will not be published. Required fields are marked *