MEAN WELL Logo150W Single Output with PFC Function
LPP-150 series
MEAN WELL LPP-150 series Single Output with PFC Function

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTlN.aspx

Features:

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.96
  • Protections: Short circuit / Overload / Over voltage
  • Protections:Over temperature(option)
  • Cooling by free air convection
  • 100% full load burn-in test
  • Fixed switching frequency at PFC:67KHz  PWM:134KHz
  • 3 years warranty

MEAN WELL LPP-150 series Single Output with PFC Function - QR CODEhttps://www.meanwell.com/Upload/PDF/PCB_EN.pdf

SPECIFICATION

MODEL LPP-150-3.3 LPP-150-5 LPP-150-7.5 LPP-150-12 LPP-150-13.5 LPP-150-15 LPP-150-24 LPP-150-27 LPP-150-48
OUTPUT DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
RATED CURRENT 30A 30A 20A 12.5A 11.2A 10A 6.3A 5.6A 3.2A
CURRENT RANGE 0 ~ 30A 0 ~ 30A 0 ~ 20A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 10A 0 ~ 6.3A 0 ~ 5.6A 0 ~ 3.2A
RATED POWER 99W 150W 150W 150W 151.2W 150W 151.2W 151.2W 153.6W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 600ms, 30ms at full load
HOLD UP TIME (Typ.) 30ms at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC        120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF≧0.96/230VAC         PF≧0.97/115VAC at full load
EFFICIENCY(Typ.) 70% 76% 80% 82% 83% 83% 85% 85% 85%
AC CURRENT (Typ.) 2.5A/115VAC       1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 55A/230VAC
LEAKAGE CURRENT <3.5mA / 240VAC
PROTECTION OVERLOAD 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 3.63 ~ 4.45V 5.5 ~ 6.75V 8.25 ~ 10.1V 13.2 ~ 16.2V 14.85 ~ 18.2V 16.5~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.5V 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -10 ~ +60℃ with cooling FAN (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.05%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 4)
SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 2635.3K hrs min.     Telcordia SR-332 (Bellcore) ; 292.7K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 222*75*41mm (L*W*H)
PACKING 0.62Kg; 24pcs/16.6Kg/1.63CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.  Tolerance : includes set up tolerance, line regulation and load regulation.
4.  The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com)
5.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL LPP-150 series Single Output with PFC Function - Mechanical SpecificationAC Input Connector (CN1) : JST B5P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2,4 No Pin
3 AC/N
5 FG Earth

DC Output Connector (CN2) : JST B6P-VH*2 or equivalent

Pin No. Assignment Mating Housing Terminal
1~6 -V JST VHR  or equivalent JST SVH-21T-P1.1 or equivalent
7~12 +V

Earth: Grounding Required
CN1: Pin 5 is safety ground

Block Diagram

MEAN WELL LPP-150 series Single Output with PFC Function - Block Diagram

Derating Curve

MEAN WELL LPP-150 series Single Output with PFC Function - Derating Curve

Output Derating VS Input Voltage

MEAN WELL LPP-150 series Single Output with PFC Function - Output Derating VS Input Voltage

MEAN WELL LogoFile Name: LPP-150-SPEC 2022-09-20MEAN WELL LPP-150 series Single Output with PFC Function - Icon 1

Documents / Resources

MEAN WELL LPP-150 series Single Output with PFC Function [pdf] User Guide
LPP-150-3.3, LPP-150-5, LPP-150-7.5, LPP-150-12, LPP-150-13.5, LPP-150-15, LPP-150-24, LPP-150-27, LPP-150-48, LPP-150 series Single Output with PFC Function, LPP-150, series Single Output with PFC Function, Output with PFC Function, PFC Function, Function

References

Leave a comment