MEAN WELL RSP-100-3.3 100W Single Output with PFC Function
Features
- Universal AC input/ Full range
- Built-in active PFC function
- High efficiency up to 88%
- Cooling by free air convection
- Built-in remote ON-OFF control
- Protections: Short circuit/ Overload/ Over voltage / Over temperature
- LED indicator for power on
- 3 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
RSP-100 is a 1 OOW single output enclosed type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection , working for the temperature up to 70°C.
Model Encoding/ Order Information
SPECIFICATION
MODEL | RSP-100-3.3 | RSP-100-5 | RSP-100-7.5 | RSP-100-12 | RSP-100-13.5 | RSP-100-15 | RSP-100-24 | RSP-100-27 | RSP-100-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
RATED CURRENT | 20A | 20A | 13.5A | 8.5A | 7.5A | 6.7A | 4.2A | 3.8A | 2.1A | |
CURRENT RANGE | 0-20A | 0-20A | 0-13.5A | 0 – 8.5A | 0- 7.5A | 0- 6.7A | 0-4.2A | 0- 3.8A | 0-2.1A | |
RATED POWER | 66W | 100W | 101.25W | 102W | 101.25W | 100.5W | 100.8W | 102.6W | 100.8W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE | 3.14-3.63V | 4.75 – 5.5V | 7.13-8.25V | 11.4-13.2V | 12.8 -14.9V | 14.3-16.5V | 22.8 – 26.4V | 25.7- 29.7V | 45.6 – 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 600ms, 30ms at full load | |||||||||
HOLD UP TIME (Typ.) | 16ms at full load | |||||||||
INPUT | VOLTAGE RANGE | 85- 264VAC 120- 370VDC | ||||||||
FREQUENCY RANGE | 47- 63Hz | |||||||||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.98/115VAC at full load | |||||||||
EFFICIENCY (Typ.) | 83% | 86% | 87% | 86% | 86.5% | 87% | 87% | 87% | 88% | |
AC CURRENT (Typ.) | 1.1A/115VAC 0.55A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | COLD START 30A/230VAC | |||||||||
LEAKAGE CURRENT | <2mA / 240VAC | |||||||||
PROTECTION | OVERLOAD | 105 – 135% rated output power | ||||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 3.63 – 4.46V | 5.5- 6.75V | 8.25 – 10.13V | 13.2-16.2V | 14.85 -18.23V | 16.5- 20.25V | 26.4 – 32.4V | 29.7 – 36.45V | 52.8 – 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|||||||||
FUNCTION | REMOTE CONTROL | CN1: < 0-0.8VDC POWER ON, 4-1OVDC POWER OFF | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 – +70’C (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 – 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 – +85’C, 10 – 95% RH non-condensing | |||||||||
TEMP. COEFFICIENT | ±0 05%/’C (0 – 50’C) | |||||||||
VIBRATION | 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
OVER VOLTAGE CATEGORY | III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude upto2000 meters | |||||||||
SAFETY & EMC (Note4) |
SAFETY STANDARDS |
UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1,
BSMI CNS14336-1 approved, Design refertoAS/NZS 62368.1 |
||||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-0/P, 1/P-FG, O/P-FG:100M Ohms/ 500VDC I 25°C/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | |||||||||
OTHERS | MTBF | 2325.2K hrs min. Telcordia SR-332 (Bellcore); 288.5K hrs min. MIL-HDBK-217F (25°C) | ||||||||
DIMENSION | 179’99’30mm (L’W’H) | |||||||||
PACKING | 0.52Kg; 24pcs/14.5Kg/0.81CUFT | |||||||||
NOTE |
|
Mechanical Specification
Termina l Pin No. Assignment
Pin No. |
Assignment |
Pin No. |
Assignment |
1 |
AC/L | 4,5 | DC OUTPUT-V |
2 |
AC/N | 6,7 | DC OUTPUT+V |
3 |
FG-½ |
Remote ON/OFF(CN 1 ): JST S2B-XH or equivalent(optional)
Pin No. |
Assignment |
Mating Housing |
Terminal |
1 |
RC+ | JSTXHP or equivalent | JST SXH-00 1T-P0.6 or equivalent |
2 |
RC- |
Derating Curve
Output Derating VS Input Voltage
Downloaded from Arrow.com.
Documents / Resources
![]() |