MEAN WELL RSP-100-3.3 100W Single Output with PFC Function

MEAN WELL RSP-100-3.3 100W Single Output with PFC Function

Features

Features

  • Universal AC input/ Full range
  • Built-in active PFC function
  • High efficiency up to 88%
  • Cooling by free air convection
  • Built-in remote ON-OFF control
  • Protections: Short circuit/ Overload/ Over voltage / Over temperature
  • LED indicator for power on
  • 3 years warranty

Applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • RF application

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

RSP-100 is a 1 OOW single output enclosed type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection , working for the temperature up to 70°C.

Model Encoding/ Order Information

Model Encoding/ Order Information

SPECIFICATION

MODEL RSP-100-3.3 RSP-100-5 RSP-100-7.5 RSP-100-12 RSP-100-13.5 RSP-100-15 RSP-100-24 RSP-100-27 RSP-100-48
OUTPUT DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
RATED CURRENT 20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A
CURRENT RANGE 0-20A 0-20A 0-13.5A 0 – 8.5A 0- 7.5A 0- 6.7A 0-4.2A 0- 3.8A 0-2.1A
RATED POWER 66W 100W 101.25W 102W 101.25W 100.5W 100.8W 102.6W 100.8W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 3.14-3.63V 4.75 – 5.5V 7.13-8.25V 11.4-13.2V 12.8 -14.9V 14.3-16.5V 22.8 – 26.4V 25.7- 29.7V 45.6 – 52.8V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 16ms at full load
INPUT VOLTAGE RANGE 85- 264VAC        120- 370VDC
FREQUENCY RANGE 47- 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC           PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 83% 86% 87% 86% 86.5% 87% 87% 87% 88%
AC CURRENT (Typ.) 1.1A/115VAC         0.55A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 105 – 135% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 3.63 – 4.46V 5.5- 6.75V 8.25 – 10.13V 13.2-16.2V 14.85 -18.23V 16.5- 20.25V 26.4 – 32.4V 29.7 – 36.45V 52.8 – 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE  

Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION REMOTE CONTROL CN1: < 0-0.8VDC POWER ON, 4-1OVDC POWER OFF
ENVIRONMENT WORKING TEMP. -30 – +70’C (Refer to “Derating Curve”)
WORKING HUMIDITY 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 – +85’C, 10 – 95% RH non-condensing
TEMP. COEFFICIENT ±0 05%/’C (0 – 50’C)
VIBRATION 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude upto2000 meters
SAFETY &
EMC
(Note4)
 

SAFETY STANDARDS

UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1,

BSMI CNS14336-1 approved, Design refertoAS/NZS 62368.1

WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-0/P, 1/P-FG, O/P-FG:100M Ohms/ 500VDC I 25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 2325.2K hrs min.   Telcordia SR-332 (Bellcore); 288.5K hrs min.       MIL-HDBK-217F (25°C)
DIMENSION 179’99’30mm (L’W’H)
PACKING 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25’C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component  which will be installed into a final equipment.  The final equipment must be re-confirmed  that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.’ (as available on http://www.meanwell.com)
  5. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1OOOm with fanless models and of 5°C/1OOOm with fan models for operating altitude higher * than 2000m(6500ft).
    Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification Mechanical Specification

Termina l Pin No. Assignment

Pin No.

Assignment

Pin No.

Assignment

1

AC/L 4,5 DC OUTPUT-V

2

AC/N 6,7 DC OUTPUT+V

3

FG-½

Remote ON/OFF(CN 1 ): JST S2B-XH or equivalent(optional)

Pin No.

Assignment

Mating Housing

Terminal

1

RC+ JSTXHP or equivalent JST SXH-00 1T-P0.6 or equivalent

2

RC-

Block Diagram

Derating Curve

Derating Curve

Output Derating VS Input Voltage

Output Derating VS Input Voltage

Downloaded from Arrow.com.

MEAN WELL-Logo

Documents / Resources

MEAN WELL RSP-100-3.3 100W Single Output with PFC Function [pdf] Owner's Manual
RSP-100-3.3 100W Single Output with PFC Function, RSP-100-3.3, 100W Single Output with PFC Function, Single Output with PFC Function, Output with PFC Function, PFC Function, Function

References

Leave a comment

Your email address will not be published. Required fields are marked *