150W Single Output with PFC Function
Instruction Manual
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- 250% peak power capability
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- 1U low profile 38mm
- Built-in remote sense function
- 5 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Diagnostic or biological facilities
- Test or measurement systems
- Telecommunication equipment
■ GTIN CODE
MW Search:https://www.meanwell.com/serviceGTIN.aspx
■ Description
HRP-150N is a 150W single output type AC/DC power supply. This series operates for 85-264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C without cover. Moreover, HRP-150N provides 250% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
■ Model Encoding
HRP | Output voltage(12/24/36/48V) |
150N | Rated wattage |
24 | Series name |
SPECIFICATION
MODEL | HRP-150N- 2 | HRP-150N-24 | HRP-150N-36 | HRP-150N-48 | |||
OUTPUT | DC VOLTAGE | 12V | 24V | 36V | 48V | ||
RATED CURRENT | 13A | 6.5A | 4.3A | 3.3A | |||
CURRENT RANGE | 0 ~ 13A | 0 ~ 6.5A | 0 ~ 4.3A | 0 ~ 3.3A | |||
RATED POWER | 156W | 156W | 154.8W | 158.4W | |||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |||
VOLTAGE ADJ. RANGE | 10.2 ~ 13.8V | 21.6 ~ 28.8V | 28.8 ~ 39.6V | 40.8 ~ 55.2V | |||
VOLTAGE TOLERANCE Note.3 | ±1.5% | ±1.5% | ±1.5% | ±1.5% | |||
LINE REGULATION | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE TIME | 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load | ||||||
INPUT |
VOLTAGE RANGE ote.4 | 85 ~ 264VAC 120 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||
EFFICIENCY (Typ.) | 88% | 88% | 89% | 89% | |||
AC CURRENT (Typ.) | 1.7A/115VAC 0.9A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 35A/115VAC 70A/230VAC | ||||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||||
PROTECTION |
OVERLOAD |
Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power on to recover | |||||
Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover | |||||||
OVERVOLTAGE | 14.4 ~ 16.8V | 30 ~ 34.8V | 41.4 ~ 48.6V | 57.6 ~ 67.2V | |||
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
ENVIRONMENT | WORKING TEMP. | -40 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -50 ~ +85℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.04%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
OPERATING ALTITUDE Note.6 | 5000 meters | ||||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032 | Class B | |||||
Radiated | BS EN/EN55032 | Class B | |||||
Harmonic current | BS EN/EN61000-3-2 | Class A | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2) | ||||||
Parameter | Standard | Test Level / Note | |||||
ED | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact | |||||
RF field | BS EN/EN61000-4-3 | Level 3, 10V/m | |||||
EFT/ Burst | BS EN/EN61000-4-4 | Level 3, 2KV | |||||
Surge | BS EN/EN61000-4-5 | Level 4, 4KV/Line-FG; 2KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 3, 10V | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods | |||||
OTHERS | MTBF | 1740.3K hrs min. Telcordia SR-332 (Bellcore) ; 221.7K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 159*97*38mm (L*W*H) | ||||||
PACKING | 0.54Kg; 24pcs/12.96Kg/0.9CUFT |
NOTE
- All parameters NOT specially mentioned are measured at 230VAC input rated load, and 25℃ of ambient
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation, and load
- Derating may be needed under low input Please check the derating curve for more details.
- The power supply is considered a component that will be installed into a final All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
- The ambient temperature derating of 5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
※ Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
PWM fosc: 90KHz
Derating Curve
Output Derating VS Input Voltage
Function Manual
- Remote Sense
The remote sensing compensates for voltage drop on the load wiring up to 0.5V.
- Peak Power
P av: Average output power (W)
P pk: Peak output power (W)
P npk: Non-peak output power(W)
P rated: Rated output power(W)
t : Peak power width(sec)
T : Period(sec)
For example (12V model) :
Vin = 100V Duty_max = 25%
Pav = Prated = 156W
Ppk = 300W
t ≤ 5 sec
T≧ 20 sec
P npk≤ 108W
Mechanical Specification
Terminal Pin No. Assignment :
Pin No. | Assignment | Pin No. | Assignment |
1 | AC/L | 4,5 | DC OUTPUT -V |
2 | AC/N | 6,7 | DC OUTPUT +V |
3 | FG |
Connector Pin No. Assignment (CN100) :
HRS DF11-6DP-2DSA or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1 | -S | HRS DF11-6DSor equivalent | HRS DF11-**SC or equivalent |
2 | +S | ||
3-6 | NC |
Installation Manual
Please refer to : http://www.meanwell.com/manual.html